Very good presentation to the fellow electrician practitioner. Comments: 1. Is not a violation,your wiring connection is correct, in Line to Nuetral Configuration of NEMA 1 type Enclosure, Disconnecting Means or Isolation Switch 2. Schematic diagram also in correct, One Main Circuit Breaker, 2 pole,220V/230V, Single Phase(L-N),60Hz, in two Circuit runs for lighting & outlet 3. Electric Cooperative will surely accepted that wiring methodology 4. Explanation for protection of equipment at load side, in PEC Stds, Individual Circuit shall have single CB/1 pole/Fuse protection for any faults problem (shorted, & grounded ckts) Thats why, We removed the 2 pole gang for switching On/Off & auto trip fault position purposes. If so, happen, di mo tinanggal ang 2 gang trip, pag meron faults sa Convenience Outlets & lighting, sabay mag trip, or nawalan ka ng electric current (No Power) a very good, tips to the beginner electrician. Eto ay for economical only, if you used a 1 x 2pole CB (Trip Quick Break type, mostly residential used, bolt on or plug-in type) But in Engineering Standards,PEC,NEC, Line to Nuetral (L- 220V/230V live / Neutral- ZeroV) Line to Line (L1-110 to L2-110V or +_ 10%V) not applicable the jumper at Line Side of CB, ex 20AT/2P Notes: meron kaibahan mga guys, In circuit breaker, we use the term pole Symbol 1P,2P & 3P or 4P is different miss interpret natin 1P as single phase, 2P is also single phase, 3P is three phase is system voltage. Meron naman breaker na one pole gang lang siya, switching off/on, but 2Wire system, yan ang di puede gamitin na type of breakers By principle, evaluates the type of breaker na gagamitin, puede 2pcs× 1pole 20AT(Amper Trip) at eto kay elct pinoy 1x 2Pole 20AT MCB 1x2P 20AT or depende sa sched of load ampacity ex1x 16AT/1P for lighting & 1x20AT/1P,or 1x20AT/1P integrated outlet/lighting & 1x30AT/1P (special outlet aircon, range, heater) Neutral is coupled joints together wrapped w/ elctl tape, as long naka insulated, kasi pag yon Neutral at body metal ground mag kadikit, grounded ckt mangyari im a complete flow of circuit loads. Magkalaban ang Neutral at Ground, kaya usually in standard practice meron plastic insulator or Bus Isolator in Neutral at PE/Ground Bus fixed on the body of metal enclosure(non carrying current) Neutral is zero volt in wye connection,in parallel phase line connection, mag asawa sila sa Neutral at phase line, kaya balot ng tape para di madikit da live wire at body ground. Thanks to Electl pinoy, mabigyan mo ng tips, techniques, ang mga beginner electricians or di pa nakakabit sa Line to ground cooperative, line to line meralco .
Tama ka boseng not a violation po iyan pero peligro po iyan kung sakaling ma baliktad ang connection sa may service entrance po marami napo akong na experience na reklamo na kuryente kahit naka off yung breaker. Mas safety po ang live at neutral/ground connected in a breaker.
Salamat po sa feed back mga master godbless po. Bali pinakita ko lang po ganyang style ng connection. Kc malimit sa probinsya ganyan ang nagiging connection. But d ko nman nirerecomment na gayahin ang gangyang connection lalong lalo na kung mga mga appliances. Iyan is para lang po sa mga bahay na mababa lang po load. Salamat po sa feed back master godbless po.
@@ElectricalPinoyTutorialTVgood eve sir. Now lng ako nkakapanood ng mga electrical house wiring sa edad kong ito. Gusto ko kasi matuto. Yung sa bahay ng isang bayaw ko 1 circuit breaker lng siya. Di ko alam kung ilan yung outlet at switch ng bahay nila. Pero di ko pa nkita kung ganyan yung ginawang wiring ng nag istila ng kuryente, na pinaghiwalay yung breaker ng ilaw at ng outlet. Sana matuto ako khit matanda na ako😁 Salamat sa video tutorial mo sir.
Sir idol dapat mayroon diagram para sure na masundan ang ung tutorial Sa mga gustong matoto ng electrical Ng mga bagitong subscribers na kagaya nmin na gustong matoto Kailangan talaga ang diagram para masundan ang pag wiring Salamat po,
Very nice explanation boss..maliban s color coding ng wire..green po ay para s grounding even though pwedeng gamitin pero dapat sunod din s color code..un lng po other than that..salute po...
