𝗢𝗗𝗠𝗘 𝗺𝗼𝗻𝘁𝗵𝗹𝘆 𝘁𝗲𝘀𝘁 𝗲𝗻𝘁𝗿𝘆 𝗶𝗻 𝗢𝗥𝗕 -𝗜𝗜

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 มิ.ย. 2023
  • ------------------------------
    Paradise Hope by Hotham / hothammusic
    Creative Commons - Attribution 3.0 Unported - CC BY 3.0
    Free Download / Stream: bit.ly/3uteXiN
    Music promoted by Audio Library
    • Paradise Hope - H...
    ------------------------------

ความคิดเห็น • 8

  • @sethsatumir185
    @sethsatumir185 ปีที่แล้ว +1

    Indeed really helpful, waiting for more videos about C/O work.
    Take care, bro
    7 feet

  • @AmitSingh-lz6hr
    @AmitSingh-lz6hr ปีที่แล้ว

    Really helpful content

  • @frateledragos9623
    @frateledragos9623 ปีที่แล้ว

    Very good video, thanks! I have one question. If i want to stop discharging from an oil tank with a Framo pump that is running at 150-200 bars hydraulic pressure, can i close the discharge valve and then lower the pressure and then stop the pump?

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  ปีที่แล้ว +1

      Generally reduce the pump to 60-80 and then u can close discharge valve and then stop pump 150-200 is too high .. although nothing will happen to valve or to pipe but it’s best to avoid such thing

    • @frateledragos9623
      @frateledragos9623 ปีที่แล้ว

      @@atlantianpawanharyana1005 Sir thank you from my heart for the fast reply! nothing will happen to the valve or pipe because immediately as i close the discharge valve i lower the pressure, so there is not much time for any damage to be done?

  • @parpalasebastian3734
    @parpalasebastian3734 11 หลายเดือนก่อน

    Hi. What regulation says that we should make entry in orb 2 about the odme testing?

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  11 หลายเดือนก่อน

      Not sure of the regulation but from ODME we can only de can’t Oil as cargo not any other residue and ORB 2 is for oil tanker carrying oil as cargo

    • @parpalasebastian3734
      @parpalasebastian3734 11 หลายเดือนก่อน

      Ok. I know. I'm chief mate in products tanker. I know how to use and test the ODME. I got a vetting obs that the test was not recorded in the ORB 2. Do u know what regulation stipulates that the test simultation and annual calibration must be recorded in the ORB 2? I couldn't find anything.