Fire safety in commercial buildings demands more than just compliance-it requires reliable and responsive systems that protect occupants effectively. In this video, we walk through the essentials of controlling fire systems using the ABB ACH 580 drive, focusing on critical areas like stairwell and elevator pressurization. You’ll learn about the key role of stairwell pressurization fans, pressure transducers, and how these components work together to maintain safe evacuation paths during a fire event. We also address the impact of the 2012 Disabilities Act on building fire safety, ensuring technicians understand both the technical and regulatory dimensions of their work.
One crucial takeaway: getting your fire contractor involved early in the project can make all the difference in seamless integration, code compliance, and ultimately, occupant safety. For HVAC pros, mastering the setup and troubleshooting of these systems is essential. Tune in to gain practical insights and real-world guidance on using the ACH580 drive to build a safer, compliant environment.
Visit MRG's website at www.mechanicalresource.com to learn more about our services.
You can also find us on social media:
Facebook: MechanicalResourceGroup
LinkedIn: www.linkedin.com/company/mechanical-resource-group/ and www.linkedin.com/showcase/mechanical-pros/
Twitter: MechResource
Keywords: HVAC tutorial, cooling, skilled trades, engineering, construction, facilities
#hvac #facilities #construction #mechanical #skilledtrades #mechanicalpros #MechanicalResourceGroup #engineering #maintenance
มุมมอง: 142

