  • 797 549
How To Set Up And Prime Your 3" Trash Pump
How To Set Up And Prime Your 3" Trash Pump
-How to connect hoses
-How to Prime Pump Case
-How to Prime Lines
*If pump still will not prime after following the steps, check that your intake hose clamps are tight enough on the hose barb to prevent any air leaks.
*If no air leaks are detected on intake system you may need to replace your ceramic seal behind your impeller. You can see a video on how to do that bellow.
th-cam.com/video/0TowEXTRfc4/w-d-xo.html
มุมมอง: 4 003

วีดีโอ

Volt 4in1 General Information
มุมมอง 3K2 ปีที่แล้ว
General information on your Volt 4in1 generator Visit us at: WWW.MACLETECH.COM Email: Tyler@macletech.com
Portable Generator End Testing (AVR & Brush)
มุมมอง 215K4 ปีที่แล้ว
In this video we will show some simple ways to test and narrow down the issue with low or no output on a AVR & brush gen end. If you need parts or readings contact your generator manufacture and if one of your units is one we support you can visit us online at WWW.MACLETECH.COM EMAIL: TYLER@MACLETECH.COM
Quick tips before running your generator that has been sitting up.
มุมมอง 5K5 ปีที่แล้ว
A few things to look over prior to use, to make sure your generator functions for the longevity that you will be needing it during a storm or general use. Contact us: * macletech.com * tyler@macletech.com * Our company only carries parts for the brands we support but I would be glad to answer any questions over e-mail
How to take apart a twist fan pressure washer tip
มุมมอง 1.5K6 ปีที่แล้ว
How to take your tip of your pressure washer wand apart to inspect,clean or unclog. visit are online store at www.macletech.com/ E-mail me at tyler@macletech.com
9000MTB general information
มุมมอง 8K6 ปีที่แล้ว
Info for 9000 toolbox style generators, how to and location of things such as, oil drain, block numbers , fuel shut off, carb, choke , starter location Specs: Rated Volt:120/240 Rated Max amp: 27 Rated Power: 5500kw Rated Max Power: 6500kw Rpm:3000/3600 Oil: 10W30 Oil Capacity: 26/28oz Fuel tank Capacity: 11 Gallons Contact us: * macletech.com * tyler@macletech.com * Our company only caries par...
How to Clean Typhoon blasting tip
มุมมอง 2176 ปีที่แล้ว
How to clean, dissemble and reassemble Typhoon blaster blasting tip. macletech.com/ www.typhoonblaster.com/ Customer Service: 1-866-588-9361 Sales: 1-888-561-2123 Email: Kurt@typhoonsc.com Hours of Operation: M-Th / 8AM-5:30PM (EST) F / 8AM-11AM (EST)
Typhoon Blaster 4000 psi Cat pump Installation tutorial
มุมมอง 5K6 ปีที่แล้ว
How to install the 4000 psi cat pump with throttle cable on the Typhoon blaster. macletech.com/ www.typhoonblaster.com/ Customer Service: 1-866-588-9361 Email: info@typhoonsc.com Hours of Operation: M-Th / 8AM-5:30PM (EST) F / 8AM-11AM (EST) Music Credit Feelin Good by Kevin MacLeod is licensed under a Creative Commons Attribution license (creativecommons.org/licenses/by/4.0/) Source: incompete...
Changing out old style solenoid carburetor to new style on a generator
มุมมอง 15K7 ปีที่แล้ว
How to remove your old style pull/push ring choke style w/ solenoid carburetor to the new style carburetor with a lever choke www.macletech.com E-mail tyler@macletech.com
Portable Generator end Testing (Brushless) LCT brand Diesel
มุมมอง 539K7 ปีที่แล้ว
Ways to check your capacitor,ohms,diodes on a small portable gen end. macletech.com tyler@macletech.com Our company only caries parts for the brands we support (LCT, Wuxi, Launtop) but I would be glad to answer any questions over e-mail. Note:The reading stated in this video are not necessarily the reading's for your end, for the readings on the generator end that you have call manufacturer of ...
Tp300 Ceramic seal replacement
มุมมอง 9467 ปีที่แล้ว
Instructional on how to disassemble and reassemble a TP300 trash pump along with changing out the ceramic seal. NOTE: When replacing ceramic seal make sure the 2 surfaces of ceramic are extremely clean to prevent any leaking. macletech.com

