    You made this hard work by cutting the cables so short a good tip would be when u have striped the cable pull the wires to the furthest corner of the box and cut the live and neutral afew millimeters longer and then the Earth's a few millimeters longer than that.
    If the cables come through different points of the box take the striped wires to there furthest corner this may be different corner it's might also be the same e.g. cable comes in at the top left so take the striped wires to the bottom right.

  • @aggro4e
    @aggro4e 2 ปีที่แล้ว +4

    whyyyyyyyyyyyyyyyyyy why did u chop the cables sooo short???

    • @kenpyne
      @kenpyne 11 หลายเดือนก่อน

      😢😊😮😊😅😮

  • @martinlewis1015
    @martinlewis1015 5 ปีที่แล้ว +43

    You cut the wires too short so if you need to take socket off for work like tiles or if damaged you will have no play

    • @zerosparky9510
      @zerosparky9510 5 ปีที่แล้ว +3

      in the States, the NEC is that you leave at least 6 inches of free wire from back of the box. don,t think it has changed in recent years. the NEC undergoes changes every 3 years.

    • @007JHS
      @007JHS 4 ปีที่แล้ว +1

      Yep.

    • @5chrisy
      @5chrisy 4 ปีที่แล้ว +4

      Nothing wrong with the wires its perfect!

    • @martinlewis1015
      @martinlewis1015 4 ปีที่แล้ว +3

      5chrisy are you an Electrician

    • @5chrisy
      @5chrisy 4 ปีที่แล้ว +2

      @@martinlewis1015
      No but as you know you can pull them down from the wall,
      They look fine to me,
      Plus perhaps he knows hes not going to remove it again!

  • @streamiumlive
    @streamiumlive 2 ปีที่แล้ว +23

    I hadn't expected to learn so much. Lots of great tips. I suppose the only thing missing is to remember to not deal with live wires. But if people didn't realise this by now, they'd probably not be around to watch your video. Great stuff!

    • @michaelgalvin6491
      @michaelgalvin6491 2 ปีที่แล้ว

      I have one that's not working? Looks new? Is there a fuse inside?

    • @jutke666
      @jutke666 11 หลายเดือนก่อน

      Thanks a lot ❤

  • @winphoenix1136
    @winphoenix1136 ปีที่แล้ว +5

    Thank you. The live and neutral were opposite to the one I removed from the wall. I'm so glad you mentioned that this might happen (7.08 in the video). Now I am quite confident in replacing the unit. Thanks too for talking about the different colours, depending on when the house was built / wired (2006). That was extremely helpful. I'll just watch your video again, to be sure.

  • @DerekHundik
    @DerekHundik 3 ปีที่แล้ว +5

    i can't watch this it hurts

  • @johnsouthern1493
    @johnsouthern1493 5 ปีที่แล้ว +9

    Not even a tug test...tut,tut.

  • @ianbarber6463
    @ianbarber6463 3 ปีที่แล้ว +6

    Cables I always go 25mm past bottom of box at least. And cutting across CPC and Line/Neutral you will trip any RCD/RCBO and drop out power to other circuits.

    • @rorywestfold1657
      @rorywestfold1657 3 ปีที่แล้ว

      Can you explain what this means to a layman please? CPC? How has he cut across anything?

    • @ianbarber6463
      @ianbarber6463 3 ปีที่แล้ว

      @@rorywestfold1657 CPC is Electrician speak for EARTH. Circuit Protective Conductor.

    • @sr94uk49
      @sr94uk49 2 ปีที่แล้ว

      This is a super late reply but I think he's referring to, if working on alive circuit, cutting all the wires at once would cause a short circuit due to the conductivity of the cutting tool

  • @72megasnoopy
    @72megasnoopy 4 ปีที่แล้ว +4

    I’ve got 2 Earth points On my double socket plus 2 earth wires . Can I connect both Earth wires to One point Or must I connect each wire to each earth point ?

