Mixing valves

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 ธ.ค. 2024

ความคิดเห็น • 15

  • @deanchapple1
    @deanchapple1 2 ปีที่แล้ว +1

    Mind blowing!! 🤯😵‍💫

  • @normanboyes4983
    @normanboyes4983 2 ปีที่แล้ว +1

    Good stuff.👍

  • @wayneh150
    @wayneh150 10 หลายเดือนก่อน +1

    I normally see ufh systems with a mechanical mixing valve.
    And a zone valve that pulls in the ufh when one of the room stays calls.
    How and why is it better to have a belimo valve mixing the return from the manifold.
    There are three sensors, flow return and floor.
    I would like to understand how this sort of set up works and why we want this?
    I can use just the one sensor to mix to setpoint on flow, but I have the return sensor and the floor sensor spare.?
    Have you done or seen this sort of control before?

    • @andrewmillwardwatford9410
      @andrewmillwardwatford9410  10 หลายเดือนก่อน

      This is for a weather compensated system. The idea is that the boiler runs at it's very minimum temperature at all times to maximise efficiency. Also while providing the perfect temperature of water the gift perfect room temperature in total comfort to the user. The systems you're referring to are what we call high temperature systems where the boiler runs at high temperature and lower efficiency. The water is sent to the emitters at a higher temperature than is required and causes the room to overheat turning off a room thermostat. Thermostat turns off the supply to the room until the room gets too cold when it will turn it back on again. The difference between this overheating and under heating is called the hysteresis. The smallest resist the better the comfort. The compensate for the discomfort caused by a white history people run the heating systems about 1 degree hotter than they need to leading to further inefficiencies.

  • @Jimmynoglue
    @Jimmynoglue 3 ปีที่แล้ว +2

    That’s a Rolls Royce install mr Millward, I however can’t get my head round a underfloor heating system running effectively At 25c? Does the room get warm enough with that low a temp? Thanks in advance Myles.

    • @andrewmillwardwatford9410
      @andrewmillwardwatford9410  3 ปีที่แล้ว

      Yes its perfectly adequate in some buildings with the correct pipe spacings at the correct outside temperature. As it gets colder outside the flow temperature rises.

  • @markturner503
    @markturner503 9 หลายเดือนก่อน +1

    Hi Andrew.. can you tell me why your using a plate he ?.. is it because the boiler cant supply the flow rate required?

    • @andrewmillwardwatford9410
      @andrewmillwardwatford9410  9 หลายเดือนก่อน

      A plate heat exchanger can provide hydraulic separation and offers total isolation from the system water. The main reason for using a plate heat exchanger is to protect the boiler from contaminated system water

  • @igorchuchro4991
    @igorchuchro4991 3 ปีที่แล้ว +2

    What's the model of this viessmann. i see many people installing viessmann over worcester and vaillant

  • @igorchuchro4991
    @igorchuchro4991 3 ปีที่แล้ว +1

    Wow that's impressing

  • @garymarshalsey6599
    @garymarshalsey6599 2 ปีที่แล้ว +1

    Hello Andrew. Another great video. Can I ask the make of your mixing valve?