kamakina vlog
เข้าร่วมเมื่อ 6 ก.ค. 2018
#742 p2)) LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#742 p2)) LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง: 16
วีดีโอ
#741 p1)) LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง 82 ชั่วโมงที่ผ่านมา
#741 p1)) LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#740 TMP UNSTABLE, MACHINE TEST FAILED PROBLEM ON DIALYSIS MACHINE
มุมมอง 2112 ชั่วโมงที่ผ่านมา
#740 TMP UNSTABLE, MACHINE TEST FAILED PROBLEM ON DIALYSIS MACHINE
#739 HEAT DISINFECTION INTERRUPTED & LEAKING PROBLEM ON DIALYSIS MACHINE..
มุมมอง 1114 ชั่วโมงที่ผ่านมา
#739 HEAT DISINFECTION INTERRUPTED & LEAKING PROBLEM ON DIALYSIS MACHINE..
#738 /2 LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง 1916 ชั่วโมงที่ผ่านมา
#738 /2 LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#737 /1 LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง 2619 ชั่วโมงที่ผ่านมา
#737 /1 LOW FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#736 UF PUMP CAN CALIBRATE PROBLEM ON DIALYSIS MACHINE..
มุมมอง 13วันที่ผ่านมา
#736 UF PUMP CAN CALIBRATE PROBLEM ON DIALYSIS MACHINE..
#735 2) MACHINE NO POWER PROBLEM ON DIALYSIS MACHINE..
มุมมอง 30วันที่ผ่านมา
#735 2) MACHINE NO POWER PROBLEM ON DIALYSIS MACHINE..
#734 1) MACHINE NO POWER PROBLEM ON DIALYSIS MACHINE..
มุมมอง 10วันที่ผ่านมา
#734 1) MACHINE NO POWER PROBLEM ON DIALYSIS MACHINE..
#733 BLOOD PUMP PROBLEM (300) ONLY PROBLEM ON DIALYSIS MACHINE..
มุมมอง 4014 วันที่ผ่านมา
#733 BLOOD PUMP PROBLEM (300) ONLY PROBLEM ON DIALYSIS MACHINE..
#732 FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง 2614 วันที่ผ่านมา
#732 FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#731 CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
มุมมอง 5114 วันที่ผ่านมา
#731 CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
#730 2 LEAKING IN THE BACK & FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
มุมมอง 3314 วันที่ผ่านมา
#730 2 LEAKING IN THE BACK & FLOW ERROR PROBLEM ON DIALYSIS MACHINE..
#729 1 LEAKING IN THE BACK & LOW FLOW PROBLEM ON DIALYSIS MACHINE..
มุมมอง 2714 วันที่ผ่านมา
#729 1 LEAKING IN THE BACK & LOW FLOW PROBLEM ON DIALYSIS MACHINE..
#728 BLOOD LEAK & NO POWER PROBLEM ON DIALYSIS MACHINE..
มุมมอง 2621 วันที่ผ่านมา
#728 BLOOD LEAK & NO POWER PROBLEM ON DIALYSIS MACHINE..
#727 (3) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
มุมมอง 1721 วันที่ผ่านมา
#727 (3) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
#726 (2) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
มุมมอง 1421 วันที่ผ่านมา
#726 (2) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
#725 (1) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
มุมมอง 3121 วันที่ผ่านมา
#725 (1) TMP & CONDUCTIVITY PROBLEM ON DIALYSIS MACHINE..
#724 part 3) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..
มุมมอง 2721 วันที่ผ่านมา
#724 part 3) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..
#723 part 2) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..
มุมมอง 1328 วันที่ผ่านมา
#723 part 2) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..
#722 part 1) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..♒️❤️❤️❤️
มุมมอง 2228 วันที่ผ่านมา
#722 part 1) LOW FLOW ERROR & TMP LOW PROBLEM ON DIALYSIS MACHINE..♒️❤️❤️❤️
#721 FILLING PROGRAM PROBLEM ON DIALYSIS MACHINE..
มุมมอง 28หลายเดือนก่อน
#721 FILLING PROGRAM PROBLEM ON DIALYSIS MACHINE..
#720 25 VOLT PROBLEM ON DIALYSIS MACHINE..
มุมมอง 44หลายเดือนก่อน
#720 25 VOLT PROBLEM ON DIALYSIS MACHINE..
#719 p2. TMP PROBLEM ON DIALYSIS MACHINE..
มุมมอง 24หลายเดือนก่อน
#719 p2. TMP PROBLEM ON DIALYSIS MACHINE..
#718 p1. TMP PROBLEM ON DIALYSIS MACHINE..
มุมมอง 27หลายเดือนก่อน
#718 p1. TMP PROBLEM ON DIALYSIS MACHINE..
