![Smart Educare](/img/default-banner.jpg)
- 236
- 373 032
Smart Educare
India
เข้าร่วมเมื่อ 20 มี.ค. 2020
Over two decades of engineering experience in electrical basic design, FEED, detail engineering, commissioning and practical field exposure in Power Generation & Distribution, Utility, Oil & Gas sector, it's my pleasure to share the knowledge & experiences gained in the journey.
This channel is related to purely self-education purposes and dedicated to all the electrical engineering professionals & smart-working students who want to be successful in life & career.
This is a knowledge sharing platform to help & motivate in the respective fields of expertise.
All the contents in this channel are for information & learning purpose only. It's the individual's responsibility to check, judge or apply in any field. The owner of this channel is not responsible for any dispute, damage or mishandling arises due to improper application of the contents.
This channel is related to purely self-education purposes and dedicated to all the electrical engineering professionals & smart-working students who want to be successful in life & career.
This is a knowledge sharing platform to help & motivate in the respective fields of expertise.
All the contents in this channel are for information & learning purpose only. It's the individual's responsibility to check, judge or apply in any field. The owner of this channel is not responsible for any dispute, damage or mishandling arises due to improper application of the contents.
ETAP Load Flow II Power Factor Improvement in Power System II Low Tarif by Utility
Power factor can be improved by adding power factor correction capacitors to the power system network.
Analysis is done using ETAP software with different case studies.
Join this channel to get access to perks:
th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin
Analysis is done using ETAP software with different case studies.
Join this channel to get access to perks:
th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin
มุมมอง: 216
วีดีโอ
Harmonic Filter Sizing using ETAP II Harmonic Analysis
มุมมอง 510หลายเดือนก่อน
Harmonic Analysis is performed to check the Power Quality considering the harmonic contribution at PCC (Point of Common Coupling) by non-linear sources such as VFD, Battery & Charger, UPS etc. Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Voltage Harmonic and Current Harmonic need to be checked whether these are within the acceptable limits as spe...
Harmonic Analysis using ETAP - IEEE519 (Part-2)
มุมมอง 2032 หลายเดือนก่อน
Harmonic Analysis is performed to check the Power Quality considering the harmonic contribution at PCC (Point of Common Coupling) by non-linear sources such as VFD, Battery & Charger, UPS etc. Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Voltage Harmonic and Current Harmonic need to be checked whether these are within the acceptable limits as spe...
Harmonic Analysis using ETAP - IEEE519 (Part-1)
มุมมอง 4272 หลายเดือนก่อน
Harmonic Analysis is performed to check the Power Quality considering the harmonic contribution at PCC (Point of Common Coupling) by non-linear sources such as VFD, Battery & Charger, UPS etc. Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Voltage Harmonic and Current Harmonic need to be checked whether these are within the acceptable limits as spe...
ETAP Short Circuit Study II Device Duty & 3 Phase Fault Analysis
มุมมอง 7503 หลายเดือนก่อน
Short Circuit Device Duty is performed to choose the selectivity of power system equipment. IEC 60909 is used to perform 3-phase fault, L-G, L-L, L-L-G faults. In this video, the purpose and difference between Device Duty and IEC 60909 faults are explained with the help of ETAP simulation software. Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Sho...
ETAP Load Flow Analysis II How to Apply Load Diversity Factor
มุมมอง 9223 หลายเดือนก่อน
Load Diversity Factor needs to be applied depending on the actual absorbed load in power system network. If the rated connected loads are used to simulate Load Flow study, the actual figure of the load flow or voltage profile or equipment loading such as transformer, cable etc. can not be determined accurately. There are different ways to assign the Load Diversity Factor in ETAP. Loading catego...
IDMT Relay Settings Calculation in ETAP using IEC Formula | Relay trip co ordination
มุมมอง 8293 หลายเดือนก่อน
IEC Curves || Normal Inverse (NI) || Very Inverse (VI) || Extremely Inverse (EI) || Long Time Inverse (LTI) IDMT characteristic of protection relay can be used for electrical protection system. IDMT (Inverse Definite Minimum Time) relay characteristic came into the picture in power system protection engineering when only Time grading or Current grading for relay protection co-ordination is not ...
Electrical Conduit Installation II Conduit Embedment कैसे बनाएं ??
มุมมอง 1564 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin #conduit #embedding #conduite
PD Sequence of Operation in ETAP II Phase & Ground Fault Analysis
มุมมอง 5155 หลายเดือนก่อน
IDMT characteristic of protection relay can be used for electrical protection system. IDMT (Inverse Definite Minimum Time) relay characteristic came into the picture in power system protection engineering when only Time grading or Current grading for relay protection co-ordination is not enough. Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin This v...
