Good morning, when inverter and frequency converter is used and the three-phase compressor, no capacitor is used, the capacitor is used only in single-phase or two-phase compressors for phase correction at start-up and to keep the torque running. Buenos dias, cuando se utiliza inverter y variador de frecuencia y el compreosr de tres fases, no se utiliza capacitor, el capacitor se utiliza solamante en compresores monofasicos o bifasicos para la correccion de fase en el arranque y mantener el par torque en marcha.
He Is Demonstrating That How Input Frequency Changes The Speed Of The Motor Means That The Compressor's Motor Is Asynchronous Motor And Its Speed Depend On The Frequency Not Voltage So He Just Changing The Frequency From 10 Hz To 60 Hz And See How It Affects The Speed Of The Compressor's Motor That's It
@RS videos Nahi Bhai Motor Khraab Nahi Hogi But Isme Frequency Ko Up-Down Karaa Hai Voltage Ko Nahi Agar Voltage Ko Up-Down Karoge Tab Ho Sakti Hai But Chances Bhot Kam Hai
So what is your conclusion, below 60hz the lubrication is inadequate? Another question, im looking for hacking my own refrigerator to control its original compressor with an inverter module, i have a good technical knowledge, but never worked practically with refrigeration compressors, in your opinion its feasible?
inverter type AC like LG uses 3Phase motor and and a controller(frequency), and most of old AC has single phase motor therefore it is not possibles to connect the motor to the inverter module.
Realmente debe actuar sobre las dos variables, voltaje y frecuencia, pues ambas interactúan de una manera compleja en estos motores. Hay mucha teoría y matemáticas detrás de los variadores de frecuencia.
hi. we have a refrigerator that has inverter compressor. but the sound is so loudly according to old one. like 57 dB while working normal speed. if gear up then getting much more like 60 -65 dB. this is normal for inverter ones?
111 elektro111, Hi1, i have compressor but don't know if 1 or 3 phase. And VFD (1ph to 3ph) terminals; which are U-V-W, to connect in my compressor wiring Red-Black-Brown. My question is Which wire is which wire? Thnk for the feedback
The thumbnail tho, seems creepy. It kind of reminds me of those Fembots, from the '70s TV series "Bionic Woman / Fembots in Las Vegas" episode(s), without their faces attached. The eyes were so freaky... and without the face covering, they never turn when it started to attack you. Dead eyes they were. Soulless automatons, but ahead of their time.
Brother is me ap ne input 3 phase use ki jab k out put 2 phase use kr rhe hn. To is se inverter ko problem ni ho gi Kia?.... Or 2sri bat ye k is k output voltage ki setting kitni krni pare gi....
This video showind us, that compressor will have lubrication problems if frequency below 30Hz. As it not optimized to run at frequency less than 50\60 Hz.
in Pakistan technicians are making old split ac units into DC inverter .. to control speed of compressor.. is it possible? and does it have any effect on compressor life>>
its posible, but espencibe, complicated and not reliable. the compresor desing have a tolerance of 30% of speed, beyond that has apear a lubricity and fatigue problems.
Antonio, como puedes ver las dos fases se rectifican a CD y se aplican a un PWM ( Modulador de Amplitud de Pulsos donde se convierte a trifasica y le permite variar la frecuencia desde los 53 Hz cuando el motor gira a 1200 rpm pero cuando el control del sensor de temperatura se ajusta para que genere mas frio el PWM puede variar hasta los 130 Hz con lo que sube la velocidad hasta 3200 rpm creando mas frio. Como puedes ver el motor nunca se detiene solo cambia su velocidad.
