The Electrical Solutions Channel
The Electrical Solutions Channel
  • 8
  • 70 299
LEAD ACID BATTERY SIZING Part 2
LEAD ACID BATTERY SIZING Part 2
มุมมอง: 1 105

วีดีโอ

LEAD ACID BATTERY SIZING Part1
มุมมอง 2Kปีที่แล้ว
Lead Acid Battery Sizing as per IEEE- 485 Link for Battery Load Cycle: th-cam.com/video/y8Esj0Ics_g/w-d-xo.html
BATTERY LOAD CYCLE PROFILE
มุมมอง 2.6Kปีที่แล้ว
How to estimate Battery Load Profile
HOW TO SIZE A NER
มุมมอง 1.6K2 ปีที่แล้ว
Neutral Earthing Resister Sizing
ELECTRICAL BUSBAR SIZING
มุมมอง 14K2 ปีที่แล้ว
An electrical bus bar is defined as a conductor or a group of conductor used for collecting electric power from the incoming feeders and distributing them to the outgoing feeders. Busbars are generally made of Copper or Aluminium. An undersized busbar will result in excessive heating of the busbar under normal operating condition, leading to rise of temperature beyond permissible limits. While,...
HOW TO SIZE A CABLE !
มุมมอง 3.8K4 ปีที่แล้ว
An electrical cable is an assembly of one or more wires running side by side or bundled, which is used to carry electric current. Cables are used to connect two or more electrical devices, thus allowing transfer of electricity from one device to the other. Why is it important to size a cable correctly? If the cable is undersized it will be inadequate to carry the rated load current, resulting i...
HOW TO SIZE A TRANSFORMER !
มุมมอง 33K4 ปีที่แล้ว
Electrical transformers are used in everyday life. A transformer is a passive electrical device that is used to increase the voltage level at the power generating station (Step up) or to decrease the voltage level (Step down) for Electrical power distribution purpose. Transformer sizing is a very important step and we must make informed decisions regarding proper transformer sizing and its impa...
UNDERSTANDING ELECTRICAL LOAD SCHEDULE
มุมมอง 12K4 ปีที่แล้ว
The electrical load schedule is an estimate of the instantaneous electrical loads operating in a facility, in terms of active, reactive and apparent power (measured in kW, kVAR and kVA respectively). The load schedule is usually categorized by switchboard or occasionally by sub-facility / area. This video explains in detail the steps to be followed for the calculating the Electrical load schedu...

ความคิดเห็น

  • @wesleygnanaraj8229
    @wesleygnanaraj8229 หลายเดือนก่อน

    Nice

  • @rajasekaranramakrishanan5148
    @rajasekaranramakrishanan5148 หลายเดือนก่อน

    11:58 @ Base MVA how to calculate 1 MVA

  • @uzzalchakma9783
    @uzzalchakma9783 หลายเดือนก่อน

    Sir, would you share your contact address like linkedin ID, please?

  • @ameeraadmi-td5qw
    @ameeraadmi-td5qw 3 หลายเดือนก่อน

    L2 has time .2 sec but put it behind L3 why.

  • @Khan_asif17
    @Khan_asif17 3 หลายเดือนก่อน

    Brilliant

  • @MrPcwortex
    @MrPcwortex 4 หลายเดือนก่อน

    Great video. I'm trying to find information about the minimum distance between copper bars with different potentials depending on voltage. Maybe you know where I can find this information?

  • @vinaykumarmaurya6288
    @vinaykumarmaurya6288 4 หลายเดือนก่อน

    Sir please please please please upload more videos

  • @user-ju6mw5xh5l
    @user-ju6mw5xh5l 5 หลายเดือนก่อน

    Amazingly explained Sir

  • @ganesha_pandiyan247
    @ganesha_pandiyan247 6 หลายเดือนก่อน

    Hello Sir, is this busbar calculation applicable for HV traction battery's Cell to cell and module to module busbars??

  • @adityashaw2228
    @adityashaw2228 6 หลายเดือนก่อน

    Great video

  • @RaoBonala
    @RaoBonala 6 หลายเดือนก่อน

    Battery sizing is direct summation of all load profiles? I saw some negative numbers for some load profiles. Why?

