- 14
- 28 421
Peter M
เข้าร่วมเมื่อ 28 มี.ค. 2011
Kawasaki ER-6F 2014 Ixill Hyperlow sound with no DB Killer
Ixill Hyperlow sound with no DB Killers
มุมมอง: 49
วีดีโอ
Kawasaki ER-6F 2014 Ixill Hyperlow sound (one DB Killer)
มุมมอง 1358 หลายเดือนก่อน
Ixill Hyper low with one DB Killer out
Kawasaki ER-6F 2014 with Ixill Hyperlow full exhaust
มุมมอง 1598 หลายเดือนก่อน
Kawasaki ER-6F 2014 with Ixill Hyperlow full exhaust Check the sound of the bike with one DB Killer out th-cam.com/video/tq9HYBl_b8E/w-d-xo.html and with both DB Killers out th-cam.com/video/5ucKY8b6wWE/w-d-xo.html
Maas SPS-250 II faulty
มุมมอง 124ปีที่แล้ว
Faulty Maas SPS-250 II power supply, not working. After power on, the voltage is showing about 2V, the fan is not spinning and you can hear a buzzing noise. After switching it off, the volts are still staying around 2V for a while, until the buzzing sound stops (probably when capacitors are fully discharged). Any idea which parts can be faulty? I've seen couple of this power supply with the sam...
JK BMS no RS485 communication
มุมมอง 14K2 ปีที่แล้ว
JK BMS, all functioning apart from RS485 port. No comms to/from bms on the rs485 port
Victron ESS with ET112 grid meter
มุมมอง 6K4 ปีที่แล้ว
Victron ESS with ET112 grid meter, showing slow response on load change Load switched on at 15s of the video and switched off at 43s. Victron needs over 15 seconds to stabilize after 1400W load change. If you have any idea how to improve this slow response please leave your idea in the comments
Victron ESS + ET112 cloudy day
มุมมอง 1.5K4 ปีที่แล้ว
Victron ESS ET112 in a cloudy day Victron slowly respond to load change. It supposed to keep grid power at -10W , but it hardly ever maintaining this level. Any idea how to improve it? Leave it in the comments. Thx
Strange Noise
มุมมอง 6529 ปีที่แล้ว
2.0TDI CR 140KM DPF (CFHC) Strange noise coming from under bonnet (12s & 55s of the video)
What are your settings in ve config when using ct? Mine doesn’t show up anywhere and back feed is allowed even when set to +110watt in Ess? External meter checked?
What are your settings in VE configure with external current sensor box and your grid code
In case of an CT the settings should be Internal/Inverter
i have also jk b2a24s20p bms i am also trying to rs485 but i am facing issues
Did you solve this problem? I am seeing the exact same problem trying to hook up with Solar Assistant.
Where did you get the cable from bms to the cerbo?
Hello sir I have JK BMS "JKB2A24S20P" i am trying to decide the RS485 of that BNS. But unable to do it.? Will you tell me how i do it ?
Hi Peter - Did you resolve your issue? What model of BMS are you using and how did you convert the RS458 signal to CAN for the inverter to detect the JKBMS?, Get back at me as i might need your advice...
Jk bms to sorotec inverter? Via rs 485
This BMS is connected with Victron inverter
HI ! can you tell (us) please what software and parts , cable from Bms to pc , appreciate thx. ! in my country sell this about 150 euro and think is exaggerated..
lifepo 4 battery has its BMS INSIDE THE BOX IT WAS READ MADE FROM ALI EXPRESS AND THE INVERTER I HAVE IS LITHIUM ION BUT NO SOLAR CHARGE CAN YOU HELP ME. TO FIX
What is the software used to monitor BMS using RS485 ? can you share the code?
To monitor BMS you can use mobile app from JK, the software on the video is from Victron system
Jk BMS can be connected with growatts SPF 5000es?
It has been done on youtube, need to change protocol on inverter and maybe bms. Have you got it working yet? I want to connect to spf 3500 es.
Can jk bms communicate with arduino? Do you have any information about this subject? I need to process the voltage and current values of the battery on the arduino.
did you learn that? if yes please help me a little
But wher can I get the little white plug for the bms? How is the name of the plug?
JST GH1.25mm male SMT Connector 4 Pin spacing 1.25mm
Go to the third menu and enable RS485 and not CAN
This has nothing to do with the settings, this BMS RS485 module was faulty and it was replaced under warranty
@@mpeter2012 Hi Peter, it looks like I have exactly the same problem. RS485 worked fine for several weeks, but now it doesnt response any more. How did you manage to get a warranty replacement? Is it possible to replace just the communication module or did you replace the whole BMS?
@@thomaswurm3929 I've replaced the whole BMS. I had spare anyway so was not an issue. I didn't claim any warranty on the faulty one, I'm using it in the application where the rs485 communication is not needed
Did you go back to the CT method or stay with energy meter?
I moved back to CT clip to get better response. For me it is more important to have better response than energy usage accuracy
it's more of a power supply problem
Yes you are right, I've tried different power supply and it is running fine
Invest in USB isolators. If ANYTHING goes wrong with your grounding powerful current surges can destroy some expensive equipment.
Just resolved same issue. JK is working in TTL RS not RS485 mode ! And speed is 115200. This may be a bit too much for normal cabling system ( as on video). Just place converter to USB as close as possible to BMS and use USB extension cable. This worked for me.
I'm using original TTL to RS485 converter from JK, the cable is absolutely fine. I've checked it with 3 different BMS's and it was working without trouble. The problem was just it this one BMS on the video. It turns out that the BMS has faulty rs485 module.
Unplug the CAN port and try
this is RS485 BMS version... CAN port is not in use, there is nothing connected to it
Hello, the same thing happens to me, what is the problem?
The problem is faulty longmon
Das ist das beste was es gibt 🤗👍
And? Did it solve the problem?
turn the switch on the inverter to I instead of II or disable the low power mode if it is enables (aes) in the victron config tool.
Peter. I installed my et112 but there is no loads in AC loads displayed. It's always 0. Do you know where is the problem?
do you have any news on the behavior "ct" and "rt112"?
unfortunately there is no update