ความคิดเห็น

  • @akwaberlin9930
    @akwaberlin9930 5 หลายเดือนก่อน

    Great 👍

  • @Mark-wx1ho
    @Mark-wx1ho 6 หลายเดือนก่อน

    Great video. The best on here for this type of fault. I have ordered a new AVR. Thanks.

  • @weepeeteeee
    @weepeeteeee 2 ปีที่แล้ว

    Do you support Kubota generator?

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      No sorry we do not

  • @paulkerling1834
    @paulkerling1834 2 ปีที่แล้ว

    I have 110 on only 1 plug on my 220 output?

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      If you test directly off of the end is it producing 220v ? If so then the problem is either in the wire that feeds the plug or the plug itself.

  • @alexbuckingham7854
    @alexbuckingham7854 2 ปีที่แล้ว

    Excellent video...thanx! Is there a way to test just the AVR in order to see if it's working or not? (I am a novice at generator repair, and my 6.5KW 220v gen suddenly has no output power). Thanx & Regards, Alex Cape Town.

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      I myself have never found a way to correctly 100% test a AVR, other than the 12v to the brushes to give you a 50/50

  • @brentablett7845
    @brentablett7845 2 ปีที่แล้ว

    Enjoyed your video. Good step by step with really good info like why the gaskets go the way they do, how to make sure the governor lever and springs are right, importance of the OHV cover tube. Slow enough to understand but quick enough so it's not a 25 min watch! Not just useful for this job but any similar carb disassembly/reassembly. Keep it up!

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      Thanks for watching!

  • @vecinaso
    @vecinaso 2 ปีที่แล้ว

    nice thanks a lot

  • @mcarriaza
    @mcarriaza 2 ปีที่แล้ว

    Very helpful video Keep up the good work

  • @EvaderGuy
    @EvaderGuy 2 ปีที่แล้ว

    Good video. Thanks.

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      Glad you liked it!

  • @kennywaynesdiy
    @kennywaynesdiy 2 ปีที่แล้ว

    What’s up man. Great video. I’m getting 90v through my brushes. What would cause that?

  • @robairelafave7847
    @robairelafave7847 2 ปีที่แล้ว

    Briggs & Stratton generator ran out of gas under load, upon filling and restart, (which I believe was done under power) it blew several control boards on appliances, garage door openers etc…. Voltage tested properly from generator, but lights were coming on and off, as if AVR was toast??? What do you think?

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      Could be the AVR if the power kills every 30 seconds or so, AVR usually resets every 30 seconds

  • @jimsandifer7697
    @jimsandifer7697 2 ปีที่แล้ว

    Outstanding I understood ever detail on how to test my cat 8000E. Very clear and cool way to do a youtube everyone needs to watch this guy is great. Thank You

    • @mactech8975
      @mactech8975 2 ปีที่แล้ว

      Glad it was helpful!

  • @2_be_determined
    @2_be_determined 2 ปีที่แล้ว

    Great info thanks for your help sir

  • @jonathanmonger111
    @jonathanmonger111 2 ปีที่แล้ว

    You did extremely well. This was the best video for troubleshooting generator motors.

  • @grimlawdmoney5080
    @grimlawdmoney5080 3 ปีที่แล้ว

    My brother I have a generac ET 2400 generator and I need some help on how to connect the capacitor, I don’t want to just connect things that I don’t know much about. Can help me on that?

  • @deuceman0242
    @deuceman0242 3 ปีที่แล้ว

    Great video, so I tested my brushes output and I'm getting 70 volts AC. Rotor is toast I guess?

