Complete Water Solutions
United States
เข้าร่วมเมื่อ 24 พ.ค. 2015
Complete Water Solutions Water Treatment System Installation and Repairs Complete Water Solutions provides water treatment services for industrial and commercial water treatment systems. From reverse osmosis to water softeners, to Ultraviolet filtration and cooling tower cleaning, our goal is to provide you with pure, clean water to meet your business or industrial needs. Contact Complete Water Solutions today at www.complete-water.com/ to learn more about our water treatment services nationally.
Industrial Reverse Osmosis
Industrial Carbon Filters
Industrial Iron Filters
Industrial Water Softeners
Need A GE or Osmonics RO Manual - osmonicsrosystem.com/
Industrial Reverse Osmosis
Industrial Carbon Filters
Industrial Iron Filters
Industrial Water Softeners
Need A GE or Osmonics RO Manual - osmonicsrosystem.com/
Membrane Cleaning Pro - Professional Membrane Cleaning
Membrane Cleaning Pro - Your Offsite RO Membrane Cleaning Team. Membrane Cleaning Pro can help with all your membrane cleaning needs.
www.membranecleaningpro.com
Membrane Cleaning Pro - does offer onsite services too through our parent team Complete Water Solutions.
www.membranecleaningpro.com
Membrane Cleaning Pro - does offer onsite services too through our parent team Complete Water Solutions.
มุมมอง: 152
วีดีโอ
How Reverse Osmosis (RO) Works - How Reverse Osmosis (RO) Membranes Assembled - What is RO
มุมมอง 17Kปีที่แล้ว
How Reverse Osmosis Works By Complete Water Solutions Need Help With Your RO System Contact Complete Water Solutions bit.ly/3h3a6hN In this video, we will explain how reverse osmosis works, a water purification process that removes contaminants from water by forcing it through a semipermeable membrane. What is reverse osmosis? Reverse osmosis is a process in which water is forced through a semi...
Osmonics 45CHF RO System Repairs, Membranes & Upgrade
มุมมอง 281ปีที่แล้ว
Complete Water Solutions recently upgraded this Osmonics 45CHF Reverse Osmosis System for a Manufacture In California. Both RO Systems were manufactured in the 1980's but were in great condition. A new RO system would have been twice as much money along with a 14-18 week lead time. The existing Osmonics RO Controller was obsolete and no longer functioning. Complete Water Solutions provided a dr...
Complete Water Solutions 10 Years In Business - Thank You
มุมมอง 67ปีที่แล้ว
We wanted to take a moment to thank all of our customers. We appreciate all the support and it means a lot to everyone at Complete Water Solutions and our families. Thank you for your business!
Water Softener Resin Testing - How To Know If Your Resin Is Good
มุมมอง 7Kปีที่แล้ว
Complete Water Solutions video topic today is how to pull a resin sample to send in for testing. We also discuss the reasons why you might want to test your resin. Whether you have a water softener or demineralizer (Deionization System) you may want to test your resin to see how its performing. Need Resin? Complete Water Solutions carries many types of resin from, cation, anion, select ion resi...
RO Membrane Housing End Cap Removal (Industrial Reverse Osmosis) - Complete Water Solutions
มุมมอง 6K2 ปีที่แล้ว
In This Video Nathan From Complete Water Solutions provides insight and directions on how to remove a Industrial Reverse Osmosis (RO) Housing End Cap and how to properly re-install it. - Need Parts Or Tools bit.ly/3h3a6hN Industrial Reverse Osmosis, RO Systems, Complete Water Solutions, Osmonics RO Systems, Fiberglass RO Housing, 8" RO Housing, 8" RO Fiberglass Membrane Housing, WaveCyber Housi...
How Much Salt Should My Softener Use - Salt Reduction Water Softeners
มุมมอง 7012 ปีที่แล้ว
In this video CWS takes a look at how much salt a water softener will use. Also we look at some ways to save salt and reduce chlorides. We discuss - Water Softener Brine Study - Water Softener Brine Reclaim - Salt Saving Water Softener Resin (SST-60) - Water Softener Hardness Monitors - Water Reduction - How Chlorides And Salt Affect The Environment Learn More About The Tools We Use & The Free ...
