Very nice video. At 7:10, just remember that starting load is more than stable operating load, so check the amp draw after 5 min in case of an AC so that the system has come to a stable operation. This will be very challenging in case of inverter AC as its power draw will constantly be changing. My question here is what would you take as normal power draw in case of an inverter AC? It can be the average of its max vs min power draw.
thank you so much. No need to add a capacitor with Inverter AC . because the inverter Kit already modifying and optimizing the waveform to get maximum efficiency.
nice video, brother mere ghar Ziewnic inverter laga hua ha jab ghar ka load batteries per ayta ha tu ghar ke fans 80 watts ke bajye 130 watts lyna start karte hain iska kia hal ha?
Great brother, Ma ne apki madad se Apni donkey water pump motor ka voltage ampere 4.1 vamp se 1.90 tak Kam Kia ha, Or wattage bhi Kam ho gae hai, Sab se bath Kar ap foran response krtay hai Thnks too much
Excellent video indeed! I have enjoyed this learning. Your way of teaching is superb. I appreciate it a lot. Please keep it up. Stay blessed. Secondly, in this video, for conversion of KVAR into microF, 314xvoltage squared is mentioned in the denominator. What is 314? The value of Pi is 3.14. Please clarify it. Thirdly, a Mitsubishi inverter (1.5 Ton) AC shows PF=0.78. It is leading to a higher electricity bill. How can we improve the PF? Given: PF: 0.78 Voltage=238 volts Running Current: 7.77 Amps. Rated Current: 8.25 Amps. Frequency: 50Hz Connection type: Single Phase. What type of capacitor would you recommend to correct the lagging PF to 0.95? I shall be obliged for your guidance.
Plz mentioned site liñk for calculation of 3 phase power factor. I have pf .5- .6 of ground floor & .8- .9 of 1st floor of my house. Plz advise me to improve those power factors Thanx
Improving power factor will not reduce the active power, ie the actual power, from the formula itself you can see. It effects on this current draw n in the lines.
Your juice example is very good sir...It is easy to understand...Sir thank u... Sir I have a doubt....Please Clarify... If any load in circuit line cable and neutral cable should take in equal length of two wires sir...If we take positive wire 3 meters and neutral wire 1 metre take it effect ampers sir...Just asking for general knowledge sir... Please tell me
@@Technifyi_eng bhai main soudia men hon idhr electrical 60 hz hy or pakistan men 50 hy agr idhr sy koi electrical iteam mean a.c send kron to kya wo odhr chaly ga.
@@Technifyi_eng Hello, Thank you very much about your information video! I just want to ask you about my gas boiler which is 2.4 kW, 220v, what is correct capacitor? I think may be is 40 mf? Thank you very much!
Bhai acche information the but connection kese krna he ose kese used me lana hain jis bhi appliance pr laga he ti ose kese lagana he ap os bare me bhi zara details main bataye take sb kucb krne ke bad apply krne me problem na ho hame please
How about source voltage 80 in house meaning under voltage 5kw used needed to function all like washing machine,ref,tv,lightings,how many capacitor used and what type of capacitor
Sawal voltage ka hai before or after after voltages nahi btaaen my frnd told me ke jub kelectric ki tarf se voltages down hoten hain to appliances current ziada khench tin hain capacitor lagane se voltages barh jaten hain islie current kum hojata hai Correct me if I am wrong kiunke capacitor lagane se voltages barhne ke practical mene dekha hai
you are right Mr Mirza k capacitor lgane se voltage barh jaty hain. but Actually Capacitor lgane se Power Factor barh jata hy, power factor barhne se Current kam ho jata hy aur Current kam hone se line me hone waly voltage drop b kam ho jaty hain , as a result load pe milne waly voltage barh jaty hain.
bhai 20 HP ki three pase motor keliye kitna capacitor chahiye hoga hamara bill buhat zyada ata hai atta chakki ka voltage sardi me 400 aur gharmi me 300 ya 250 tak ajata hai !
