DIY Temporary Electrical Service Installation

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 มี.ค. 2019
  • DIY Temporary Electrical Service Installation
    I will be installing the wire and the temp power pole to provide
    power to the construction site during the build of a single-family house. We are going to be pulling wire threw a conduit that was installed threw and easement. I will also be installing the caution tape in the trench before I back fill. We will get the temp power pole installed in its location and make sure that it is ready for L@I inspection.
    Underground power started more than 50 years ago to replace overhead distribution systems. Underground service installations by the power industry is complex. However, it can be done and has a lot of great benefits. Lack of interest on the part of the power company should not deter you from taking advantage of the benefits of buried distribution systems.
    When the estimated cost of buried services exceeds the estimated cost of aerial services by more than ten per cent, you should negotiate with the power district or developer on the following basis:
    No charge where the developer, builder or, or you dig and back fills trenches for the distribution cable and all service wires.
    where you digs and back fill all trenches, the developer or builder will pay that cost which exceeds the estimated cost of aerial plant by more than ten percent.
    I recommend that underground power systems be used exclusively. There are certain instances where it is not feasible however theses are very rare.
  • แนวปฏิบัติและการใช้ชีวิต

ความคิดเห็น • 60

  • @kneewall49
    @kneewall49 5 ปีที่แล้ว +2

    thanks Dan for going to this great trouble to show or rather share your knowledge on this particular aspect of building a house. Even though I live in Australia the basics are the same. Very valuable info for when I do this myself soon. Thanks again for you dedication to share your knowledge.

  • @pinchemahalosupin3310
    @pinchemahalosupin3310 4 ปีที่แล้ว +4

    I "dig" your channel and your vids are super informative, I am getting ready to bring new electrical service to my house and these vids will help me throughout the process.

  • @RSDX99
    @RSDX99 5 ปีที่แล้ว +1

    Glad to see you did the service conductor installation in the proper order. First you run the conduit, then you install the pull wire by either blowing or vacuuming in and then you pull in the conductors. Another very good u tuber showed an improper installation of laying the conductors in the trench and then sliding the conduit over then wires. I wish somebody showed him the correct method. Good job here.

    • @MukYJ
      @MukYJ 5 ปีที่แล้ว +1

      I cringed a little when I saw Andrew doing that...

  • @barrb6134
    @barrb6134 5 ปีที่แล้ว +4

    Thanks for taking the time for all the explanations, nice video. The only thing I would have suggested to make this job easier, would have been to use a roto-hammer w/attachment for grounding rods. Makes it soo easy.

  • @OutdoorswithErik
    @OutdoorswithErik 5 ปีที่แล้ว

    Love the hammer effect and sound. Man, I want a backhoe LOL

  • @mikeward2890
    @mikeward2890 5 ปีที่แล้ว +1

    Thanks for the information. This helps a lot.

  • @pauldow1648
    @pauldow1648 ปีที่แล้ว

    Helpful overview of process. Thanks.

  • @georgechadis4713
    @georgechadis4713 2 ปีที่แล้ว +1

    Thanks, very informative!

  • @doodledragon2605
    @doodledragon2605 ปีที่แล้ว

    Thanks for sharing your experience.

  • @tonysreviews
    @tonysreviews 5 ปีที่แล้ว +3

    For real. I have realized before I do any work I contact the local government to find out the rules and who does what. Nice work.

  • @____________________________.x
    @____________________________.x 5 ปีที่แล้ว +2

    Put ribbon in trench, then take it out again so you can backfill it correctly. Gotta love those Jobsworth Inspectors...

  • @terencerucker3244
    @terencerucker3244 4 ปีที่แล้ว

    My first video on this subject and the first one to come up on TH-cam. As I'm watching, I'm thinking "well, this will be a good intro but I will have to go to my county to get the details" And guess what? I live in Kitsap County Washington. Ka-ching. Too make it even better, my daughter lives about a mile from this jobsite! Thanks for the good video, and LOL, I will be using a BX-25 as well!

  • @juliolux74
    @juliolux74 ปีที่แล้ว

    Tus videos me ayuda un chingo

  • @eternalbeing3339
    @eternalbeing3339 3 ปีที่แล้ว

    Very helpful. I am in thurston and i think i am going to copy your setup.

