Welcome of All viewer, In this video we can see you that how to control,"Automatic Generator Change Supply Circuit With Practical in Urdu" and how to auto stop generator when wapda power supply ON.
Use Electical equipment for this circuit
1.Magnetic Contactor 2.Timer 3.Relay Switch
auto genrator maintenance
Magnetic contactor use for Auto change home supply from wapda and generator,
Timer Use for delay time to relay supply ON and generator stoped,
Relay use for generator stop when wapda supply ON,
You can play and watch Full practical video for full learning.
Circuits...drive.google.c...
Website. motorcircuits.b...
Facebook Page: / motorcircuits
Click to Subscribe
nice bahi aap ka practical batanay ka tarika bahut zabarzast hay bahut achi tara samj aa jata hay
tanx u ap ka bro bhot he achay as jasay batatay hoo ayk baar me samaj a jata ha tanx u bro
better than other TH-cam videos
Mashaa Allah. very nice and very educational. May Allah app ko Sadha slaamet rakhay Ameen
Mashallah sir aap bohat he atcha sikhaty hain aur bohat he atcha kaam kr rahy hai ...
Mari dua ha k Allah Paak aap ko khoah rakhy ...
MashaAllah sir bhot achche se samjhaya aap ne - Shukria
Motor Circuits
Bohat bohat shukria bhai etni behtreen informative or practical video banane ka...
thumbs-up
Very nice and easy tutorial....keep doing good stuff....Jazak Allah
or ap bahot zabardast tareeqe se samjate hain....
very nice
Thank you sir.
You are doing well.i am impress your work and knowledge.your work is amazing.you should keep it up
Wow nice diagram! Please Do us for Large DG start-stop by it self diagram.thank you keep it up
Kiya shandar video upload ki hae bhai. Great work. Bahoth maloomathi video upload ki hae.
The Engineer bhai is me timer nhi lagy to phr bi kam ho skta ha k nahi
The Engineer
shukar hay ALLAH ka aap sunaien yar bahi aap ke ye video achi hay magar iss mein 2 point miss hay 1 point ye hay kay generator off tu ho Jay ga magar sulf ko off karnay kay leye per pe utna pray ga dosra point ye hay kay gas ka value band karnay kay leye be utna pray ga iss leye mera kehna ye hay kay iss ki jaga ATS system best ho ga
Nice video...thanx for such a good video ...
w alaikum assalam Bahut Achchha sir
thank you for your advice
Great Job. Kindly share Over/Under/Surge protection circuit for domestic use (Single Phase). It will be very helpful. Thanks
No surg in low watt generator
Very nice video auto ganreter start pe video banaye plese
MashaAllah zabardast videos h bhai in sab chizo ki Pakistani price bata sakte hn ap
بارك الله فيك......i wait your new
باارك الله فيك excellent. ......
sir very nice and informative video , please generator k automatic on karnay aor crank delay ko set karnay wala circuit bhi shmjha dain.
sure sir , and advance thank
Emergency generator automatic start stop control circuit th-cam.com/video/qAxdDz_kcRw/w-d-xo.html
good appreciated
Thank you sir
Good for tiny project but don't risk it with home as more security features are required, generator with auto start and auto shut off surely required.
Aow ok
very good
Mashallah
Mashalla
Diesel generators ke mamle mai aisa ho payega Kya??
thanks sir nice video
Assalam walaikum
BHAI EK VIDEO GENERATOR AUR ATS PANEL WIRING PER BANAO ATS KYA KAM KARTA HAI AUR KIS TARAH KAM KARTA HAI ATS PANEL KA PURA DETAILS DE
v nice
generator ko auto start krnay ka tareeka batain
Vai genetor auto startwali video v banaiye pls
sir ek esi video bnaen jis main genretor power supply jany py khud on ho or power aany py khud of ho esi daygraam btaen plz
Salam Brother ?
sir kindly ye btao k agr wapda ki supply 10 ganty tk off na ho tu magnet contector ot timer ki coil ko lagatar 220volt miltay rahy gay tu kia coil garm ho k jal nai jaye gi plz ye bta dain????
