RefrigerationJohn
United States
เข้าร่วมเมื่อ 12 ก.ย. 2017
Hi there just some daily service calls I’m called out to and some EMERGENCY calls also. Maybe you can find some tricks or tips or give some let me know and thank you for watching
PAN CHILLER Taco Station(NOT WORKING)
Found unit dirty had to clean, restarted unit low on gas, leaked checked unit, found suction line flare leaking repaired, upon further inspection found the steam for valve leaking had to replace valve along with gasket, pulled vacuum, recharged, restarted, watched unit pull down to temperature all ok.
#hvacr #hvacrtechnician #hvacrepair #maintenance #refrigeration #refrigerationandairconditioning #refrigerationcycle #refrigerationengineering #refrigeration_ #refrigerationequipment #refrigerationtech #refrigerationequipment #refrigerationsystems #refrigerationsystem #foodequipment #taco #station #tacotuesday #coolerrepair #cooler #cooledit #cooling #coolingsystem #coolingexperts #cool #servicetech #service #servicetechnician #tech #technician #cleaning #cleared #clean #cleaningmotivation #clips #dirty
#hvacr #hvacrtechnician #hvacrepair #maintenance #refrigeration #refrigerationandairconditioning #refrigerationcycle #refrigerationengineering #refrigeration_ #refrigerationequipment #refrigerationtech #refrigerationequipment #refrigerationsystems #refrigerationsystem #foodequipment #taco #station #tacotuesday #coolerrepair #cooler #cooledit #cooling #coolingsystem #coolingexperts #cool #servicetech #service #servicetechnician #tech #technician #cleaning #cleared #clean #cleaningmotivation #clips #dirty
มุมมอง: 98
วีดีโอ
Walk In Freezer(NOT COLD)
มุมมอง 70112 ชั่วโมงที่ผ่านมา
Found bad thermostat, replaced, also notice sensing bulb for power head not mounted, corrected, checked ops on roof, washed down & degreased condenser coil, restarted watched unit pull down, recommended follow up to checked super heat, verify temperature. #hvacr #hvacrtechnician #hvacrepair #refrigeration #freezer #foodequipment #frozen #frozenfood #refrigerationandairconditioning #refrigeratio...
Walk-In Cooler(WARM)
มุมมอง 33119 ชั่วโมงที่ผ่านมา
Found unit low on gas, leaked checked unit found dual pressure control leaking, repaired, re leaked checked all ok, topped off watched unit pull down to temperature, all ok. #hvacr #hvacrtechnician #hvacrepair #leakrepair #leak #refrigerationtech #refrigeration #refrigerant #refrigerationandairconditioning #refrigerationcycle #refrigerationengineering #refrigeration_ #refrigerationsystem #refri...
2Drawer Cooler(NOT WORKING)
มุมมอง 129วันที่ผ่านมา
Found unit low on gas leaked checked system and found evaporator coil leaking, recommended to replace, upon further inspection found bad electronic thermostat, replaced along with wire & secured to wall, restarted watched unit pull down to temperature all ok for now. #hvacr #hvacrtechnician #hvacrepair #refrigeration #refrigerationtech #refrigerationandairconditioning #refrigerationcycle #refri...
Prep.Cooler (WARM)
มุมมอง 117วันที่ผ่านมา
Found unit in defrost and condensing unit still running, checked ops found bad controller, replaced, program. Restarted, watched unit cycle on/off all ok. #foodequipment #coolingsystem #coolingequipment #cooler #coolerrepair #controller #cold #refrigeration #refrigerationtech #refrigerationandairconditioning #refrigerationcycle #refrigerationengineering #refrigeration_ #tech #service #servicetech
How To Diagnose BAD Thermostat/Replacement
มุมมอง 180หลายเดือนก่อน
How To Diagnose BAD Thermostat/Replacement
WALK-IN FREEZER(WARM & ICE MACHINE NOT WORKING)
มุมมอง 268หลายเดือนก่อน
WALK-IN FREEZER(WARM & ICE MACHINE NOT WORKING)
It looks like cake
Put it subtitles, please, thank you
Coloque subtítulos Put it subtitles, please
JLL tag?
Good find…👍
Thank you
this is the best kinda call, besides a breaker being off lol
😂 yes sir and on O T
Nice work John.
Thank you sir
You da man
Thank you sir
No spar, because the jerk filter changer guy took them 😮😮
Replace your sheeves or pulleys
Thank you sir
where did you buy the bushings???
I replaced motor along with capacitor
Poor coil needs retirement😭
¡ Nice catch on that hard to see solenoid stem leak!
¿Wonder why the 180 bend after the solenoid?
Is this the Bronx ? Bullet hole in coil call
I use hot water in pump sprayer
Чем растапливаешь лёд на испарителе ?
Damn.
Goodshit bro 👍
Thank you sir
I would like to see a wider video
I've made some of the most ridiculous looking condensate loops! Bit of a guess on what the charge is, between that and the oversized drier😂
Bro I had the same unit about a month ago with a leak in the same exact spot, within an inch! crazy
Nice! lol 👌
That evap was disgusting. Board of health violations. Around food yet. Makes me sick to my stomach
Thanks for posting.
You're welcome. And thanks for watching.
Is that switch in the condensate a high level cut out?
In the condensation pan? It’s a heater limit switch
@@RefrigerationJohn forget the brand but had seen a float type switch before.
@@davejohnsonnola1536 I came across that one time on a newer unit
th-cam.com/video/Q0CVXfBxCF0/w-d-xo.htmlsi=DNdfG_M3cldWIuIG
Compresser is bypassing.
Thank you for letting me know
Does it not make more sense to just replace the whole motor……. Then you have new everything not just bearings?
THANKS FOR SHARING.
Thanks for watching!
Wow nice save,that was great.I normally use the torch,heat up the metal and open the oxygen,cut around the line and use a dremel to cut the ring.
Cool, thanks, great tip. That sounds a lot better I’m gonna have to try that one 👍
The 45's are fine = tightening the wires and new contactor likely solved the over-amp
Thanks 👍
I have trashed a few of those gimmick rollers.
Well done sir
Thank you sir
Great video. Thank you for sharing
Thanks for watching!
Nice work,maybe checking heat ex-changer,just in case?
Thanks for the tip!
Ice cream rolls 😊
for my own satisfaction i would have tried to roll it down all in one sheet 😅
I saw a guy light it on fire
Nice work,they give you all the easy ones.NOT.
Thanks 👍. lol
I'm sorry but you should have turned the unit off used a h wet and dry vac and sucked all that off around the outside of the coils and they use the regular green chemical or the coil cleaner to spray that down and a water hose sprayer to spray it from the inside out
Brush it first? I think we should just cut the brush out of the equation and use the shop vac with the soft tip 😂 Jesus that thing is packed full
Rookie
Watch the coil next time wash the condenser viper
Thanks for the tip
I work with a guy that is a pro at fixing micro channel coils
good work.
Thanks!
One of my local restaruants just pours ice into the top lol
👏👏👏👍
Float that maintains water level is stuck or out of adjustment. Like all things mechanical, routine inspection and maintenance is required for proper operation.
I hate it when my leak detector doesn't pick up a nitro charge
Ya aren't you soppos to hit it with refrigerant and nitro?
@SilverandCigars yea a little
you have a bad run cap,that is why the high amps at start up..hope that helps.
Nice, thank you sir, yes helps out 👍