Osmonics E8-57K-ECN Upgrading RO System Controller
มุมมอง 2872 ปีที่แล้ว
In this video Complete Water Solutions upgraded an old Osmonics E8-57K RO System Controller. The old controllers were original from 1999 and consisted of the Lakewood 2450 RO Controller and Allen Bradley 1000 Micrologix Series PLC. Both of those have been obsolete for some time now. Complete Water Solutions provides a upgrade kit for the E8 Reverse Osmosis (RO) System. The upgrade kit for the O...
Osmonics Pro-100 & Pro-150 Reverse Osmosis (RO) Membrane Housing Replacement - Manuals & Drawings
มุมมอง 3653 ปีที่แล้ว
In this video we show cased replacing some Reverse Osmosis Fiberglass Housings on a Pro-100-NA and Pro-150-NA Reverse Osmosis System. The housings that were replaced were wave cyber 8" Reverse Osmosis Housings (RO Housings). The job entailed replacing (6) Housings Some of the housings were longer than others. Things to take into consideration when replacing these housings: 1.) Grooved Clamps - ...
Reverse Osmosis Troubleshooting (LT4 RO System) - Common RO Problems - RO Troubleshooting Guide
มุมมอง 1.7K3 ปีที่แล้ว
In this video we cover reverse osmosis (RO) troubleshooting centered around the LT4 Reverse Osmosis System. This new RO System has a lot of similarities to the E4 RO System. This video shows the upgraded PLC Package which allows you to really narrow down the reason your RO system may be having problems. Additional RO Troubleshooting Videos - bit.ly/3alGQiO LT4 Reverse Osmosis Manuals - bit.ly/3...
How To Install 4" (4040) Reverse Osmosis (RO) Membranes 4" / LT4 RO / E4 RO
มุมมอง 4K3 ปีที่แล้ว
In this video we walk through how to change the pre filter on the RO System and how to change the RO Membranes on a LT4 / Fiberglass RO Housing Membrane Change. Manuals for the RO Systems & Documentation is listed below. RO Membranes bit.ly/3h6WUJ5 RO Daily Log bit.ly/3DRqBHS RO Pre Filters bit.ly/3DOAFkJ RO Start Up Sheet bit.ly/2XIGBv3 LT4 RO Maintenance Manual bit.ly/3kGoSNS This video cover...
How To Change RO Membranes - Osmonics/GE E4 Reverse Osmosis (RO) - How To Install RO Membranes
มุมมอง 12K3 ปีที่แล้ว
In this video we cover how to change Reverse Osmosis (RO) Membranes in a Osmonics / GE Water E4 RO System. We cover some step by step basics and show the process. RO Daily Log Document - bit.ly/3DRqBHS RO Start Up Document - bit.ly/3jOrlWc RO Membrane - bit.ly/3h6WUJ5 Parts, Filters & More - bit.ly/2Ynfnua Osmonics / GE Water E4 Manual - bit.ly/3l3Xjx7 Other RO Membrane Change Out Video - bit.l...
What To Check On My Reverse Osmosis System (RO System) Daily Check List E4 & LT4
มุมมอง 1.1K3 ปีที่แล้ว
Complete Water Solutions covers what you should be checking daily on your Reverse Osmosis System (RO System) Things covered in this video are water testing and why it is important. If left unchecked you could damage your membranes. Also covered is changing your RO Pre Filter and why its important. FREE RO DAILY LOG SHEET - bit.ly/3DRqBHS Shopping For Supplies - bit.ly/2Ynfnua RO Pre Filters - b...
