  • How to properly set up, SST, and initiate ventilation with the Puritan Bennit 980 ventilator.

ความคิดเห็น • 16

  • @mobenah
    @mobenah 5 ปีที่แล้ว +4

    very good presentation, I like the close ups, I was hoping though during SST that you zoomed down so we can see what is being removed or added, but otherwise very informative.

  • @antoninonastasi3719
    @antoninonastasi3719 2 ปีที่แล้ว +2

    Aerogens go on the dry side per the aerogen quick reference guide FYI

    • @latentimage74
      @latentimage74 3 หลายเดือนก่อน

      yep, I talked to Jim fink in an elevator about the same thing once

  • @mdtoufikul6430
    @mdtoufikul6430 3 ปีที่แล้ว

    very good presentation,

  • @ma0091
    @ma0091 6 ปีที่แล้ว

    Thank you very much. Really helpful.

  • @Malficion
    @Malficion 6 ปีที่แล้ว +1

    Ah... Good times, first semester, we did a tour of the lab. My smart self saw a flippy switch and turned on the 980. The lab professor was pissed. Apparently they were 70k+ a piece and if the cap was on it the machine would get damaged.

  • @williamhuang4140
    @williamhuang4140 4 ปีที่แล้ว

    Thank you so much

  • @hunteroftruth4986
    @hunteroftruth4986 3 ปีที่แล้ว

    To fix that leak failure issue tear the small cap covering your water feed line from the chamber cover and press it on firmly.

  • @idaliab1
    @idaliab1 5 ปีที่แล้ว

    There are some HME'S that are design for aerogen, which it has a tab that goes up and down so you can give the neb tx's

  • @tamraparrish3526
    @tamraparrish3526 7 ปีที่แล้ว

    What about the amount of dead space for the aerogen? Or do you not need to worry about that with the aerogen?

  • @tamraparrish3526
    @tamraparrish3526 7 ปีที่แล้ว

    At the facilities I have worked at we use the aerogen with an HME, but we put it in front of the HME closest to the patient.

    • @rhenmitchell5629
      @rhenmitchell5629  7 ปีที่แล้ว

      Tamra Parrish it has been my experience that ventilated patients receiving aerogen therapy also require frequent suctioning and we require etco2 monitoring for all vent patients. Usually this makes an HME impracticle.

    • @rhenmitchell5629
      @rhenmitchell5629  7 ปีที่แล้ว

      Dead space from an inline aerogen is negligent for nearly all adult patients. In the case of neonates, most modern ventilator utilize flow sensors at the end of the inspiratory circuit, which will cause the vent to automatically compensate for deadspace based on insp/exp measurments. If your neonatal vent doesnt have a flow sensor, then you may have to adjust your settings.

  • @cecilialee186
    @cecilialee186 3 ปีที่แล้ว

    I don't know thatvI agree with where he put the aerogen. The company recommends the dry side.

  • @montadharaltaii7604
    @montadharaltaii7604 3 ปีที่แล้ว

    What's the damages of this ventilator please

  • @bfrancioso
    @bfrancioso 5 ปีที่แล้ว

    The 840 is better