    • @ameeraadmi-td5qw
      @ameeraadmi-td5qw 3 หลายเดือนก่อน

      L2 has time .2 sec but put it behind L3 why. please reply. the channel owner will not reply.

  • @romeosecretaria6968
    @romeosecretaria6968 6 หลายเดือนก่อน

    Nice discussion & explanation..thanks

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm 8 หลายเดือนก่อน

    Superb Explanation ❤ any one can understand if he give some time to watch carefully ❤

  • @Radioman.
    @Radioman. 8 หลายเดือนก่อน

    This is a wonderful video with the best, most clear description of system design. This was a treat to watch. Thank you for sharing your expertise.

  • @user-cp4yd2ye3m
    @user-cp4yd2ye3m 9 หลายเดือนก่อน

    Very precious video. I was hoping to see a summary at the end of this video and other videos.

  • @hotpan_stories_
    @hotpan_stories_ 10 หลายเดือนก่อน

    What values you have taken to calculate ZT?

  • @mohammadahmadi895
    @mohammadahmadi895 10 หลายเดือนก่อน

    Great Thank you

  • @aatirehrarsiddiqui8894
    @aatirehrarsiddiqui8894 10 หลายเดือนก่อน

    Excellent video.

  • @MagnificentVillain
    @MagnificentVillain 11 หลายเดือนก่อน

    Very detailed and informative video of transformer sizing. It is going straight to my favorites. Please keep making more such informative videos.

  • @ClaudinneV
    @ClaudinneV 11 หลายเดือนก่อน

    If ZL = Base Load Imp / Base Impedance = 0.0886/0.16 = 0.55375 p.u.. why did you obtain 0.54367 p.u ???

  • @subhu7451
    @subhu7451 11 หลายเดือนก่อน

    Sir your content is very helpful 🙏🏻 pls make a video on selection of earthing 🙏

  • @miaoyu9702
    @miaoyu9702 ปีที่แล้ว

    GREAT

  • @Eren-vz5vb
    @Eren-vz5vb ปีที่แล้ว

    Next step is to design a transformer for 362.76 KVA and get energized from the utility am i right?

  • @jhontejada5773
    @jhontejada5773 ปีที่แล้ว

    Good day, many times I played this video and make research on standards, i did it bec. It's quite interesting and with clear steps of calculation just to say we can depend on!!!.so far I have doubt about the 15% voltage drop at high motor terminal. Applicable fire pump..can you please help to clarify...thank you

  • @jhontejada5773
    @jhontejada5773 ปีที่แล้ว

    Very intelligent ; i cannot see this approach in my prevuous studies all things is new for me...good job man!!!

  • @jhontejada5773
    @jhontejada5773 ปีที่แล้ว

    Nice, but i get lost in per unit application formula, can you share per unit fomulas, thanks

    • @jhontejada5773
      @jhontejada5773 ปีที่แล้ว

      Still we will apply 6 tines starting if large motor under vfd controls?

  • @nagarajans8988
    @nagarajans8988 ปีที่แล้ว

    Make EARTHING video

  • @nagarajans8988
    @nagarajans8988 ปีที่แล้ว

    Good job great ,thank you for the teach cable types topic make one video

  • @tamjidkabir1543
    @tamjidkabir1543 ปีที่แล้ว

    I have watched all the tutorials in your channel. Great contribution to the engineering community. Highly appreciated...❤❤

  • @Fact-fusion86
    @Fact-fusion86 ปีที่แล้ว

    Your all video is very valuable to electrical Engineer specially working in oil &gas, power, metal industry etc. Please upload the video for switchgear sizing, earthing and lightning calculation, EDG sizing etc

  • @tamjidkabir1543
    @tamjidkabir1543 ปีที่แล้ว

    This is so good! Thank you sir.

  • @tamjidkabir1543
    @tamjidkabir1543 ปีที่แล้ว

    Very good one...thank you sir

  • @tamjidkabir1543
    @tamjidkabir1543 ปีที่แล้ว

    This is so nice and helpful. Great effort sir.

