New lighting in detached garage/barn with cupola
New wiring/conduit for three heavy repurposed pendents acquired from a Jim Beam factory. One exterior gooseneck over side door and one light in the cupola. Three switches.
มุมมอง: 81

วีดีโอ

How to fix those flickering lights
มุมมอง 70K5 ปีที่แล้ว
Got a late night service call over some flickering, dimming lights that get brighter when you turn on certain appliances. All too familiar with this issue. First thing we check is the infrared on the main breaker panel before opening the cover to see the hot spots and there will be hot spots. Our voltage readings are 243 across both hot legs which is normal. Spiking to 136 volts to ground on on...
200 Amp service entrance upgrade - Dedicated electrical space above equipment
มุมมอง 2506 ปีที่แล้ว
Switchboards, panelboards, and motor control centers must be located in dedicated spaces and protected from damage. The only exception to this rule is for control equipment that for some reason (either because of its use or other code rules) must be adjacent to or within sight of its operating machinery. There are separate code requirements for indoor and outdoor dedicated equipment space. Indo...
400 Amp underground feeder pull
มุมมอง 2.9K7 ปีที่แล้ว
Restaurant underground feeder, pulling 300 kcmil aluminum conductors in parallel for a 3 phase 120/208 volt 400 amp main breaker panel. 250' in an underground 4" PVC conduit. 1 awg grounding conductors.. We used a 12v electric winch(12,500lbs) with a deep cell battery, snatch block setup on a 10' ladder. Crimped lanyards, reel in a reel, 9/16" double braided pulling rope and lots of lube. Went ...
Residential Rough Wiring & New Service Entrance
มุมมอง 1.4K7 ปีที่แล้ว
New wiring for existing 3 floor home in Andover, MA..

ความคิดเห็น

  • @Bee-tz2hg
    @Bee-tz2hg 11 หลายเดือนก่อน

    If the issue is on the side of of the utility company are they required to fix it? I'm having the same issue in my house. All connections checked, none are loose

  • @garykarnes6514
    @garykarnes6514 ปีที่แล้ว

    Unless video .

  • @TheOmengod
    @TheOmengod ปีที่แล้ว

    I recently noticed power fluctuations in my window fan and other fans and now the lights are flickering. I seem to be getting fluctuations all over. Any thoughts? Ty.

  • @dingdongdaddy589
    @dingdongdaddy589 ปีที่แล้ว

    Hello random person. I have had flickering lights for over a year - but today I was cutting my hair with clippers and when the light dimmed, my clippers changed speed like I was on a power converter in europe. Called the electricity company today, they are sending someone out to check xformer and connections to the house. Let the fun begin. I may be back,to reabsorb… Fingers crossed.

  • @megagalactickanye454
    @megagalactickanye454 ปีที่แล้ว

    So my lights in my bedroom are flickering low once I turn OFF a heater. If I turn the heater back on the lights get brighter. Is this still the same issue?

    • @Ok-Mardy
      @Ok-Mardy 11 หลายเดือนก่อน

      Having same problem did you a find solution?

  • @12vLife
    @12vLife 2 ปีที่แล้ว

    I upgraded all my bulbs to LED a few years ago.. and all was fine. Then I upgraded my tank water heater to a big 3 line electric water heater. Everything was working fine. Then 6 months later we noticed some new LED bulbs flickering when water is heating. The old bulbs that don't flicker are Ecosmart daylight 120v 60hz 9.5w 193ma 840 Lumens non-dimmable . The new bulbs that flicker are Ecosmart 120v 60hz 9.5w 171ma 840lm non-dimmable and 120v 60hz 9.5w 150ma 800lm non-dimmable. I also tried 9w and 8w bulbs and dimmable from other brands. Everything new flickers. I'm sure my system is too big for my house and this 200 amp service. About to call an electrician and possibly downgrading my water heater. We have 3 bathrooms, 1 kitchen, 4 adult occupants.

  • @NSDaishi
    @NSDaishi 2 ปีที่แล้ว

    can't see where the black lead goes

  • @jb-ik8sj
    @jb-ik8sj 2 ปีที่แล้ว

    I have the same issue. Thanks

  • @Z-Ack
    @Z-Ack 2 ปีที่แล้ว

    Damn my high is 126.5 and low is 117.2 but phases are or always have been equal..

