Deye inverter: Smart Load settings powering 2 geysers

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ต.ค. 2024
  • A short practical video showing conditions and settings for using your Smart Load output to power geysers.

ความคิดเห็น • 7

  • @ThePonderi
    @ThePonderi 9 หลายเดือนก่อน

    Excellent setup on your geysers...

  • @mohamadrashid5854
    @mohamadrashid5854 8 หลายเดือนก่อน +1

    Hello i have a question
    I also use smart load on my deye 6kw inverter
    I put my conditions for 50% 55% for the battery and the 1000w for PV
    For the on condition it is doing alright (when pv is higher than 1000w and lithium battery it kicks on) but for the off condition it only kicks on when the battery is below 50% and ignores the PV condition
    Can you explain that to me please

    • @bolandsystems2024
      @bolandsystems2024  2 หลายเดือนก่อน

      It swithes On when both parameters are met.
      It switches off when 1 parameter is not met >1min.
      It swithes back on after the battery has charged & both are met again.
      Your geyser's kW should preferably be lower than the PV setting, or you will cycle your battery a lot!

  • @KamenKr
    @KamenKr 5 หลายเดือนก่อน

    What does this Smart text mean?

  • @ameercader
    @ameercader 22 วันที่ผ่านมา

    How do I get smart load to work please 😊

    • @bolandsystems2024
      @bolandsystems2024  22 วันที่ผ่านมา +1

      See manual:
      1. Wire as an OUTPUT onto GEN input
      2. Set SMART LOAD settings in GEN setup
      3. Parameters set to switch output ON:
      a. Solar Watts must be reached
      b. Battery SOC% must be reached
      BOTH MUST BE REACHED TO SWITCH ON.
      To be done by an electrician!!!

    • @appalachianmoonshiner7084
      @appalachianmoonshiner7084 19 วันที่ผ่านมา

      @@bolandsystems2024 what about setup when there is no option in menu solar watt. There is only bat On and Off?