D nmn tlga.tinuturo yan kase wala nmng logic ung ganyang wiring.. Kung ganyan lang din ang gagawin mo dahil iisang breaker lang ung gagamitin mo pra sa lighting at CO maglagay kanlng ng tig 2 wire sa terminal ng load side..nonsense nmn kasi yan kasi if ever may mag short circuit parehas din nmn yan sila mawawalan ng supply...
Ang galing gusto ko matutu mag electrical Ng koryente Lahat Ng video mo sa you tube panunuorin ko para matutu ako at makakuha pa Ng kaalaman sa trabaho God bless you sayo boss Sana marami pang makapanood sayo, salamat sa pag sheare sa kaalaman mo🙂🙂
Ito talaga yung hinahanap ko ..kase ganito sa amin hiwalay yung ilaw at c.o na curios talaga ako. kung pano yun nagawa. salamat idol sa tips ..ngayon alam kona😊😍
Good job idol..actualy ok naman yan kasi disim tping lng nman yan sa plangka switch ang kaibahan lng circuit breaker lng gamit nya..pinakita lng nman nya kung paano gawin ang isang CB. Dlawa ang functionable gmit ang isang CB..ganyan nman tlga bxta probnsya tipid2x sa gastus.
thank you po xa pa shout out idol ok Lang yun ganyang connection kung maliit Lang yung bahay pra madali Lang ma identify ng may ari kong sakaling mag short po dahil hiwalay yung outlet at saka ilaw ....thank you po xa pag share ng experience mo idol 💗💗💗 isa po akong electrical Engineering student na humahanga xa mga kaalaman mo about xa wiring installation ....
Salamat po sa feedback master GODBLESS PO💜💜💜 KINDLY SUPPORT AND LIKE,SHARE AND FOLLOW OUR FACEBOOK PAGE AND SUBSCRIBE MY TH-cam CHANNEL: FB PAGE LINK: facebook.com/Electrical-Pinoy-Tutorial-TV-104634308893921/ TH-cam CHANNEL LINK: th-cam.com/users/ElectricalPinoyTutorialTV THANK YOU! GOD TO BE THE GLORY! GOD BLESS 💜💜💜
Idol pwd ba sa surface breaker ako mag lagay ng ground kc ung extension ko my ground 3 ang wire pate ung exhaust wire 3 din my para sa ground at ung saksakan at pang sak2 sa extension 3 din pwd ba sa surface breaker ako mag lagay
Thanks for sharing a knowledge po..new tips..line hot and neutralize ground.. directly ang neutral..ang line hot ang may circuit breaker always..out and light.. jumper type..in 1 breaker.. going to outlet and light switch..and neutral line direct to light and outlet.. pang province type...
Yup tao lng tayo na nagkakamali, itong setup parang style sa use na live wire sa breaker, neutral ay sa bus bar ng neutral but d2 no earth ground. Sa US as u said two line are 110v n 1 line neutral. Sa manila lng dko alam ano setup ng meralco 2 line 110v or as like here in the province 1 line 220 n 1 neutral. Thank you for your info here. I am just normal watcher not electrician
ayos idol may mga natutunan aqo s pag panood s video tutorial mo salamat s pag share ng kaalaman.tamsak❤ sayo at nakadikit nang bahay q.s bahay mo 💯%suportado ang channel mo.god bless s family mo👪🙏
Tama po yang Installation mo ka-kuryente, at applicable yan sa Line to Neutral at Line to Ground at malimit ang mga ganyang Systema ng connection sa mga maliliit na Bahay sa Probinsya.. So Thumbs up 👍 Sayo ka-Kuryente at mabuhay ka!
