New Year, New Coil - Gas Package unit Evaporator Coil replacement start to finish
On this one, Casey and I were out to replace an evaporator coil on this ground , Day and Night gas package unit. House is being sold and the AC was found non op… Enioy the show as I break down how I install these slab type coils. Thanks for watchin another one! 😎🤙🏽
#hvac #heat #repair #service #diagnostic #troubleshooting #acrepair #acservice #gas #heating #evaporator #ac #carrier #bluecollar #brazing #elecrical #heatingandcooling #training #fieldpiece #hvactraining #hvacsystems #hvacexperts #hvactools #hvaclife
มุมมอง: 531

วีดีโอ

No Heat - Full Diagnostic on 2 Stage Gas Valve
มุมมอง 6K21 วันที่ผ่านมา
Tag along on this one as I get a call for no heat on a newer install. Full diagnostic on 2 stage gas valve including how I preform the repair and adjustments. Thanks for watchin! #hvac #heat #service #diagnostic #gas #servicetechnician #acrepair #acservice #hvacservice #hvacmaintenance #hvactraining #hvaccontractor #heatingandcooling #heatingrepair #heating #repair #diagnostic #troubleshooting
No Heat service call - Gas Furnace nearly catches fire! Full Diagnostic
มุมมอง 8K2 หลายเดือนก่อน
On this one I end up running into a scary situation…. On one of the first no heat diagnostic calls of the season in the fall, I run into a safety issue with this gas furnace. Tag along as I dive into a full diagnostic to figure out what’s goin on! Thanks for watchin another one! 😎🤙🏽Happy halloween! 🕷️🕸️🔥 #acservice #hvac #servicetechnician #ac #acrepair #airconditioning #heatingandcooling #hvac...
Evaporator Coil retrofit - Start to finish installation inside garage
มุมมอง 3.3K3 หลายเดือนก่อน
Tag along as I install a new coil inside a garage. The original coil is obsolete so I had to find a way to get it to work for an elderly client in the middle of a heat wave. Thanks for watching this start to finish installation! #hvac #ac #acrepair #acservice #airconditioning #heatingandcooling #hvaccontrols #servicetechnician #compressor #fieldpiece #hvacarmy #hvacmaintenance #evaporator #evap...
Carrier Inverter Service Call - New install with major issues!
มุมมอง 1.6K3 หลายเดือนก่อน
On this service call I arrived to find an error code on this Carrier inverter - worked my way through the call and left some recommendations to get this new install right. Enjoy the video! Thanks for watchin #hvac #ac #acrepair #acservice #airconditioning #carrier #heatingandcooling #hvaccontrols #inverter #servicetechnician #servicetech #airhandler #newconstruction #fails #waterleakage #hvacli...
Inducer Motor running during cooling mode!! - Troubleshooting Gas package unit circuits
มุมมอง 1.5K3 หลายเดือนก่อน
On this one I’m taking you guys on a service call I got because I just so happened to be in the area and was dispatched to take a second look at this unit. Another technician advised tech support said to “bypass” a limit until the new one arrived.. enjoy! And thank you for watchin! 🤙🏽 #hvac #heatingandcooling #ac #acrepair #acservice #airconditioning #compressor #copeland #amana #goodman #hvacc...
Compressor and TXV replacement - unit less than 10 years old… this was preventable! #hvac
มุมมอง 2.3K4 หลายเดือนก่อน
Installation of a new compressor , txv and filter drier relocation. This unit had equalized pressures on a previous visit… Approved to install new compressor and valve here is a video of the process I used for the repair. Hope you enjoy the longer video sit back and relax! #hvac #hvacparts #hvactraining #heatingandcooling #hvaccontrols #copeland #compressor #txv #hvactools #hvaclife #airconditi...
Condenser Fan Motor Replacement - Quick tricks for a nice smooth repair..
มุมมอง 1.7K6 หลายเดือนก่อน
Condenser Fan Motor Replacement - Quick tricks for a nice smooth repair..
Contactors burnin up! - Add this to your Transformers
มุมมอง 1.6K6 หลายเดือนก่อน
Been having a ton of contactor replacements these past 2 years. Here’s a quick video on replacing one and adding a transformer with a tip on preventing more from burning up! Enjoy #hvac #fieldpiece #heatingandcooling #hvaccontractor #hvacexperts #hvacmaintenance #hvacparts #hvacrepair #hvactools
Evap Coil change out Start to Finish - Aluminum ADP Coil leaks at 2 years in - #HVAC
มุมมอง 9637 หลายเดือนก่อน
On this one I had to replace a 2 year old ADP evap coil due to a leak. Found leak at the U-Bend aluminum braze where the copper meets. I could easily fix this repair but the company honored a full warranty. Enjoy this start to finish video. Thank you! #hvac #hvacmaintenance #hvacparts #hvactraining #hvacsystems #hvacexperts #hvacschool #heatingandcooling #adp #evaporator #refrigeration #hvacrep...
Aqua Chill - Residential water cooled condensing unit.. What could go wrong?!?
มุมมอง 1.1K8 หลายเดือนก่อน
Aqua Chill - Residential water cooled condensing unit.. What could go wrong?!?
Bryant Package Unit INFESTED!! Something was living in here..
มุมมอง 7749 หลายเดือนก่อน
Bryant Package Unit INFESTED!! Something was living in here..
New Heat Exchanger Installed 🔥Teardown and Rebuild 🔥 Last one of the season!
มุมมอง 3879 หลายเดือนก่อน
New Heat Exchanger Installed 🔥Teardown and Rebuild 🔥 Last one of the season!
Heat Exchanger Replacement - Huge Crack Trips Rollout Switch - Owners Saved!
มุมมอง 64110 หลายเดือนก่อน
Heat Exchanger Replacement - Huge Crack Trips Rollout Switch - Owners Saved!
Propane Kit installed on Natural Gas Furnace! #hvac #hvactraining #heat #trane #repair
มุมมอง 32811 หลายเดือนก่อน
Propane Kit installed on Natural Gas Furnace! #hvac #hvactraining #heat #trane #repair
Honeywell HZ322 Zone Board Installation - Replacing single stage controls with 2 stage
มุมมอง 7K11 หลายเดือนก่อน
Honeywell HZ322 Zone Board Installation - Replacing single stage controls with 2 stage
Hardstart Kit blew up!!! Duel Fuel Trane package unit
มุมมอง 1.1K11 หลายเดือนก่อน
Hardstart Kit blew up!!! Duel Fuel Trane package unit
Mitsubishi City Multi Rebuild Due to catastrophic failure!
มุมมอง 31211 หลายเดือนก่อน
Mitsubishi City Multi Rebuild Due to catastrophic failure!
ComfortAire mini split by MARS - Failed compressor discharge temp sensor! I MADE A MISTAKE
มุมมอง 681ปีที่แล้ว
ComfortAire mini split by MARS - Failed compressor discharge temp sensor! I MADE A MISTAKE