วีดีโอ

R-32 Refrigerant: Don’t Panic, Plan It!
มุมมอง 1.7K3 หลายเดือนก่อน
Refrigerant changes are coming, but there’s no need to stress. In this video, we talk through what you need to know about R-32-covering the right tools, its safety aspects, and practical ways to approach the transition. With a little planning, you can handle R-32 confidently and keep projects moving smoothly. Understanding what’s ahead makes all the difference. Visit MRG's website at www.mechan...
VRV IV Emergency Function and A1P Board - Compressors
มุมมอง 9686 หลายเดือนก่อน
So, you troubleshot a Daikin VRV IV and found the primary compressor has failed and is keeping the unit from operating. The Pros are here to show you how to access Emergency Mode on the A1P board, providing a clear, step-by-step guide to restore functionality and get the system back up and running smoothly. After your faults are cleared: Press & Hold the "Mode” button for 5 seconds or so. * Thi...
MCS Control Panels: Your Non-Proprietary Game-Changer
มุมมอง 844ปีที่แล้ว
Micro Controls Systems offers a versatile, non-proprietary solution, allowing you to tailor your control panel to your exact needs. Whether you opt for the basic package or prefer to customize in the field, the flexibility is yours. Unlike many panels on the market, MCS comes with a user-friendly touchscreen interface that's like having the entire chiller's vital signs right at your fingertips,...
Chiller Wisdom: Leveraging Group Know-How
มุมมอง 228ปีที่แล้ว
As a technician, joining a chiller group can be a game-changer for you. Here's the rundown: Troubleshooting: Got a head-scratcher of a chiller problem? Toss it into the group. You'll likely get a fix that's been field-tested and isn't in the manuals. Networking: It's not just about fixing chillers. These groups can connect you with folks who can throw business your way or share a lead on the la...
Ditching Wire Nuts: Reliable Motor Connections Explained
มุมมอง 1.9Kปีที่แล้ว
In the world of motor connections, following the rules is crucial. NFPA 79-2007 clause 13.5 9.2 is clear: "Electrical connections at motor terminal boxes shall be made with an identified method of connection. Twist-on wire connections shall not be used for this purpose." 📜 But what happens when motor terminal boxes keep getting smaller, making a solid connection a tight squeeze? 🤔 That's where ...
Critical Motor Connection: Why Wire Nuts Won't Cut It ⚡❌
มุมมอง 705ปีที่แล้ว
⚡💡 Wire nuts - they seem cheap and convenient, right? 💲🔌 But hold on! 🛑 When it comes to motor connections, they're a big no-no! ❌🔥 These little guys aren't cut out for the current and can lead to motor failure. 😱 Learn why NFPA 79-2007 clause 13.5 9.2 is a must-know for your electrical knowledge bank. 💡📚 #ElectricalSafety #MotorConnections #NFPA79 Visit MRG's website at www.mechanicalresource....
When the Job Gets Derailed
มุมมอง 491ปีที่แล้ว
We began our HVAC diagnostic mission geared up to tackle superheat and subcooling adjustments🌡️💧. However, we encountered an immediate challenge. Despite the condenser fan operating smoothly, the suction pressure unexpectedly plummeted to around 50 psi 🤔🔌. This anomaly triggered recurrent on-off cycles due to the low-pressure switch. In response, we swiftly transitioned into a comprehensive dia...
Electronic Leak Detector vs Evaporator Coil
มุมมอง 384ปีที่แล้ว
🔍 After applying Cal Blue spray to the joints and brazed sections without detecting any leaks, the next step in pinpointing a refrigerant leak using an electronic detector is to head straight for the evaporator coil. 🕵️‍♂️ Begin by removing the drain pan, ensuring it's dry, and then carefully insert the leak detector into the drain pan. 🩺 If the detector starts beeping in this area, you've succ...
Mastering the Art of Pipe Grooving: Setting Your Attachment Right!
มุมมอง 1.6Kปีที่แล้ว
When grooving pipes for HVAC systems like cooling towers and chillers, one thing you don't want is an inconsistent connection. That's why it's crucial to set your Groover attachment correctly. Using a Rigid Powerdrive 300 with a Rigid 975 Combo Roll Groover attachment, we'll guide you through the process. Remember, don't turn too quickly, or you might end up with an oblong groove that can compr...
Pipe Grooving: Tips for Consistent Connections
มุมมอง 305ปีที่แล้ว