Tama ka bosing sa Probinsya sa maliit na Bahay ganyan talagsa gamit sa pag separate sa lighting at outlet, pero may Mali kalang kaunte naman, doon sa sinabi mong may short sa Isang linya Isa lang Ang mag trip dahil tinanggal Muna Ang blue holder sa breaker, Hindi po yang totoo, magkasabay parin Yan Sa pag trip pag may short Ang Isa, pwede mo naman subukan,
Salamat po sa feedback master GODBLESS PO💜💜💜 KINDLY SUPPORT AND LIKE,SHARE AND FOLLOW OUR FACEBOOK PAGE AND SUBSCRIBE MY TH-cam CHANNEL: FB PAGE LINK: facebook.com/Electrical-Pinoy-Tutorial-TV-104634308893921/ TH-cam CHANNEL LINK: th-cam.com/users/ElectricalPinoyTutorialTV THANK YOU! GOD TO BE THE GLORY! GOD BLESS 💜💜💜
Boss suggestion ko lng ituro mo rin na bago mag energize ng power. Kailangan testeran Muna NG continuity ang linya ng bago mong ginawa Para iwas hazard.
ok idol marami kung natutunan,kaso lng idol sa mga bago nalilito jan kasi daming kulay ng kurdon na ginamit mo,mas maganda sana kung 1 kulay nlng sa neutral at sa hot wire
Idol salamat po sa bagong kaalaman, idol sa 20 amphere po na main, ilan po ang ikaw at outlet ang pwede,, at mula po sa circuit breake san po galng ang pianggakingan nyan sa servince entrance po ba o meter... Maraming salamat po
Anglican boss ng pagka explained mo. Pwedeng pwede sa probinsya. Lalo na sa kulang sa budget. 1 breaker nalang. Instead na 3 pcs na breakers. Tanong ko lang boss ano bang ampers ng breaker na gagamitin Para sa set up na yan?
Sa meralco Naman line to line..110 by 110.. equal 220...3wires..110+110+0earth... floating ground ang gamit niya sa klase Ng transformer..kaya tatlo ang wires niya..kaya kung gamitin mo ang set up sa tatlong wire..lift side is 110.. right side is 220...yong kabila lift kaya 110 is ginamit ang earth ground..at isang line na 110..kaya dito sa NCR..Yan ang setup sa maka Lumang Bahay..110..@220.. piro unti unti na nawala ang 110..halus 220 na lahat..
Master, gaano b katotoo n kpag line to neutral ang service provider is kpag line to ground daw di n raw aandar o mgpa function ang meter base , kasi nga daw ground n kumuha ng isang linya imbes n s neutral n galing sa poste.. Gnda ng paliwanag master, tlgang kuhang kuha ng bwat viewer n kgya ko ibig mo sabihin.thankyou master
Master correct term lang po wla po tayong connection na line to ground line to neutral po. Ang ground nman is protection sa mga appliances. Pero pag dating sa probinsya ung neutral kaya nagiging ground is dumikit po sa meter base. Matatawag n po nating ground sya. Sa system kc d2 sa probinsya. Ang neutral is still a ground kc naka base tayo sa connection ng transformer po. Still na mag fa function ang electric meter kung ground ang nakalagay sa terminal. Kc ang electric meter ng power provider ang naka design na po ganung connection. Salamat po sa feedback master godbless po.
Sir napakahusay muna electrician maliwanag mag explain. Ang maibigay ko na grado ay 10/10 equivalent of 100 perfect de kalidad ka na electrician.👍👍👍
Salamat po sa feedback master godbless po😊❤️
Bagong Kaalaman Para sa Mga Newbie Kamasta . Good Job
Salamat po sa feedback master godbless po.
Nice tutorial idol malinaw ang mga detalye mo Dagdag kaalaman para sa katulad ko na nagsisimula palang para matu2 Ng ganitong wiring more power pa
Salamat po sa feedback master godbless po.
Very good presentation to the fellow electrician practitioner.
Comments:
1. Is not a violation,your wiring connection is correct, in Line to Nuetral Configuration of NEMA 1 type Enclosure, Disconnecting Means or Isolation Switch
2. Schematic diagram also in correct,
One Main Circuit Breaker, 2 pole,220V/230V, Single Phase(L-N),60Hz, in two
Circuit runs for lighting & outlet
3. Electric Cooperative will surely accepted that wiring methodology
4. Explanation for protection of equipment at load side, in PEC Stds, Individual Circuit shall have single CB/1 pole/Fuse protection for any faults problem (shorted, & grounded ckts)
Thats why, We removed the 2 pole gang for switching On/Off & auto trip fault position purposes. If so, happen, di mo tinanggal ang 2 gang trip, pag meron faults sa Convenience Outlets & lighting, sabay mag trip, or nawalan ka ng electric current (No Power) a very good, tips to the beginner electrician.
