It's sad that a multi-billion dollar company can't get all the details right and it takes guys like Shane to figure out tricks on how to get around them. Shane always has great info on his channel that I learn from!
@@ShaneWelcher oki doki. I am investigating about this with a Panel View 800. It appears that if you are communicating an 800 with a compact 5370 you loose the Email function at the Panel View. Pretty strange.
Hey Shane I love all your content. It has been a great training tool for me. I was wondering if you could do a video on how to replace a kinetix 6500 module and get the parameters downloaded into it from the previous one and any steps that are needed to get it back online.
You would need to manually set up the IP address no matter what. Then if the checkbox for automatic download is check in the version of controllogix then it should prompt the user the allow the download. Hopefully that helps
@@ShaneWelcher yeah definitely. Thank you. I keep getting a " back plane communication" fault on one of the drives on our machine. I am not very familiar with servo drives yet.
Can you share what the IE_VER is for earlier versions like V24? The knowledgebase QA1568 - RSLogix 5000: Converting a Project to a Previous Version doesn't seem to exist
It's basically the same thing I show here, L5K then edit the version to what version you want. If it fails then it will tell you what IE version needs to be used so edit the L5K again and finish the conversion. I believe I have another video on my TH-cam channel that shows earlier versions
Hello, when updating the firmware from V31 to V32 when restoring the L5k project, it restores the program but it does not load the configuration of the input and output cards, cognex cards, how can I export the complete Proyect.
To upgrade the program from V31 to V32 there is no need for an L5k. Just right-click the processor and change versions, make a copy of the program first as a backup.
Look at the error then open it in notepad ++ to get the line number to edit. This will give you an idea of what needs to be changed or corrected. Hope that helps
You have purchase Studio 5000, you can get it from the Rockwell Automation Commerce store online. commerce.rockwellautomation.com/rockwell/en/USD/login
@@ShaneWelcher Sorry, maybe if i rephrase. When version 31 came out the UI changed from the old RSLogix 5000 layout to the new studio 5000 look . Is it possible to have a program on version 31,32, or 33 but use the old UI?
Yes, however it converts the file to version 32. There is a process to convert it back to version 31 using an L5K technique . It's easy to move forward, not so much trying to move backward
@@ShaneWelcher yes I need to convert those files to version 32 but I couldn’t open them to start with with this 32 version software. Is there a way to convert the 31 files without opening the file
@@muufcem8962 you need version 31, open Studio 5000 then open your version 31 file then in the processor setting change the version then allow it to convert it. Either way, you need version 31 if your files are version 31
thanks , I have studio 5000 on my laptop but I dont know what the version of studio 5000 it is , its not letting me connect with my controllers which all have 30.01 or 30.02 , how do I tell what studio 5000 version I have ?
@@rshfn44 open Studio 5000 then go the the help tab then about...that will tell you the version you have. Or you can look at add/remove programs in the Windows install to find if you have multiple versions
@@ShaneWelcher Hi dear, I don't have V31 RSlogix 5000. I received V31 ACD file another person. So, I can't convert the ".L5X". I appreciate to help me. Can I send you this file by mail? After could you back it with V30?
Thanks for the video, totally forgot how to do it after 2 years not doing it.
Thanks for the support
It's sad that a multi-billion dollar company can't get all the details right and it takes guys like Shane to figure out tricks on how to get around them. Shane always has great info on his channel that I learn from!
Thank you
This is awesome! Thank you!
Glad it helped
You are the best 😁 !!!!
Appreciate your comment, glad to help
Great information Shane.
I had another programmer revert a program for me once because I didn't have access to the newer version.
Thank you, glad to hear you got things worked out
@@ShaneWelcher
Hey Shane is it possible to send out email notifications from a Compact Logix?
Or does it have to be done from a Panel View?
@@darthenx2585 Both, however much different setups
@@ShaneWelcher oki doki.
I am investigating about this with a Panel View 800. It appears that if you are communicating an 800 with a compact 5370 you loose the Email function at the Panel View. Pretty strange.
@@darthenx2585 Compactlogix tends to have comms restrictions.
I would recommend a 1756 chassis
Hey Shane I love all your content. It has been a great training tool for me. I was wondering if you could do a video on how to replace a kinetix 6500 module and get the parameters downloaded into it from the previous one and any steps that are needed to get it back online.