Learn one of the keys to achieving perfect pipe grooves with a Rigid 975 in a sneak peak of our latest tutorial. Graham's advice ensures your grooves are consistently even and leads to reliable connections every time. Join us to enhance your pipe grooving skills! Visit MRG's website at www.mechanicalresource.com to learn more about our services. You can also find us on social media: Facebook: f...
Mastering Copper Pipe Flares: DIY Techniques for HVAC Pros
มุมมอง 5Kปีที่แล้ว
In our latest video tutorial, we're diving into the art of crafting perfect copper pipe flares for your HVAC projects. Step up your skills as we guide you through the steps of creating flawless flares using a clutch flare tool. Because when it comes to ensuring a leak-free system, trusting the manufacturer's flares isn't enough. Learn from the pros and avoid common blunders like forgetting to d...
Brazing and Soft Soldering: Techniques, Tools, and Tips
มุมมอง 1.1Kปีที่แล้ว
Explore the world of brazing and soft soldering with our comprehensive tutorial, designed for technicians seeking hands-on insights. 🔥 Follow our step-by-step guide as we delve into essential techniques, from mastering flame color to torch positioning 🔵🕯️, while utilizing tools like the sil-fos brazing rod and a B tank torch 🛠️🔗. But before we light up the torch, let's talk about a crucial foun...
Brazing & Soft Soldering
มุมมอง 238ปีที่แล้ว
Explore the fundamentals of brazing and soft soldering in this preview. Join us as we delve into the essential techniques that form the backbone of HVAC work. With a live demonstration on the horizon, get ready to enhance your skills and elevate your craftsmanship in the world of HVAC. Stay tuned for the full-length tutorial where we break down the process step by step! 🔥🛠️ Visit MRG's website ...
Compressor Autopsy #2
มุมมอง 1.1Kปีที่แล้ว
Our cutting-edge custom compressor cutter opener(a technical term, don't ya know?) is officially up and running. Tune in as we make the first incision into a failed compressor and discuss the clues that led to its untimely demise. 😱 From worn bearings to electrical anomalies, we are committed to uncovering the truth. 🔎🕵️‍♂️ As Quentin will tell you, "Compressors don't die, they're murdered". Fo...
Quick Guide: Browning Belt Tension Checker in Action! 🛠️🔍
มุมมอง 3Kปีที่แล้ว
Quick Guide: Browning Belt Tension Checker in Action! 🛠️🔍
Mastering Motor Maintenance: Correctly Greasing Bearings
มุมมอง 7Kปีที่แล้ว
Mastering Motor Maintenance: Correctly Greasing Bearings
Debuting the Ultimate Compressor Autopsy Station
มุมมอง 544ปีที่แล้ว
Debuting the Ultimate Compressor Autopsy Station
Eliminate A/C Condensate Damage with Proven HVAC Tools: P-Traps, Drain Guns, Pumps & More!
มุมมอง 715ปีที่แล้ว
Eliminate A/C Condensate Damage with Proven HVAC Tools: P-Traps, Drain Guns, Pumps & More!
P-Traps 101: Tools & Tips for Smooth Drains
มุมมอง 597ปีที่แล้ว
P-Traps 101: Tools & Tips for Smooth Drains
Mini Split Wiring: Your Guide for Peak Performance!
มุมมอง 18Kปีที่แล้ว
Mini Split Wiring: Your Guide for Peak Performance!
🔌⚡ Wire a Mini Split Like a Pro: Sneak Peek Inside the Ultimate Guide! 🛠️💨
มุมมอง 243ปีที่แล้ว
🔌⚡ Wire a Mini Split Like a Pro: Sneak Peek Inside the Ultimate Guide! 🛠️💨
Mastering Cooling Tower Setup: Key Installation Tips for Optimal Performance and Longevity!
มุมมอง 865ปีที่แล้ว
Mastering Cooling Tower Setup: Key Installation Tips for Optimal Performance and Longevity!
Unveiling the Power of the GPS DM-2 Demo Unit: Agglomeration in Action!
มุมมอง 310ปีที่แล้ว
Unveiling the Power of the GPS DM-2 Demo Unit: Agglomeration in Action!
The Full Potential of Your GPS DM-2: The Importance of Proper Placement
มุมมอง 140ปีที่แล้ว
The Full Potential of Your GPS DM-2: The Importance of Proper Placement
Simplifying Installation, Enhancing Performance: Centrotherm's Ventilation Pipes
มุมมอง 370ปีที่แล้ว
Simplifying Installation, Enhancing Performance: Centrotherm's Ventilation Pipes
Effortless Venting: Centrotherm's Hassle-Free Gasketed Design
มุมมอง 235ปีที่แล้ว
Effortless Venting: Centrotherm's Hassle-Free Gasketed Design
Essential Cooling Tower Safety: The Importance of Shutting Off Your VFD First!
มุมมอง 341ปีที่แล้ว
Essential Cooling Tower Safety: The Importance of Shutting Off Your VFD First!
Cooling Tower Gearbox Maintenance: Key Tips for Peak Performance
มุมมอง 982ปีที่แล้ว
Cooling Tower Gearbox Maintenance: Key Tips for Peak Performance
Efficient Condensate Management: How to Set Your Daikin Navigator to Forced Off Mode
มุมมอง 777ปีที่แล้ว
Efficient Condensate Management: How to Set Your Daikin Navigator to Forced Off Mode