  • @kennethshockley1526
    @kennethshockley1526 2 ปีที่แล้ว

    It's funny that you found the problem because I've seen people with newer cars maybe 2k miles and they notice that

  • @theillestKP
    @theillestKP 2 ปีที่แล้ว

    I told her, my load fluctuates

  • @alvaro93364
    @alvaro93364 2 ปีที่แล้ว

    This is not a DIY. Don't get electrocuted. Let the professionals do it

  • @mikemike7397
    @mikemike7397 2 ปีที่แล้ว

    Thanks man.

  • @tapwater2680
    @tapwater2680 2 ปีที่แล้ว

    Oh Nosferatu!

  • @fishsquishguy1833
    @fishsquishguy1833 2 ปีที่แล้ว

    Thanks for your video! Out of nowhere: Just had lights dimming on multiple circuits when running the microwave. Thought it was the microwave going bad so unplugged it. Then while sitting in my kitchen noticed when the refrigerator compressor kicked on same thing. Noticeable dimming that would stay dimmer. Opened fridge door and the light coming on caused more dimming. Went down and checked the panel. Checked all connections at the breakers and buss with main off. All looked good and no change. Called the power co and they sent a guy out and I told him what was up and I was worried about the neutral coming in. He pulled the meter and said it looks good in the socket (my problem if bad) and then looks up at the line and noticed the neutral connection block was cocked. Said the wire fits in 2 grooves and gets clamped like that. He replaced all connections on the pole side and the weather head side and all good now. Just wanted to mention in case anybody is having a similar problem and it’ll start ruining appliances.

  • @tanker242
    @tanker242 2 ปีที่แล้ว

    Could a device that changes high an low current states within seconds or milliseconds (up and down 5-10 amp spikes from a high powered computer) cause flickering? Is that unsafe or just annoying for sensitive LED lighting due to the voltage droop?

  • @travisnelson9104
    @travisnelson9104 3 ปีที่แล้ว

    Love watching this. I work in IT and have ran brand new wire a few times as a part of my floating duty. I absolutely LOVED the more manual labor part. Pulling cables, splicing them, jacketing them, putting in racks, filling them up and patching them up is so soothing imo. I feel doing this would be similar. Some hate repetitive work, not types like us though.

  • @josephcade3541
    @josephcade3541 3 ปีที่แล้ว

    But if your neighbors are not having that problem what often goes overlooked is the minimum requirement for grounding resistance in the house which is 24 ohms. According to the Institute weights and measures and other research facilities who have done studies on the average household in America with only one grounding rod did not in any way meet the requirements of 24 ohms almost 90% of the cases 2 grounding rods had to be run 20 feet apart separated one grounding rod from the other grounding rod. This brought the grounding system well below 24 ohms. These studies were done in America Canada and Europe I have never on the public forum came across to any electricians or anyone with this knowledge. Therefore I would suggest if the lights are dimming and you're having a problem with voltage spikes run a second grounding rod 20 feet from the other. Each grounding rod must have its own 10 foot circle or cylinder of dirt which puts them twenty feet apart. There are instruments you can purchase to measure the res. In the grounding system of your house. If its to high you will have voltage spikes and dim lights (not flickering lights) when a motor turns on in the house.

    • @POLOAZTECA
      @POLOAZTECA 11 หลายเดือนก่อน

      Interesting... 🤔

  • @Scottehness
    @Scottehness 3 ปีที่แล้ว

    My current apartment has been doing this for a while. BUT not all the time. There will be periods of time where everything will dim/bright for a while. Then months of just...normal. Idk what is going on. You can see it in the whole complex I'm in too. Just glad I'm getting out of here real soon.

    • @POLOAZTECA
      @POLOAZTECA 11 หลายเดือนก่อน

      Complain with office. Save somebody's life!