    • @hbarnes2489
      @hbarnes2489 4 ปีที่แล้ว +2

      You can put them both in one earth terminal or one in each it's up to you. However in some situations the earth might be short so might only reach to one point any way.

  • @salahsindi5234
    @salahsindi5234 4 ปีที่แล้ว +5

    you left the wires too short.

    • @5chrisy
      @5chrisy 4 ปีที่แล้ว

      Perhaps he Wants them like that

  • @kingofthetrowel1725
    @kingofthetrowel1725 3 ปีที่แล้ว +2

    Does it need testing and a minor works certificate issuing , R1+R2 and zs values . Justin’s wanting to know before I do it myself and void my house ins

    • @kingofthetrowel1725
      @kingofthetrowel1725 3 ปีที่แล้ว

      @Faster Hard House brilliant just what I wanted to know, I’ll get the pros in to fit sockets and light fittings from now on, I see many DIYers going for it but when it comes to them selling the house they end up in all sorts of trouble when the solicitors ask questions 👍

  • @xhibitgamer1027
    @xhibitgamer1027 3 ปีที่แล้ว +5

    Great video mate I’m currently doing a lvl 2 diploma in installations and thus helped a lot

  • @richis9070
    @richis9070 5 ปีที่แล้ว +4

    This what I was exactly looking for..cheers mate👍👊

  • @oohtob6685
    @oohtob6685 4 ปีที่แล้ว +4

    Can you not put both earths in 1 sheath?

  • @peternorman2563
    @peternorman2563 4 ปีที่แล้ว +3

    Not very professional when stripping the outer covering also leave at least 6" for the tails.

    • @007JHS
      @007JHS 4 ปีที่แล้ว

      Yep! .... I'm not a professional and even I can see that.

  • @vickiowens8302
    @vickiowens8302 3 ปีที่แล้ว +5

    Really helpful, thank you! I was unsure as to whether it was ok to put the 2 lives together in one port, the 2 neutrals together and 2 earths together (more confused by the earth as there are 2 earth ports on my new socket, one on each side, so was wondering if I had to split them. This is really well explained and shows, thanks!

    • @troycallan4776
      @troycallan4776 3 ปีที่แล้ว

      i guess I'm quite randomly asking but do anybody know a good place to watch new movies online ?

    • @armandotimothy3921
      @armandotimothy3921 3 ปีที่แล้ว

      @Troy Callan Flixportal :D

    • @troycallan4776
      @troycallan4776 3 ปีที่แล้ว

      @Armando Timothy thank you, I signed up and it seems like a nice service =) I appreciate it!

    • @armandotimothy3921
      @armandotimothy3921 3 ปีที่แล้ว

      @Troy Callan you are welcome xD

    • @pauldooley756
      @pauldooley756 2 ปีที่แล้ว +1

      Flipping Heck. Ok

  • @ronoc9
    @ronoc9 21 วันที่ผ่านมา

    Just had to fix one at home. Why do you not split the Earth and have them both in the two slots?

  • @roxbrown11
    @roxbrown11 หลายเดือนก่อน

    I have just bought an old item and it has 4 wires. What do I do with this ? 0:57
    Thanks !!!

  • @AdamK0055
    @AdamK0055 3 ปีที่แล้ว +1

    why not ad just one hot and one neutral to this double socket. some times up to 5 average sockets can share one wire.

  • @fabiandee8178
    @fabiandee8178 4 ปีที่แล้ว +2

    Do you not bother to fold the ends of the wires in half before inserting them into the terminals? Some say it is necessary, but it makes it much harder to insert them esp. if you have 2 wires into one terminal.

    • @encrypted7227
      @encrypted7227 4 ปีที่แล้ว +6

      if its two cables then you shouldn't need to fold the ends, but if theirs only one cable its a good idea to fold the ends because it gives a better connection.