  • @TheOriginOfEverything
    @TheOriginOfEverything 3 ปีที่แล้ว

    thanks !

  • @buddyboy4x44
    @buddyboy4x44 3 ปีที่แล้ว

    Good review. Thank you.

  • @ivansmith6737
    @ivansmith6737 3 ปีที่แล้ว

    Good explanation except the out put voltage on the excitation windings.e.g between yellow + yellow and Brown+blue.Also want to know how t bench test the AVR.Contact me on smithivan772@gmail.com

  • @craigdreisbach5956
    @craigdreisbach5956 3 ปีที่แล้ว

    Wow! Great teaching. Thank you Kind regards, Craaig

  • @robschmoe2504
    @robschmoe2504 3 ปีที่แล้ว

    i need a head gasket an manual model 8055 titan diesel generator

    • @mactech8975
      @mactech8975 3 ปีที่แล้ว

      you can give us a call @ 1-800-845-4141 we support titan diesel parts

  • @MrGoldman9
    @MrGoldman9 3 ปีที่แล้ว

    Hello there what is the difference between the AVR and the capacitor so is this is considered as a capacitor Or just a voltage regulator?

    • @mactech8975
      @mactech8975 3 ปีที่แล้ว

      yes there is a difference. Read this blog powerinsiderpro.com/avr-vs-capacitor-generator/#:~:text=Well%2C%20the%20AVR%20generator%20is,capacitor%20in%20a%20capacitor%20generator.&text=The%20capacitor%20generators%20are%20cheaper,is%20the%20overall%20better%20generator.

  • @LA-TEEZI
    @LA-TEEZI 3 ปีที่แล้ว

    Excellent video! I have surging power at my outlets on a 2200 watt generator. Produces power for a second, then no power, keeps repeating. When I run 12v to the brushes, everything works as it should... what could it be? Thanks in advance

  • @andrewraymond6223
    @andrewraymond6223 3 ปีที่แล้ว

    Thanks. Very helpful

  • @MittyNuke1
    @MittyNuke1 3 ปีที่แล้ว

    Thanks for the video. I bought the engine shown in this video from someone who said the generator he had broke and he had taken the engine off, given the electric start motor to a friend, and sold the engine (to me). I hear it's very common for these generator ends to fail, and knew there wasn't a lot involved with fixing them. Of course, I'm happy I got a reasonably priced engine. :D Question -- is this unit really made by the LCT/Liquid Combustion Tech company, or is it just a Chinese knockoff using a well known company name? Reason is, I could not find any mention of this diesel engine on the LCT company website. Also - does this engine come with a flywheel-mounted DC charging coil for the electric start battery, or is the engine-mounted voltage regulator powered from the generator end diodes? I can't see any wires coming from where the charge coil is normally installed, and have purchased a new charge coil and permanent magnet rotor to install to allow the engine to keep a starting battery charged since I've re-purposed the engine for use on a wood chipper. The engine has a DC voltage regulator attached to it, but the leads had been clipped and I didn't see the 2 leads coming from where the flywheel rotor is usually installed, so I'm going to have to pull the flywheel anyway, but was just curious if they normally tap off the exciter coil/diodes to avoid the need to install an engine-mounted coil. Thank you for showing how to fix the generator end. I have a gas powered Winco generator which is having trouble starting motors far below the rated power so think I may eventually troubleshoot that unit using the info you presented here. Much appreciated.

    • @mactech8975
      @mactech8975 3 ปีที่แล้ว

      As far as LCT they no longer manufacture or import the diesel because of EPA regulations, the DC voltage regulator gets its power off of the two blue wires(there should be two sets) on the gen end, it should have a connector the same as your DC connection. Most of the units have a extension wire that goes from the gen end to the DC regulator.

  • @kennywaynesdiy
    @kennywaynesdiy 3 ปีที่แล้ว

    Great video. I learned a good bit. I have a generator that shakes like hell when the capacitor is hooked up but runs smooth when it’s out. It’s a brushless gen end. Anybody had a problem like this?

