Detailed Solar Inverter Installation: A Step-by-Step Guide
ฝัง
- เผยแพร่เมื่อ 15 ต.ค. 2024
- In this video, we will walk you through the process of quickly and effectively installing a solar inverter, a crucial component of any solar power system. Installing a solar inverter correctly is essential for harnessing and converting the solar energy into usable electricity. By following our step-by-step guide, you'll gain the knowledge and confidence to complete the installation smoothly.
______________________________________________________________
Website
powmr.com/
Facebook
/ powmrsolar
Email:
support@powmr.com
See you in my next video! :)
______________________________________________________________
1: PowMr 10KW Solar Inverter Unboxing
• PowMr 10KW Solar Inver...
2: How to choose the right solar inverter- PowMr
• How to choose the righ...
LOVE THE WAY YOU TALK NICE EXPLANATION
i am in love with this girl. 😍
That's a nice explanation.
Your explanations and demonstrations are perfect. Only slight thing you could have explained is how you sized those AGW wires and circuit breakers since those inverters are not the same. And their cables will differ. Other than that Great job.
Hi, thanks for your advice.
Is the output N floated or connected to the input ground? In your example is the RCD not necessary for you?
Great explanation. Thank you!
Verry Helpfull Thanks Powmr ❤
Thanks for your support.
That's a nice explanation. I have a question. What's the difference between "Hybrid Inverters" and "All In One Inverters"? For example, "POW-HVM5.5M" vs "POW-HPM5.6KW".
Hi, the hybrid inverter has the function with Grid-off and Grid-on, while the all in one inverter indicates the off grid inverter with its own built-in mppt.
@@PowmrSolar So, the All-in-One is only for off-grid? I'm confused.
Or just get the Hybrid?
@@807800Yes, the all in one is for off-grid. Do you need to transfer power to the mains? If you don't need it, you can choose any one.
@@PowmrSolar I see. The differene is only about transferring power to the main, but both can still be used for on-grid with main connected.
Thank you.
@@807800 Yes.
I have the US-POW-SunSmart 10KP-NYF. Batteries show 54v but the inverter with not turn on, on battery alone. It will in PV alone but only shows 10v on batteries.
Hi, please send your problem to this email: support@powmr.com.
can you power on the inverter using the AC in first if the battery is low charge? so it can charge the battery.
which model?
Good explanaitions and well spoken English language, Congratulation to you....
Thanks.
You did not show all the wiring. Where do the wires go after they come out of the breakers? What are the wires going from the black and red bus bars connected to(that rectangular white box below). Where do I plug in my loads? I need to know this information! Thanks...
Please send your problem to this email: support@powmr.com
Hello did you find the solution for our colleage who gets 150watts of Idle consumption (empty consumptio) on your 5500 watt model ?
Hi, kindly send us the model number.
What is the rs232 port on the left hand side used for
I bought one power solar hybrid inverter 3000w 24 v dc . I’m conest everything finished . And I don’t see solar panels conest. Can you help me one video about that please ❤
I don’t see solar panels conest? Are you referring to how to connect the solar panels?
I ordered your 6.2kw Hybrid inverter, it keeps on giving me Error 51 which according to your manual it needs to be brought to service center, I chatted with your Customer Service in your online store and only instructed me to check the item by disassembling it and testing it. Can I just have a replacement of the item? Checking and disassembling the inverter just makes me more frustrated that I bought and paid in full yet I feel I'm the one who is doing the job fixing it...😢
Kindly send us your order number.
Thanks u are a brilliant
Can I use common grounding for Solar panel grid and Inverter and SPD. Thanks
Just ground the inverter. Because the solar panels are connected to the inverter. Grounding the inverter is equivalent to grounding the solar panel.
The SPD is also connected to the solar panel. Just take them as a whole and ground them on the inverter shell.
Thanks. One more thing can I ground with the grounding rod from grid.
@@YakubHasan If you are grounded from the grid, then the input end of the inverter does not need to be grounded. If your output needs to be grounded, you can connect the ground wire to the inverter's housing screws, and then ground the inverter's housing screws.
Can I bond the neutral to the earth bar?
May I know which model?
@@PowmrSolar POW-HVM6.2M-48V-N is the model. I want to earth bond the neutral of the AC output of the inverter.
@@postiemania This model does not have its own neutral point grounding. But yes, you can do the neutral point grounding yourself.
@@PowmrSolar thank you. In Australia this is called the M.E.N. system (multiple earthed neutral) and this keeps the neutral wire at earth potential.
@@postiemania Okay, get it. Thanks for letting me know.
Does the PowMr have an internally bonded neutral?
may I know which model you are asking about?
@PowmrSolar POW-LVM5K-48V-N. This is to be installed in an off-grid camp where power will be provided by a PV array and battery. Occasionally a gasoline powered generator may be used to provide power on demand , but no electrical utility is present. The POW-LVM5K-48V-N will power a typical residential electrical panel. I would like to know if the neutral bus should be bonded within the panel or if they should be kept separate as in a residential subpanel.