  • @R7Romeo
    @R7Romeo 3 ปีที่แล้ว

    Thank you very good video

  • @danielmeyer403
    @danielmeyer403 4 ปีที่แล้ว +2

    Nice work. I'm an electrician and most homeowners would not tackle a project of this magnitude. Only observations are that it's actually URD wire not triplex. Triplex is for overhead wiring and the sizes of the conductors are 4/0-4/0-2/0.

  • @donnierobertson3088
    @donnierobertson3088 5 ปีที่แล้ว +1

    Good job

  • @jjustj
    @jjustj 3 ปีที่แล้ว

    nice other than scare tqpe should be 1/2 way down between surface and wire, so you hit it before hitting wire when digging!

  • @seanf7810
    @seanf7810 3 ปีที่แล้ว

    Remember pre-covid when you could actually purchase the parts you needed? Good times...

  • @juliolux74
    @juliolux74 ปีที่แล้ว

    Echale ganas compa

  • @Petertutinski
    @Petertutinski 5 ปีที่แล้ว

    Hi Dan, I discovered your channel a week ago and have been watching many of your videos. We have a lot in common: construction-y do all guy, Kubota tractor, western Washington. One wife, one daughter. My company’s office is in Kitsap County. I just need to start making videos and I suspect we will have parallel lives.

    • @DanielWoodell
      @DanielWoodell  5 ปีที่แล้ว

      It always great to here from likeminded people, I have lived in Kitsap Count my whole life it’s a great place. Your office is
      in Kitsap County what is it you do? When I’m not making TH-cam or spending time with the family I work at the Ship Yard.

    • @Petertutinski
      @Petertutinski 5 ปีที่แล้ว

      Daniel Woodell Right on. I work for a marine construction company out of Bainbridge Island. We build bridges and docks. We also do mass excavation and dredging. Im a welder/operator/carpenter/whatever-er. Keep up the good video work.

  • @rawfuelfoods1814
    @rawfuelfoods1814 5 ปีที่แล้ว

    good & timely vid, I live in Kitsap County do/will you advise off line

  • @electricalron
    @electricalron 4 ปีที่แล้ว

    M18 SDS Max for them ground rods.

  • @marcos22571
    @marcos22571 4 ปีที่แล้ว

    How far can I run the wire from the meter box before I need a transformer?

  • @FlyingAceAV8B
    @FlyingAceAV8B 2 ปีที่แล้ว

    How long was the run from the meter to the building?

  • @cjm9317
    @cjm9317 4 ปีที่แล้ว

    My state requires all burried wire be im conduit. How would i go about coiling as you did to go to the house

  • @tonylupo5230
    @tonylupo5230 2 ปีที่แล้ว

    There is no main disconnect in that meter base so the neutral termination supplies your bond to that meter cabinet. No need for another wire to bind the meter cabinet.
    This is Since I’m assuming your grounding electrode conductor is terminated in the main breaker panel with the neutral. And we are to Bond the neutrals and grounds at the first means of disconnect.
    Right ??

  • @juliolux74
    @juliolux74 ปีที่แล้ว

    Bunch of swapping and adding
    Just fallow the rules my friend but some times piss me off
    But is part of the show 🏃

  • @Dan-oz4qb
    @Dan-oz4qb 5 ปีที่แล้ว +2

    Put the ribbon in, take the ribbon out, put the ribbon back in. That sounds like a typical government operation. Seems like having a sufficient length on hand would suffice for the inspection.

    • @erictold
      @erictold 5 ปีที่แล้ว

      Inspector might not like it because you could save it for other job sites if it’s on your hand.

    • @Dan-oz4qb
      @Dan-oz4qb 5 ปีที่แล้ว +1

      @@erictold of course you could do that. You could also pull it back out as soon as the inspector leaves. Dishonest people will always find a way.

  • @jakehill322
    @jakehill322 5 ปีที่แล้ว +2

    Next time driving ground rods pour a bottle of water down the hole after it is started and then drive it for hydraulic effect

  • @wjthehomebuilder
    @wjthehomebuilder 5 ปีที่แล้ว

    Sounds like that dog is still around!

