    Mark from Derby .
    Had a problem flushing continuously to get water to come through at a dribble .fitted a new syphon on to old down pipe as you just clip a new one on . But the downpipe had enlargened slightly as the lever was pulling at an angle of the plunger ..wore out the washer on plunger and distorted the down pipe pulling at that angle ...so be ware get z longer lever ..so it lifts lever straight up .. I put margarine or silcone gel to seal the syphon to the down pipe ..properly .. all works now .

  • @niallchurch2679
    @niallchurch2679 ปีที่แล้ว

    Why do I need to adjust the size as in your video?

    • @thomasdudleyplumbing
      @thomasdudleyplumbing  ปีที่แล้ว

      Hi Niall, the height is adjusted to suit the water level within the cistern. If the syphon height is set too low it may internally overflow, too high and it will not overflow if required. Kind regards TYDE