  • @skunkedagain
    @skunkedagain 3 ปีที่แล้ว

    You didn’t explain anything to me

  • @oscar27ization
    @oscar27ization 3 ปีที่แล้ว

    Well it seemed like it worked with the ladder

    • @elioselectric468
      @elioselectric468 3 ปีที่แล้ว

      The setup worked beautifully, think it was a 10 footer with at least 1.25 " conduit

  • @erniefematt3328
    @erniefematt3328 3 ปีที่แล้ว

    Okay so I had flickering lights at my house and it ended up being .a bad main breaker.so that's what it was if this helps

  • @elioselectric468
    @elioselectric468 3 ปีที่แล้ว

    This was clearly an issue on the utility company side. The neutral connection was corroded causing a loose connection. If you are having flickering lights or dimming lights when running an appliance, call your local utility company to check the outside connections from the transformer. Most of the time an electrician will not be able to fix the issue and doesn't have the jurisdiction to work beyond the residence. I ask my clients to ask their neighbors if they're having similar issues, if so call the utilities. Your neighbor is sharing the same transformer as you and may be experiencing the same problems. If you watch the voltage fluctuates between 134 on the high side and 109 on the low side. These numbers are not good and usually this means there is an issue with the neutral connection. The voltage should be between 115 and 125 volts to ground, the closer to 120 the better.

    • @2jzjaymoney558
      @2jzjaymoney558 3 ปีที่แล้ว

      I'm having the same issue in my kitchen, after watching this I went and turn the washing machine off and the lights stopped flickering.

    • @elioselectric468
      @elioselectric468 3 ปีที่แล้ว

      @@2jzjaymoney558check with your neighbor and see if they are having similar issues, if so call the utilities

    • @edmalts
      @edmalts ปีที่แล้ว

      What about the electric company city ? Do they have the right to inter the house to check and problem. Do i let him in.

    • @allinthelife6094
      @allinthelife6094 10 หลายเดือนก่อน

      This is an old video but just because the issue is in the panel does not mean that the customer is out of the woods. It could be a meterbase connection which would still be the responsibility of the customer to resolve.

  • @OTT-JV
    @OTT-JV 4 ปีที่แล้ว

    Never even showed how to fix them

    • @dougfoster445
      @dougfoster445 3 ปีที่แล้ว

      He told you. Either a neutral, utility, or xfrm with 99 percent of the time being utility. Check for loose neutrals ok breakers and meter/panel. Contact your utility company if you are not an electrician

  • @RealityCalling
    @RealityCalling 4 ปีที่แล้ว

    I;m having that problem and its gotten worse. Power Co replaced the line to my house and put a monitor on the meter....Basically told me its out of their hands, as they replaced stuff outside and none of my neighbors have problems.

    • @rquintero7
      @rquintero7 3 ปีที่แล้ว

      Same here. What did you end up doing?

    • @elioselectric468
      @elioselectric468 3 ปีที่แล้ว

      Did you end up resolving the issue?

  • @assho8649
    @assho8649 4 ปีที่แล้ว

    What if all is good at the panel. What could cause

    • @jeremiegrund
      @jeremiegrund 4 ปีที่แล้ว

      As he stated in the video he checked the service entrance main circuit breaker and it was tight, a loose neutral connection at the meter or even at the pole could be causing the voltage issue seen on one of the phases. When in doubt contact your utility company and they will come to check connections. Do not attempt this yourself!

    • @elioselectric468
      @elioselectric468 4 ปีที่แล้ว

      If all is good at the house, meaning no loose or corroded connections up to the point of attachment, call the utility. Even if the utility can't find an issue, have another crew take a second look. I have had the utility say it's not them when it was them after another crew came out. Might of even been a third crew. If your sure, that's it. There's not many connections you need to check...

    • @kevinbreslin5718
      @kevinbreslin5718 4 ปีที่แล้ว

      If it was a utility problem would opening all the breakers so there is no customers equipment on the line still show a problem?

    • @MrStatic101
      @MrStatic101 3 ปีที่แล้ว

      @@elioselectric468 same issue I had the lineman tells me it was my "temporary" crimps on a full service I did. He was talking shit the whole time then he gets to the second pole and realizes the neutral on the pole is broken. Most of the lineman I've dealt with were cool. This guy was a dick. So I like how you mention getting utilities out a second time if the first one fails because sometimes you get a real winner.