  • @davebaldwin340
    @davebaldwin340 3 ปีที่แล้ว +2

    That was nice and easy really well explained thanks for a great video

  • @Nairobi_Finest.
    @Nairobi_Finest. 6 หลายเดือนก่อน

    Is it possible to connect a 2 gun switch from one wire instead of two

  • @VeritasAequitas178
    @VeritasAequitas178 3 ปีที่แล้ว +1

    Thanks for video. I am wiring a fridge and heater to an STC 1000 temperature controller. Can I use the same type double socket to connect them to the controller, i.e. is that safe?

  • @paddlingmatlockmichaeldavi1839
    @paddlingmatlockmichaeldavi1839 2 ปีที่แล้ว +1

    Hi .. Thank you.
    I just successfully wired up my daughter's plug socket and it now works. I followed your video step by step and it was great. Many thanks. 😁

  • @fauzee
    @fauzee ปีที่แล้ว

    I have only three wires difference from the video

  • @SuperROGNES
    @SuperROGNES 8 หลายเดือนก่อน

    Is it necessary to use two wire cables?

  • @oldwebshooter
    @oldwebshooter 3 ปีที่แล้ว +1

    Why is the Earth wire bare and not shiethed from get go?

    • @jamesantill5065
      @jamesantill5065 3 ปีที่แล้ว

      For a start it makes the sheathed cable that much fatter.

    • @johnbarratt983
      @johnbarratt983 3 ปีที่แล้ว +1

      Because if the cable is damaged you want the earth uncover first then any short will be hopefully to the earth and not through you.

  • @adamsharp201
    @adamsharp201 2 ปีที่แล้ว

    You are not showing us how to WIRE a double socket. Only showing how to CONNECT a double socket.

  • @spencerkeith6091
    @spencerkeith6091 ปีที่แล้ว

    Quick question. Can I connect a double socket with T&E and put a plug on the end of the T&E and plug it into a separate socket. So basically making the double socket an extension lead

  • @mattuttley3711
    @mattuttley3711 7 หลายเดือนก่อน

    I'm colour blind tho

  • @aisoellyenock
    @aisoellyenock 8 หลายเดือนก่อน

    😂😂Thank you very much.
    Successfully installed mine by myself

  • @kevinburke544
    @kevinburke544 2 ปีที่แล้ว

    Only have one multicore cable running Down to the double socket would that surfice

  • @EdwardChabinga-il3ij
    @EdwardChabinga-il3ij ปีที่แล้ว

    Why haven't you put live, earthing and neutral on both sides??

  • @UnforeseenTruth
    @UnforeseenTruth 2 ปีที่แล้ว

    What if you dont have an earth? I have a two socket and 4 wires and what messed up is all the wires are red. The electrical wire coloring in this house was done badly. And im trying to switch it out to a double universal. Both socket was wired with like a bridge from left to right with the original setting. So I dont know if it will work if i remove that bridge conection.
    I have 2 Nuetral holes on the top and 2 Live holes on the botom so they are parallel to eacother. Plus only one wire can fit per hole, not two.

  • @Hunter-gb7fn
    @Hunter-gb7fn หลายเดือนก่อน

    Thanks ❤

  • @mohammadshamshadalam2328
    @mohammadshamshadalam2328 ปีที่แล้ว

    Awesome video but little long wire must be in side socket for future plan

  • @FreeImranKhanPM
    @FreeImranKhanPM ปีที่แล้ว

    You didn’t mention that main switch should be off first

  • @jean-lucpicard5510
    @jean-lucpicard5510 ปีที่แล้ว

    God knows why they removed the sleeve on the neutral wire on the new standard.

  • @Lukes-go1xv
    @Lukes-go1xv 2 ปีที่แล้ว

    Hi I've bought a dreaded new build and I only have 1 earth wire one a double socket. Is this safe/normal practice. Tia

  • @matthewwallace7751
    @matthewwallace7751 2 ปีที่แล้ว

    Those conductor wires are way too short. Conductor wires that are too short can cause them to come loose a lot more easily. Plus if anyone had to do future work it's good practice to leave enough length for them to cut back if they needed to.