    • @mactech8975
      @mactech8975 3 ปีที่แล้ว

      Most of the time that means your gen end is shorting and the engine is trying its best to keep up with the load.

  • @beckettcohen5493
    @beckettcohen5493 3 ปีที่แล้ว

    Hey Tyler I need a little help. (Great vid btw) my portable generator is a 12,000 watt 120/240. My question is can any generator of this type (no switch to transfer from just 120-120/240 volts it’s always 120/240) however what’s the reason they tie all the common wires on the r1 stud and can I re wire mine So all the common wires are on R1? And if I can what can I expect as far as performance I.e. wattage , volts , etc P.s. it is, an AVR style generator like yours in the video. Thanks so much for any input or help you can offer. Thanks Tyler

    • @mactech8975
      @mactech8975 3 ปีที่แล้ว

      In my opinion the only reason they tie them all together is to save money. When they are tied together like that it can cause a slight back feed and drop performance. If any re wiring was to be done i would add a extra common coming from your cont panel and match it to the correct wire on the main board on the gen end.

  • @richardpope9985
    @richardpope9985 3 ปีที่แล้ว

    So, the AVR is actually regulating the main AC output voltage, by regulating a DC voltage that goes to the rotor coils ? You put 12vdc to the rotor coils, that resulted with 57vac main output. So, I'm assuming about 26 ish vdc to the rotor coils , would create the desired 120 vac ? I would be curious to see the actual voltage the AVR sends to the rotor coil. BTW, Great video.

  • @richardspatola349
    @richardspatola349 3 ปีที่แล้ว

    Good video - suggest you could say a word or two about the new choke - which way the lever should be when starting, etc.

  • @allenj.7256
    @allenj.7256 3 ปีที่แล้ว

    well done! if you ever want hvac instructions just let me know.

  • @raymondgarafano8604
    @raymondgarafano8604 3 ปีที่แล้ว

    Hello MacleTech, If I understand this right, the rotating field in a brushless gen has 2 sets of windings? one set sakes in a.c. sent to a fw rectifier bridge and sends d.c. to the other winding? The capacitor is used to hold a charge on the stator windings so rotating field will have a voltage induced in it when it starts to spin, that a.c. is turned to d..c to make a stronger field for the generator to build up.

  • @yahaiya7400
    @yahaiya7400 3 ปีที่แล้ว

    Thanks a lot for all this really useful information

  • @fredshead7114
    @fredshead7114 3 ปีที่แล้ว

    Hi there can you tell me how the power gets to the rotor winding and what those diodes do and what there connected to? and how its regulated from Fred in England

  • @harishdoodnauth4932
    @harishdoodnauth4932 3 ปีที่แล้ว

    Thank you very much I learned a lot

  • @houseoffolly
    @houseoffolly 3 ปีที่แล้ว

    Best step by step generator diagnosis video so far and I've watched a few.

  • @facab1974
    @facab1974 3 ปีที่แล้ว

    Hi. What about the "S" conector, two wires come from there, same like the capacitor but those cables goes to a black box to the main panel. Any idea of the fuction it has?

  • @sshawn09
    @sshawn09 3 ปีที่แล้ว

    Tyler, you are the man, I now understand how my genny works and what can potentially go wrong with it.

  • @TractorWrangler01
    @TractorWrangler01 4 ปีที่แล้ว

    Exellent tutorial. However you skipped over how to match your hertz to your voltage and engine speed. For example if your hertz are at 70 and you need them at 60 but your voltage is 120 @ 70 hertz. when you adjust your engine speed down to 60 hertz now you have 105 volts or so. I liked your video it was spot on.

  • @JulioASoria-sd2nu
    @JulioASoria-sd2nu 4 ปีที่แล้ว

    Thanks! Good explanation!

  • @Sipho-Msayi
    @Sipho-Msayi 4 ปีที่แล้ว

    Great information shared here, thank you

  • @wxfield
    @wxfield 4 ปีที่แล้ว

    Also..if you have a working generator it doesn't hurt to take the cap off and record the ohms of the stator with a sharpie on the generator housing for future reference.