#717 FLOW ERROR & LEAKING PROBLEM ON DIALYSIS MACHINE..
มุมมอง 23หลายเดือนก่อน
#717 FLOW ERROR & LEAKING PROBLEM ON DIALYSIS MACHINE..
716 HIGH FLOW. LOW FLOW & TMP PROBLEM ON DIALYSIS MACHINE..
มุมมอง 17หลายเดือนก่อน
716 HIGH FLOW. LOW FLOW & TMP PROBLEM ON DIALYSIS MACHINE..
#715 TMP FAIL . TMP ALARM EVERY TIME DFR IS 700 PROBLEM ON DIALYSIS MACHINE..
มุมมอง 19หลายเดือนก่อน
#715 TMP FAIL . TMP ALARM EVERY TIME DFR IS 700 PROBLEM ON DIALYSIS MACHINE..
#714 LOW FLOW ERROR. TMP HIGH & LOW PROBLEM ON DIALYSIS MACHINE..
มุมมอง 19หลายเดือนก่อน
#714 LOW FLOW ERROR. TMP HIGH & LOW PROBLEM ON DIALYSIS MACHINE..
#713 LEAK PROBLEM ON DIALYSIS MACHINE..
มุมมอง 18หลายเดือนก่อน
#713 LEAK PROBLEM ON DIALYSIS MACHINE..
When do I connect the venous and artery pressure sensors?
Wish these were in English! Thanks man
Boss meron kang video calibration ng acid at bicarb pag nag PM.
@@francisbonga5936 Meron hanapin mo PM na kalagay
Nasa sa 700 video na hindi ko na alam
Good Morning sir Tanong ko lang paano eh fix Yung v100 alarm sa 1008s na machine,. Watching from BOHOL PHILIPPINES ,. BTW new subscriber nyo Ako sir 😊😎
Baka may mga tropa Jan na willing tumuro,. Comment lang kayo Dito para gawa tayo Ng GC Ng mga HD technician,. Spread the Love
@@amieroses-k3n check mo yung mga board nang machine barrow ka muna sa ibang machine na hayos try replace board one by one
@@kamakinavlog6103 okay na sana sir KASO conductivity na naman nag fail 😅😂
@@amieroses-k3n calibrate mo pressure
Nice idol
Sa aken sir flowinlet nman nhirapan ako kasi bago pa lng ako
@@raldzzz4344 kung hindi pressure transducer valve #9 o #10 valve 30, 31, 32, 34
Good Morning sir Tanong ko lang paano eh fix Yung v100 alarm sa 1008s na machine,. Watching from BOHOL PHILIPPINES ,. BTW new subscriber nyo Ako sir 😊😎
Kamakina san mo nakuha ung screw? Ano pangalan?
Sir saan bansa ka
@@raldzzz4344 NYC
San pde mag training for HD technician?
@@gpaz2439 Hindi ko alam sa pinas pero ako nagaral ako taxes pero meron din sila California
@kamakinavlog6103 texas u mean po b?
dito kc ko sa Canada po now
@@gpaz2439 kung nandito ka lang sa new York baka maipasok kitang dialysis technician
@@kamakinavlog6103 sayang sir. ty po Godbless
Galing kaba sa nephro sir
@@raldzzz4344 Hindi, fresenius ako nag aral
One time kasi sir nag 24vlts ung machine ko. Na reset ko nman lht ganun paren
@@kamakinavlog6103jaan po ba sa america
@ check mo mother board. Power logic board. Actuator board . Sensor board or blood pump module
Oo. Kailangan ba I lock ba yun sir
Idol saan bansa ka freesinius
Repalce balance chamber...
hello i have a issue with a 2008t machine, i replaced acid pump because it wouldnt come up in conductivity it stays at 10.0, old pump i replaced brushes and it wouldnt come up either thats why i went ahead replaced with a new one but still not coming up. any suggestion
@@kevinmunoz3389 Okay. Check valve 10 or 9 pressure transducer. If still Check valve 31. 33. 34. Or 32 one by one run dialysis mode
Brother I wish I spoke Tagalog. I can follow along but I’m loosing a lot because I don’t understand. Can you post some vids in English. Much love. Salamat for the vids.
Again Thank You, learning so much from you.
You welcome bro..❤
hi sir i have a question po... ano po ang problem pag may alarm na balancing errorÉ fresenius 5008s po na machine... salamat po
@@resshin9791 hindi ko kabisado 5008s pahingi ng diagram nang machine
@@kamakinavlog6103 ay wala po ako diagram.. pro okay lang po.. kasi nung isang araw ng alarm lang po siya ng balancing erron tas nag confirm lang ako then nde na po naulit...ehe
I am more appreciative if you can really depend on your buddy. Knowing what there doing, being meticuloso on handling repairs.
