Generator kesath vfd ko chala rahe hai to jese hi vfd ko on karte hai generator over voltage ka alarm bata kar band ho ja raha hai isme kya dikat ho sakta hai please bataiye
Mere vfd me ek problem hai 2 wire run command parameter hai vfd start to ho jata hai lekin stop nhi hota frequency zero nhi hoti kam frequency par continues chlta rehta hai, so plz ap kuch bataiye sir
Earthing is a process in which we connect metallic part of equipment to the ground for the safety purpose is called earthing .if you touch any electrical equipment in case of any fault you will get shock to avoid from the shock we should do earthing .
very technical and deep knowledge thanks for sharing
Supar dupar video hai sir
wonderful, very helpful. Thanks for sharing!
Generator kesath vfd ko chala rahe hai to jese hi vfd ko on karte hai generator over voltage ka alarm bata kar band ho ja raha hai isme kya dikat ho sakta hai please bataiye
VFD mai voltage ke parameter check karo
Hello Mr. Joshi
Can you please show us how to make sure VFD is bad or good?
Hello Sir..Very good video.
Pls tell me in case of ext pot used for motor speed control is there any criteria for distance bet the pot and VFD.
Nicely explained
Nice explanation bro thanks bro ❤️
Welcome 👍
Dear sir good evening
Between Earth and Neutral Voltage less than 2 or 4 AC Voltage.
Cont. If the diatance bet ext pot and VFD is more can we still achieve speed control.
Very Good Sir!
very good
sir
Very informative
Mere vfd me ek problem hai 2 wire run
command parameter hai vfd start to ho jata hai lekin stop nhi hota frequency zero nhi hoti kam frequency par continues chlta rehta hai, so plz ap kuch bataiye sir
Sir, VFD ke disadvantage pe video banade
It gives Life to the motor long time soft start soft stop but power factor losses due to vfd
Only one major disadvantages , Cost
Thanks
Hello bro i want run three Phas 10hrs power motor on singal pahas conection wich vff i use and is this safe ?
You can control three phase 220V motor with single phase by using vfd
Sir VFD control wiring video banao
Good 👍
Sir 320 VFD K control connection explain KR den
Hello Sir.. DCS se jab 4mA aa raha hy VFD tab bhi ek speed hota hy.Vfd Ki speed DCS ke 4-20mA output ko propetional nhi hy. Aisa kyu ho rha hy.
Sir plc course is in english please tell me
Bahut Sundar video sar new video kyon nahin banaa rahe
Sir plc analog input in output connection bataye
Drive trip , unbalance
Dovol company ka controller hae kam nai kar raha hey need solution from you
EMotorn ka vfd hia usme high voltage eroor aata hia... 😊
Is single phase vfd available
Hi
Sir load per moter slow chal Rahi hai kya problem hai batana
Ziada rating ki motor use kren. Jo ap use kr rahe wo choti hai load ka hisab sa
Ager apna ziada chalai to jal jaygi motor
Agar gear box hai too oil cq karo
Frequency kam hogi
Meri vfd me frequncy minus me dikha raha hai.Thik nahi ho raha hai.Kya karen?
Bahi 3 phase main 220 v kaise ho skte hai
Sir p1 00 vfd. Soler +grade drive run
Sir ji shakti ka vfd hain 8443 ko password nahi le raha hai
arc inside vfd and big noise short in vfd without load atv32HU75N4 moudle what problem 0
Vfd m Gf kyu aata h or iske kaise tik kre
Motor running fail dhi kara hai sir ji
Three phase ke abb ke vfd ko ksisai chake kare सिंगल फेस sai
Under voltage hokar zero show karta
Bhai meri vfd me LP wala alarm aa raha hai ye kis wajah se aa raha hai
Al 29 Rision
Sir what is earthing !??why it is needed?.
Earthing is a process in which we connect metallic part of equipment to the ground for the safety purpose is called earthing .if you touch any electrical equipment in case of any fault you will get shock to avoid from the shock we should do earthing .
क❤
टङ कर्के आवाज दे राय स्वीच देतेयी यी प्ररावलम कैसै सल्भ करे
एक हीं बात को बार बार बोलता रहा है तुम,
विडियो लंबा करने के लिए।
ये लंबा बकवास हैं