सर,कमर लचक वाली उदाहरण मस्त लगा। आप बहुत खुश होकर हंसा हंसा कर समझाते है। जिससे ठेठ भाषा के जानकार भी तकनीक समझ कर बिना इंजीनियर के भी काम समझ लेते है और ट्रेनी इंजीनियर ,सुपरवाइजर,ठेकेदार भी आसानी से समझ लेते है। दीपक कुमार की दीपक जलती रहे और तकनीकी ज्ञान का प्रकाश फैलता रहे। शुभ अभिवादन।
Ye wala galti 90 Percent ghar me hota hai. Lekin wo sare ghar load bearing aur frame structure ka combination hota hai. Agar brick work nahi hota to 90 % ghar tikega nahi.
Ye kitne floor building ya hall jayega uspr depend krta h Agar 1 hi floor h aur hidden beam diya h to dikkat nhi hogi But without beam kabhi roof slab nhi banana chahiye
Plz can u post video on cost analysis for plastering on aac block, area of 1000sq feet with cement plaster vs ready mix plaster vs pop plaster with thickness in mm, would be very helpful
Sir... Ek coloumn k 6 steel bars me se 2 steel bars me joggle diya h approximately 1.5-2 inches ka aur ye sbhi coloumn me diya h to kya is pr lanter dalna sahi h ya nhi?? Please reply
Hello sir hamara ghr 21x50 ka hai ground floor me piche ventilation ke liye jgha nhi di upr floor me ham ager jgha shud de to koi risk to nhi pls reply sir urgnt
Sir mera ghr bn rha h jisme ek problem ho gyee h jisme foundation k bad pillar ka saria 1foot hi tha jisme mistri n 15 foot ka saria jodker pillar bna diy a h isse kya nuksan hoga or iskavkya solution hoga piz. Btae
Hello Sir,thanks for sharing .i had one question My g+1 was demolished so wanted suggestion if i can go ahead with construction by coupling by making steel rod straight of this column ,plinth beam is not damaged.
Samjhane ka naya tarika bahut achha laga
सर,कमर लचक वाली उदाहरण मस्त लगा।
आप बहुत खुश होकर हंसा हंसा कर समझाते है। जिससे ठेठ भाषा के जानकार भी तकनीक समझ कर बिना इंजीनियर के भी काम समझ लेते है और ट्रेनी इंजीनियर ,सुपरवाइजर,ठेकेदार भी आसानी से समझ लेते है। दीपक कुमार की दीपक जलती रहे और तकनीकी ज्ञान का प्रकाश फैलता रहे। शुभ अभिवादन।
Ohh
Very Nice Information Sir. 🙏🙏
Excellent 👌 information
Bahut acha
Ye wala galti 90 Percent ghar me hota hai.
Lekin wo sare ghar load bearing aur frame structure ka combination hota hai.
Agar brick work nahi hota to 90 % ghar tikega nahi.
right
Nice
Thanks
Sand ki jagah stone dust use krne me fayda h ya nuksaan .please hume bataye with desigh mix m25
Sir Mera 13 by 15 ka hall hai humne usme tie bim diya hai ltk bim nahin diya hai koi problem to nahin hai na future me sir please reply me
Engineer se baat kr lo bhai beam hona chahiye.
Ye kitne floor building ya hall jayega uspr depend krta h
Agar 1 hi floor h aur hidden beam diya h to dikkat nhi hogi
But without beam kabhi roof slab nhi banana chahiye
Sir ek bat btao agr chattt ke lentar pr jaal na dalbaye to koi problem hogi or kis liye jal dalta h
Mene apna comment like Krane k liye ni Kiya tha muje reply to do
Sir mera gate beam k niche pillar k ring7/7hy
Or gate beam ki upor pillar k ring 6/6 hy kya koi problem hoga
Sir pls ans dijea
Mera bhi ek collum joggle Kiya hai lekin sirf 2 inch usse Koi dikkat to Nahin hai na
Dipak ji.... Mera ek drowing banbana thaa....aap drowing banba doge.....? Mujhe aapsehi banbana hai
9by9 inch kolam main kitna sut ka sariya Dena padega
Sir app bahut achhe se samjhate ho
Sir frame structure floor ke bad lintel kaise provide kren kyunki agr bad me wall ke sath lintel or chajja denge toh top me gap 10 mm kaise bachaye
Sir mera bhi 2 Pilar jangal hai jo bim se 4 inch hat kar upar uthaya to 2 manjil ban jayega
Yea Problems hoya hai.