ความคิดเห็น

  • @pauldegazon8545
    @pauldegazon8545 11 ชั่วโมงที่ผ่านมา

    what is the part number for the ios version?

  • @PCB.panel144
    @PCB.panel144 3 วันที่ผ่านมา

    How can i contact you i need PCB

  • @nozma6615
    @nozma6615 4 วันที่ผ่านมา

    i want to Controller IP setup, i made it as in manual, but when i go to web, it askes me user and password, i can't access web interface, does anyone know default password and user?

  • @prabhakarans9143
    @prabhakarans9143 12 วันที่ผ่านมา

    Type 4 service checker cost how much

  • @williamroldan2601
    @williamroldan2601 12 วันที่ผ่านมา

    I'm working on a Daikin iLINQ Controller looks like the one you are showing. I have 24V going into the controller, but I don't have any display on my screen. is the controller being bad?

  • @saml8585
    @saml8585 20 วันที่ผ่านมา

    Plz your meeter reading shows me correctly your meeter not clearly

  • @adn996
    @adn996 22 วันที่ผ่านมา

    Boa tarde ilustres o que devo fazer para ter uma oportunidade de fazer uma formação de programação, configuração e arranque ? Meu nome é Alexandre Kodila, Angola

  • @solankibharat8963
    @solankibharat8963 หลายเดือนก่อน

    Nice information

  • @mightymitch
    @mightymitch หลายเดือนก่อน

    hELLO HOW ARE YOU

  • @KevinSmith-ht4nm
    @KevinSmith-ht4nm หลายเดือนก่อน

    how do I turn of the microsecond 3 controller ,with out shut off, the engine power to the complete system,

  • @dsha2006
    @dsha2006 หลายเดือนก่อน

    Have you been following the lawsuit again GPS and their NPBI technology? I want to get the NuShield-R for my house, but want to wait and see if the claims in the lawsuit are proved (that GPS exaggerated or that the technology creates other VOCs).

    • @MechanicalPros
      @MechanicalPros หลายเดือนก่อน

      Google "Garner vs GPS" for more info As of September 27, 2024, the U.S. District Court for the District of Delaware issued a memorandum opinion addressing the case. In the class-action lawsuit against Global Plasma Solutions (GPS), the court granted summary judgment in favor of GPS on two of the plaintiff's fraud theories: 1) Elimination of COVID-19: The claim that GPS's ionizers could eliminate COVID-19. 2) Absence of Harmful Byproducts: The assertion that the ionizers do not emit harmful byproducts. The remaining fraud theory that survived summary judgment was: 3) Independent Testing: The allegation that GPS misrepresented its ionizers as being independently tested. The court declined to certify this remaining claim as a class action, citing concerns that individual issues would predominate and that the plaintiff would not serve as a typical or adequate class representative.

  • @soloch69
    @soloch69 หลายเดือนก่อน

    What training do I need to take to get the service checker 4 so I can purchase a software and a service check for at this time. I do have the Wireless that I using with my phone

    • @MechanicalPros
      @MechanicalPros หลายเดือนก่อน

      You have to be certified by a Daikin instructor and complete 2 trainings: Installation & Commissioning, and Service & Troubleshooting. These are in-person classes that Daikin or your local rep may host.

  • @soloch69
    @soloch69 หลายเดือนก่อน

    Great video keep them coming 🫡

  • @jonnigreen-o6s
    @jonnigreen-o6s 2 หลายเดือนก่อน

    Do we need a branch selector box for a non heat recovery system.?

  • @trailbagger9217
    @trailbagger9217 2 หลายเดือนก่อน

    Great explanations. My local HVAC tech couldn't solve my problem but this video did.

    • @MechanicalPros
      @MechanicalPros หลายเดือนก่อน

      That's awesome to hear! Not that your tech couldn't but...

  • @albertogiannotti5506
    @albertogiannotti5506 2 หลายเดือนก่อน

    What port stand for ?

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 หลายเดือนก่อน

    Amazon sells 2GB cards....the reason it has to be smaller is the larger memory cards compress the data too far for the MT3

  • @nunya___
    @nunya___ 2 หลายเดือนก่อน

    Working in a puddle of contaminated oil is not professional imo. Disassemble, clean, re-assemble on clean surface. *When to change oil: 1) I pull my a short vac with _old_ oil in the pump since it will get contaminated quickly anyway. Break vacuum with Refrigerant. Drain and fresh oil. 2) Pull a long vac (depends on the size of the system and contamination but, about 15 mins per lb of refrigerant). Break vacuum with Refrigerant. Drain and fresh oil. 3) Pull another long vacuum using micron gauge. Remove hose from vacuum pump (so no need to do the ""shut-down procedure shown in this video). Feed liquid into the high side using scale. 4) If there was a Burn-Out, I put in fresh oil and run 5-10 minutes to clean the pump. If not, I leave the oil in for next "short vac". But always fresh oil for long term storage. Also. I always break the vacuum on the high side and start my vac on the low side to pull moisture through the system in one direction. After 5-10 minutes I open the high side. I've used pumps for many years with no failures. Charge the oil to the customer.