Inverter compressor are thre phses AC motors but in home are only one phase, so it rectify Ac and convert to DC that is applied to a PWM (Pulse Width Modulator) that not only are in 3 phases but can vay frequency from 53 Hz when motor has 1200 rpm to 130 Hz when goes to 3200 rpm.
thanks for reply, what about voltage? Do you think that any or most of home (one phase) fridge compressors can be powered from variable frequency drives?
witam, po naszemu będzie prościej. Co do napięcia do dokładnie nie pamiętam ale raczej było obniżone na falowniku bo to był IG5 na 400V. Raczej nie ma problemu z zasilaniem z falownika ale w rozsądnych granicach aby nie było problemu ze smarowaniem. Oczywiście mówimy o sprężarkach tradycyjnych a nie o iverterach. pozdr.
a jakiego rodzaju tam jest silnik? bo widywałem przy lodówkach różne patenty do rozruchu, silnik ewidentnie bezszczotkowy, a w takich przy jednej fazie są zawsze kłopoty ze startem. Pytam między innymi dlatego że miałem dobrać UPS do lodówki i przez prąd startu trzeba było znacznie większej mocy ups'a. Próbowałem ją puścić przez regulator na triaku, ale nie miała siły wystartować i ten motyw z falownikiem mnie zaciekawił, a znów nigdy nie trenowałem innych silników z falownikiem niż pracujące w trójkącie z szeregowym kondensatorem, czyli asynchronicznych trójfazowych.
silnik jest bezszczotkowy, układy rozruchowe raczej robią to samo , jest tam kondensator rozruchowy i zabezpieczenie sprężarki. tu na falowniku ładnie rusza prawie od 0 Hz ale sprężarka jest nieobciążona. Jak pracuje w normalnych warunkach to rozruch jest znacznie cięższy. Często przed wyrównaniem ciśnień wcale nie ruszy. Co do startu z przetwornic i zasilaczy z doświadczenia wiem że chinole się palą albo nie są wstanie ruszyć maleńkiej sprężareczki i trzeba sporo przewymiarować zasilacz
سلام . موتور یخچال مورد ازمایش اینورتر سه فاز میباشد . دستگاه که ان را تست میکنید درایور اینورتر برق صنعتی از تک فاز به سه فاز میباشد که بالا و پایین کردن فرکانس دور موتور تغییر میکند
Hello my Ac compressor is running but why starting 5 minutes after then is compressor sound coming and not cool only hit coming but compressor is also running and hit coming why
The a/c is working with few pcb. And everything is being controlled by them. After u run the system all sensors are sending signals to control board and then compressor will starts and if it’s inverter will start from low speed, depend on demand will speed up
Nice!!! Looking forward to seeing what projects you have in mind for this!
Hello, it would be great if you could explain the wiring between the compressor and the inverter. Also, are you using a capacitor?
Good morning, when inverter and frequency converter is used and the three-phase compressor, no capacitor is used, the capacitor is used only in single-phase or two-phase compressors for phase correction at start-up and to keep the torque running.
Buenos dias, cuando se utiliza inverter y variador de frecuencia y el compreosr de tres fases, no se utiliza capacitor, el capacitor se utiliza solamante en compresores monofasicos o bifasicos para la correccion de fase en el arranque y mantener el par torque en marcha.
it would be nice if you told us what you are doing.
He Is Demonstrating That How Input Frequency Changes The Speed Of The Motor Means That The Compressor's Motor Is Asynchronous Motor And Its Speed Depend On The Frequency Not Voltage So He Just Changing The Frequency From 10 Hz To 60 Hz And See How It Affects The Speed Of The Compressor's Motor That's It
@@lakshaynarayan1853 ok but for wich elctric DC or AC?
@@frostcontrolhayder3463 Only AC Current
@RS videos Nahi Bhai Motor Khraab Nahi Hogi But Isme Frequency Ko Up-Down Karaa Hai Voltage Ko Nahi Agar Voltage Ko Up-Down Karoge Tab Ho Sakti Hai But Chances Bhot Kam Hai
@@lakshaynarayan1853 bhai ye kis cheej se chala raha hai ise
witch is better samsong smart inverter compressor or lg linear inverter compressor
thanks
Thanks for sharing this video. What is exactly the device you're using to start the compressor?. Is it a frecuency generator or a frecuency variator?.