Osmonics / GE Water E4 Reverse Osmosis (RO System) Maintenance & Daily Checks
มุมมอง 1.6K3 ปีที่แล้ว
Complete Water Solutions covers what you should be checking daily on your Osmonics / GE Water E4 Reverse Osmosis System (RO System). We cover water testing, flows, pressures as well as changing of the pre filter. FREE RO DAILY LOG SHEET - bit.ly/3DRqBHS Shopping For Supplies - bit.ly/2Ynfnua RO Pre Filters - bit.ly/3DOAFkJ How Long Do Membranes Last - bit.ly/2YAMXxb What RO Cleaning Chemicals S...
Habitat For Humanity - Kenosha & Complete Water Solutions
มุมมอง 573 ปีที่แล้ว
Complete Water Solutions had an opportunity to volunteer @ Habitat For Humanity - Kenosha. We were honored to have the opportunity to work on a home for the local community. We learned a lot about Habitat For Humanity and their mission. To Learn More About Habitat For Humanity or To Donate bit.ly/3yNwFwY
Osmonics E4 Reverse Osmosis (RO) & New LT4 Reverse Osmosis (RO)
มุมมอง 3533 ปีที่แล้ว
Osmonics E4 Reverse Osmosis (RO) & New LT4 Reverse Osmosis (RO)
Happy Fathers Day - From Complete Water Solutions
มุมมอง 593 ปีที่แล้ว
Happy Fathers Day - From Complete Water Solutions
Complete Water Solutions Sea Water Reverse Osmosis (RO) Service
มุมมอง 1053 ปีที่แล้ว
Complete Water Solutions Sea Water Reverse Osmosis (RO) Service
Tonkaflo Pump Drawings & Tonkaflo Pump Manuals - Watch Before Taking Apart
มุมมอง 1.1K3 ปีที่แล้ว
Tonkaflo Pump Drawings & Tonkaflo Pump Manuals - Watch Before Taking Apart
Tonkaflo Pump Oil Maintenance & Lead Times
มุมมอง 7683 ปีที่แล้ว
Tonkaflo Pump Oil Maintenance & Lead Times
Tonkaflo Pumps Built To Order - Can I Get A Tonkaflo Pump Today?
มุมมอง 2403 ปีที่แล้ว
Tonkaflo Pumps Built To Order - Can I Get A Tonkaflo Pump Today?
Industrial Water Softener Replacement 1200 GPM Softener System
มุมมอง 2.2K3 ปีที่แล้ว
Industrial Water Softener Replacement 1200 GPM Softener System
Continuous Electronic Deionization (CEDI) - What Is Inside CEDI
มุมมอง 17K3 ปีที่แล้ว
Continuous Electronic Deionization (CEDI) - What Is Inside CEDI
Osmonics Beverage Nano Filtration (NF) 1233033
มุมมอง 1K3 ปีที่แล้ว
Osmonics Beverage Nano Filtration (NF) 1233033
Is My Softener Using To Much Salt? - Industrial Softener Review & Resin Replacement
มุมมอง 2023 ปีที่แล้ว
Is My Softener Using To Much Salt? - Industrial Softener Review & Resin Replacement
Osmonics Reverse Osmosis E8 Lakewood Controller Replacement
มุมมอง 2344 ปีที่แล้ว
Osmonics Reverse Osmosis E8 Lakewood Controller Replacement
Osmonics E8 Lakewood 2450 Controller Upgrade
มุมมอง 824 ปีที่แล้ว
Osmonics E8 Lakewood 2450 Controller Upgrade
Fleck 3150 Carbon Filter - Carbon Replacement - Carbon Re-Bed
มุมมอง 5644 ปีที่แล้ว
Fleck 3150 Carbon Filter - Carbon Replacement - Carbon Re-Bed
How Water Softener Resin Got Inside A Reverse Osmosis (RO) System Osmonics Reverse Osmosis
มุมมอง 1.2K4 ปีที่แล้ว
How Water Softener Resin Got Inside A Reverse Osmosis (RO) System Osmonics Reverse Osmosis
I hear the music but the verbal explanation???
sorry about that will see if they can lower the music. I can here it on my end - if needed we do have the CC at the bottom to follow along
Bagai mana cara keluarkkan membrane??