    • @DanielWoodell
      @DanielWoodell  5 ปีที่แล้ว

      Yup he is still driving me nuts!!!!

  • @ernestosalazar4590
    @ernestosalazar4590 2 ปีที่แล้ว

    Whats the difference from a permanent and temporary power box . I an conecting a mobile home and shed and dont know witch one i need ?

  • @duranbuildersllc554
    @duranbuildersllc554 5 ปีที่แล้ว

    Is this house gonna be for yourself? What do you do for a living? Thanks. Really enjoy the videos

    • @DanielWoodell
      @DanielWoodell  5 ปีที่แล้ว

      I was a pipe fitter for 15 years I have recently moved on to management, and it has given me more time for projects like this

    • @duranbuildersllc554
      @duranbuildersllc554 5 ปีที่แล้ว

      Oh awesome. Thanks for the reply.

  • @michaelvrbanac6923
    @michaelvrbanac6923 ปีที่แล้ว

    Backfilled after PSE inspection?
    PSE Handbook:
    "PSE shall assign a Project Manager to oversee the trench location, equipment placement/installation, and backfilling.
    • Work shall be subject to the inspection and satisfaction of PSE.
    • No work shall be backfilled, covered, or concealed until it has been inspected and approved by the inspector."

  • @caseyespeseth4306
    @caseyespeseth4306 5 ปีที่แล้ว

    I don’t understand the coil of wire buried below the temporary service. Why not just be able to go right into the temp service ?
    Is the extra coil for future potentially?

    • @DanielWoodell
      @DanielWoodell  5 ปีที่แล้ว

      Casey Espeseth The extra wire used to spool out to connect to the house once the house is built the temperate power pole is only there so that we can build the house.

    • @caseyespeseth4306
      @caseyespeseth4306 5 ปีที่แล้ว

      Very nice I’m three years in my apprenticeship to become a journeyman electrician and still seeing new and different stuff ever day
      happen to find your channel of repairing your flat bed trailer as I was looking for ideas for my flatbed trailer couple months back and like watching your work And also live in pierce county keep up the videos thanks for the good content

  • @KevinCoop1
    @KevinCoop1 5 ปีที่แล้ว +2

    I believe you stated the conductor sizes incorrectly. You said, 2 o, 2 o, 4 o. Pronounced Oh. I think you meant to say 4/0, 4/0, 2,0. Pronounced Aut, like the first part of Autumn. Sorry you hit the waterline but good job!

  • @12vLife
    @12vLife 2 ปีที่แล้ว

    Anybody familiar with Florida Laws on Temporary Power poles? I have a vacant residential lot on in central Florida on a very narrow and soft road few cars would dare drive through. No houses in 1000' square feet. However, 200' away there is a power pole. I am yet to have a survey done, have been able to drive to the middle of the lot where I've camp. I'm looking for the cheapest way to get Duke Power to run me a temporary 100amp power connection. I called they said the county would need to inspect and I would need a building permit. I've heard you can get a permit for just a well pump. How about if I want to manually clear myself using electric? Also, soon I will be driving electric and need power to charge my truck.

  • @robsdeviceunknown
    @robsdeviceunknown 5 ปีที่แล้ว +1

    crap. I didn't use that schmoo on my aluminum service cable I ran last summer. Oh well.

    • @joshbarron4415
      @joshbarron4415 5 ปีที่แล้ว +3

      Rob Lambert you absolutely need that. When it’s it’s used the aluminum expands and contracts which can lead to it arcing and a fire

    • @Mike_Muffler
      @Mike_Muffler 3 ปีที่แล้ว

      You'll be ok. Just make sure you have insurance.

  • @juliolux74
    @juliolux74 ปีที่แล้ว

    Yo ago lo MISMO

  • @gcg9056
    @gcg9056 3 ปีที่แล้ว

    did you see bigfoot?

  • @jakehill322
    @jakehill322 5 ปีที่แล้ว

    Sound effect on high speed sounds like a bunch of birds and mice

  • @marcos22571
    @marcos22571 4 ปีที่แล้ว

    How far can I run the wire from the meter box before I need a padmounted transformer?

    • @DanielWoodell
      @DanielWoodell  4 ปีที่แล้ว

      that depends on your local power companies engineering evaluation.