SGP413 Modified Differential Protection of Alternators
ฝัง
- เผยแพร่เมื่อ 17 ต.ค. 2024
- Lectures on Switchgear & Protection By Dr. Tirupathiraju Kanumuri, Assistant Professor, NIT Delhi
Link for Material
drive.google.c...
Lectures on Power Systems: • POWER SYSTEM
Lectures on EMFT: • Electro Magnetic Field...
Lectures on Synchronous Machines:
• Synchronous Machines
Lectures on Special Electrical Machines: • Special Electrical Mac...
Lectures on Transformers: • Transformers
Lectures on DC Machines: • DC Machines
Lectures on Induction Motors:
• Induction Motors
Lectures on Basic Electrical engineering:
• Basic Electrical Engin...
*Sir if ct characteristics are different then difference in current between two secondaries of two CTS will flow through the earth fault relay as *it is 20% setting is the relay operates.
*If operates what is the use of earth fault realy please reply sir.
I think that's why we use balancing resistor.....For limit spill current
For R phase to ground fault, only earth fault relay will operate, so which CB will operate? Only of R phase or any other? @ 9.00 minutes
Sir ,are positive and negative sequence current both responsible for operating of phase fault relay or only positive sequence is necessary for operation??
sir please, I didn't really get the explanation you gave for the reason why the earth fault is made to protect up to 85% of the winding...can you please explain that?
Very good 🙏🙏🙏🙏. Thanks 🙏🙏🙏
Sir but there is no much upgradation in protection na from normal differential protection ? Why that BR is introduced i didnt get properly ? Ill join your video chat session on 28-03-2021
please explain me
Sir , could you please explain what happens when LLL and LLG fault occurs.
Sir i didn't get how it overcome the limitation of expternal through fault against normal differtial scheme??
Sir, please do lectures on power systems stability as early as possible. Thank you sir
I have a doubt. Sir why only positive & negative sequence currents flows in line to line fault??
Sir.. Which kind of faults occurs for 3.5 kva rating in 3 phase alternator
what is the function of balancing resistor in that?
Sir, could you make a video on Neutral Isolating Contactor or Neutral Contactor????
thank you great lecture let me subscribe you!
If phase to ground fault occurs in second phase. Then what will happened sir. Because there is no operating coil in the second phase.
Thank you very much Raju sir
Sir what is mal operate
very nice.
Thank u sir
Conclusion from 11:37