I’ve been looking for some reference videos for friendly education use and I am so thankful for this! Most of the more popular videos are pretty awful
Отличное объяснение! Спасибо.
Please send me Price and contact with you. Many Thanks
Price please
i have problem that,, sea water come to product line even thought HP pump running with low pressure. do you have experinced about it?
Bad seal bad membranes or control issue. Unfortunately couldn't tell you with out reviewing the system.
thanks a lot
thanks for these video. do you provide any sharing for troubleshoot?
we have a whole series for troubleshooting on youtube - th-cam.com/video/iq5GnC2y-w0/w-d-xo.html
Thanks bro.
I changed lots of RO membranes but never with a hat.
Thank you
is it safety hat ??? LOL ....
How long I need to change the resin ? 3 day ? 3 weeks ? 3 months 3 years ?
Ideally, never. However, most water softeners say that they have a life span of about 30 years, and this is mostly limited because of the resin. As long as you take proper care of your softener, you shouldn't really need to replace your resin and it can outlast more than 30 years. Taking care of it includes things like making sure it always is full of salt and that it doesn't completely run out. Make sure you wash your system every 4 months or so, and don't have a lot of iron or other solids enter Your system (you can do this by installing a water filter before your softener). However, if your softener has been mistreated and/or is older, it may be a good idea to check the quality of the resin. If it is not good, then you'll likely need to replace it.
fuck your music. junk company
answer @ :34
This is the best explanation video so far, but even there is hard to catch how water enters permeate tube
There is a slit in the permeate tube and it travels through that.
it is like a bag, a pouch. clean water diffuses into pouch and exits from the tube.
@@erdem-- a bag filter only has one inlet and one outlet. A RO Membrane has one inlet and (2) Outlets - 1 concentrate (waste) and 1 permeate (RO Water)
@@nateolszak1078 RO filte is shaped like a bag. The water diffuses into the bag. thereby It has 2 outputs. If the water did diffuse out of the bag, it would be a 1 output filter.
1-2 years is complete bs . I’ve got water that has a tds of 389 . After 5 years it’s still producing water below 20 ppm at good flow rate
Actually that's not good compared to ro manufacture specifications. You should be closer to 3 to maybe 7 tds. So unless your that range you may not be. It also depends on pretreatment and how hard you run your ro. I also mention that in the video.
I have an RO system that is not producing enough flow on the concentrate side, 1 month after changing the membranes. What could be the problem?
Could be pre treatment
That has to be the most ridiculous tool ive ever seen
It works and we have removed thousands of membranes out. When your dealing with 6 long or 7 long housings and have 20+ housings to do it makes life alot easier.
Hello sir, your insightful videos are a great resource.thank you We recently did a cip on our Ro but the membranes are not giving all water as product and no reject water.in short not working at all. We used caustic soda and citric acid for cip. What could have gone wrong. Iam Jamwel from malindi kenya. Appreciate alot
Good Evening, there could be multiple reasons. Everything from mechanical, to waiting to long to clean, to no using the right cleaners. I would visually inspect the flow meters and make sure they are operating correctly and valves are functioning properly. Then remove the end caps to identify what kind of scale or bio you might have. We have seen customers scale the membranes to the point where no flow was registering. If this happens then you will need to determine what the cause was or is. Example antiscalant was not working or softener failed. Etc.
Validation Engineer, CQV clean utilities projects. Pretty cool seeing the inside disassembled, really adds to the P&ID.
Thank you for the feed back - much appreciated.
Can tell me how can decide the flow while doing cip??
Depends on membranes, how many, the machine size, the chemicals your using and what your trying to clean. My recommendation is to look at the membrane manufacture data sheet along with the cleaners your using.
@@nateolszak1078 my plant unit have 181 vessels and each vessel have 7 membranes
Hello i hope you are well,can you give me the names of the constituent element of CEDI please
Due to legal reasons we are not able to identify manufacture.