ความคิดเห็น

  • @АлексейСорокин-у3с
    @АлексейСорокин-у3с 3 วันที่ผ่านมา

    I'm learning from your video. I'll go wash the motor. The customer will be grateful to me

  • @sanmansfishingadventure
    @sanmansfishingadventure 4 วันที่ผ่านมา

    Too easy!

    • @ServiceTechSonny
      @ServiceTechSonny 4 วันที่ผ่านมา

      Appreciate you watchin! 😎🤙🏽

    • @kp-lf3jr
      @kp-lf3jr 4 วันที่ผ่านมา

      @@ServiceTechSonny where are you located?

    • @ServiceTechSonny
      @ServiceTechSonny 4 วันที่ผ่านมา

      @ I’m up in NorCal

  • @hectoro9584
    @hectoro9584 4 วันที่ผ่านมา

    Nice work!

    • @ServiceTechSonny
      @ServiceTechSonny 4 วันที่ผ่านมา

      Thanks Hector! 😎🤙🏽

  • @MisfitsRugby9
    @MisfitsRugby9 12 วันที่ผ่านมา

    You need to get the Jumper King my friend so you don’t have to go up and down the roof to get the thermostat on a call. Rodger’s Supply has them for less than $71 12/19/24

  • @x3Myst3ry
    @x3Myst3ry 13 วันที่ผ่านมา

    Hello, I know this video is a bit older but I’m having issues with my Honeywell HZ322 zone board. Would you happen to know what it means when “Zone 1 and Zone 2” are illuminated red but Zone 3 is green but then all of a sudden they are all green? And a short while later Zone 1 and Zone 2 go red again. I’m also having issues with my very top floor blowing air like crazy when the thermostat isn’t even on. I have three floors. The top floor will blow air if my middle or first floor thermostats are on. I think this is something to do with the control board being all messed up or the dampers. My compressor was recently changed. I have an electric furnace and a heat pump outdoor system.

