How to Predict Scaling or Fouling in RO membrane | RO plant | Fouling and Scaling in RO membrane |
ฝัง
- เผยแพร่เมื่อ 31 พ.ค. 2021
- Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
CIP procedure of RO membrane :- • CIP procedure for RO m...
What is Fouling and Scaling in RO membrane :- • Fouling and Scaling in...
Function of RO membrane :- • RO Membrane in hindi |...
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#PowerPlantDiscussion
#FoulingScaling
Thanks to all of you for connecting me.
धन्यवाद सर आपके गाईडनेशन से हमारी जाणकारि बेहत्तर बनाती है जीससे आत्मविश्वास बडता है और हम बेटर परफॉर्मन्स कर सकते है
Explain out standing
Thanks
Thank you universe
very helpful videos
Thanks friend
Good information for water treatment related
Thanks for sharing
Bahut acha sir I'm interested good job
Very useful information
Thank you for video
Great video
Thank you so much
Sir. Mene apke sare video download karke apni book me likha hai. Ab tak 5 book complete huvi
Kaun sa book
@@PowerPlantDiscussion sir note book me jab interview ho tab nazar fer leta hu.
Very nice dear
Pl.send your mobile number.
Please send your mail id I'll send my contact no.
Good job
Excellent awesome explanation Brother ..carry on 🎉 your each and every single content so helpful for us ....
bahut dhyan deke samjha rahe hai very nice information
Thanks
Thanks
Nice video
Nice sir
Well Explaine thank you so much
Most welcome
Good
Jabarjast
Thanks
Kept it up
Amazing sir.
Thanks dear
Super explain sir.....
Thanks dear
Thanks for the these informative session as per our demand. Wish you to make such type of vedio which will be very helpful to us for enhancing our knowledge. Thanks once again. Again request to plz build vedio on jar test, cpu unit, and dosing system in boiler(O2 dosing, ammonia dosing and importence of condensate policing unit in boiler).
Sure I'll make
Thanks you so much sir
Most welcome dear
Awesome sir
Thanks dear
👌👌
Thank you so much for your valuable video... Please make video on ZLD, MVR, MEE plants...
Sure I'll make
Hi Sir, Your videos are very interesting and informative. Could you please clarity that, how will you find out the pressure difference between input and output. Input pressure is Ok coming from high pressure pump. But for output pressure is it need to take from permit water pressure (or) Rejected water pressure? Thank you.
Outstanding explanation sir
Thanks dear
@@PowerPlantDiscussion16:14
Great job sir ❤️
Thanks dear
@@PowerPlantDiscussion sir number send me
Understood
Thanks❤
Sir please make video on startup procedure of
1- Lube oil system,
2- procedure of pulling vacuum in
surface condenser ,
3- Lineup cooling water
4- Heating of condensate turbine for
startup
5- Line up of gland condenser
6- startup procedure of back pressure turbine
7- Reset of turbine in field & DCS
Please sir make videos on these topic shortly
{Ultimately sir full start-up procedure Of Boiler Feed water pump in various part}
🙏🙏🙏🙏🙏
Sure dear I'll make
And you must check my playlist of turbine I have already uploaded some topic as you mention
Sir please make a video for HSRO system &all details
Dm plant interview ka video banao sir
Multi effect evaporator plant information video
Sure
V informative video Sir thanks for giving your best
Kindly deliver a video on UF(ultra filtration) too.
Make me sure Sir...
How many and what kind of chemicals we use in RO??
What is percentage of reject water of permeate water??
Dear I have already uploaded on UF please check my playlist of DMP
Sir Dm plant side water quality measure in cubic meter boiler side water measure in tons why , at two seuction water same mediam.
Sir make a video from edi unit all details
What should be flushing water pH after caustic soda circulation
why we use high ph solution or low ph solution in flouling ans scaling
Will you share some information related to ETP aerobic and anaerobic process
Sure I'll make
Sir uf ro inlet ka pressure kitana hota he
cooling tower ka dosing rate kasy nikalty hain
Sir aap ke sabhi lecture nice he sir aap written ka pdf bhi banaho
Dear pdf to ni bnaya hu
Sir mera ro 3000hr ka h aur TDS bilkul mentaion hai 3 saal ho gye h bs uske pressure bad gye h feed pressure 15 kg aur reject 13kg ho gya h mene cip bhi Kai baar karba Li h lekin koi asar nhi pad rha h membrain pe ab aap btao sir kya karu me pressure kaise drop Karu kafi Paisa kharch ho chuka h cip karba karba ke plz sir reply jarur karna aap
10000 se 12000 TDS ka Raw water hain to scaling hoga ya falling
Thanks sir for your informative video. Sir, I have one question why do not stop 72 hourse after operation .
