Very good sir I have continue watch you video . I want hydraulics open loop curit or close curit different between pls explain sir .but I am working in dubai
Pls help me. I'm From Bangladesh Our injection machine are accumulator pressure problem. Some times this pressure is Super High or very low for that case we can't running machine
First check below Check step by step 1. Step 1 - Check the accumulator nitrogen pressure ( Time of switch off the hydraulic motor and discharge main line hyd pressure ) 2. If found accumulator nitrogen pressure low then change the nitrogen ( during charging of acc switch off the motor and discharge the pressure ) 3. After accumulator inspection need to visit the line to check the sound from valves like internal leakage . 4. If some where drain open then also same will happen . check circuit and close the drain valves . ( drain valve of acc valve stand and p to T line drain valve check ) 5.Power pack heat exchanger water line strainer clean and also check pump is running or not . Also check the cooling water line inlet and outlet temp . cooling water line temp should be 25 to 28 degree
Good knowledge tks sir
Very nicely explained
Thanks for liking
Nice
Very good sir I have continue watch you video . I want hydraulics open loop curit or close curit different between pls explain sir .but I am working in dubai
Thankyou for watching
If possible kindly make video on hydraulic thruster of rotary kiln
Ok, Thanks for your suggestion
The only video on TH-cam and I can’t understand it. 😢
Pls help me. I'm From Bangladesh
Our injection machine are accumulator pressure problem.
Some times this pressure is Super High or very low for that case we can't running machine
First check below
Check step by step
1. Step 1 - Check the accumulator nitrogen pressure ( Time of switch off the hydraulic motor and discharge main line hyd pressure )
2. If found accumulator nitrogen pressure low then change the nitrogen ( during charging of acc switch off the motor and discharge the pressure )
3. After accumulator inspection need to visit the line to check the sound from valves like internal leakage .
4. If some where drain open then also same will happen . check circuit and close the drain valves . ( drain valve of acc valve stand and p to T line drain valve check )
5.Power pack heat exchanger water line strainer clean and also check pump is running or not . Also check the cooling water line inlet and outlet temp . cooling water line temp should be 25 to 28 degree
Which types of motor pump
What's DCV logic valve
Direction control valve ladder logic in PLC
Ok will se
Bhai system chalane ke 30 second baad system slow horaha hai pressure ko develop hone ko time lag raha hai kya problem ho sakta hai
Pressure drain ho raha hai kahi se .please check the drain line valve should be close
Please hydraulic drawing to mail id , shibashis2008@gmail.com
good job but can't understand the language
Hi
You Tried to explain but it is not proper..... Many loop holes in explanation and mostly not understood