Do you do the remanufacturing EDI ionpure?
we personally do not, we typically send to factory.
Hello! What are the lifespans of the membranes showcased when used for sea water desalination?
I want contact with you by WhatsApp
Please send me a cowboy hard hat !
Thanks Nathan, we've got a commercial system with qty 12 4"x40" membranes (3:2:2:2:1:1:1 array) that were just replaced less than a month ago but are already seeing significant flux loss and pressure drop (210 psi down to 75 psi, currently flowing ~11gpm permeate, 7 gpm concentrate after acid cleaning). Visual inspection doesn't show obvious significant debris or biomass in membrane feed spacer. Can hardness scaling cause pressure drop as well?
There are a lot of items that can cause DP and Flow issues. Organic, Bio, Scale, Silt, Temp. You may not necessarily see it when opening up the end cap. You may see it when cleaning the membrane. Using a good cleaner is a good start but also making sure the pre-treatment is proper can help.
@@nateolszak1078 thank you! Antiscalant dosing was verified to be appropriate, but the carbon tanks are not sending a shutdown signal so RO may be running during a backwash. Prefilter looks good however, and usually this gets clogged up when I've seen this issue on other systems
@jonezy6056 Water analysis, including PSA and SDI, may help you identify the issue or at least start narrowing down. Could also run into issues if the RO sits for long periods with out use.
Great video. Thanks for the information. Can we service EDI ?
EDI Systems can be services, typical services may include, stack replacement, factory rebuilds, cleaning and sanitizing
After changing the Membranes and pre filter on the E4 just as before I have very low output on water first I had 2gpm, after filter change it went to 3gpm but 2 weeks later it's down to 1 gpm We bought the unit used, but I don't know what else it could be? All my incoming pressure is good. could it be the centrifugal pump?
Could be the pump but typically you would find that right away. You could check the discharge screen of the pump. If your recovering too high you could be scaling your membranes, Also if you have no pre-treatment or are having issues with your pre-treatment you can loose output. If you have the wrong membranes you may have lower output as well. Depending on water temp.
@@completewater We have a large Carbon cartridge before water incoming.
@@Infidel67 You will need more than that most likely. Here is a blog post we did regarding "What Else Do I need With My RO" complete-water.com/blog/what-else-do-i-need-with-my-ro-system
We have packs going bad. Our pH on our water is 8.6-9.0 coming out of our RO. We've had intermittent hard water issues from our softeners switching back. My question is can the granules inside loaded with magnesium/calcium/iron/etc. be saved? I would think trying to recharge them with an acid recirculation might do the trick.
Hello, So my recommendation is to review the manual of the CEDI / EDI Stack Manufacture. They will have procedures for cleaning the Stacks. Highly recommend following it step by step as you can cause irreversible damage.
We got the GE E4, is it possible to upgrade the manual reading OP to a digital like this one?
Unfortunately there is not a "Upgrade" kit to go to a PLC version. They have actually discontinued the E4 Model and have moved over to the LT4. The RO in this video with the HMI is the upgraded version of the LT4. The basic LT4 is very similar to the E4 RO.
Great videos. I have a user request video here. Could you show us if a single 4x40 membrane under 300 psi. If it will fill a 40 gallon well pressure tank to 60 psi? I am REALLY curious! Thanks again for posting and always enjoy your videos!
Hi Rick, just based on past experience yes it can. However you need the right piping connections, and equipment. Certain design criteria should be in place for this. I have seen some systems operate this way. (Smaller commercial). I will see what we can do to cover that topic at some time this year.
@@completewater That would be awesome. I am curious if a single 4x40 at 300 PSI, such as a Grundfos feeiding into the vessel, would push water through the membrane and into a pressure bladder tank without a post permeat pump. Your videos are highly educational and are shaping the water industry in a positive manner!
