Indoor Propane Plumbing - WE HAVE GAS. (and leaks)

แชร์
ฝัง
  • เผยแพร่เมื่อ 19 ม.ค. 2025

ความคิดเห็น • 36

  • @sodiumvapor13
    @sodiumvapor13 5 วันที่ผ่านมา

    props for showing the fails as well! subbed.

  • @kevinhornbuckle
    @kevinhornbuckle ปีที่แล้ว +6

    When you use blocks as a pad outside, you can fill the cores with gravel (almost full) and then use thinset to adhere a piece of tile backer. Kind of the the poor man's slab. This will also give you the opportunity to mix a small batch of thinset and call it practice for when you go to tile your bathroom or kitchen backsplash.

  • @andrewshakespeare4978
    @andrewshakespeare4978 ปีที่แล้ว

    Nice work! Happy Sunday!

  • @chrisalister2297
    @chrisalister2297 17 วันที่ผ่านมา

    @7:40 those gauges can also leak. Also put a reliable cutoff valve in front of the gauge.

  • @KnowEverythingAboutNothing
    @KnowEverythingAboutNothing ปีที่แล้ว +1

    I know the TWH has it's own shutoff but I'd put one before the flex connector as well. Will be able to isolate that system in case the hose leaks without having to shut off everything else. Neat that the TWH has it's own dirt trap but kind of pointless since you added one at the main manifold which is at a lower location.
    I generally just pipe dope, I do find the t-tape makes removing fittings a lot easier down the road. Don't trust the Schrader valves and test rigs, they tend to fail lol. I do 30 PSI for 3Hrs for pressure test, this makes finding leaks easier too when using soap test.
    The foam/small bubbles don't matter, just want to look for bubbles forming or getting bigger.

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว

      Thanks for the input! Yes half the time it's my test rig that leaks so that's always the first thing I check 😁

  • @89Ayten
    @89Ayten ปีที่แล้ว +3

    It looks cold. Don't spray paint in the cold if you can avoid it. Meaning paint those pipes in a warmer place first, then touch up after. If you absolutely must, then warm up the can in a pot of hot water first.

    • @laurieclarkson9180
      @laurieclarkson9180 11 หลายเดือนก่อน

      So true! Weather has a huge affect on spray paint. If it's below 65-70 degrees it gets sticky and doesn't coat well, even colder it freezes. If it's humid or raining it takes hours to dry while on a hot day it'll almost dry instantly.

  • @raulromero6462
    @raulromero6462 3 หลายเดือนก่อน

    You rock brother 🤟

  • @frankieboy2417
    @frankieboy2417 ปีที่แล้ว

    I like that hole bit, over the years I spent way too much time removing wood plugs. What make and model of the bit.

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว +1

      They're a total gamechanger, I will never use the old style again. Here's the link: urlgeni.us/amzn/aupg

    • @frankieboy2417
      @frankieboy2417 ปีที่แล้ว

      @@MasonDixonAcres Thank You

    • @frankieboy2417
      @frankieboy2417 ปีที่แล้ว

      @@MasonDixonAcres Just in time, when I set up my coop I want juice coming to it. Can't wait to send you guys pics of the finished product.

  • @adamjerozolim9380
    @adamjerozolim9380 26 วันที่ผ่านมา +2

    Your problem is those baby wrenches. You are going to have leaks all over that house. I knew the leak was in that manifold the second I saw your wrenches. Get yourself two >14" pipe wrenches and you won't have a leaky joint again. Remember, "Everything is tight till you get a bigger wrench"

    • @MasonDixonAcres
      @MasonDixonAcres  23 วันที่ผ่านมา

      haha must have just missed the german torque spec on that one.. "gutentight"

  • @kmfenno9012
    @kmfenno9012 6 หลายเดือนก่อน

    Is that outside elbow cross threaded at 16:59 minutes??

    • @MasonDixonAcres
      @MasonDixonAcres  6 หลายเดือนก่อน

      Haha no it’s an illusion. You’re the second person to comment that actually

  • @totallybonkers
    @totallybonkers ปีที่แล้ว

    Looks like you cross threaded a part of the gas line - the 90 @ 16:54

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว

      See what you mean, but it was just the camera angle and how the foam was sitting! That was assembled by hand

  • @ChrisRadway
    @ChrisRadway ปีที่แล้ว

    looks like bit of stress on the compression fitting on short csst pipe soapy water test

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว

      the official leak test was by the gas company before the tank hookup, all is well and good

  • @kevinhornbuckle
    @kevinhornbuckle ปีที่แล้ว

    Are you a mechanical engineer?

  • @ChrisRadway
    @ChrisRadway ปีที่แล้ว

    Dont mess with gas.Youre scaring me

  • @DouglasPFresh
    @DouglasPFresh ปีที่แล้ว

    Maybe a newer pipe wrench with teeth.

  • @chrism4351
    @chrism4351 ปีที่แล้ว +1

    I'm all for DIY most of the time, but electrical and gas are two trades that should be left to licensed tradespeople. Consequences of mistakes are too high.

    • @MasonDixonAcres
      @MasonDixonAcres  ปีที่แล้ว +2

      We’re doing both so hopefully we read the code closely enough 😆

    • @neilaxelrod5872
      @neilaxelrod5872 9 หลายเดือนก่อน

      @@MasonDixonAcresit’s not about knowing the code. It’s about the experience. There’s a reason apprenticeships exist and are supervised by experienced journeymen.
      I get the “we built our own house” schtick, but putting lives in danger makes no sense. It’s why licensing and training is so extensive for trades.
      If anyone could just read a book, there’d be no need for licensed tradespeople.

    • @StrongLikeBullTV
      @StrongLikeBullTV 2 หลายเดือนก่อน +1

      Timid, subservient opinion. License. The government shouldn’t what I can can’t do to my home

    • @kevinlevesque2659
      @kevinlevesque2659 หลายเดือนก่อน

      No way you are going to run that water heater on that length of 3/4” csst. The little twin stage regulator at the tank is only good for 200kbtu. The w/h is 199kbtu . By the time the gas gets to it on your 60plus foot run, no possible way will you be able to maintain 11” wc. This is not including the under ground pipe length. It will be like sucking mud through a straw. The heater may run, but it’s going to soot up very quickly. You will probably get a low gas pressure alert when it starts up… Change the tank reg. to a 10psi first stage, and pipe in a 2nd stage on the riser coming up near the house. You may get by with that set up.

    • @MasonDixonAcres
      @MasonDixonAcres  หลายเดือนก่อน

      The csst goes to the stove. The water heater is right inside the house off the 1” line with a 3/4” x 24” appliance connector.

  • @reliableenergysolutionsmir6813
    @reliableenergysolutionsmir6813 หลายเดือนก่อน

    your gas technicians just screwed you by installing that piece of 5/8 copper. They just choked the entire piping system down and you just lost BTU capacity of you water heater. Funny the professionals are the ones not knowing what they are doing. lol.

    • @MasonDixonAcres
      @MasonDixonAcres  28 วันที่ผ่านมา

      haha yeah it's what they had on the truck of course. One day I'll probably go underground and change it. We probably only use 15% of the tankless capacity so haven't had any issues