Eto ay for economical only, if you used a 1 x 2pole CB (Trip Quick Break type, mostly residential used, bolt on or plug-in type)
But in Engineering Standards,PEC,NEC,
Line to Nuetral (L- 220V/230V live / Neutral- ZeroV)
Line to Line (L1-110 to L2-110V or +_ 10%V) not applicable the jumper at Line Side of CB, ex 20AT/2P
Notes: meron kaibahan mga guys,
In circuit breaker, we use the term pole
Symbol 1P,2P & 3P or 4P is different
miss interpret natin 1P as single phase, 2P is also single phase, 3P is three phase is system voltage.
Meron naman breaker na one pole gang lang siya, switching off/on, but 2Wire system, yan ang di puede gamitin na type of breakers
By principle, evaluates the type of breaker na gagamitin, puede 2pcs× 1pole 20AT(Amper Trip) at eto kay elct pinoy 1x 2Pole 20AT
MCB 1x2P 20AT or depende sa sched of load ampacity ex1x 16AT/1P for lighting & 1x20AT/1P,or 1x20AT/1P integrated outlet/lighting & 1x30AT/1P (special outlet aircon, range, heater)
Neutral is coupled joints together wrapped w/ elctl tape, as long naka insulated, kasi pag yon Neutral at body metal ground mag kadikit, grounded ckt mangyari im a complete flow of circuit loads. Magkalaban ang Neutral at Ground, kaya usually in standard practice meron plastic insulator or Bus Isolator in Neutral at PE/Ground Bus fixed on the body of metal enclosure(non carrying current)
Neutral is zero volt in wye connection,in parallel phase line connection, mag asawa sila sa Neutral at phase line, kaya balot ng tape para di madikit da live wire at body ground.
Thanks to Electl pinoy, mabigyan mo ng tips, techniques, ang mga beginner electricians or di pa nakakabit sa Line to ground cooperative, line to line meralco .
Tama ka boseng not a violation po iyan pero peligro po iyan kung sakaling ma baliktad ang connection sa may service entrance po marami napo akong na experience na reklamo na kuryente kahit naka off yung breaker. Mas safety po ang live at neutral/ground connected in a breaker.
Salamat po sa feed back mga master godbless po. Bali pinakita ko lang po ganyang style ng connection. Kc malimit sa probinsya ganyan ang nagiging connection. But d ko nman nirerecomment na gayahin ang gangyang connection lalong lalo na kung mga mga appliances. Iyan is para lang po sa mga bahay na mababa lang po load. Salamat po sa feed back master godbless po.
@@ElectricalPinoyTutorialTVgood eve sir. Now lng ako nkakapanood ng mga electrical house wiring sa edad kong ito. Gusto ko kasi matuto. Yung sa bahay ng isang bayaw ko 1 circuit breaker lng siya. Di ko alam kung ilan yung outlet at switch ng bahay nila. Pero di ko pa nkita kung ganyan yung ginawang wiring ng nag istila ng kuryente, na pinaghiwalay yung breaker ng ilaw at ng outlet. Sana matuto ako khit matanda na ako😁
Salamat sa video tutorial mo sir.
Sir idol dapat mayroon diagram para sure na masundan ang ung tutorial
Sa mga gustong matoto ng electrical
Ng mga bagitong subscribers na kagaya nmin na gustong matoto
Kailangan talaga ang diagram para masundan ang pag wiring
Salamat po,
sir maraming salamat sa explanation atleast malinaw na sa akin ang idea. dati nalito po ako sa connection na yan. Long live po and God bless
Salamat po sa feedback master godless po.
Ok yan Idol .... Para mga walang budget sa circuit breaker nice 👍
Very nice explanation boss..maliban s color coding ng wire..green po ay para s grounding even though pwedeng gamitin pero dapat sunod din s color code..un lng po other than that..salute po...
Salamat po sa feedback master GOBLESS Po😊❤️
For. Me Master.. Dinadaan ko tlaaga yan sa Breaker kahit line to neutral tayo... Well explained naman Master...
Salamat po sa feedback master godbless po.
good job idol ..congrats
.simpleng electrician din ako at bigginer marami akong natutunan Sayo .. Tama ka lahat Hindi tinuturo sa school
Salamat po sa feedback master GODBLESS PO💜💜💜
D nmn tlga.tinuturo yan kase wala nmng logic ung ganyang wiring..