Nice video 👍
From 🇮🇳
Which is the device which your using to control the frequency? Can i know the product name
So what is your conclusion, below 60hz the lubrication is inadequate? Another question, im looking for hacking my own refrigerator to control its original compressor with an inverter module, i have a good technical knowledge, but never worked practically with refrigeration compressors, in your opinion its feasible?
inverter type AC like LG uses 3Phase motor and and a controller(frequency), and most of old AC has single phase motor therefore it is not possibles to connect the motor to the inverter module.
OMG funny
@@baddybudds2128 why not? There are single phase inverters or three phase inverters can work on single phase.
Very cool VFD you have there! =)
Aparelho usado no teste ,,,INVERSOR CONVERSOR de FREQUÊNCIA SV004iG5A-2
This is an induction motor based compressor. Do you have any video of permanent magnet based compressors?
Yes. They won't work on VFD drives. 3ph Brushless driver is needed like for the latest hobby motors.
why they wouldn't work on vfd? the synchronous motors
because brushless are dc motors.
Yes, there are. But they still use commutation to fire the needed coils for right time. (Hall effect sensor)
Thats not true. The controllerr for compresor is dc. Te current in the motor is just 3 phase ac
Great informative video sir.. compressor
so the compressor speed is working based on input frequency not voltage is that correct?
Absolutely your right
Realmente debe actuar sobre las dos variables, voltaje y frecuencia, pues ambas interactúan de una manera compleja en estos motores. Hay mucha teoría y matemáticas detrás de los variadores de frecuencia.
In all frequecy drivers, when@low frequency the voltage is also low.
hi. we have a refrigerator that has inverter compressor. but the sound is so loudly according to old one. like 57 dB while working normal speed. if gear up then getting much more like 60 -65 dB. this is normal for inverter ones?
WELCOME. WHAT IS THE CONTROLLER? What voltage can it give at U V W?
Thank you friend. You teach me how many watt require for Fridge running on inverter. And this is unloaded compressor.👍👍👌
Jikarlohiya tell me sir about of invater camprseer
@@Masterofrefrigerator9756. simply inverter compressor has Ac three phase motor
@@shekharpawar7571 inverter compressor is bldc motor
Only 0.5kw inverter is enough.
Very good video... can you make video inverter vs non inverter refegerator
I think that white thing was to serve 2 purposes. One was to make it quieter and the other was to act as a vacuum reservoir.
How have you connected the vfd with compressor can you please share connection diagrams
Hello vaiya chak korar mashin ta ki pawa jai? N atr dam koto?
Your not using ester oil are you for the compressor? This method could be used for stuck compressor? Nice video thank you.
and what compressor model? if you remember
111 elektro111, Hi1, i have compressor but don't know if 1 or 3 phase. And VFD (1ph to 3ph) terminals; which are U-V-W, to connect in my compressor wiring Red-Black-Brown. My question is Which wire is which wire? Thnk for the feedback
Dammit, put it up to at least 100Hz!
131Hz danfoss sc 18 , Sorry for the low quality of the film,
Bờ tét block nay mua ở đâu vậy ban
no, looks weird because a controller frequency can only control the often a three-phase Motor and this does not appear to three-phase.
I was pretty sure you are going to fry this baster in a great finale. I may just watched too many TH-cam videos.
Is it made by yourself or you buy ?wheter you bought it,could you show me the store please?
The thumbnail tho, seems creepy. It kind of reminds me of those Fembots, from the '70s TV series "Bionic Woman / Fembots in Las Vegas" episode(s), without their faces attached. The eyes were so freaky... and without the face covering, they never turn when it started to attack you. Dead eyes they were. Soulless automatons, but ahead of their time.
This inverter has a smooth transition in frequency increase, why not to have this feature when decreasing frequency?
Acceleration time - ACC > 0 possible 0 - 6000s
Deceleration time - dEC = 0 possible 0 - 6000s
in LG ig5
VACUUM KYUN ZAROORI HAI??? ABTK KA SBSE ZABARDAST VIDEO.... @
Is it a single phase motor?
Is it three phase compressor?
Is it possible to run in closed loop, using af 4-20mA tansmitter ?
And how well does it run at +25% or -25% ? at 50Hz
Is it, CT or VT mode ?
Possibly, if I have time then I will record the movie
I only asked, to se the range..