  • @gotchaplumber
    @gotchaplumber 2 หลายเดือนก่อน

    Could you do video of taking wet bulb measurements with tool?

  • @gotchaplumber
    @gotchaplumber 2 หลายเดือนก่อน

    Thank you!

  • @mikeclarke3005
    @mikeclarke3005 2 หลายเดือนก่อน

    unless the unit has color coding I wire 240V units with black/Red for the L1/L2 power in line with residential power 240V scheme and white for signal green for ground

  • @JustDandyElectric-ub1ys
    @JustDandyElectric-ub1ys 2 หลายเดือนก่อน

    Very good video, clearly spoken and no BS.

  • @threeleft16890
    @threeleft16890 2 หลายเดือนก่อน

    Where is your video on the part winding control's

  • @solankibharat8963
    @solankibharat8963 2 หลายเดือนก่อน

    Nice information knowledge hvac course details online available

  • @borabora5238
    @borabora5238 2 หลายเดือนก่อน

    Does it detect R449 (freon XP40)?

  • @solankibharat8963
    @solankibharat8963 3 หลายเดือนก่อน

    Nice information knowledge

  • @solankibharat8963
    @solankibharat8963 3 หลายเดือนก่อน

    Nice information knowledge

  • @corywilson4085
    @corywilson4085 3 หลายเดือนก่อน

    Which app did you use? Every app I find requires some sort of digital tool to link the app to.

  • @mannypetrinolis4007
    @mannypetrinolis4007 3 หลายเดือนก่อน

    Sooooo we have r32 now and we have to make something different right? American nickel heads at work. So I have to put a left hand adapter to the tank and then attach my right thread hoses on so when I tight it up the adapter will get a little lose so I can lose some Freon right? Got it. And the solution for the higher pressure of 32 vs 410 @100f degrees instead of making the cylinder a litle heavier we got a relief valve so as if I drive and it goes off blowing in the truck moving around it will stop right? No possibility of defects on the valves either. And…….we blame Chinese products because ours are so thoughtful? Also you didn’t mention about the single chemical if we can charge vapor instead liquid. But that is too much right? Thank god I am old and retired so I wouldn’t have to live among the people that come with these ideas.

    • @hbrits
      @hbrits 3 หลายเดือนก่อน

      Chill babygirl, it'll all be ok.

    • @KennethMayo-h9h
      @KennethMayo-h9h 3 หลายเดือนก่อน

      Nearing retirement this is all about money if it's so safe how come they have a shutt off sensor in the coil suppose it fails freon pockets what about a compressor terminal blow out it's still near the home and flammable

  • @supernova5107
    @supernova5107 3 หลายเดือนก่อน

    The ozone depletion potential involving the phase out of refrigerants like R11 and 12 was very Justified. All this global warming potential now with these refrigerants is a bunch of bull shit. The industry did a great job on phasing out the harmful refrigerants and now they got to find some other reason to control and manipulate the industry.

  • @TaylorFergusonMRG
    @TaylorFergusonMRG 3 หลายเดือนก่อน

    Great Video! I loved the thorough walkthrough of the new A2L Tanks and the explanation of how R32 Installations and Maintenance Differs from R410a.

    • @MechanicalPros
      @MechanicalPros 3 หลายเดือนก่อน

      Glad it was helpful!

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 3 หลายเดือนก่อน

    410a- 50% R32 50% R125. Daikin holds the patent on R32 and shares it for free to anyone to use. I work for Daikin Applied here in central TX. Proud to work for a great company.

  • @janeshure
    @janeshure 3 หลายเดือนก่อน

    Too the home owner it is just more stupid fu-king bull sh-t from the government.