Kung ganyan lang din ang gagawin mo dahil iisang breaker lang ung gagamitin mo pra sa lighting at CO maglagay kanlng ng tig 2 wire sa terminal ng load side..nonsense nmn kasi yan kasi if ever may mag short circuit parehas din nmn yan sila mawawalan ng supply...
Ang galing gusto ko matutu mag electrical Ng koryente Lahat Ng video mo sa you tube panunuorin ko para matutu ako at makakuha pa Ng kaalaman sa trabaho God bless you sayo boss Sana marami pang makapanood sayo, salamat sa pag sheare sa kaalaman mo🙂🙂
Salamat po sa feedback master GODBLESS PO
Okay po yan ganyan din ginawa ko sa probin cya namin I salod you tuloy mo lang yan para para marami makaalam god bless po.
Salamat po sa feedback master godbless po.
Thank u boss s bnigay mong idea khit ppano nkapulot kmi Ng konting aral n tlad naming mga beginner thank u boss
Salamat po sa feedback master goodbles po. ❤️
Nice loads. Yan ang ginaya ko sa bahay kx sira n ung safety switch ko.
Another knowledge nanaman po ito. Thanks lodi. Ingat po lagi . God bless 🙏
Salamat po sa feebback master. GODBLESS PO.❤️😊
Ito talaga yung hinahanap ko ..kase ganito sa amin hiwalay yung ilaw at c.o na curios talaga ako. kung pano yun nagawa. salamat idol sa tips ..ngayon alam kona😊😍
Thanks po sa feedback master godbless po. ❤
Good job idol..actualy ok naman yan kasi disim tping lng nman yan sa plangka switch ang kaibahan lng circuit breaker lng gamit nya..pinakita lng nman nya kung paano gawin ang isang CB. Dlawa ang functionable gmit ang isang CB..ganyan nman tlga bxta probnsya tipid2x sa gastus.
Tamah po. Para sa mga nag titipid po. Salamat po sa feedback master godbless po.
Paano boss kong mag dagdag ka ng breaker sa ilaw at saksakan
Sir maganda Ang iyong pagtuturo sa actual .. sir request ko na mag explain pa kayo ng number ng wire ayon sa taas ng ampers. God bless you
practicality okay yan idol! wag lang safety ang pag-uusapan
Salamat po sa feedback master godbless po.
Boss good Idea wala akong alam sa wiring pero sa kakapanood ko nakakasunod na thanks
Salamat po sa feed back master and MERRY CHRISTMASS TO YOUR FAMILY! GOBLESS!!❤❤
FR: Electrical Pinoy Tutorial TV
thank you po xa pa shout out idol ok Lang yun ganyang connection kung maliit Lang yung bahay pra madali Lang ma identify ng may ari kong sakaling mag short po dahil hiwalay yung outlet at saka ilaw ....thank you po xa pag share ng experience mo idol 💗💗💗 isa po akong electrical Engineering student na humahanga xa mga kaalaman mo about xa wiring installation ....
Sure po master. Salamat po sa feedback master godbless po.
OK Yan ka electrician.. Walang Problema.. Shout out po.. Electrician dito sa Kuwait ❤😊
Sure po. Pacenxia na po late ang replay. Salamat po master sa feedback godbless po❤️
Dagdag kaalaman ito sa akin kaya thank you po. Salamat din sa tip about tripholder. Now ko lang nalaman na pwede palang tanggalin yan. God bless.
Salamat po sa feedback master GODBLESS PO💜💜💜
KINDLY SUPPORT AND LIKE,SHARE AND FOLLOW OUR FACEBOOK PAGE AND SUBSCRIBE MY TH-cam CHANNEL:
FB PAGE LINK:
facebook.com/Electrical-Pinoy-Tutorial-TV-104634308893921/
TH-cam CHANNEL LINK:
th-cam.com/users/ElectricalPinoyTutorialTV
THANK YOU! GOD TO BE THE GLORY! GOD BLESS 💜💜💜
Nice vlog sir. Salamat sa pag feature . God bless sir 👍
Salamat po sa feedback master godbless po.
Ilang ilaw po at outlet ang pweding ilagay sa isang cb?salamat po tanong lng po☺️
Ok naman ung mga ninirang yan masmalaki ang kaalaman nating mga, electrician mas magaling tayu kisa sa knila
Tamah po master.
