Watch this before you buy a home standby generator. Four models tested to the limit.
We tested four new models. Generac, Briggs & Stratton, Cummins and Kohler.
Working in cooperation with several dealers to accomplish this.
HGS Generator, Critical Systems Generator Services
มุมมอง: 80 809

วีดีโอ

ความคิดเห็น

  • @ScottHartley-c3t
    @ScottHartley-c3t วันที่ผ่านมา

    Brought to you by A Dealer that only sells Kohler, surely it must be unbiased!

  • @sanleon1314
    @sanleon1314 6 วันที่ผ่านมา

    Great video! Just purchased a Kohler RCA20 from Power Equipment Direct, installing it this week myself in Houston area.

  • @Pandabubba9
    @Pandabubba9 26 วันที่ผ่านมา

    I’m a new person in Florida. I’ve lived in Connecticut. I saw this video and was so excited about all the brands being tested, and figured Pennsylvania would know their power outages.

  • @ThePete2432
    @ThePete2432 หลายเดือนก่อน

    Just ordered the kohler, thanks

  • @n-da-bunka2650
    @n-da-bunka2650 หลายเดือนก่อน

    Would love to get a copy of that report. I am located outside of Charlotte, North Carolina

  • @July.4.1776
    @July.4.1776 หลายเดือนก่อน

    The average homeowner should never approach anywhere near 100% load. You are completely undersized if you’re running any where near that.

  • @nickm764
    @nickm764 หลายเดือนก่อน

    lemme guess you guys are a Kohler authorized dealer....🙄

    • @thomasw4032
      @thomasw4032 หลายเดือนก่อน

      Did you read all of the comments? All four dealers were there. Not in everyone's best interest to post the same video. We wasted about 25k $ and our entire weekend to do this test. So you're welcome to make your own video.

  • @TheJmw116
    @TheJmw116 หลายเดือนก่อน

    Where's the rest of the video? You only show voltage on the charts.... You need to show HZ and THD with load applied.

  • @batemanjo9
    @batemanjo9 2 หลายเดือนก่อน

    Also Kohler has better fuel economy

  • @tonioyendis4464
    @tonioyendis4464 2 หลายเดือนก่อน

    It's Cummings for me! Generac just ain't what they used to be with their inferior quality-controls.

  • @aldavison420
    @aldavison420 2 หลายเดือนก่อน

    The 2 smaller generators should be more efficient than the 2 larger units. How is this a fair comparison?

  • @artguti1551
    @artguti1551 3 หลายเดือนก่อน

    I think this test should be done in Phoenix AZ during the middle of Summer. That's a true TEST!

    • @KB-ke3fi
      @KB-ke3fi 2 หลายเดือนก่อน

      Or a hurricane in Houston with power lines wrapped around 110 foot pine trees for 10 days....and cars too.

  • @Beamin-vt7jm
    @Beamin-vt7jm 3 หลายเดือนก่อน

    Briggs is garbage

  • @hellblast911
    @hellblast911 3 หลายเดือนก่อน

    Great job - y'all didn't happen to compare noise levels did you?

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      No, sorry. I do think the Cummins was the quietest. it has more sheet metal around it.

  • @TheDieselndust
    @TheDieselndust 3 หลายเดือนก่อน

    This message was brought to you by Kohler. 😂

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      There was a dealer for each brand.

    • @dj3114
      @dj3114 3 หลายเดือนก่อน

      You must have a Generac.

    • @wgyoungblood
      @wgyoungblood 3 หลายเดือนก่อน

      @@thomasw4032 but Ironically Critical Power Systems is a Kohler dealer lol.

    • @KB-ke3fi
      @KB-ke3fi 2 หลายเดือนก่อน

      @@thomasw4032 looked like a Kohler ad to me. I had 2 friends during the hurricane and their Kohlers blew up...the motors fried, and it took the maint co 6 weeks to fix it.

  • @haydenmontgomery9718
    @haydenmontgomery9718 3 หลายเดือนก่อน

    Do you think you can run 18000 watts from 5 air fryers 2 pizza ovens and a deep freezer constantly everyday with a Briggs and Stratton 24kw ?

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      possibly at 220v. The algorithm dropped voltage at half load.

  • @badlands555
    @badlands555 4 หลายเดือนก่อน

    I just had a 14KW Kohler installed. Hoping it will be a good unit. For me one of the items was the Kohler engine. I think they are good engines.

    • @carapungo
      @carapungo 4 หลายเดือนก่อน

      will this unit power up your AC unit?, is it a 4 ton?, is it loud?

  • @jaredengberg9295
    @jaredengberg9295 4 หลายเดือนก่อน

    So the 20kw Kohler was able to start a 5 ton ac unit while already under a load of 20 kw???