Bhai auto start b upload krain
Salamoalikum
Bhai please auto start stop generator 3500 watt bna k dekhain
super lekn sir generator to off hoga gas to on rh gi wo to bnd karni he wo kese automatic bnd kare ge
Bhai aapne kha wapda aane par generator band ho jayega yaar generator ka load hee toh wapda pe transfer hoga bus generator toh disel se chalta rahega jesa aapne kha ki wapda jane pr generator Ko chalu karo or raat me so jate hai or wapda aane pr load hee toh transfer hoga generator se generator thodi na band hoga or Usme hme diesel ka losses hoga
auto start per video banain
nc bro
Me itni dair se video dek raha ta k ap ye sab generetor atumatic on hony k liye kar rahe ho with out key self start.is k jaga ap dpdt 220v 120amp wala relay lago with out contecter,without timer relay or o generator wala rely is k kea zarorat ti.ye sab kuch ap ek relay ko use kar k kar sakty ho.me ne gar par kea he bs 1 relay lagae he.
Acha bahi mein nay aap 2 contactor ka circuit bana lyea hay ab iss ki pic aap ko send karna chahta hon mein nay example iss mein jo contactor aur relay isstamal ki hay wu load kay mutabiq nahe hay mera generator 7.5 kva hay merry andazay kay mutabiq iss kay leye 65 amp ka breaker aur 65 amp ka contactor use ho ga aur jahan per loop laga hay kia udar hum overload relay laga saktay hein wesay tu dono contactor mein interlocking hay leken per bi agar dono contactor sath mein operate ho gay tu udar overload kam karay ga aap ki kia ray hay please help me
nice video
sir three phase wiring kis trha hoti ha ghar ma kysy ak ghar k andar three phase distribute kren gy plz is ki ak video banaye plz
Three phase system may ghar kay andar 3 phases and 1 nutral atha hae. Tho janab theeno phases ko kamro may hisab say distribute kar diya jatha hae. aur har kamray ko aik phase aur aik nutral MCB say control karkay day diya hatha jatha hae.
The Engineer bhai agr is timer nhi lgty drekt raley ko pawar lgaye to thek nhi ha
Aleem Sattar
face book ya number Btao
bhi Kindly Muje Batay ke Ye jo jo Cheez ap Ne Use ki he is ke Volts and Amp kitne he magnetic Contactor Timer or rely ka Volt's and Amp kitne he?
nice
bro please upload how to auto start a generator
thanks bro
please share with me link
220 ki relay per 24 v kisay lagay ga
sir kripya auto start ka bhi video banaye
Hñ ŕyyy nj
agar app in chezo ki price batate tu acha hota
kia mein ek magatic starter ki jaga 2 magatic contactor use kar sakta hon
ATS penal ki waring ka bta dn
bhai is me timr nhi ho phr bi kam ho skta ha k nhi
Shifting k leya timer k zareya delay karvana cahya ta k koi chez jaly na
ustad ye 1contactor pe kese hogi shift line kya ye alag contactor hai plz rply nd kya kehty hn is ko
like
Sir is it not better to use one coil, by using AC main at Coil point of and joint ignition coil cable at point 8 and 5
Please tell me about stander code which in use to star delta connection with video practical thanks
Sir main.telenor
mera generator 7.5 kw out put ka hay aur sulf start hay box me sulf ki chabi ko jo wiring aae hay wo 12v hay tu relay 220 ki kahan lagaen gay
thamil explain
subamsibal sratar ki wiring batavo
OK
mary pass 2 wapda ki line he mein chat ho ke ek line off ho tu lod dosri line par shift hojay serf ek 2 saver he is kaly relay 10-15 amp ki chey hogi sayad Is ke price kiya hogy and ap sell krte he ye?
salaam sir..is vidio may jo 2 wire relay may generater say lagty hy.chabe waly generater me hm phase ki pehchan kaisay kary gai.odher wire tory ziada hoty hy.
agar app timer ki baghair karte tu bhi hojatah hain
bhi Jo apne Genrator ke sath lagaya he ne white sa uper se lag se wo he Transparent color wala
Abhey Raja me video dehk raha tha awaz se me tujey hi mehsoos kar raha tha neche dehka tera massage wawaa
Sheheryar Ali haha Bhi Dekho Muhabat
Sheheryar Ali bhi ye seting mane krli he ap ko krwani ho tu batana ap ko samjdoga
Han Bahi mene karna he per ye bataoo jo relly he wo konsi h naam kiya he uska or connection thore samjh nahi ah rahe
Or relly kitna load uthayegi andaza
Normal ghar jahan ye chiezen hen kitne ka magnetic contactor chahiye.