Kopleto's Rekado's,Ang demo idol, theory,& slomo actual,wiring connection pavor sa mga baguhan, more power idol.
Salamat po sa feedback master godbless po.
Magaling ka po, humble ka . nakakabilieve.
Tama yan applicable lang po yan sa mga line to ground system.
Salamat po sa feedback GODBLESS PO💜💜💜
Idol pwd ba sa surface breaker ako mag lagay ng ground kc ung extension ko my ground 3 ang wire pate ung exhaust wire 3 din my para sa ground at ung saksakan at pang sak2 sa extension 3 din pwd ba sa surface breaker ako mag lagay
Tanong ko po sayo boss bakit po nka 40 lahat yon,tapos yung wire genamit mo # 12 hndi # 8 kasi 40 po yun ehh
salamat sir napaka klaro nyo po mag turo...
Salamat po ss feedback master. Godbless po.
Ang Ganda Po ng tutorial mo loads same Po tayo electrician
Nice 👍 ganyan dati nkikita ko top s fuse box... Ok din ganyan s line to ground...
maganda pagka demo idol. mabilis lng maintindihan♥️
Ayos yan lods galing mo magpaliwanag tuloy tuloy mo lang ang pagtuturo.
Salamat po sa feedback master godbless po.
Sobrang linaw idol ok paliwanag mo ty..
Salamat po sa feedback master GODBLESS PO💜💜💜
Ask ko lng idol ok lng, natural lng ba na mag spapark yung outlet pag saksakan mo ng plug? Kasi yung ibang outlet hindi nag spapark eh, salamat
Salamat sa paliwanag mabihay ka god bless
Salamat po sa feedback master godbless po❤️😊
Boss ok yan, napaka linaw moh mag paliwanag, i salute you...
Same din dito sa Batangas, Line to Nuetral system ..watching at Batangas
Salamat po sa feedback master gobless po
Boss thank u for sharing ur knowledge in terms of electricity god bless po tcare boss
Salamat po sa feedback master GODBLESS PO☺️
Makaka tulong po ang pag tuturo niyu po Sa mga interesado tulad ko Kaya pls dagdagan niyu pa pag wiring.
Shot out bro . from 🇩🇯 Africa salamat sa paliwanag you are the man
Sure po.
Salamat po sa feed back master! MERRY CHRISTMASS and HAPPY NEW YEAR TO YOUR FAMILY! GOBLESS!!❤❤
Greetings From: Electrical Pinoy Tutorial TV
Maraming salamat idol.marami akung natututunan sa mga tutorial mo.
Salamat po sa feedback master godbless po.
Salamat idol my natutunan nanaman Ako god blessed idol
Salamat po sa feedback master godbless po💜💜
Maraming salamat kaibigan mabuhay ka.
Salamat po sa feedback GODBLESS PO💜💜💜
good presentation sir. medyo nakakalito lng ung mga 'ah'.
Salamat po sa feedback master godbless po❤️❤️
Salamat sa paliwanag kahit matagal,, dag dag ka a laman po,, salamat,,😇
Salamat po sa feedback master godbless po💜💜
galing. daming matutunan sa tutorial na to. Thanks sir.
Salamat po sa feedback master GODBLESS PO
Salamat boss. Dagdag kaalaman.
Salamat po sa feedback master GODBLESS PO💜💜💜
Hayaan mo na sila idol,nang aasar lang mga yan...buti ka pa nkakatulong....salamat sa mga tip mo boss
God bless saiyong blog boss! Maraming salamat sa dagdag kaalaman.
Maramning salamat master sa suporta.
Gobless
Thanks for sharing a knowledge po..new tips..line hot and neutralize ground.. directly ang neutral..ang line hot ang may circuit breaker always..out and light.. jumper type..in 1 breaker.. going to outlet and light switch..and neutral line direct to light and outlet.. pang province type...
Yup tao lng tayo na nagkakamali, itong setup parang style sa use na live wire sa breaker, neutral ay sa bus bar ng neutral but d2 no earth ground. Sa US as u said two line are 110v n 1 line neutral.
Sa manila lng dko alam ano setup ng meralco 2 line 110v or as like here in the province 1 line 220 n 1 neutral. Thank you for your info here. I am just normal watcher not electrician
Salamat po sa feedback master GODBLESS PO💜💜💜
ano advatage ng lugspag iyon ang gamitin sa cb instead of bold wire....