    • @cvinci1
      @cvinci1 7 วันที่ผ่านมา

      Sounds like an issue with the damper for your 3rd zone - possibly it was wired incorrectly? Start by comparing the damper wiring for the upstairs zone to the other two and see if there is any obvious difference. If the damper uses 3 wires you can try swapping M4 & M6 on the upstairs zone. Is it always blowing when another zone is calling, or is it blowing during the purge cycle at the end of a call from another zone? The former is likely a mis-wired damper and the latter can be configured with the PURGE DAMPERS setting set to [UNCHANGED] in the HZ322 advanced settings.

    • @x3Myst3ry
      @x3Myst3ry 7 วันที่ผ่านมา

      ⁠@@cvinci1thank you for your response. I will try and figure this out when I can get into my attic again. I never messed with the wiring of the dampers at all up in the attic or settings, which confuses me. Only wiring of the thermostat of the Zone 2 I believe if it is labeled correctly.

    • @cvinci1
      @cvinci1 6 วันที่ผ่านมา

      @@x3Myst3ry Good luck. It's also possible that the zone damper motor for the upstairs zone is dead so the damper is stuck in the open position. If you can access the damper motor, you can inspect visually and manually close it temporarily while you sort out the problem. If you're not sure what you are doing, a competent HVAC tech can probably get you sorted pretty quickly.

    • @x3Myst3ry
      @x3Myst3ry 6 วันที่ผ่านมา

      @@cvinci1 I was thinking it could be dead as well. Could this cause AUX heat to kick on by chance? For example.. I’ve had my temp set at 68 and inside heat is 66 but AUX heat kicks on when outdoor temp is between 40-50s. Which is definitely not normal. Especially when I’m calling for only 2 degrees higher.

  • @gioskywalker2581
    @gioskywalker2581 17 วันที่ผ่านมา

    Good job cleaning that stuff out bro freakin Stuart little strikes again, I can only imagine the stench as soon as you popped your head in that attic

  • @Snowlys
    @Snowlys 18 วันที่ผ่านมา

    Do you wear the respirator in every attic?

  • @rightconditions2010
    @rightconditions2010 22 วันที่ผ่านมา

    What type of lighting are using here? It looks great.

  • @LeoLoder
    @LeoLoder 22 วันที่ผ่านมา

    Great video. The only thing I would add is when tightening the inlet side of the gas valve I noticed you used the " square" part of the valve to tighten. Always try to use a nipple in that part of the valve because you could possibly distort the threads. Keep up the good work!

  • @FSAUDIOGUY
    @FSAUDIOGUY 23 วันที่ผ่านมา

    Good Tune Up Man! Thanks for sharing....subbed! Stay Well!

  • @phillipjoy1305
    @phillipjoy1305 23 วันที่ผ่านมา

    Good video 😊

  • @JonahOlfus
    @JonahOlfus 23 วันที่ผ่านมา

    Solid video I’m sure we all appreciate this free game especially me coming up cus you DONT have to do this!💯

  • @waderosteet183
    @waderosteet183 24 วันที่ผ่านมา

    Great videos

  • @steviegas4352
    @steviegas4352 24 วันที่ผ่านมา

    Baddass thanks man for the 2 stage jump

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      Appreciate you watchin Stevie 😎🤙🏽

  • @polishsharpshooter2876
    @polishsharpshooter2876 24 วันที่ผ่านมา

    I’ve seen a large amount of these failing. Usually you can rap it sharply with a screwdriver handle and it will work again. Problem is it might work normally for a year or a week. The replacements are no better. Just junk valves.

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      I agree man ! Stuff isn’t made like it used to be. -.- we just replaced it under a full warranty to keep the client happy. Thanks for watchin 👊🏽😎

  • @joemartinez-673
    @joemartinez-673 24 วันที่ผ่านมา

    THANKS 😎 🤟

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      Thanks for watchin Joe! 😎

  • @ELITECLIMATESOLUTIONS
    @ELITECLIMATESOLUTIONS 24 วันที่ผ่านมา

    Nice work brother!!

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      Appreciate it! Thank you 👊🏽😎

  • @Ogtonyg
    @Ogtonyg 24 วันที่ผ่านมา

    I usually like to plug my gas valve into a contactor to know for sure that the board is working right (i've had my meter read 28 volts but it was phantom voltage) i guess theres no way to do that with these plugs? 🤔

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      That a good one Tony! Yea with the 2 stage you can run 24 to the valve but you gotta make sure it makes good contact on the valve . On a single stage valve it’s super easy to bypass and run C and R to the valve to test with some wires and spade connectors 😎

  • @AndresH92
    @AndresH92 24 วันที่ผ่านมา

    Why are you wearing a respirator? I've seen other people use them. Should I be wearing one in the attic?