Goodeve sir paano poba masolve ung watchdog error
Boss tanung kulang ung pressure gauge mu n ginagamit mu sa flow at doration anung tawag s gauge nya. .
Sa guage Nyan at ilan ung psi Nyan .
Morning how are You . When the patient have cramp what can be the problem
@@FfFf-q9t6e high potassium or they taking a lot of water from the patient.
😂😂 u don't Speak English can I get ur content ??
I have problem one conductivity after 2 hours of dialysis the conductivity will go up later low again
@@olatunjibabsz5311 no flow error?
@@olatunjibabsz5311 if no , check your acid or bicarb pump , check your Conductivity cell or Post Conductivity cell
😂 you don't Speak English at all? And yours video can not be subtitles 😢
@@olatunjibabsz5311 share my video
Check your air separator. Flow regulator & Dearation relief valve calibration pressure..
Kamakina may error ka ng "10 fill program 1 hr?"
Why can't u speak English and your video can not . Subtitle😢
sir ano ba posible na sira kapag flow recirc error during heat disinfection nacalibrate ko na deaeration tas napalitan ko na rin valve 29
@@michaellajera4997 check mo valve 29. 39. 26. 24. At 25
Valve 30 pala check mo din
How does switching affect conductivity? I don't quite understand
Kuya magtatanong lang po. Ano po yung papalitan na parts pag filling program pag nakasalang lang po si patient lumalabas yung alarm. Salamat po
@@karenjavier6059 air separator kahit yung top lang pwede na
Sr un ba filter sa likod un diasafe?
Ano po ba yung air separator san po ba makikita yun..? Salamat po
@ yes
2 months kame mag palit nang diasafe
Salamat. Big help ung uploads mo
what is solution of no conductivity?
@@NotgamerGOD5781 No Conductivity? It depends what parts of the machine, could be airlock. Acid or bicarb pump. Pressure transducer or valve
What did you fix/replace. Cant hear what your saying
Panu ba e calibrate ang launch atf exchanger? Weighing scale not accurate
@@rufinovillasis760 dapat may dalawang 25 kilo taz hanapin mo yung manual
hello from PH question do you encountered the down button broken 4008s model? btw new subcriber :)
@@roymiraflor4005 my machine K. K2. T. If the same Hydrolic . Maybe I can help you
I have negative test fail stab any ideas ? ❤
@@abdulh8958 👍 K-machine! Check your pump head. Air separator. Valve 34. 32. 33. 31.
Let me know
How can I get English Videos please
Can we find English Translation? Looks very useful videos.
Hello my friend, where to look if the conductivity is very high 16-17The pumps are working, the balancing chamber has been replaced, the conductivity sensor has been replaced, the BIC and СON pumps have been checked, what could it be?
@@MODoffRoad Check valve 31. 33. 9. Or 10 let me know
@@kamakinavlog6103 Hi, I checked 31 and 33 Valves, the drain works fine, what function are the valves 9 and 10 responsible for your device ? I have model 4008 Without CDS, I don't have 9-10 valves. I studied your device but I didn't find the valves you were talking about in the manual.
@@kamakinavlog6103 hi
Check all board including the motherboard
Hi, I happy to see that your videos, its really appreciate. I am from Bangladesh. I am working on FRESENIUS 2008K machine for last 8 years.
Sir saan po pwedi mkabili yang calibration gauge mo na dalawa?? Kailangan q kc nyan wla nmn sa online
@@Mark-o4k presenius USA manufacturing inc
Tanong lng po sir. saan po e.connect yong red at blue?
Acid red & blue bicarb
@@kamakinavlog6103 Ask po ako sir kung meron po bang 90XL meter na pang calibration dito sa Pinas? or baka may kilala po kayo na nag benta nyan sir. salamat
Boss meron ka bang second hand na western meter
@@rodelgaryerwin6687 fresenius usa manufacturing inc
@@ToragsoyTv fresenius USA manufacturing inc
Good day sir Meron k bang for sale na mga parts 2008k?saka meron k din bang alam na benebenta na western meter kahit na second hand
@@rodelgaryerwin6687 fresenius USA manufacturing inc
Master?? Regarding sa blood pump, na E.03 may magagawa ba jan na problmea
@@lenardjericperez15 replaced motor gear
Sir sana po matulongan mo ako sa error ng machine ko na 4008a
لو سمحت محتاج تعليق تحت باللغه العربيه للفيديو
Please use English subtitle for every videos. Watching from Bangladesh ❤
Ganda ng Scrub mo idol.saan b maka order nyan?
Mandala online
I recently went back to working on the 2008 Series! And your videos have been a great help! Keep up the good work and troubleshooting! 🤙
@@SpartanDynamicsSolutionsLLC thank you..
Need your help regarding Fresenius machine V130 failure
@@ayshan__ tell me what happened?
Hi Engineer