Mr. SO salamat sa kaalaman 👍
Salamat po sa feedback master godbless po💜💜
Salamat sa magandang paliwanag Idol...
Salamat po sa feedback master GODBLESS PO💜💜💜
yun oh nice boss salamat sa dagdag kaalaman tungkol sa electrical..pa shout out boss salamat..
Sure po Salamat po sa feedback master godbless po.
ayos idol may mga natutunan aqo s pag panood s video tutorial mo salamat s pag share ng kaalaman.tamsak❤ sayo at nakadikit nang bahay q.s bahay mo 💯%suportado ang channel mo.god bless s family mo👪🙏
Salamat po sa feedback master godbless po.
Salamat idol sa karagdagang aral na natutunan namen mabuhay poh kayo salamat..
Salamat po sa feedback master godbless po.
link po ni practical electrical idol..ng sa ganon ma kita ko vedio nya
Thanks sir malinaw pa sa ilaw mo.mabuhay ka sir
Ayos sir, nice tutorial!
Napaka ganda ng presentation mo ka electrician .. keep it up lodi .. same hir electrician
Salamat po sa feedback master goodbles po. ❤️
Tama po yang Installation mo ka-kuryente, at applicable yan sa Line to Neutral at Line to Ground at malimit ang mga ganyang Systema ng connection sa mga maliliit na Bahay sa Probinsya.. So Thumbs up 👍 Sayo ka-Kuryente at mabuhay ka!
Salamat po sa feedback master godbless po💜💜
Tama ka bosing sa Probinsya sa maliit na Bahay ganyan talagsa gamit sa pag separate sa lighting at outlet, pero may Mali kalang kaunte naman, doon sa sinabi mong may short sa Isang linya Isa lang Ang mag trip dahil tinanggal Muna Ang blue holder sa breaker, Hindi po yang totoo, magkasabay parin Yan Sa pag trip pag may short Ang Isa, pwede mo naman subukan,
Salamat sa video na to master, laking tulong neto. God bless po.
Salamat po master sa feedback godbless po❤
@@ElectricalPinoyTutorialTV sir Tanung Lang ung po b neutral line PWD gawin grounding iconnect s body ground Ng Ng appliances like s ref.?
Nice tutorial idol, additional knowledge to your fans & viewers. God bless
Salamat po sa feedback master godbless po.
Gd pm idol maganda ang pagka explain niyo po.mas maganda kong putolin po o kaya hatiin nlang sa dalawa. Yong on/off niya
Thanks po sa feedback master godbless po. ❤
Thanks sa kaalaman
Salamat po boss sa ipinakita nyo may idea napo ako
Salamat po sa feedback master goodbles po. ❤️
Dagdag kaalam yan para sa amin idol tuloy mo lang mag apload hwag mo pansinin mga basher inggit lang sila sa katulad nating bloger hehe salamat idol
Salamat po sa feedback master godbless po.
Very clear naman
Salamat po sa feedback master godbless po💜💜
Ganyan din wiring ko sa Bahay anng papa ko ok lang Yan depinde na sa gstu nio..Ang importante saktu Ang connection..
Salamat po sa feedback master godbless po.
Aus yan lods salamat sa pg share pra sa mga baguhan .
Salamat po sa feedback master GODBLESS PO
ok malinaw....salamat sa muli...
Salamat po sa feedback master GODBLESS PO💜💜💜
KINDLY SUPPORT AND LIKE,SHARE AND FOLLOW OUR FACEBOOK PAGE AND SUBSCRIBE MY TH-cam CHANNEL:
FB PAGE LINK:
facebook.com/Electrical-Pinoy-Tutorial-TV-104634308893921/
TH-cam CHANNEL LINK:
th-cam.com/users/ElectricalPinoyTutorialTV
THANK YOU! GOD TO BE THE GLORY! GOD BLESS 💜💜💜
Ngayon naeentihan kona. Salamat idol.
Salamat po sa feedback master godbless po. ❤️😊
Boss suggestion ko lng ituro mo rin na bago mag energize ng power. Kailangan testeran Muna NG continuity ang linya ng bago mong ginawa Para iwas hazard.
Cge master. Salamat po sa feedback master godbless po.