Sir my 3 phase moter is 125 hp ki hy aur tubewell ki hy to kia unit kam ho sakty hi load 125 amper hy 420 volt py aur 78 unit per hour consume kar rahi hy
asalmualikum nice work and good way to explain.can u please tell me what is the common name for auto power factor correction device and where to find it .thanks plz
Wa alikum slam, thanks dear. The common name of the device is " Power Factor Controller". See detail on the below link. www.se.com/ww/en/product/51213/varlogic-pf-controller-rt12-step-440v/
My dear you can't be reduce your electricity bill with approving power factors because electricity bill only calculate with wattage..... Not with amps..... Power factor can improve the efficiency of motor or improve the quality of voltage but it will not decrease the amount of electricity bill.... Please check it with practical experiment... And please please reply to me.. Thank you.........m
Dear , You know the term losses? Low power factor leads more losses. And you know losses act as load(KW). I hope you get the point.. And in industrial energy bills, Kvar/h also charged separately.
السلام و علیکم ورحمتہ اللہْ بھائی جان میری فیکٹری کا پاور فیکٹر سب پر کم نہی ہوتا لیکن چند موٹر پر کم ہوجاتا ہے اسکے لیے میں لائن میں کپیستر لگا سکتے ہیں
Brother, ap ko estimated load ka to pta he ho ga k kitna hy. Specially motor load. Power Factor correction panel install kren jis me ek se zeyada kvar capacitor lgy ho. Zrurat prny pe capacitor ko on or off kkeya ja skta ho. Auto controller ki madad se automatic capacitor on off ho skty hain
Meri samaj se laga sakte hai, par auto power factor correction panel ke saat. Agar aap Ka load Kam ho Jaye to automatically capacitor bhi Kam ho Jaye. Overall leading power factor se bhi bachna hai.
Pls do make fool of ppl. There is no impact of Power factor on domestic consumer as they are being charged on KWH not KVA. This impact only commercial consumer as distribution companies penalize them on the basis of low Power factor.
Dear, is there any thing wrong that i have explained about power factor? I never said that A house hold can reduce bill then the normal bill, but it effects the electricity bill really. Think about all the aspects. And commercial consumer charged in KWH and KVARH both. KVARH totally depends on power factor.
السلام علیکم۔ طیب صاحب آپ نے مسلے کو بہت خوبصورتی کے ساتھ حل کیا ہے۔ جزاک اللہ۔
Valueable & helpful information
But only electrical know how people will understand .
You deserve a thumbs up bhai
Such an educated person.briliant
Thank you so much dear
Bohut bdiyaa sir kamal Ka knowledge thi thanku ❤️
Beautifully explained.thanks
Thanks and welcome
Aslam u alikum bhai
Boht boht shukria.
Acha explain kiya apnay
thanks.
Very nice video. At 7:10, just remember that starting load is more than stable operating load, so check the amp draw after 5 min in case of an AC so that the system has come to a stable operation. This will be very challenging in case of inverter AC as its power draw will constantly be changing. My question here is what would you take as normal power draw in case of an inverter AC? It can be the average of its max vs min power draw.
thank you so much.
No need to add a capacitor with Inverter AC . because the inverter Kit already modifying and optimizing the waveform to get maximum efficiency.
@@Technifyi_eng sir apna wats no da
nice video, brother mere ghar Ziewnic inverter laga hua ha jab ghar ka load batteries per ayta ha tu ghar ke fans 80 watts ke bajye 130 watts lyna start karte hain iska kia hal ha?
Thanks for your program
Very nice explaination brother.Thanks
Great brother,
Ma ne apki madad se Apni donkey water pump motor ka voltage ampere 4.1 vamp se 1.90 tak Kam Kia ha,
Or wattage bhi Kam ho gae hai,
Sab se bath Kar ap foran response krtay hai
Thnks too much
Excellent video indeed! I have enjoyed this learning. Your way of teaching is superb. I appreciate it a lot. Please keep it up. Stay blessed.