  • @raymondgarafano8604
    @raymondgarafano8604 4 ปีที่แล้ว

    Some generators of the 'BRUSHLESS' have a rotor with double windings, connected together by a set of diodes or rectifiers/bridge. The rotor spins within a slight magnetic field building up alternating current which in turn is changed to D.C. and creates a powerfull field on the 2 faces or poles of the rotor. As you know, a diode prevents current flowing in one direction, yet allows in the other direction, like as my friend Taryl says, an electrical check valve. The fixed winding/s are known as the 'ST8or or Stator, the part that turns is the revolving field known as a rotor. This whole assembly is in ways similar to the alternator in a car. the rotor here being of 2 poles only while the rotor in the car has a number of toothlike poles, but then again, the car alternator is delivering 3 phase power and changing to D.C. by means of the bank of diodes. The AVR here is similar to the voltage reg. in a car, the lower the btter gets due to the load placed on it, more field is applied to the rotor thu, yup the sliprings. No matter how many KW at a given voltage, over-curent must be avoided, that is why fuses or circuit breakers are employed.

  • @muktarulhasan8987
    @muktarulhasan8987 4 ปีที่แล้ว

    my same generator starting no problem but no out put power,,please solve this problem

    • @TractorWrangler01
      @TractorWrangler01 4 ปีที่แล้ว

      First you need to try flashing it. Some generators dont have a perminant magnet on the armature and it can cause an issue with the lack of a magnetic charge to start the process. That should always be the first step if your getting no power because it requires no disasembly. start the generator and plug in a drill, hold the trigger in and spin the chuck to turn the drill motor over by hand. If that is the problem after a few times doing that the drill should just take off and start spinning on it own. I dont know if this one has the magnets or not but giving it a try cant hurt. Then follow this video for doing your testing.

    • @ghulamrahmani2326
      @ghulamrahmani2326 3 ปีที่แล้ว

      Check AVR good or not

  • @christinamoneyhan5688
    @christinamoneyhan5688 4 ปีที่แล้ว

    That young man was a very good explanation of the troubleshooting of the generators that I have ever came across. Clear and concise. Thank you for sharing your knowledge of these units.

  • @Drilldowntofacts
    @Drilldowntofacts 4 ปีที่แล้ว

    Mr. Tyler, it was great to see you in live demonstration. Finally and late to get back to 5500 diesel generator repair. Installed the tank valve. Good information on troubleshooting my low voltage on generator. I will see to it and get back in touch. Hope I won't need any diodes.

  • @ronmoz5815
    @ronmoz5815 4 ปีที่แล้ว

    thank you for the information sir.

  • @Thunderroad8517
    @Thunderroad8517 4 ปีที่แล้ว

    Good video! Are you still replying to comments????

    • @mactech8975
      @mactech8975 4 ปีที่แล้ว

      I try to when I can, best way of contact is E-mail.

  • @make-it-raintx7170
    @make-it-raintx7170 4 ปีที่แล้ว

    Are this good generators? You know compared to like a Honda??

    • @mactech8975
      @mactech8975 4 ปีที่แล้ว

      most common issue i have with them is carb an people overloading.

  • @HJR78
    @HJR78 4 ปีที่แล้ว

    I have tahoe industries ti7000lxr diesel generator. It runs 10 to 20 seconds then shuts down. Voltage is 10 volts or so low. Runs fine until flip breaker with no load. Replaced capacitor with cheap on with no change. Any ideas for me.

    • @mactech8975
      @mactech8975 4 ปีที่แล้ว

      the engine shuts down when you flip the breaker?

  • @912ruckus2
    @912ruckus2 4 ปีที่แล้ว

    Thanks so much for this video. The manufacturer sent a diagram with a brush holder so I knew trouble was coming. You are the man.

    • @mactech8975
      @mactech8975 4 ปีที่แล้ว

      Glad I could help!