Ek fridge
4 fan
4 tube light
Ek washing machine
Ek iron
Kuch mobile and laptop chrarger
Sir mere pass 3ph ka Ganretur he 63kg ka to usko automatically chalu Ho Jaye power Jane ke bad muje iski wiring ka diagram batane or usme Kya Kya lagane ha pls diagram se hame samjaiye
Istrah to Contactor ki coil hamesha energize rehay gi jab WAPDA lene hogi
How? Wapda supply contactor NO se lere ho aap
bhai maray pass 30 amp ka magnetic contactor 4 open 4 closed
can I use for 6 KW generator. and k electeic. my load is 2 inverters ac 2 fridge
my queation is that what is neutral contact size in 3 phase because neutral also pass feom contactor other wise kelectric meter show light
Thanks
sir ye to tek hai thanks but ak problam hai sir ap ne jo brakar se 3 paz nekale hai wo samaj mai nahe ate hamai
bhi ap mane 220v 10 amp ki rely leli he thek work kr rahi he 2 wapda lins par but kabi kabi buhat taaz vibration or awaz krne lagti he kiya waja hosakti he
sir is pe 3 face 380 se light kese deni ha....
or sir jo puch buton hota ha no nc to sit us ki mujhe wirng ki samaj ni aai ha....
Bhi ignation coil se garneter band kase hora hain
plc me lubrication oil connection
السلام عليكم Well but What about the auto star of generator. ......
circuit diagram upload pls
Sir Ya Load Reng kya hai...
Mugko 6 Ac Or Moter Pump 2
Or Baqi Home Load Auto Generater pur Krna hai....
K jub light Ai To Auto Generater Off or Supply Connect ho Jay. ...
Ans Replay
ye kon sa magnetic contactor hain jo is video main apne btaya hai amin dukhan se darse kya bolo jo ye wala magnetic contactor dy dy. ???
sir y khod start bhi hota h
بھائی جو رلے لگاہے ac ہے یا dc ہے
N
ap kaha rehte han
sir appne automatically phase changover ke deyagrom batasakte hair kay
sir g automatic water pump
and sir imo skype wagera agar ha to please de dein take aap se mukamal maloomat le sakoon....
sir g itna kuch lagane ki kia zarorat thi ye sb tu 2 magnetic contactor se bhi ho jata
Telugu class
Bahi 2 Metr or 1 generator ko auto on and off kesy karny
@@motorcircuits9538 Jab AK Metr ki light jy to dusry Metr ki light on ho jy dono side pr or jb dusry ki light off ho to generate pr chalny or jab AK ki light a jy to generate off ho jy or dono side chalny lagny or jb dono Metron ki light ho to elyda elyda chalny
@@motorcircuits9538 ye circuit bna kr dny plz
Sir timer se delay kiun jarur hai ? pleas
bahi sehib ye bato genrator dubara kesey on ho ga ye tu automatic on off nahi howa........
Wanda anepar generator late off hota hai timer se to Wanda ka aur generator ka phase to phase short Q nahi huwa
sir wapda off honay pr generator auto ksay start hoga mere pas self genset hai
Us kay leye thora mazeed circuit aur voltage comparison circuit lagana parhtha hae.
sir es timer ki keemat kya h
Sir timer se rily mi 10 second ke liye hi saply ja raha hai our o ignecian ko jane wali sapply kat ho ja rahi our ganreter of ho ja raha hai please ripley yes ya no me ans dijiye please
bhai mja ye daigram ki pics yhan send kr dain
mja ksi ko send krni hain