    • @Jason-wc3fh
      @Jason-wc3fh 24 วันที่ผ่านมา

      Yes. Particularly if the insulation is visible and the fibers are being disturbed by your movement when working in there.

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      Exactly what Jason said in the attics with insulation blown everywhere. Trying to last as long as I can and stay healthy in the trade

    • @jacojanks5985
      @jacojanks5985 24 วันที่ผ่านมา

      Must be from California. Everything causes cancer even breathing you own breath. Probably eats McDonalds for lunch.

  • @avinashdesai0206
    @avinashdesai0206 24 วันที่ผ่านมา

    Pressure Switch

  • @Jon-hx7pe
    @Jon-hx7pe 24 วันที่ผ่านมา

    These could easily be used as training videos.

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      I appreciate that Jon! Helpin with some tips for the next generation 😎🤙🏽 thanks for watchin!

  • @repairitdontwreckit4257
    @repairitdontwreckit4257 24 วันที่ผ่านมา

    I liked the video. Looked like the install location and access wasn’t to bad.

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      Not bad at all! I’m in NorCal where abt 75% of the units are horizontal in the attics unfortunately

    • @repairitdontwreckit4257
      @repairitdontwreckit4257 24 วันที่ผ่านมา

      @@ServiceTechSonny I am in Arizona. Our air handler is in the attic also and in the horizontal position. However, I did create an area where you had some space to work and access to the unit comfortably . I’ve watched a few videos where it’s an absolute nightmare trying to get into a comfortable position to do some work. I don’t know why when our house was built a proper access to the unit was not created. Did the builders think these things would never break? I guess I should have said your space to work on the unit was better than many others I have seen on utube. As a viewer of the video and not being there I’m at disadvantage. At any rate it was a great video showing your organized method of diagnostics.

    • @ServiceTechSonny
      @ServiceTechSonny 24 วันที่ผ่านมา

      @ it amazes me how little planning goes into the space around the units so be serviced. You’re right it’s like the designer or builder thinks we can set em and forget em 😂 that’s good planning on your part to make that space available! I appreciate your feedback , thanks a lot!! 👊🏽😎

  • @stevencossaboon3237
    @stevencossaboon3237 25 วันที่ผ่านมา

    Nice work.

    • @ServiceTechSonny
      @ServiceTechSonny 25 วันที่ผ่านมา

      Thanks Steven! 👊🏽😎

  • @followeroftheway5310
    @followeroftheway5310 25 วันที่ผ่านมา

    Nice video 👍🏼 thanks for showing us

    • @ServiceTechSonny
      @ServiceTechSonny 25 วันที่ผ่านมา

      Appreciate you hangin out! Thanks for watching 😎

  • @fallacywatcher
    @fallacywatcher หลายเดือนก่อน

    Nice thanks for the lesson this will help

  • @TheonlyKK0325
    @TheonlyKK0325 หลายเดือนก่อน

    Clever trick with the fuse to confuse the circuit into working! Nice

    • @ServiceTechSonny
      @ServiceTechSonny หลายเดือนก่อน

      Appreciate you man! 🤙🏽

    • @emmanuelvelasco4068
      @emmanuelvelasco4068 หลายเดือนก่อน

      Great way to find the problem, thanks for sharing

  • @jesusnunez2871
    @jesusnunez2871 หลายเดือนก่อน

    What was the reason for relocating the filter drier?

  • @MikeSmith-gi8fu
    @MikeSmith-gi8fu หลายเดือนก่อน

    Lots of roll out these days from spiders. Did 3 already.

  • @brianlundsr1489
    @brianlundsr1489 หลายเดือนก่อน

    I have an oddity. Miller M7 furnace. There is a cover that goes over the burner/manifold assembly. When the cover is in place and the t-stat calls for heat, one burner will light and then go out. If I remover the cover and the t-stat calls for heat, all three burners operate correctly and I can then replace the cover and it will continue to operate. I am wondering if I have a partial blockage at the intake on the roof??

  • @hellhound-si5oz
    @hellhound-si5oz หลายเดือนก่อน

    I wish all crawl space that have had that fluffy insulation installed had that kind of guard and a nice little pathway, kind of a nice place to actually kind of work, so I don't have to drag everything out to the Van. What fun it is. Drag a big blower out

  • @musicnerd72
    @musicnerd72 หลายเดือนก่อน

    Residential unit on the roof. You must be out west somewhere... 🤣

  • @billwatcher9321
    @billwatcher9321 หลายเดือนก่อน

    Please don't post any more videos if you don't know what your doing. Someone might follow your bad advice.