You would need to manually set up the IP address no matter what.
Then if the checkbox for automatic download is check in the version of controllogix then it should prompt the user the allow the download.
Hopefully that helps
@@ShaneWelcher yeah definitely. Thank you. I keep getting a " back plane communication" fault on one of the drives on our machine. I am not very familiar with servo drives yet.
@@joshkingery3101 First, capture the Error code then that will lead you to the solution.
Thanks again Shane.
THANK YOU!
Glad I could help
Can you share what the IE_VER is for earlier versions like V24? The knowledgebase QA1568 - RSLogix 5000: Converting a Project to a Previous Version doesn't seem to exist
It's basically the same thing I show here, L5K then edit the version to what version you want.
If it fails then it will tell you what IE version needs to be used so edit the L5K again and finish the conversion.
I believe I have another video on my TH-cam channel that shows earlier versions
Thanks
@@palashabid Welcome
Good video Sir, I don´t know that, excellent
Thank you, hope all is well
Hello, when updating the firmware from V31 to V32 when restoring the L5k project, it restores the program but it does not load the configuration of the input and output cards, cognex cards, how can I export the complete Proyect.
To upgrade the program from V31 to V32 there is no need for an L5k.
Just right-click the processor and change versions, make a copy of the program first as a backup.
I only have v33 in the drop down box. Why?
Probably because that is the only version of emulator you have installed.
Does this work with the L81 processors? I keep getting a fatal error.
Look at the error then open it in notepad ++ to get the line number to edit.
This will give you an idea of what needs to be changed or corrected.
Hope that helps
Hey, which one is the latest version of Studio 5000 and where can I download that?
You have purchase Studio 5000, you can get it from the Rockwell Automation Commerce store online.
commerce.rockwellautomation.com/rockwell/en/USD/login
Hi, thanks for the video,but what is IE.ver- 2.23..which u made it to 22
Just edit fr what is requested, the system will give you the info that needs to fixed
is it possible to use the old layout of RSLogix 5000 on versions 31+?
Yes
@@ShaneWelcher How would i go about doing this ?
@@tristanparker3033 what do you mean? The version change in L5K?
@@ShaneWelcher Sorry, maybe if i rephrase. When version 31 came out the UI changed from the old RSLogix 5000 layout to the new studio 5000 look . Is it possible to have a program on version 31,32, or 33 but use the old UI?
@@tristanparker3033 no, the only thing to do is adjust the colors to match...that's what I do because I am used to RSLogix 5000
Can you open files that were created with version 31 by version 32
Yes, however it converts the file to version 32.
There is a process to convert it back to version 31 using an L5K technique .
It's easy to move forward, not so much trying to move backward
@@ShaneWelcher yes I need to convert those files to version 32 but I couldn’t open them to start with with this 32 version software. Is there a way to convert the 31 files without opening the file
@@muufcem8962 you need version 31, open Studio 5000 then open your version 31 file then in the processor setting change the version then allow it to convert it.
Either way, you need version 31 if your files are version 31
can 28.0 still be downloaded from anywhere
From Ab.com yes
thanks , I have studio 5000 on my laptop but I dont know what the version of studio 5000 it is , its not letting me connect with my controllers which all have 30.01 or 30.02 , how do I tell what studio 5000 version I have ?
@@rshfn44 open Studio 5000 then go the the help tab then about...that will tell you the version you have.
Or you can look at add/remove programs in the Windows install to find if you have multiple versions
It's possible with plantpax4 library
Anything is possible, give it a try
Hi dear,
May I ask help. Please convert my version 31 file to version 30.
Follow the video and do as I show
@@ShaneWelcher Hi dear, I don't have V31 RSlogix 5000. I received V31 ACD file another person. So, I can't convert the ".L5X". I appreciate to help me. Can I send you this file by mail? After could you back it with V30?
@@bayarkhuubachka4757 email me at Shane@OnlinePLCsupport.com
Subscribe: mmini.me/Subscribe-4-Updates
Other socials:
Facebook: facebook.com/OnlinePLCSupport
LinkedIn: www.linkedin.com/in/shane-welcher-sr/