Because, normally VLT controlled compressor, are quite expensive, and a little r134a hermetic, doesn't cost a fortune.
What is the brand of the compressor?
did you make changes to the coil?
no, coil is oryginal
Brother is me ap ne input 3 phase use ki jab k out put 2 phase use kr rhe hn. To is se inverter ko problem ni ho gi Kia?.... Or 2sri bat ye k is k output voltage ki setting kitni krni pare gi....
can we use a inverter for compressor motor operationally and really ?
This video showind us, that compressor will have lubrication problems if frequency below 30Hz. As it not optimized to run at frequency less than 50\60 Hz.
Looks like fridge compressor like engine has certain limit on min and max speed for vibration isolation.
in Pakistan technicians are making old split ac units into DC inverter .. to control speed of compressor.. is it possible? and does it have any effect on compressor life>>
soniaali487 what is possible invater camprseer how check direct with out invater pcb
its posible, but espencibe, complicated and not reliable. the compresor desing have a tolerance of 30% of speed, beyond that has apear a lubricity and fatigue problems.
Lucio Nicolas Also possible problems with oil returns from evaporator due to lower gas speed in the suction pipe.
Plus the valves may not operate correctly.
Kis n Bola old ac se inverter BNA rahy hn....aur kon se brand
Or is me kitne a pare ka difference par jata he...?...
I wanna know how you configure the vfd to works with a compresor with only two phases .
Antonio, como puedes ver las dos fases se rectifican a CD y se aplican a un PWM ( Modulador de Amplitud de Pulsos donde se convierte a trifasica y le permite variar la frecuencia desde los 53 Hz cuando el motor gira a 1200 rpm pero cuando el control del sensor de temperatura se ajusta para que genere mas frio el PWM puede variar hasta los 130 Hz con lo que sube la velocidad hasta 3200 rpm creando mas frio. Como puedes ver el motor nunca se detiene solo cambia su velocidad.
What is motor in the compressor. Inductor motor or bldc
Speed controlling device vfd hai kya
Hi sir
Where I get this type of 3 phase compressor
Are you use Ac or Dc power for this job?
AC Power
Bagaimana cara setting inventer yg awal dinamo nya berpotar tetapi baru 20detik dinamo nya mati sendiri?....
Aap ko Mubarak ho mana aap ka channel deekh lya .... Eid sa pehlay aap ki Eid hogae ha.
Vai ap jis machine se compressor ko chalaray oska name keya hay..plz
Ya seytem mil jyga ky bhi sb
Which compressor you used AC/ DC compressor
Inverter compressor are thre phses AC motors but in home are only one phase, so it rectify Ac and convert to DC that is applied to a PWM (Pulse Width Modulator) that not only are in 3 phases but can vay frequency from 53 Hz when motor has 1200 rpm to 130 Hz when goes to 3200 rpm.
I want you bye this circut . how purchase this. Plz help
Search for a "single phase variable frequency drive"
Bom dia , amigo queria sabe como faço pra comprar esse inversor inverter
How can I get a device like dat... I'm a HVAC tech
you can run a compressor like that with an arduino... im working to figure that out too... Im appliance technician and a hobbiest
Nice video
this compressor originally was one phase or 3 phase powered?
one phase compressor powered from 2 phase
thanks for reply, what about voltage? Do you think that any or most of home (one phase) fridge compressors can be powered from variable frequency drives?
witam, po naszemu będzie prościej. Co do napięcia do dokładnie nie pamiętam ale raczej było obniżone na falowniku bo to był IG5 na 400V. Raczej nie ma problemu z zasilaniem z falownika ale w rozsądnych granicach aby nie było problemu ze smarowaniem. Oczywiście mówimy o sprężarkach tradycyjnych a nie o iverterach. pozdr.
a jakiego rodzaju tam jest silnik? bo widywałem przy lodówkach różne patenty do rozruchu, silnik ewidentnie bezszczotkowy, a w takich przy jednej fazie są zawsze kłopoty ze startem. Pytam między innymi dlatego że miałem dobrać UPS do lodówki i przez prąd startu trzeba było znacznie większej mocy ups'a. Próbowałem ją puścić przez regulator na triaku, ale nie miała siły wystartować i ten motyw z falownikiem mnie zaciekawił, a znów nigdy nie trenowałem innych silników z falownikiem niż pracujące w trójkącie z szeregowym kondensatorem, czyli asynchronicznych trójfazowych.