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      Yes. It ran for a little while before the software shut the system down, same as the cummins. Both had software protections.

  • @randybox2734
    @randybox2734 4 หลายเดือนก่อน

    Let's just use a Kohler that's 20% smaller, okay?

  • @p.bateman7033
    @p.bateman7033 5 หลายเดือนก่อน

    Comparisons on warranty, parts availability, etc. is important to include.

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      Excellent points. How close is the servicing dealer. Do they have 24hr support. All very good points. !

  • @xfirehurican
    @xfirehurican 5 หลายเดือนก่อน

    Done! Getting a Kohler. Tks!

  • @TexasNightRider
    @TexasNightRider 5 หลายเดือนก่อน

    Helpful Video. Thank You.

  • @warpedphreak
    @warpedphreak 6 หลายเดือนก่อน

    this is truly useless info and completely subjective BS. Welcome to "statistics" punks - I can make data points say what teh F ever I want too with ZERO reality or proof. NICE AD... nothing more. pathetic... leave to PA to pull this shit... near bad as FL in that crap

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      Did you buy 4 units and make a video? Please provide a link.

  • @jeffbeaman9386
    @jeffbeaman9386 6 หลายเดือนก่อน

    Great video guys! short concise, and it's clear you brought out the test equipment to make it more objective. Thanks for sharing!

  • @cmkpro81
    @cmkpro81 7 หลายเดือนก่อน

    The KW’s didn’t even match on but 2 of the machines…. This was a bullshit ass test. That B&S hands down is the best one yall got just on warranty alone. Not to mention that you don’t need the warranty cause it’s built like a 7.3 Power Stroke. Briggs all the way!!!!!

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      The test was to see if they could provide the output they claimed. It was not a VS. test. The data log shows how B&S dropped voltage to make up for lost hp.

  • @jser4822
    @jser4822 7 หลายเดือนก่อน

    Go Generac or go home!

  • @joecrocco5501
    @joecrocco5501 7 หลายเดือนก่อน

    I have a 27kw Generac. No one can figure out how to run my heat pump unit. Generac factory no help at all.

    • @chadshriver2952
      @chadshriver2952 6 หลายเดือนก่อน

      What do you mean?

    • @NoSpam1891
      @NoSpam1891 5 หลายเดือนก่อน

      Ask an HVAC guy about a soft start kit.

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      How much aux heat strips are there? in KW, amps or watts .

    • @joecrocco5501
      @joecrocco5501 3 หลายเดือนก่อน

      First, my bad. Unit is 22kw. Soft start was installed and now unit comes on but with switch back to utility power it comes on in heat mode and we have to shut off at thermostat. Not good if we are not home.

    • @joecrocco5501
      @joecrocco5501 3 หลายเดือนก่อน

      I am not an electrician. I had two generator contractors try to solve the problem with no luck or help from factory.

  • @johnstraley9057
    @johnstraley9057 8 หลายเดือนก่อน

    Good comparison of electrical performance. In the final analysis in choosing a brand, the remaining factors in play include reliability, the dealers quality level of service and availability of replacement parts.

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      Very well put!

  • @TheBurnsStuff
    @TheBurnsStuff 9 หลายเดือนก่อน

    Ahhh!! Just want I was looking for. I'm up in Moscow!

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      Hello! 30 mins from us.

  • @marshallbrooksjr.9088
    @marshallbrooksjr.9088 9 หลายเดือนก่อน

    While the test formats were well devised, it would have been nice to have a larger view for a longer period of time of the test results on your graphs. In addition, the type of fuel you were using in the tests should have been stated along with any derating factor accounted for. My 17 years experience with generators statistically proves Kohler is a superior product. My crew only installs Kohler, if customers prefer other brands after I explain the premium operating characteristics and reliability factor of Kohler gensets, I politely suggest they find another service provider. Reluctantly, I repair a generjunk on occasion to make payroll, their failure is a given.

  • @Silverfun11
    @Silverfun11 9 หลายเดือนก่อน

    Can you test Kohler’s new 26kw?

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      Yes. I don't know if I can get all of these dealers to bring these units in again. But I could do an individual test on a Kohler 26RCA

    • @Silverfun11
      @Silverfun11 5 หลายเดือนก่อน

      @@thomasw4032 yes just an individual test on the new one would be great!

  • @Ark-Angel44
    @Ark-Angel44 9 หลายเดือนก่อน

    Super light on detail. Hmmm.

  • @gibblespascack1418
    @gibblespascack1418 9 หลายเดือนก่อน

    Who needs 20-24 KW of power for backing up their home in an emergency? The average house uses 15 KW per day. Most can get by with 10 KW for most of their house needs. The only ones that need a huge generator are houses with a well pump, everything electric and a ground source heat pump and that is if there is no priority load start up circuits. But it is a good video.