Secondly, in this video, for conversion of KVAR into microF, 314xvoltage squared is mentioned in the denominator. What is 314? The value of Pi is 3.14. Please clarify it.
Thirdly, a Mitsubishi inverter (1.5 Ton) AC shows PF=0.78. It is leading to a higher electricity bill. How can we improve the PF?
Given:
PF: 0.78
Voltage=238 volts
Running Current: 7.77 Amps.
Rated Current: 8.25 Amps.
Frequency: 50Hz
Connection type: Single Phase.
What type of capacitor would you recommend to correct the lagging PF to 0.95?
I shall be obliged for your guidance.
Plz mentioned site liñk for calculation of 3 phase power factor.
I have pf .5- .6 of ground floor & .8- .9 of 1st floor of my house.
Plz advise me to improve those power factors
Thanx
I really liked the video lecture method
Thanks l got knowledge of pf good way
Bhai Jan Vfd invetar k?.aor is kia Kam h.kia y bajle bachat krta. Kasy plz
Very good explanation brother.
Thank you so much bro.
Zabardas good 👍
i)4 ceiling fans
ii)1 motor(bor)
iii))lahori colar
iv)6 energy saver25watts
V) fridge middle size
Please calculate the value of capacitor
nice explanation
❤ MashAllah dear friend thanks 👍
Always welcome
Thank you!
Please educate us on effect of frequency (50Hz) change effect on connected inductive load
Good job . Thankyou sir
Nice. Congratulations.
Thank you! Cheers!
Good job
Nice good , very clear how power factor work
Thanks
True and complete.......
Thank you.
Huge respect for you
Thanks dear
Great way to explain
Thanks
Sir capester ko socket main lga skty hain r socket ko on krny sy kaam kry ga plz sir ans zaroor dijye ga
Improving power factor will not reduce the active power, ie the actual power, from the formula itself you can see. It effects on this current draw n in the lines.
Valuable information 👌
Thank you so much.
Thank you sir very informative video
Good man 👍
Thank you so much
Go on
Great sir G
Vi hamara motor 3 hp 2.2kw submersible . 220 volt . How many micro farad capacitor it's need for power factor .
Thanks for information
Nice info thanks bro
Please what capacitance can be used for 240V to improve power factor?
what is the load you are using ?
Refrigerator, cooker, iron, home theater,...etc. Including lighting circuit
Your juice example is very good sir...It is easy to understand...Sir thank u...
Sir I have a doubt....Please Clarify...
If any load in circuit line cable and neutral cable should take in equal length of two wires sir...If we take positive wire 3 meters and neutral wire 1 metre take it effect ampers sir...Just asking for general knowledge sir... Please tell me
Thanks Ramya.
And Answer of Your Question is; we can Use different length of Neutral and Line Wires, it will not effect Amperes of circuit.
@@Technifyi_eng bhai main soudia men hon idhr electrical 60 hz hy or pakistan men 50 hy agr idhr sy koi electrical iteam mean a.c send kron to kya wo odhr chaly ga.
@@Technifyi_eng
Hello,
Thank you very much about your information video!
I just want to ask you about my gas boiler which is 2.4 kW, 220v, what is correct capacitor?
I think may be is 40 mf?
Thank you very much!
Very nice explanation
Thanks dear
Well explained
Nice & super
Is we can use this with our ups? Please guide us.
Bhai acche information the but connection kese krna he ose kese used me lana hain jis bhi appliance pr laga he ti ose kese lagana he ap os bare me bhi zara details main bataye take sb kucb krne ke bad apply krne me problem na ho hame please
sir g very great
Nice sir g
How about source voltage 80 in house meaning under voltage 5kw used needed to function all like washing machine,ref,tv,lightings,how many capacitor used and what type of capacitor
Sawal voltage ka hai before or after after voltages nahi btaaen my frnd told me ke jub kelectric ki tarf se voltages down hoten hain to appliances current ziada khench tin hain capacitor lagane se voltages barh jaten hain islie current kum hojata hai
Correct me if I am wrong kiunke capacitor lagane se voltages barhne ke practical mene dekha hai
you are right Mr Mirza k capacitor lgane se voltage barh jaty hain. but Actually Capacitor lgane se Power Factor barh jata hy, power factor barhne se Current kam ho jata hy aur Current kam hone se line me hone waly voltage drop b kam ho jaty hain , as a result load pe milne waly voltage barh jaty hain.