Cable Sizing Calculation II Manual Calculation in MS Excel
มุมมอง 1.2K5 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Cable Sizing Calculation criteria are current carrying capacity, voltage drop & short circuit. Cable Sizing Calculation can be performed using ETAP software. Cable sizing calculation| How to select cable size| Electrical Technology and Industrial Practice How to select cable size? AC cable size & Volta...
Cable Sizing Calculation in Excel Spreadsheet
มุมมอง 1.7K5 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Cable Sizing Calculation criteria are current carrying capacity, voltage drop & short circuit. Cable Sizing Calculation can be performed using Excel spreadsheet. Cable sizing calculation| How to select cable size| Electrical Technology and Industrial Practice How to select cable size? AC cable size & V...
Capacitor Bank Sizing Calculation for Power Factor Improvement
มุมมอง 5255 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin To improve the system power factor in power system network, capacitor can be used. Analysis is done using ETAP software with different case studies. Power factor can be improved by adding power factor correction capacitors to the power system network.
Capitalization Cost Calculation of Transformer Losses
มุมมอง 2545 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin Capitalization Cost Calculation of Transformer Losses transformer impedance transformer impedance calculator typical transformer impedance ieee transformer impedance table three winding transformer impedance transformer impedance formula transformer impedance matching transformer impedance ratio iec tr...
Transformer Rating Selection explained in Excel Spreadsheet
มุมมอง 5355 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin transformer impedance transformer impedance calculator typical transformer impedance ieee transformer impedance table three winding transformer impedance transformer impedance formula transformer impedance matching transformer impedance ratio iec transformer impedance transformer impedance table transf...
Earth Grid Mat Design Calculation in Excel Spreadsheet II Practical Example
มุมมอง 4415 หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/9rzhirCF3CxM7eBEfppALA.htmljoin #earthing #grounding #ground #ieee80 #groundgrid
How to plot SC MAX MIN in TCC Curve using ETAP II Relay Protection Coordination
มุมมอง 4.5K5 หลายเดือนก่อน
How to plot SC MAX MIN in TCC Curve using ETAP II Relay Protection Coordination
Cable Tray Routing Layout II Explained with Practical Example
มุมมอง 6976 หลายเดือนก่อน
Cable Tray Routing Layout II Explained with Practical Example
Signal Communication with Remote DCS / PLC II How does DI / DO work?
มุมมอง 2196 หลายเดือนก่อน
Signal Communication with Remote DCS / PLC II How does DI / DO work?
How to restore Default Data of Components in ETAP Model
มุมมอง 3266 หลายเดือนก่อน
How to restore Default Data of Components in ETAP Model
How to model Transformer ONAN & ONAF Rating Impedance in ETAP
มุมมอง 5396 หลายเดือนก่อน
How to model Transformer ONAN & ONAF Rating Impedance in ETAP
Cable Size Selection in Power System I Cable Sizing Calculation I Short Circuit Criteria
มุมมอง 9466 หลายเดือนก่อน
Cable Size Selection in Power System I Cable Sizing Calculation I Short Circuit Criteria
ETAP Common Error during Motor Starting II Power System Analysis
มุมมอง 4646 หลายเดือนก่อน
ETAP Common Error during Motor Starting II Power System Analysis
Transformer Grounding and Vector Group using ETAP
มุมมอง 5496 หลายเดือนก่อน
Transformer Grounding and Vector Group using ETAP
Protection Coordination II Protection Stages in IDMT Relay
มุมมอง 4616 หลายเดือนก่อน
Protection Coordination II Protection Stages in IDMT Relay
Fault Contribution by Motor to Power System Network analysis using ETAP
มุมมอง 7176 หลายเดือนก่อน
Fault Contribution by Motor to Power System Network analysis using ETAP
ETAP System Study II How to Model High Voltage Circuit Breaker in ETAP
มุมมอง 1.1K7 หลายเดือนก่อน
ETAP System Study II How to Model High Voltage Circuit Breaker in ETAP
ETAP System Study II How to Model LV Molded Case Circuit Breaker
มุมมอง 5947 หลายเดือนก่อน
ETAP System Study II How to Model LV Molded Case Circuit Breaker
Impact of Power Factor in Power System Network using ETAP
มุมมอง 2767 หลายเดือนก่อน
Impact of Power Factor in Power System Network using ETAP
ETAP Power System Study II Single Line to Ground Fault Analysis
มุมมอง 1.2K7 หลายเดือนก่อน
ETAP Power System Study II Single Line to Ground Fault Analysis
ETAP System Study II How to Model Low Voltage Air Circuit Breaker
มุมมอง 9267 หลายเดือนก่อน
ETAP System Study II How to Model Low Voltage Air Circuit Breaker
Sir Nice Very Effective please make a long single line diagram and apply all funcation in same single lind dia gram
How to copy a existing TCC, say with a name "star1" and giving it a different name say "star2"?
You need to create separately once again..
Sir, how can i learn sub station design please suggest me
Substation design (220/400kV GIS/AIS) professional course may be available in the market; you can check it online..