  • @freddiemaq2186
    @freddiemaq2186 5 ปีที่แล้ว +2

    Thank you for your helpful video!

  • @methedevilagartha5684
    @methedevilagartha5684 ปีที่แล้ว

    extra cable loop is missing but still good goodluck

  • @richardfrench8879
    @richardfrench8879 2 ปีที่แล้ว

    Those cable are too short, if that outlet had to be replace with a different connection position. The guy replacing it is gonna look silly because the cables don't reach. I wish I had a pound for how often that's happened to me.

  • @Gunzee
    @Gunzee ปีที่แล้ว

    I have 4 wires going into each hole & it's nearly impossible to get the live side in. The guage is lower than the ones in video.

  • @beimmortal-gymmotivation4245
    @beimmortal-gymmotivation4245 2 ปีที่แล้ว

    Hi bro. Blue cable: Notr, Brown: Phase. Correct ?

  • @tenaciousdjt
    @tenaciousdjt 9 หลายเดือนก่อน

    Big thanks buddy, fitted me a single socket for a new cooker hood extractor!! 🤜🏼🤛🏼

  • @kinghabib2770
    @kinghabib2770 2 ปีที่แล้ว

    I have done this I I’m struggling to close my box as the electrical wires are to strong to bend in box also I have cut the wires down

  • @alberttaylor3917
    @alberttaylor3917 2 ปีที่แล้ว

    Often one the other cable isn't grabbed by the screw, whats the fix .

  • @peterward8308
    @peterward8308 3 ปีที่แล้ว

    They are conductors not cables and cpcs not earthing cables. Why you have cut those conductors so short is absolutely beyond me, I think you need to sharpen your skills if you are going to post on TH-cam because from this you make yourself look totally unskilled.

  • @ich1978
    @ich1978 2 ปีที่แล้ว

    Thank you very much. This was great how to video clip for home DIY. Simple to understand. 👍

  • @Tselectricals
    @Tselectricals ปีที่แล้ว

    Very helpful presentation bhai ❤❤❤❤

  • @kierzo8543
    @kierzo8543 ปีที่แล้ว

    Amazing thank you, the only concise video I've found !

  • @jjingoismael298
    @jjingoismael298 ปีที่แล้ว

    Did he speak Luganda🙊 easy.. mpola.. but hey thanks

    • @peterstayne3765
      @peterstayne3765 11 หลายเดือนก่อน

      Oli otya from a muzungu 🇬🇧

  • @ashishsaha3756
    @ashishsaha3756 5 ปีที่แล้ว +1

    Thanks for the video, can I loop from this socket for a new 1 gang box by the side for a new connection to a light bulb?

  • @tomnewtnt5718
    @tomnewtnt5718 4 ปีที่แล้ว

    Czemu u was nie produkują kabla PN w izolacji ? Czemu u was do jednego gniazdka idzie po 2 kable?

  • @Crossdjinthemix
    @Crossdjinthemix 4 ปีที่แล้ว +1

    This was very informative

  • @wmursai
    @wmursai 2 ปีที่แล้ว

    Why you not socket turned on 🤬

  • @ethnasmith998
    @ethnasmith998 2 ปีที่แล้ว

    Very well explained ...your a good teacher

  • @ahmedkhaled2976
    @ahmedkhaled2976 2 ปีที่แล้ว

    You guys so semple teaching I love to see more video from you .

  • @MrAppukuttan93
    @MrAppukuttan93 2 ปีที่แล้ว

    I have only one wire coming out of the wall similar to the one shown in the video. Can I use it to power twin sockets?

  • @mikehumphs1124
    @mikehumphs1124 4 ปีที่แล้ว

    and with the faceplate facing towards the camera, you see naff all

  • @jamshedrizae4987
    @jamshedrizae4987 2 ปีที่แล้ว

    Can anyone tell me why there are two live cables? Some of my living room's socket have two live cables and some of them has one???