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      We have many homes with 5 ton heat pumps. Each unit has 15kW of aux heat. Some houses require 60kw generators once an electric oven and water heater are added in.

    • @gibblespascack1418
      @gibblespascack1418 9 หลายเดือนก่อน

      I get it, full on back up power, so that no one is inconvenienced during a community emergency. It just seems odd to me. We are going to try to get by with 3600W because it is an emergency, right. However, for my mom, she has electric everything, we installed a 14 kw unit which keeps everything going for her. We are thinking of putting in a ground sourced heat pump for her farm house which will change things. 4 tons should be fine for the 1850 Farmhouse and we will probably need a power management switch to make it work.@@thomasw4032

    • @July.4.1776
      @July.4.1776 หลายเดือนก่อน

      I have never approached 50% of the load on our 17KW BRIGGS & STRATTON.. HAVE NEVER HAD ANY ISSUES. It’s not a good plan to run a system at 100% of load. I was in charge of keeping our 950KW generator maintained and operational at my last position we never ran a load over 45% on an engineered system. The only time it went higher was during our annual load bank test with a 50% load, then 75% load and 100% load while checking emissions.

    • @gibblespascack1418
      @gibblespascack1418 หลายเดือนก่อน

      @@July.4.1776 10Kw seems about right when you are running everything and the christmas lights. It is an emergency, not a permanent power for the future. Thank you for speaking up.

  • @machaf
    @machaf 10 หลายเดือนก่อน

    More like an Ad than a 'test'.

  • @stephenalbright6961
    @stephenalbright6961 10 หลายเดือนก่อน

    I knew the generac was junk

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      We don't like to call any of it junk. Some units are built to meet a specific price point. Its like comparing GM , Kia, Ford and Toyota.

  • @sickwhip
    @sickwhip 11 หลายเดือนก่อน

    Best video ever. 2 minutes. Didn't have to sit through 20 minutes of babble to get the information. Bravo.

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      Glad you enjoyed it!

  • @markavery2888
    @markavery2888 11 หลายเดือนก่อน

    Why are the scales different on the voltage and current charts? We also need to see the capture time used for the meters. It looks like they are set different.

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      The meter automatically adjust the range to use the least amount of space on the scale. The Briggs & Stratton unit when applied load you could see that the unit dropped voltage as a way of saving the horsepower. This is a way of seeing the algorithm on how the controller is set up.

  • @trith72
    @trith72 ปีที่แล้ว

    I don’t buy these results for a second. Your board shows that you had a full failure starting a 5 ton ac on the Generac with only a 10k load and I can 100% say either you starved the generator of fuel to make it fail, or you flat out lied, i have that generator on my house and a 5 ton AND 3 ton unit and my lights dont even flicker when the 5 ton kicks in, with the three ton and most other normal appliances running. Something isn’t adding up about your tests at all……

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      That may be because the power factor is different. We use 10 KW of straight resistance load. PF1 .

    • @July.4.1776
      @July.4.1776 หลายเดือนก่อน

      I think old Tom is a salesman. 🤣🤣🤣

  • @redredred1
    @redredred1 ปีที่แล้ว

    This is the video? This is like a summary - is there not a long video showing everything you did and how they performed?

  • @patiencezero-xc9zl
    @patiencezero-xc9zl ปีที่แล้ว

    Lol....what a load of bullshit......flips through data faster than shot through a goose. AND, you are a Kohler dealer

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      There are 4 dealers from each brand in the video. We will upload the full video soon.

  • @kirkstinson7316
    @kirkstinson7316 ปีที่แล้ว

    And the Kohler only cost a few hundred more than a Junckerac

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      We often ask, why Honda is not in the market for auto start home generators.

  • @blueboat9581
    @blueboat9581 ปีที่แล้ว

    Generac is the best

  • @allmysleepingcats1545
    @allmysleepingcats1545 ปีที่แล้ว

    OUR ADVICE: AVOID BUYING A CUMMINS GENERATOR. WE HAVE BEEN WAITING ON A STARTER FOR MONTHS NOW-- TERRIBLE SERVICE AND RELIABILITY. WE'VE HAD 3 POWER OUTAGES IN THE MEANTIME AND NOW WE'RE TOLD PART WON'T BE IN UNTIL MID SEPTEMBER. TERRIBLE CUSTOMER SUPPORT.

    • @kirkstinson7316
      @kirkstinson7316 ปีที่แล้ว

      Very true! Cummins warranty parts have been taking several months to be shipped for a couple years now. I used to always recommend Onan as the top dog generator but now it's Kohler

    • @thomasw4032
      @thomasw4032 3 หลายเดือนก่อน

      That's terrible, The Cummins did very well in the test. Maybe try another dealer?