Well Explained. Thank you!
Thanks for the feedback! Stay tuned..
Thank you for this wonderful video. Please upload a series of videos on industrial network studies, as well as the distribution networks. Thank you again for the job well done!
Thanks for the feedback! You can watch ETAP Tutorial playlist in this channel.. More videos will come..
Sir can you share the excel sheet please
Can you please share the calculation sheet. This is very helpful.
which circuit breaker are you using? mine doesn't work after after fault insertion
You can select from ETAP library... It will work definitely
Very good. Thanks 🙏🙏🙏
Thanks for the feedback!
where i can study sub station design course
Can check online platform..
Hello. I have only 1 type of door and 7 types od windows in select tab. How can I add more ?
how to use voltage regulator ?
Great video! Little advice either step more away from the mic, drink more water or try your best to please quit smacking your lips every sentence. Makes it hard to finish the video.
Thanks for the tips!
how and from where to get autocad file
You need to get it ready to import first so that it can be used in DIALUX..
Thanks
Thanks for the feedback!
How to model a 5 wdg transformer
Unfortunately, there is no provision to model 5-wndng trafo..
Can you share this excell file? Thanks before
Hi sir, Which version your using
ETAP 20.0.5
@@SmartEducare Can i get the crack version?
Can u share me excel sheet
Thanks!
Thanks for the support ❣️
Thanks for your video. Good information
Thanks for the feedback 😊
Thank you for this informative video. Sir, can you please share it?
Good one, Sir share the file please.
Great Sir, I am finding this adn you have done this. This helps me a lot. Thanks a lot
Hello Sir, thank you for sharing very informative tutorial. I am new to ETAP and I would like to learn this software. Do you provide the tutorial how to draw this SLD? Or is it possible for you to share the file so I can learn from it? Thank you Sir, really appreciate your effort.
Thanks 👍 To learn from the beginning, you can start from Load Flow study.. I have already shown there how to draw SLD and start simulation..
@@SmartEducare Thank you Sir, so just follow the sequence in your playlist, am I right Sir?
Isn't it true that if ( pick up current * ratio CT ), then the current seen by the relay will exceed CT? make CT burn.
That's why CT selection to be done properly to avoid CT saturation..
What if we provide tap in 2667 A current winding. What will happen?
Thanks sir this is really helpful. PLEASE sir how do i check the current across line 1,2,3 after running my load flow for unbalanced system.
After running Load Flow study, you have to check in the display option for all the phase currents..
Some do Dynamic motor starting study in Transient stability module? Why not in Motor starting module?
To check the system stability during any sudden change like switching on the large motor starting, generator etc. we need it.. However, dynamic motor starting is performed to check the voltage status and adequacy to start the largest motor in the power system..
Hi Sir, thanks a lot. Just wanted to ask, do we use Continuation Power Flow Method for Voltage Stability Analysis in ETAP?
Is it possible to model frequency converter in etap (50hz to 60hz)?
PLEASE SHARE EXCEL SHEETS
For dynamic motor starting, there are two models to consider: the circuit model and the characteristic model. Are both models necessary? One model sufficient? Which one provides more accuracy?
Only one method to be adopted based on the data availability from the manufacturer.. If sufficient data is available, any of the two methods will provide correct results..
How do you identify it is HV-HS-HT or HV-HS-LT or HV-LS-HT or HV-LS-LT from the motor data sheet?
Hola amigo, ¿me podrías enviar los datos del CB29 y del CB-LV2-IC1 su estudio de coordinación? Graciasss
Sir can you send all spreadsheet
what would be the best option for me to maintain coordination of my protection devices and prevent them from tripping due to fault current contribution from down stream loads. would using a three cycle protection device be ok since fault contribution will only be there for half cycle. or zone selective interlocking of the protection devices. thanks
Please make how to set harmonic of transformator and how to identify based on its spesification
Please make a video on ETAP for interview perspective
DUDE YOU THE MAN!
Thank you for the detailed explanation. Please share the excel sheet.
can anyone help me because i also cant see report manager. i try to choose viewer or pdf format but the result its not showing.
I am trying to build an excel sheet to size battery per IEEE 485. I would appreciate if you can share your files. I will use them to validate your calculation and provide you feedback.
Hi Can you please share Excel sheet.
can ushare the link for download file project?
if i will take all this time . i will use excel sheet to save my time
I have 2 configurations, SC max configuration and SC min configuration in the OLV (one line diagram), Can I display the SC max clipping current and SC min clipping current from separate configurations, or is it only possible to show both maximum and minimum currents within a single configuration?
MAX and MIN SC values will be considered in TCC plot automatically once you Run/Update SC. These values are plotted based on the c-factors selected during MAX & MIN study scenario..
Hi Sir Your tutorials are really well explained and very useful. Keep up the good work.
Thank you for the feedback!