ph will be high
Design of generation to distribution system design
Sir mera tds sahi aa raha hai or pani bhi sahi aa raha hai lekin pani Mai 2-3 hour Mai smell aane lagti hai to kya problem aa rahi ap bata sakte hai
How to set RO antiscalant dosing ppm
sir, chiller pe bhi video banaye , troubleshooting 🙏
Sure dear I'll make
Etp ro diagram banai hai na. Digger ka kya work Hai har Ro me
Kitna lph ka plant he
Bhai 40 8040 mein kitne kg ka pressure Dena chahie
R.O PLant me recycle q dete hai?
Sir RO me CIP karne ke baad bhi flow proper nahi mil raha hai or pressure vi drop nahi ho raha hai.
Pressure increase ho Raha hai aur flow down ho Raha hai to kon sa cleaning karenge
Membrane feed pressure ²nd stage pressure reject pressure how to calculate delta P please bataiye formula
If feed water temperature too high or low, what effect in boiler
Too high temperature above saturation form steam inside economizer which is known as steaming type of economizer
Low temperature increase fuel consumption
Turbine swing check p video baniye
Sure I'll make
Sir could you explain which type of membrane are used there and what is the size of membrane 8040 or 4040 further how much tds of water.
Filmtec SW30XLI -440i
Bhai koi book 📖 aati h kya Etp ro mee ki
🔅WHAT IS PURPOSE OF BEARING CHAMBER EXHAUST FAN IN HYDROGEN COOLED GENERATOR 🔅
Ro water treatment plant me Abhi FSSAI licence Ko update karne ke liye ..Abhi sarkar ne niyam Badal diye hai.abhi ek technician ka number Dena jaruri hai..jiska is field me certificate ho.. taki minerals ka matra o set rakhe ..aapka is field ka certificate hai kya..aapka jo charge Banta ..o Mai pay karne ke liye ready hu
Thanks sir cation keya karta he
Positive impurities like Ca, Mg, Na trapped by SAC.
Ro ka permit Nahin Badh Raha Hai
Sir apki sabhi classes le kr kya main interview ke liye ja skta hu... Plz sir reply me
Ha jarur ja skte h
AFTER CIP we can't get results then what to do?? And one membrane cip skid ???
After CIP we definitely get results but if not retrieve it means membrane got damaged may be replaced.
@@PowerPlantDiscussion Result got water parameters change like conductivity high silica increase and membrane okay weghit profile okay but problem not short out.
@@PowerPlantDiscussion Bwro he
Feed pr 13.2
Second stage-8.3
Third stage-5.3
Reject 4.0
Already CIP done within a week..but. No change found.
After CIP these data shown your membrane pore size increases still your membrane having fouling and scaling after prediction of pressure in each stage, your membrane must be replaced.
@@PowerPlantDiscussion thank you sir,
Sir Mai RO operator hu
Mere ro me Ek problems as gaya h
Pahale ham memberan me 9 kg ka inlet presar dalata tha aur out let 9kg
Nikalata tha us samay mujhe permit 18 aur reject 6 Nikalata tha
Abhi ro aadhe ghante chalane ke bad achanak presar inlet 12 aur outlet bhi 12 Ho jata h
Hame permit 16 aur reject 8 milanta hai
Ab is samay hame kya karana chahiye jisase mera ro Pahale jaisa chalane lage
Dear kv v inlet aur outlet pressure same ni ho skta h, gauge m problem hoga, agr apka inlet bhadh rha h aur same time m permeate flow decrease ho rha h yani membrane m fouling ya scaling hua h, outlet pressure gauge check krwae and aur permeate flow decrease hone lage to CIP kr lo ek br
Please check the major value
कौन समझदार कहता है कि आरो का पानी नुकसान करता है
Plzz Sir replie my question
Jaha sirf 1 stage ho waha kaise predict krenge sir
Oha pe apka jyada chances fouling ka hota h and pani m salt to h hi yani salt ka v deposition hoga yani small amount scaling v hoga, CIP k dauram low and high pH clean krwa lijie
Thank u sir..Main bhi DM plant pr hoon yaha 25 ton R.o lga hai single stage..iska t.d.s and conductivity Raw water ke brabr ho gya hai.. c.i.p se sahi ho jayega na sir?
Ha ekdm sahi ho jaega
Drawing is not clear sir
Hlo video ko atna lamba kyu krta ho ak hi baat ko 10 bar bol rha aap
It's very boring for knowledgefull person please don't cover normal point
So please share your knowledge