    • @musicnerd72
      @musicnerd72 หลายเดือนก่อน

      I'll get you a Kleenex.

    • @Imagashole
      @Imagashole หลายเดือนก่อน

      You’re that guy that tells em all they have a crack in the heat exchanger and need a new unit.

  • @joebanks174
    @joebanks174 2 หลายเดือนก่อน

    When you check continuity you have to isolate the switch.

    • @ChristianRodriguez-ww9jz
      @ChristianRodriguez-ww9jz หลายเดือนก่อน

      So am I understanding this correctly? when unit received signal for cooling, something intermittently shorted in the board causing high limit to close telling the inducer to come on? I’m assuming the high limit is supposed to be open when signal is not being sent for heat, correct? Or am I way off?

  • @777robocop
    @777robocop 2 หลายเดือนก่อน

    Why replace all the piping? Why not just buy a new solenoid and replace old piping? Saves you time measuring cutting and threading new pipe?

    • @ServiceTechSonny
      @ServiceTechSonny หลายเดือนก่อน

      Sorry if the video looked a little rushed due to it being a “short” . The only part which was replaced was the valve the existing manifold was reused and it all fit back together just right! No pipe work was done. The other manifold was from a different unit I harvested from after it died. Thanks for watchin!!

  • @fisherbrown903
    @fisherbrown903 2 หลายเดือนก่อน

    Yes new hvac dont last long. Like car. Too

  • @fisherbrown903
    @fisherbrown903 2 หลายเดือนก่อน

    What year and brand which state. Mines 18 years old in NJ

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      4 years old - Trane Gas Pack - Norcal , Thanks for watchin Fisher! 🤙🏽

  • @fisherbrown903
    @fisherbrown903 2 หลายเดือนก่อน

    Nice work

  • @sanmansfishingadventure
    @sanmansfishingadventure 2 หลายเดือนก่อน

    Come fix mine😂

  • @john7017
    @john7017 2 หลายเดือนก่อน

    First Attic furnace I saw wired up to an extension cord...

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      Furnace rated pig tail , welcome to the west! thanks for watchin

  • @pollydor07
    @pollydor07 2 หลายเดือนก่อน

    It’s good done a nice good job you found the culprit clogged the gas hole , checked throughly job well done . Thanks .

  • @daleborg9070
    @daleborg9070 2 หลายเดือนก่อน

    What ever was in the orifice is now in the manifold only to plug the orifice again. Why not remove the orifice and blow it out?

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      It was thoroughly cleaned on that top orifice before i reinstalled the manifold i know in the video it cut quick to the re install. i usually only remove them if they are caked up with carbonic build up and necessary. thanks for watchin!

  • @ericmentzer8846
    @ericmentzer8846 2 หลายเดือนก่อน

    Never worked on a trailer furnace did you

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      Been workin on furnaces since 08 man. this is just for fun

  • @HVAC-Wizard
    @HVAC-Wizard 2 หลายเดือนก่อน

    Great catch

  • @fisherbrown903
    @fisherbrown903 2 หลายเดือนก่อน

    nice vido , so pro

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      Thank you Fisher I appreciate you! 🤙🏽

  • @fisherbrown903
    @fisherbrown903 2 หลายเดือนก่อน

    well done

  • @LeoLoder
    @LeoLoder 2 หลายเดือนก่อน

    Roll outs are never fun.

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      Scary stuff man! Thanks for watchin Leo 🤙🏽

  • @Ogtonyg
    @Ogtonyg 2 หลายเดือนก่อน

    I hate service titan...

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      The pricing is crazy but other than that it’s not bad what’s some of your complaints about it?

  • @realSamAndrew
    @realSamAndrew 2 หลายเดือนก่อน

    That safety pin is more commonly known as a paperclip 📎

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      😅 I’m editing the video like did I really just call this paper clip a safety pin! 😫 you might get some bloopers every now and then in here haha , thanks for watching Sam 🤙🏽

    • @tabcreedence6553
      @tabcreedence6553 2 หลายเดือนก่อน

      It might be a safety clip you never know

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      @@tabcreedence6553😂😅

    • @DennisDuffy-n8g
      @DennisDuffy-n8g หลายเดือนก่อน

      So many expert criticisms 🤣🤣

  • @sanmansfishingadventure
    @sanmansfishingadventure 2 หลายเดือนก่อน

    Too easy man

    • @ServiceTechSonny
      @ServiceTechSonny 2 หลายเดือนก่อน

      Like figuring out a puzzle! Thanks for watchin bro! 🤙🏽

  • @cani6767
    @cani6767 2 หลายเดือนก่อน

    Nice