silnik jest bezszczotkowy, układy rozruchowe raczej robią to samo , jest tam kondensator rozruchowy i zabezpieczenie sprężarki. tu na falowniku ładnie rusza prawie od 0 Hz ale sprężarka jest nieobciążona. Jak pracuje w normalnych warunkach to rozruch jest znacznie cięższy. Często przed wyrównaniem ciśnień wcale nie ruszy. Co do startu z przetwornic i zasilaczy z doświadczenia wiem że chinole się palą albo nie są wstanie ruszyć maleńkiej sprężareczki i trzeba sporo przewymiarować zasilacz
is it the invertor technology that is coming now a days in compressors... or u r trying to convey something else from this video 😞? ?
what is compressor inverter? is it the device used in some AC?
hi man.how do you run single phase motor by drive?
I connect the compressor to the first and second phase inverter, the LG inverter has a current transformer on these phases
@@elektro-kk4ns thank you man
Что он показал? Преобразователь частоты , который используют для регулировки скорости асинхронных двигателей! Изобретение прошлого века...
Can u pls give me the connection details.... Inverter Output phase to Compressor input phase details
Great informative video sir 👍 👍 👍 great work sir 👍 👍 👍 best regards for the future videos 👍 👍 👍
اذا أتينا بمتحكم السرعه لماتور مكنسة الكهرباء واستعملناه لتشغيل هذا الماتور هل يشتغل ؟
???
Yes it will work نعم
What does this do? What's the point of this? Shallom you are loved
Compressor work with Ac current and variable frequency for speed control . Am I correct .
yes
No 3phese division inverter MOSFETs
What is the relationship between the speed of rotation and current?
Hello Sar muje coupresan ka 35mm ka deta chahiye
ciao dove posso comprare il controller inverter?
Pone una pinza amperometrica para visualizar el consumo a diferentes revoluciones por minuto
Donde compro ese variador de frecuencia?
what is inverter company? Single phase?
lg ig5a 3 phase
@@elektro-kk4ns thanks .
A question compressor power input Ac or DC .??
AC compressor
so nice
Ye invaiter Kit kase milega
Name of this device sir and how i can get this
Lg ig5a
Vfd
@@elektro-kk4ns how can I get it?
You compressor 3phase dc compressor sir
very interesting
سلام .
موتور یخچال مورد ازمایش اینورتر سه فاز میباشد .
دستگاه که ان را تست میکنید درایور اینورتر برق صنعتی از تک فاز به سه فاز میباشد که بالا و پایین کردن فرکانس دور موتور تغییر میکند
Hi, i would like to know how did you connect this single phase compressor to this VFD? I need it for my degree's proyect.
Splits ac compressor
Sir and company name machine
Inverter compressor R V W
how to use an AC 1 phase compressor to VFD
Very usefull
vai ye kaha mile gi
what are you exactly doing?
sir sild kaperasr ripr kape hot h
Excelente 🇩🇴🇩🇴🇩🇴🌎
super vidéo !!! ou avez acheté votre variateur de fréquences ?
Fantastic.
Hello my Ac compressor is running but why starting 5 minutes after then is compressor sound coming and not cool only hit coming but compressor is also running and hit coming why
Maybe your system is low on refrigerant and needs a charge .
The a/c is working with few pcb. And everything is being controlled by them. After u run the system all sensors are sending signals to control board and then compressor will starts and if it’s inverter will start from low speed, depend on demand will speed up
Whats the name of this inverter.
lg ig5a XXXXI I don't remember exactly
sinus m inverter i believe 2fase controlled
Plz show the connections
Is this dc voltage or ac
ac
formidable
amazing
Nise
Cool!!!
Nevera sansung me congela el refrigerador
BEMF?
Hello, how did you make the device itself?