    • @justjosh11
      @justjosh11 2 ปีที่แล้ว +3

      If it's on a ring main then it will have two cables connected to it; each cable going to the adjacent sockets in the ring.
      If it's only a single cable then it most likely is on a spur.
      I'm not an electrician so open to being corrected, but think I'm right in this

  • @harrisonswayne
    @harrisonswayne 3 ปีที่แล้ว

    With the earth at the end after the sleeve is on, don’t you need to bend it up ??

  • @5chrisy
    @5chrisy 4 ปีที่แล้ว

    Very good video,
    Helpful thankyou

  • @vortex1455
    @vortex1455 5 ปีที่แล้ว

    Should pull earth with pliers and pull it at a 30 degree angle for a easier stripping of a sheath

  • @yousifsuliman2446
    @yousifsuliman2446 2 ปีที่แล้ว

    Do you have a link to these tools ?

  • @hussainsalah890
    @hussainsalah890 4 ปีที่แล้ว

    what if my thumbs are smalr than yrs ?

  • @DeanW-1990
    @DeanW-1990 ปีที่แล้ว

    Very useful thanks mate

  • @gordonwalker7792
    @gordonwalker7792 3 ปีที่แล้ว

    He made that look easy(!)Great video 🤔😀

  • @harryesteves387
    @harryesteves387 3 ปีที่แล้ว

    I should know this but why are there are there TWO cables going into the box????

    • @harryesteves387
      @harryesteves387 3 ปีที่แล้ว

      Because it’s a double socket so it needs double the flow???

    • @seedy1959
      @seedy1959 3 ปีที่แล้ว

      because it is on a ring main, only one set of wires on a spur

    • @bairdybee
      @bairdybee 2 ปีที่แล้ว

      So can this be done with 1 set of wires in a double socket ?

    • @samjburns07
      @samjburns07 2 ปีที่แล้ว

      @@bairdybee if it's a radial and there's no sockets being fed off it, yes

  • @colerumpel
    @colerumpel 4 ปีที่แล้ว

    Here in Canada (and the states) the wire colours are black being live, white being neutral, red being a secondary live or a traveler for three way switches, and bare copper or a solid green being earth. to strip the cable you measure the wire with your index finger and your thumb lengthwise against the insulation of the wire, then make a cut around the insulation where the top of your index finger was. After the cut is made the wire is cut down from previous cut to the end of the wire, and you peel off the insulation like opening a banana with your fingers. (This is all done before putting the wires in the box) the cable is clamped down with the restraint inside of the box and the ground (earth) wire is half looped around the ground screw at the back of the junction (back) box and is looped around the ground screw of the socket. The live and neutral are stripped and can either be inserted into the holes on the back of the socket or looped around the screws on the sides. We strip the wire differently because the cables in north America are split into two by a lengthwise trench running down the middle of the cable.

  • @nigelhunter4230
    @nigelhunter4230 3 ปีที่แล้ว

    Superb demo. Thankyou Sir.

  • @TheZohri
    @TheZohri 3 ปีที่แล้ว

    Thank you. Well explained. It will help me a lot

  • @kashifsaleem3713
    @kashifsaleem3713 3 ปีที่แล้ว

    thanks for help😍

  • @ElectricEssenceLtd
    @ElectricEssenceLtd 4 ปีที่แล้ว

    Great video Owen. Please upload more

  • @ansarizahir7597
    @ansarizahir7597 2 ปีที่แล้ว

    Thanks a lot sir

  • @mr.berlingo8211
    @mr.berlingo8211 5 ปีที่แล้ว

    Much the same as how to wire a single socket.

  • @gijoe5313
    @gijoe5313 4 ปีที่แล้ว

    thank you for the video

  • @jamesyahya2897
    @jamesyahya2897 2 ปีที่แล้ว

    great👍

  • @myheaven2626
    @myheaven2626 2 ปีที่แล้ว

    May i know how many double socket can be connected on a 2.5mm cable.