  • @robertAWA
    @robertAWA 3 หลายเดือนก่อน

    So on a hot day when your r32 is burping in the van do I need to purge my van (enclosed space) with air before lighting a cigarette and driving home? Is the r32 refrigerant scented? I don’t smoke. Some of My fellow techs smoke though. 20+ year ago when I was an apprentice r22 was supposed to be LONG GONE by now, guess what, depending on the application and what’s going to be the best solution, if r22 is the best option I’ll go down to the supply house and buy as much as I need.

    • @TaylorFergusonMRG
      @TaylorFergusonMRG 3 หลายเดือนก่อน

      @robertAWA while R32 is considered flammable, it takes a particularly narrow range of concentration to be within range of ignition and more energy to ignite than one might expect. While the risk of ignition is much lower than that of Gas or Acetylene, it is recommended to not produce an open flame near a flammable gas.

  • @GhostlyShankemz
    @GhostlyShankemz 3 หลายเดือนก่อน

    Off topic, but Mr president you're staring into my soul.

  • @scott-vo4dy
    @scott-vo4dy 3 หลายเดือนก่อน

    Extremely douchey video with a little bit of leak detector sales info.

  • @alhernandez5929
    @alhernandez5929 3 หลายเดือนก่อน

    how do you brighten the screen? One i have operates chiller but screen is blank, despite having 24v.

  • @davidgieswein6657
    @davidgieswein6657 3 หลายเดือนก่อน

    Lots of good information here. What a great video.

  • @inganvf
    @inganvf 3 หลายเดือนก่อน

    Do you have to recover all the coolant from the chiller and weld the thermowells?

  • @jesusislord6773
    @jesusislord6773 4 หลายเดือนก่อน

    I wish you could use this tool on the normal Daikin Split system not just VRV..

  • @shaunchapman4163
    @shaunchapman4163 4 หลายเดือนก่อน

    Sounds like ur tool is the inacurate method

  • @AntinutellasFC
    @AntinutellasFC 4 หลายเดือนก่อน

    But the name of the video should be: how to struggle to break apart you mini split ac.

  • @hvacman954
    @hvacman954 4 หลายเดือนก่อน

    Great video. Thanks mechanical pros

  • @abdoulyaya4711
    @abdoulyaya4711 4 หลายเดือนก่อน

    pls do a video on programing the micro tec 111 via deskstop

  • @johngrayer7773
    @johngrayer7773 4 หลายเดือนก่อน

    Thanks, great video, got my first VRV install next week and what lead me to this video was that the manufacturer had said install the REFNET's vertically or horizontally and I understood that as the branches could be horizontally or vertically (but with the REFNET in a horizontal plane) and thinking about that it didn't make sense. This video confirms what I was thinking. Appreciate it.

  • @daviderquitt1642
    @daviderquitt1642 4 หลายเดือนก่อน

    My data sheet is located inside unit so should I go buy it ..410a system

  • @UncleEarlHeatingAirCondition
    @UncleEarlHeatingAirCondition 4 หลายเดือนก่อน

    Thank you for sharing, much helpful. Is there a cheat sheet that you can provide that shows all the temp ranges you mentioned?, or will the ranges change depending on the type of systems?

  • @JacekWrona-s1v
    @JacekWrona-s1v 4 หลายเดือนก่อน

    Great informational video. I hope you can help me. I have 14 seer evaporator coil and 15 seer Carrier condenser (no matching system .I know that) There was original piston (0.088) in the unit ,but after the Carrier condenser was install, piston was replaced by TXV. Unfortunately ,randomly compressor is overheating , so I planning to put the piston back . And new piston is 0.090. What's your take on that?

  • @woahitskarilyn
    @woahitskarilyn 4 หลายเดือนก่อน

    You explained this so succinctly. I work maintenance on a facility with 40+ WSHPs in the ceiling, over half of which are tripping out on high condenser water temps. This is about to be my next weeks' worth of work. Thank you for making this video!

  • @kirkhemmings8234
    @kirkhemmings8234 4 หลายเดือนก่อน

    Beautiful i Love everything i Love your work it is very important you are the best