So the seal on the RO membrane goes on the same side where water is entering correct?
should be
I can know the price of a small elementary cell, the production of water treated desalination per minute
Hello please email us info@complete-water.com we can provide a price and help you select the right edi
Hello, a good video, if you can make a video for us for a simple amateur-made cell, the materials constituting
Unfortunately we will not be able to disclose all the specific materials inside as most of them are protected under patent laws.
I don't know what material the 2 electrodes at the top of the plastic plate are without being electrolyzed
You might be able to reference the manual to get an idea of what side of the DC current it is
Hi thanks for the videos they are really informative, i got a question regarding this unit, is this a two stage RO system? also would it work with 1000+ ppm inlet water?
Hello, I am not sure what you mean by 2 stage. Its a 2-2-2 Array but single pass. I am not sure what you also mean by 1000+ ppm water. What is 1000 ppm = to TDS? You may have to get an analysis done to verify what is in the water. We have a free E-Book regarding what you need for your RO System. complete-water.com/blog/5-things-you-should-know-before-buying-your-next-ro-free-quick-read It will work on 1,000 TDS Water but you will want to know what is in your water to make sure you have the right pre-treatment.
I want to know how you fix anion and cation in edi. and which type of anion exchange membrane and cation exchange membrane.
Unfortunately that is confidential information. They do not share that with us.
The music is too high.
Thank you for the feed back. Some day we will get around to shooting another video with no music
Awesome
Please demonstrate…
We are working on that video for standard ro system. Written step by step procedures. The link is located in the description.
Much appreciated!
Dp 1.67 bar pressure 3.5 bar
There can be many reasons why DP is high, It can be water quality, flux ratio, organic fouling, too much waste, membranes installed wrong, water temp, lots of reasons why DP is high. The E4 and LT4 RO Systems do not have pressure gauges between stages so not sure what system you have, or how your running. You can find trouble shooting information on our website that might help you go through some things. complete-water.com/resources/reverse-osmosis-troubleshooting-guide
Veolia sir
Level 3 comes high tds Stage 1 = 15 Stage 2= 35 Stage 3= 250 Permit tds = 40
@@robinsonvarghese9119 could be water quality or bad permeate o-ring, or bad innerconnector o-ring, you could be recovering too high.
@@robinsonvarghese9119 I would potentially contact them to see if they can point you in the right direction. Unfortunately we dont have enough data to help you. We do offer field services where our technician can come out and help. If you would like to discuss a field service tech to come out you can email your request to info@complete-water.com
But stage 1 dp very high Why sir? Please discuss
probably fouling
Sir we are charged membrane
hello team complete water solutions i have one question about membrane. what is the limit of temperature to maintain our membrane good condition. if my water in almost concert by the salt at 50 per and my temperature is going around 50 degree. what they will infect in my membrane.
Hello, that depends on the membrane. Every manufacture has a limit as to temps for membranes.
Amazing proyect! I would like to know the RO feed conductivity.
Hi Ignacio it was between 800-900 Microsiemens depending on what wells they are pulling from.
@@completewater Thanks for the reply. I work at Biraden Water Solutions, also a Water Solutions company from Uruguay, and I have a very similar proyect. We are going to generate DI Water (<2 microS/cm) from 1400 microS/cm well water, with microfiltration, RO (PROflex LT4-3) and a cation resin tank and anion resin tank. We are currently waiting the RO to arrives to Uruguay from the States, so can't wait to see the plant in operation!
@@ignaciogrosso6942 That sounds like a fun project - send me some pictures once its done would like to see it info@complete-water.com
Hi sir . I have a question Ro permit pressure high problem why causes?
You have something post ro restricting the permeate flow or you have a bad high permeate pressure switch. (2 most likely causes)
@@nateolszak1078 yes sir we have 0.2 micron
Already blocked 0.2 micron because tds high raw water tds 460 .permit tds 320
Sir I think some these particles going inside. So is there any chance sir
@@robinsonvarghese9119 you might have to replace membranes, clean or check seals/orings. Typically membranes remove 97-99% of the incoming TDS. It sounds like you have a problem there.