Flat ka picha bali pillar may.
Balaji -1 . Khardaha.
Kalyan Nager. West Bengal.
hmm
Sir Mera plot 50*30 hai
East & South me 20
Feet road hai mene East me main geat rakhna hai house plen chahiye
Nahi krna vo th thik hai . lekin agar ho he gaya th kya kare vo bataye
Wait for destroy 🤡
@@abushahma7787 then u hv fkin knowledge
Problem ka solution bhi batayen.
30×30 Ghar banane ke liye video
Plz can u post video on cost analysis for plastering on aac block, area of 1000sq feet with cement plaster vs ready mix plaster vs pop plaster with thickness in mm, would be very helpful
9by9 inch kolam par kitna majil makan banaya jashkta h
This is meant for indian only. You dont want others to benefit from this
Sir... Ek coloumn k 6 steel bars me se 2 steel bars me joggle diya h approximately 1.5-2 inches ka aur ye sbhi coloumn me diya h to kya is pr lanter dalna sahi h ya nhi??
Please reply
Hi Deepak Sir, i have the same mistake in my house can i talk with you what to do now?
😮😮😮
Hello sir hamara ghr 21x50 ka hai ground floor me piche ventilation ke liye jgha nhi di upr floor me ham ager jgha shud de to koi risk to nhi pls reply sir urgnt
Sir mera pillar me 7/7 ring laga hy or gatebeeam ki upor oh 6/6 ring lagaya hy ...to ab kya kare please bataeya
Sir agar contractor 6"× 9" ka beam cast kre to uske bill me beam RCC 6" or 9" ka hi le ya wo beam 1' ft me Napa jayega
Pls reply 🙏 sir jroori hai
Sir reply to kr dijiye pls
Sir mera bhi 1 column 1inch jugle mara gaya hai......to phir iska samadhan kya hai
Sir, is prakar ki samasya se samadhan vala video upload kariye.... jisase jankari mil sake
600 sqft makan main kitna pilar rahega
Non technical contractor or अनपढ़ मिस्री को समझाना बहुत मुश्किल है, आप के साइट से जाते है वो वही करते हैं जो उसको करना है।
Sahi bole Bhai
Sahi.... bolte hai hum toh 10 saal se kam kr rhe 😂
Yaar kuch jyada hi khichte ho, solution bhi diya karo
Ohh
Sir pilar to phle se hi h lekin ab hmko room aur bra chahiye to hmko yahi na karna padega
Thanks.
10_by_10_by_7 ..panika hoj bananeka keliye ki na kharce atahe
Agar centre line out ho jaye tab kya karein ye bhi toh bataiye...... problem ka solution bhi toh bataiye
6 inch Kollam bhag chuka hai to aap kya Karen chahie
Sir mera ghr bn rha h jisme ek problem ho gyee h jisme foundation k bad pillar ka saria 1foot hi tha jisme mistri n 15 foot ka saria jodker pillar bna diy a h isse kya nuksan hoga or iskavkya solution hoga piz. Btae
Ese thik kese kare
4 inch agar jhuka denge to kya hoga
crack
Bhai esko sahi kaise krna h ye to batao
HOW TO REPAIR?
Sariya jaali main kun bandhate hai
Sir...aapko contact kaise kare ?? Mujhe aapse baat karni hai
Hello Sir,thanks for sharing .i had one question My g+1 was demolished so wanted suggestion if i can go ahead with construction by coupling by making steel rod straight of this column ,plinth beam is not damaged.
Kya hua hta
Maine v ek nakhsa banaya hai aap ek bar check kr lijiye
Agr aisa ho jaye tb kya kre
sidha kare
Solution to diya nhi agar galti ho gai to
ager ek pillar m joggle kr diya ho to kya kre
Sidha kare
@@CivilEngineerDeepakKumar sir caste kr diya h column and uske uper aur ek storey lga Diya gya h
Koi solution nhi h kya ab
And life kya rahegi ab uss column ki
apse bat krnq hqi sir me bhi civil engineer hun
kainse bat hogi sir me job search kr rha
😂😂😂😂😂😂😂
Oh
G Modi sb
ok
Solution kya bhai wo batao
तुम्हारे पास सॉल्यूशन तो होता नही कुछ
Minimum not maximum 1 inch
L
Iska koi upay hai
Aapka nober.
Jagal maar diyaa
brick load utha legi
Sir apka Mobile number milega