SALAMAT SA PAG SHARE NG KAALAMAN SER
Salamat po sa feedback master GODBLESS PO💜💜💜
Linaw ng paliwanag sir dagdag kaalaman
Thanks po sa feedback master godbless po. ❤
ok idol marami kung natutunan,kaso lng idol sa mga bago nalilito jan kasi daming kulay ng kurdon na ginamit mo,mas maganda sana kung 1 kulay nlng sa neutral at sa hot wire
Sa susunod po master. Salamat po sa feedback master godbless po.
Nice one BUDDY..SALAMAT sa share
thanks po sa feedback master godbless po!
Good clear yun demo 👍
Salamat po sa feedback GODBLESS PO💜💜💜
Salamat po Sa pag turo.
Salamat po sa feedback master godbless po❤️😊
Galing idol..thanks
Salamat idol sa tutorial additional kaalamam ...
Kudos kuya 👏🏻👏🏻👏🏻
Salamat po sa feedback master godbless po😊❤️
Sir ..Salamat May natutunan ako...
Salamat po sa feedback master godbless po.
Galing mo brod Sana pasok mo din ako sa wrk mo electrician din ako brod delta sigma family ako brod long live
Idol salamat po sa bagong kaalaman, idol sa 20 amphere po na main, ilan po ang ikaw at outlet ang pwede,, at mula po sa circuit breake san po galng ang pianggakingan nyan sa servince entrance po ba o meter... Maraming salamat po
Anglican boss ng pagka explained mo.
Pwedeng pwede sa probinsya.
Lalo na sa kulang sa budget.
1 breaker nalang. Instead na 3 pcs na breakers.
Tanong ko lang boss ano bang ampers ng breaker na gagamitin Para sa set up na yan?
20 to 30amps
20 amps. Minimum. Salamat po sa feedback master godbless po.
Sir paano po ang connection or topping pag magdagdag ng outlet or ilaw po sa connection na yan po! salamat sa bahagi
Good job idol. God bless
Galing mo talaga idol❤
Salamat po sa feedback master. GODBLESS Po❤️
Okey Yan sir safe ako Dyan god bless,
Salamat po sa feedback master godbless po😊❤️
Nice tutorial idol❤
Slamat po sa feedback master GODBLESS PO❤️
Sa meralco Naman line to line..110 by 110.. equal 220...3wires..110+110+0earth... floating ground ang gamit niya sa klase Ng transformer..kaya tatlo ang wires niya..kaya kung gamitin mo ang set up sa tatlong wire..lift side is 110.. right side is 220...yong kabila lift kaya 110 is ginamit ang earth ground..at isang line na 110..kaya dito sa NCR..Yan ang setup sa maka Lumang Bahay..110..@220.. piro unti unti na nawala ang 110..halus 220 na lahat..
Same lang sila sa moresco sir ?
👍thumbs up boss always watching ur tutorial.
Salamat po sa feedback master godbless po.
Agree ako Master.... Ayos...
Very informative ❤❤❤
Master, gaano b katotoo n kpag line to neutral ang service provider is kpag line to ground daw di n raw aandar o mgpa function ang meter base , kasi nga daw ground n kumuha ng isang linya imbes n s neutral n galing sa poste..
Gnda ng paliwanag master, tlgang kuhang kuha ng bwat viewer n kgya ko ibig mo sabihin.thankyou master
Master correct term lang po wla po tayong connection na line to ground line to neutral po. Ang ground nman is protection sa mga appliances. Pero pag dating sa probinsya ung neutral kaya nagiging ground is dumikit po sa meter base. Matatawag n po nating ground sya. Sa system kc d2 sa probinsya. Ang neutral is still a ground kc naka base tayo sa connection ng transformer po. Still na mag fa function ang electric meter kung ground ang nakalagay sa terminal. Kc ang electric meter ng power provider ang naka design na po ganung connection.
Salamat po sa feedback master godbless po.
Maraming salamat master, Godbless din po..
Ayos idol my dagdag kaalam nnaman
Salamat po sa feedback master godbless po.
Ok yan para sa amin idol yung line to nutral
Salamat po sa feedback master GOBLESS Po😊❤️
Ang galing mo sir
Thanks po sa feedback master godbless po. ❤
Boss new subscriber ako from uae.abu dhabi
Gets ko sir, thanks for idea
Salamat po sa feedback master goodbles po. ❤️