    • @peyote777
      @peyote777 23 วันที่ผ่านมา

      Our Cummins 20KW did stellar during Hurrican Helene. . . ran straight for a week. But service is hard to find and the major dealers want $1200 just to service it. . . don't know how to adjust valves or clean slip rings. No videos for homeowners either. I hope I don't have any trouble with it. They do have a tsb for the fuel solenoid, but no instructions to put it on. I will end up doing the basic service on it, otherwise way too expensive. I still think the Cummins looks the best. . . .others look like above ground caskets in your yard! LOL

  • @XxsoonerbornxX
    @XxsoonerbornxX ปีที่แล้ว

    The kohler is way too expensive and they are hell to work with when it comes to warranty work. The generac is the best one ot buy bar none.

    • @kirkstinson7316
      @kirkstinson7316 ปีที่แล้ว

      As a field mechanic for 30 years, working on all brands, I'll tell you your statement is WAY off. The Kohler is only a few hundred more then Generac. And Kohler's have beat Generac in test after test.

    • @ChubbsyUbbsey
      @ChubbsyUbbsey 10 หลายเดือนก่อน

      Generac isn't even close to the best. Both Kohler and Cummins are far superior.

  • @ThomasMarcotte-jt9od
    @ThomasMarcotte-jt9od ปีที่แล้ว

    Great test. I'd like to see more coverage of this test. Thank you for doing it.

  • @frankb518
    @frankb518 ปีที่แล้ว

    I get doing the comparison, But the isn't the Size variety a little " UNTELLING ?" Just because A 26kw has A 4 cylinder car engine basically and A 20 KW Is A smaller engine, 2 cylinder. so, why not put the Briggs 25-26kw up against the other 26 ?

    • @kirkstinson7316
      @kirkstinson7316 ปีที่แล้ว

      Uhm. No. These are all air cooled units. All have a two cylinder engine

    • @frankb518
      @frankb518 ปีที่แล้ว

      Got it. Thanks for Clarifying!@@kirkstinson7316

  • @jacobalderman105
    @jacobalderman105 ปีที่แล้ว

    👍👍 straight to the point! Love it! Thank you!

  • @Hoosier_Life
    @Hoosier_Life ปีที่แล้ว

    Why didn’t you use a GENERAC 26kw for the test since they came out with that size first

    • @josephlacara1283
      @josephlacara1283 9 หลายเดือนก่อน

      Actually no. Briggs and Stratton came out with a 26 kw first and it took Generac over a year to catch up and it still makes less power.

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      This wasn't a maximum power test. It was only to see how they performed according to their data plate.

    • @wgyoungblood
      @wgyoungblood 3 หลายเดือนก่อน

      @@thomasw4032 You literally say in your video at the 15 second mark you got the largest air cooled generators offered........ 26kw Generac was out long before this video, and interestingly enough, the Generac 26kw design is different than the 20,22, and 24 kw units.

  • @solarandwindinsouthtexasda1473
    @solarandwindinsouthtexasda1473 ปีที่แล้ว

    I own a Generac. My Generac is 28 years old. Never miss a beat.

    • @MRSTEEL15
      @MRSTEEL15 ปีที่แล้ว

      Good to know... TY

    • @johnnyhotrod
      @johnnyhotrod ปีที่แล้ว

      That was before they got taken over by a large corporation and quality control suffered.Hold on to that bad boy

    • @kirkstinson7316
      @kirkstinson7316 ปีที่แล้ว

      ​@@johnnyhotrod You mean back when they were vertical shaft, belt driven units? With circuit breakers that were a few amps higher than the generator was rated at?

    • @thomasw4032
      @thomasw4032 9 หลายเดือนก่อน

      ​@@johnnyhotrodexactly.

  • @davegerrard6857
    @davegerrard6857 ปีที่แล้ว

    Ive had several experiences Kolher engine and id never trust one for a backup system of any kind! Shitty in my experiences! I can't even imagine counting on one for emergency situations! You guy ran them for a whole ten minutes! Lol. What a freaken joke! There's several far better and detailed true tested reviews out there!

    • @kirkstinson7316
      @kirkstinson7316 ปีที่แล้ว

      Yes there are and Generac usually loses in them. I've been a generator mechanic for over 30 years and work on all brands. I've seen more total failures on Generac than any other brand. Generac has also had several class action lawsuits against them

    • @trith72
      @trith72 11 หลายเดือนก่อน

      @@kirkstinson7316 hat's because there are more generacs installed than any other permanent type by a factor of 5 so sure you will more failures, they are the most common brand. Now to say they FAIL more than other brands is disingenuous.....