    • @JL-rx6hl
      @JL-rx6hl ปีที่แล้ว

      depends on the mcb/rcbo capacity that is feeding the sockets. in theory it could be hundreds as long as the combined load is less than the supply

    • @murphyjp30
      @murphyjp30 ปีที่แล้ว

      That's completely wrong the max is 5. If you put in a bigger mcb than 20amps on a 2.5 cable if the load is higher than 20amps it will work but the cable will heat up like an element because mcb is too big for a 2.5 cable and it 100% will cause a fire. Don't take any advice from this guy he has no idea what he is talking about. I know he's not a qualified electrician by how short he cut the cable no electrician would do that. And that is not the correct way to terminate the connections it's much more likely it will cause a loose connection in the future. Loose connections are the cause of 90% of all electrical fires in ireland. Our regulations are the same as the UK

  • @shinomaru83
    @shinomaru83 3 ปีที่แล้ว

    Thanks

  • @adycee2915
    @adycee2915 4 ปีที่แล้ว

    Bit late to ask, but did the pattress have 20mm knockouts or have you drilled the box for the gland? Cheers

    • @acvideos671
      @acvideos671 4 ปีที่แล้ว +1

      I am yet to find a plastic pattress with side knockouts :(

    • @adycee2915
      @adycee2915 4 ปีที่แล้ว +1

      @@acvideos671 Hi Amy, I try to steady the plastic around a block of wood viced/clamped. Varying degrees of success. Pillar drill best 😉

  • @zulfakarali6274
    @zulfakarali6274 3 ปีที่แล้ว

    Thanks

  • @hodzikujohnson7954
    @hodzikujohnson7954 3 ปีที่แล้ว +2

    This has helped me a lot,l will like to learn more

  • @fabiansasi1767
    @fabiansasi1767 4 ปีที่แล้ว

    Tq man u save my time

  • @andrewgray9663
    @andrewgray9663 5 ปีที่แล้ว

    Some explanation of where th 2 T+E cables came from would have helped

    • @Tokaisho1
      @Tokaisho1 5 ปีที่แล้ว

      It'll be on a ring circuit here

    • @acvideos671
      @acvideos671 4 ปีที่แล้ว

      He did say its from a ring circuit

  • @8430jamie
    @8430jamie 5 ปีที่แล้ว

    Good video

  • @CurvedSlightly
    @CurvedSlightly 5 ปีที่แล้ว

    Good video

  • @moedem
    @moedem 5 ปีที่แล้ว

    Cheers dude

  • @oldgrunger5
    @oldgrunger5 5 ปีที่แล้ว +2

    Rough bro 🤣🤣🤣

  • @1987yuksel
    @1987yuksel 4 ปีที่แล้ว +1

    Hi guys can I use electric tape for Earth ?

  • @samjuner
    @samjuner 3 ปีที่แล้ว

    Thanks for posting this, Owen. 👍

  • @Eatbeans6739
    @Eatbeans6739 3 ปีที่แล้ว

    Thanks. Helpful video. I’m going to be doing this later, so this is just great. I noticed that you didn’t say at the beginning, to make sure the supply is off. I know that one should be reasonably competent, but would have been good to hear, just for reassurance. Just an observation, not a criticism. Again, thanks.

  • @Spark101.
    @Spark101. 3 ปีที่แล้ว

    Your version of installing a double socket is amateurish at best. You have made several mistakes.
    My advice......leave it to the professionals. Not only are you promoting DIY electrics, you are promoting bad practices.

    • @rugbyluke8
      @rugbyluke8 3 ปีที่แล้ว

      What were the mistakes?

    • @Spark101.
      @Spark101. 3 ปีที่แล้ว

      Give Gary from efixx a watch. You’ll see the difference.
      It’s not a bad effort.....but not professional. And by the way, I am a professional.