Sir mujy unit calculate krny hani
Load hy 1000 Amp
P.f 500 KVAr
Tu ktny units bachy gy
Agr p.f na lgao tu ktny units zaia hon gy
AOA Bhai hum her cheez ka Alag Alag power fector kaise check ker sakty Hain koi asaan tariqa Bata den. Takeh hum us k mutabiq capestor Laga saken.
Thanks a lot brother
20 h/p ki motor k st kitne A ka power factor lgana chahey 3 phase
bhai 20 HP ki three pase motor keliye kitna capacitor chahiye hoga hamara bill buhat zyada ata hai atta chakki ka voltage sardi me 400 aur gharmi me 300 ya 250 tak ajata hai !
Sir my 3 phase moter is 125 hp ki hy aur tubewell ki hy to kia unit kam ho sakty hi load 125 amper hy 420 volt py aur 78 unit per hour consume kar rahi hy
Han bos kuch kara apny bil kam krny k liye
Dear boss, please guide me which capcitor should be used for a single phase sealing fan 150 watt and voltages are 180v
bhi 1 ampir la ga
Good
Yh legal hy na.
Dosray 1.5 ton split ac mn bhi lag sakta hy
Sir ye legal hy, es k through losses km ho jaty hain bs.
Bhi meter three face hai magar motor single face hai aur load gir jata hai
Nice yar
Bhi power factor mra 0.5 ha konsa capcitor lgy ga bhtr krny ka liye
Ma na dc fan lgya ha
Maa sha allah
1kw single phage me kitna uf ka capister lagana hoga abhi pf 0.78 hai
Sir 20HP ki motor 23 Amper use kr rahi h * ** Kon sa capestor use kary
20hp ki motor k 23Amp. Normal hain. 400V pr.
Capacitor ki zrurat nai hy.
Agr 23 se zeyada le to pher capacitor lgana pry ga.
Voltage kitne aa ry hain?
asalmualikum nice work and good way to explain.can u please tell me what is the common name for auto power factor correction device and where to find it .thanks plz
Wa alikum slam, thanks dear.
The common name of the device is " Power Factor Controller".
See detail on the below link.
www.se.com/ww/en/product/51213/varlogic-pf-controller-rt12-step-440v/
سر کیا اپنے اے سی کے ساتھ کیپیسٹر لگا سکتا ھوں sir can I use capacitor with my DC inverter air conditioner
no dear. no need capacitor with dc inverter AC
Good sir
سینگل فیس پر 1.50 ٹن AC اور ڈبل بیرل پمپ کے لیۓ کتنی ویلو کا کپیسٹر لگانا چاھیے ؟
Bhai 5 kw load k lite kitane mfd ka capacitor lagana padega
Amps kitny le ra load?
2kw pr ketne ka kapctr lagega
Sallam.. plz guide me for 3 phase moter... New meter is running very fast i want to reduce my electric bill plz help me sir
Wa alikum slam!, Can you please give me the detail of load you are using?
20 ki motor par kaun sa capacitor lagega
My dear you can't be reduce your electricity bill with approving power factors because electricity bill only calculate with wattage.....
Not with amps.....
Power factor can improve the efficiency of motor or improve the quality of voltage but it will not decrease the amount of electricity bill....
Please check it with practical experiment...
And please please reply to me..
Thank you.........m
Dear , You know the term losses?
Low power factor leads more losses. And you know losses act as load(KW).
I hope you get the point..