@@PowmrSolar POW-LVM5K-48V-N
@@PowmrSolar POW-LVM5K-48V-N
@@PowmrSolar POW-LVM5K-48V-N
How can I connect the output to RCD for the 10.2kw model? It has only two output pins. Is the earth ground connected to the output N pin internally?
The ground cannot be connected to the internal N port of the leakage protection switch. The output terminal can be directly connected to the ground screw of the fuselage shell.
It is recommended to connect to a standard AC circuit breaker rather than a leakage protection switch
@PowmrSolar We need a diagram instead of this movie. This is not a simple plug and play consumer product.
@@dskim9242 Please send your problem to this email: support@powmr.com.
@PowmrSolar I sent you two emails but no reply
@@dskim9242 Please send us your email.
I just got a 10.2 invertor. My question was do it start up and work with no batterie conect on the invertor..
Hi, yes, but we do not recommend working without batteries, as PV generating electricity during the day without batteries is not a constant process itself.
The PV may be high or low, and it does not completely match the customer's load usage habits, which will lead to the fact that when the PV power generation is good, the load may not be used so much, resulting in waste; or when the PV power generation is not good, the load needs a lot Electricity, if PV cannot be brought up, it may be completely replaced by mains electricity.
If there is a battery, it is different. If there is more PV, it will be stored in the battery. If the PV is not enough, the power in the battery will be used. Except for special circumstances, the mains power will be used.
I install 6.5kw powmr inverter. 8 solar panels jinko n type 580 watt install in series. When I consumed 2000 watt above. Inverter showed error no 8 bus voltage is to high. How can I solve
Hi, kindly send your problems to this email: support@powmr.com.
can i use only off grid this inverter
Yep.
My inverter has 3 ac input and 3 ac output so should i just install 2 input and 2 output?
Hi, kindly send us the model number?
Olá! No tampa do inversor 6,2kw esta escrito: "não conecte a bateria depois que o utilitário estiver ligado". O que quer fizer isto, e o que acontece se ligar a bateria?
It should be a reminder to connect the battery before connecting to mains power.
I have 150watt idle consumption for the 5K inverter, is that typical?
Hi, which model? Please send us the product label?
My 24v 3000 PowMr does not charge ith my 400W solar panel. Panel is giving 36 volts but no sol;ar display in LCD of inverter. I have one 24v 200ah Lifep04 battery from Chins
please send your problem to this email: support@powmr.com.
@@PowmrSolar I think I found the issue. The unit needs 120v input on PV and my panel only brings 36v
It inverter works off grid?? Only with batery (no ac input).
which model?
@@PowmrSolar POW-HVM4.2M-24V-N
@@hanus1987 It is a hybrid inverter.
@@PowmrSolar IT MEAN yes or no???
@@hanus1987 Yes, this model can work off grid.
How many 48v 200amp battery can PowMr 5,500 watts hybrid inverter can?
Hi, 6 units can be paralleled.
How connect this inverter to Home Assistant?
Can i use only solar, without battery?
Which model?
how to buy the PowMR invertor in pakistan can you guide me
Hi, may I know which model?
Im using powmr inverter 5.5 kw its very nice
Thanks for your support.
What a jewel
what is the idle consumption?
Less than 150W.
Nice review
Thanks
How can I get rid of the beep sound when I switch it off and on please help
which model?
Yum yum what a queen
Buenas días desde México tengo un controlador y marca E_11 herror que puede ser
Kindly send us the model number.
Merinsak nak rupo hau klaka omputeh,, bgus xboh klaka
Its better your explanation showing schematic of your wireing installation.
Thanks for your advice.
Why is there no ground cable for the AC output?
The machine usually has a grounding screw. You can connect the ground cable to the grounding screw.
@@PowmrSolar How is the ground screw getting its ground if the AC INPUT has no ground? Shouldn't the AC INPUT get its ground from grid power? Thank you for replying.
@@JR88888 Connect the ground cable of the AC input to the ground screw, and then directly ground the ground screw.
@@PowmrSolar , I want to confirm that the 3 wires for AC go directly to the 3 slots for AC INPUT and not the ground screw on the chassis. The AC OUT wires L and N go to the AC OUT slots (L and N). The ground from the AC OUT wire connects to the ground screw on the chassis.
@@JR88888 for 110V or 220V? We also have inverters designed with ground wire ports.
With out battery working
I Need 6.5kw without battery working
I need in pakistan
So sand me
Working with battery.
22AWG wire for connecting a battery? Most inverters come with thick 2 AWG wire for hooking up the battery.
Hi, may I know which model?
@@PowmrSolar in your video at 4:15 she shows the battery cable. She must be hooking it up to a tiny battery. 22AWG wire is what you might use for LED lights that pull 4 watts.
@@robertwan8561 Hi, two 2AWG wires.
She sounds so sweet
Pav Mr 6.2kw invater open circuit
500V.
Bukan terminos,, tapi terminal
Pan lo mr