  • @bhushanshinde3048
    @bhushanshinde3048 ปีที่แล้ว

    Do upload more design related videos about motors /cable tray/Ups selection and sizing as well,great explaination

  • @bhushanshinde3048
    @bhushanshinde3048 ปีที่แล้ว

    Excellent 👍

  • @bhushanshinde3048
    @bhushanshinde3048 ปีที่แล้ว

    Accurately explained sir thank you

  • @karthikeyanp6660
    @karthikeyanp6660 ปีที่แล้ว

    Please post a video for how size a breaker/switchgear

  • @bugsblrb1
    @bugsblrb1 ปีที่แล้ว

    Too good sir kindly make a video on earthing calculation for plant

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    Thanks for your efforts for this valuable content.. Also is there anything left after the battery sizing is done like calculating charger capacity, ups sizing etc..

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    Great informative content.. Waiting for part 2..

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    A very clear explanation, many many thanks for your efforts and concepts. Could you please explain how to size a Battery bank based on this battery load profile.. Also sizing of an Emergency Diesel generator. Also what are the protection systems used for transformer protection and busbar protection..

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends. Videos on the above topics are under preparation and will be uploaded shortly.

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    Crystal Clear explanation, very happy for your concepts.. Could you please explain how to size a Battery bank based on the battery load profile.. Also sizing of an Emergency Diesel generator. What are the protection systems involved at the transformer protection..

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks for your comments. Glad that you found the video useful. Videos on the above topics are under preparation and will be uploaded shortly.

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    Clear explanation, very happy for your concepts.. Could you please explain how to size a Battery bank based on this battery load profile.. Also sizing of an Emergency Diesel generator.

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends. Videos on the above topics are under preparation and will be uploaded shortly.

  • @socialedukation4511
    @socialedukation4511 ปีที่แล้ว

    You are video is simple supper..but in continuation to this if you would have done sn example. With many loads ..it is simple super

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    I have doubt on how you calculated the final impedance, since both the impedances are parallel, the formulae must be Z1*Z2 by Z1+Z2 na.. Remaining everything is crystal clear for me.. Thanks for your efforts..

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks for comments. I have checked the sum of parallel impedance Z2 = ZM II ZL, and it has been correctly calculated as Z1*Z2 by Z1+Z2 Z2 = 1.57833*0.54367/ (1.57833+ 0.54367) = 0.40438 p.u

  • @rizalinotormis5447
    @rizalinotormis5447 ปีที่แล้ว

    i think coeffecient k1 is mistakenly calculated. if e=10mm and a=120mm then e/a=0.0833, therefore, k1 should be 1.76 or 1.8?

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Yes, you are correct. The value of e/a has been erroneously calculated as 0.12 instead 0.08. Hence value of K1 will have to be changed accordingly. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    Thanks for your valuable efforts and quality content for educating us.. We expect more such content from you in future..

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends.

  • @nareshdadi1441
    @nareshdadi1441 ปีที่แล้ว

    I really enjoyed the video.. Thank you for valuable information..

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks. Glad that you found the video useful. Please let me know your comments on my other videos. Please do subscribe to my channel and share with your friends.

  • @farhanakram4223
    @farhanakram4223 ปีที่แล้ว

    Sir how can we find the absorbed power and how did you write active power of 185kW rating to 168.4kW.

    • @theelectricalsolutionschan1095
      @theelectricalsolutionschan1095 ปีที่แล้ว

      Thanks for your comment. Absorbed power is the expected power drawn by the load. Most loads do not operate at their rated capacity, but at a lower point. Absorbed Power is calculated as below: P = η·√3·V·I·cosφ where P is absorbed power in watts η is motor efficiency V is applied voltage I is absorbed current in amps cosφ is the power factor

    • @farhanakram4223
      @farhanakram4223 ปีที่แล้ว

      ​@@theelectricalsolutionschan1095 really appreciate your efforts Sir❤

  • @shavaizkhan8165
    @shavaizkhan8165 ปีที่แล้ว

    Great Effort, Please continue making these awesome videos