And in industrial energy bills, Kvar/h also charged separately.
Can you explain it with video experiment.........please
@@maneerahmad1955 i will do.
@@Technifyi_engi am waiting for that
Thank you my dear......
V v nice
Thanks
lal pump shahzad ka 6.5 amp per kon sa capacitor Laguna hy
Agr Pump ki motor 1KW ki hy aur 6.5 Amps le ri hy then use 26uF capacitor for Power Factor Improvement.
single phase small welding machine keliye kitna uf ka or kitna volt ka capacitor lagana padega
buhat acha laga
تھری فیز 10 ہارس پاور کی موٹر پر کونسا کپیسٹر لگانا چاہیے
1.5 ٹن A/C کے لیۓ کتنے u/f کا کپسٹر ھونا چاھیے؟
Mera metar 2wat hai mujhe kitne wat ka cepister lagwana hai please halp me
sir ap ka load kya hy aur kitna hy?
👍👍👍👍👍👍👍
Thank yuo
السلام و علیکم ورحمتہ اللہْ
بھائی جان میری فیکٹری کا پاور فیکٹر سب پر کم نہی ہوتا لیکن چند موٹر پر کم ہوجاتا ہے اسکے لیے میں لائن میں کپیستر لگا سکتے ہیں
Ge lga skty hain..
جناب مجھے اور ایک شک ہے ، میں فیکٹری میں بجلی کی نئی وائرنگ کرتے وقت پہلے سے k.v.a.r کا انتخاب کیسے کروں؟
Brother, ap ko estimated load ka to pta he ho ga k kitna hy.
Specially motor load.
Power Factor correction panel install kren jis me ek se zeyada kvar capacitor lgy ho. Zrurat prny pe capacitor ko on or off kkeya ja skta ho.
Auto controller ki madad se automatic capacitor on off ho skty hain
@@Technifyi_eng thank you sir
Example total 3ph motor load 67kw then 1ph motor 15 kw and lighting load 5 kw
Is load ku kythini kvar dalna hea
Plz sent me link Jo ap bataya tha who show nahi ho raha
Sir Excel sheet not available.
Check Please, its available
Sir mera 1 swal hy k kya hm ghr ka total ampere calculate kr k ksy bhi switch board my capacitor lga skty hy?
Yes lga skty hain
Meri samaj se laga sakte hai, par auto power factor correction panel ke saat. Agar aap Ka load Kam ho Jaye to automatically capacitor bhi Kam ho Jaye. Overall leading power factor se bhi bachna hai.
Sir 6 kilo vat par Kon sa lagy ga
dear Sir Pl....share Excel sheet
Very great
couldn't get that excell sheet!
I have checked, the link is working.
سرپاور فیکٹر کی ایک تفصیلی ویڈیو بنانا
Aslmlakom bhie mja ipka smjinaka trek pisndhi ok alia hipej
Thanks❤
فائل پاور فیکٹر
Single phase welding machine keliye kitna mfd Or kitna volt ka capacitor lagana padega
Tanks
Well
اسلام وعلیکم سر آپ سے 100 کیلوواٹ پاور فیکٹر کی معلومات لینا چاہتا ھو
وعلیکم السلام۔ جی آپ کو جو انفارمیشن چاہیئے آپ پوچھ سکتے ہیں۔
Pls do make fool of ppl. There is no impact of Power factor on domestic consumer as they are being charged on KWH not KVA. This impact only commercial consumer as distribution companies penalize them on the basis of low Power factor.
Dear, is there any thing wrong that i have explained about power factor?
I never said that A house hold can reduce bill then the normal bill, but it effects the electricity bill really.
Think about all the aspects.
And commercial consumer charged in KWH and KVARH both. KVARH totally depends on power factor.
Power factor 1 sa ooper na ja sakta
10 ki power 6 hoti hai formula mien
Dear ye formula modified hy... Single step calculation k leye hy. Es me 10^9 hi ay ga....
💛🖤