Installing an Engineered Septic System (Time Lapse)

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 มิ.ย. 2024
  • Installing an Engineered Septic System
    Watch from excavation to placement and cover up as Peak DirtWorks installs an Engineered Septic System, including 2-compartment tank with 3rd 500-gallon dosing compartment and engineered leach field with sand filter.
    .
    Septic System Install Time-Lapse Timestamp
    Chapters:
    00:00 Demo Existing Outhouse
    00:34 Excavation Of Septic Leach Field
    01:26 C33 Septic/Concrete Sand Delivered/Installed
    02:05 Building a Septic Leach Field
    02:52 Excavation for Septic Tank
    03:05 Septic Tank Delivery/Tank placement with Crane Truck
    03:18 Testing Septic System For Inspection
    03:29 Covering Septic Tank Leach Field
    03:50 Completed Septic System
    .
    Location: Woodland Park - Teller County, CO.
    .
    Peak DirtWorks
    ⭐⭐⭐⭐⭐ 𝟱-𝗦𝘁𝗮𝗿 𝗥𝗮𝘁𝗲𝗱
    Grading/Excavation, Concrete, & Septic System Installation
    Locally owned and operated out of Woodland Park, CO. Servicing Teller County & Surrounding Areas. www.peakdirtworks.com
    .
    #septic #engineeredseptic #septicsystem #Septicinstallation #septicinstaller #constructionlife
  • บันเทิง

ความคิดเห็น • 115

  • @iamthemoss
    @iamthemoss 2 ปีที่แล้ว +1

    Great video, we're in north Alabama, we have clay that is essentially potters clay.

  • @robertonascimento8002
    @robertonascimento8002 2 ปีที่แล้ว +5

    A ideia é ótima,só que não temos essa tecnologia no Brasil 👍🇧🇷

  • @sikazwejerry4620
    @sikazwejerry4620 9 หลายเดือนก่อน

    Congratulations

  • @alexdean2575
    @alexdean2575 2 ปีที่แล้ว

    Cool tunes

  • @user-st6mo7xj2d
    @user-st6mo7xj2d 2 ปีที่แล้ว +2

    Смотрю и по-хорошему завидую. Всё правильно , качественно и на долгие годы.

    • @Oleg-bl2wy
      @Oleg-bl2wy 2 ปีที่แล้ว

      астра юнилос без откачки и запаха.и будет вам счастье)))

    • @user-st6mo7xj2d
      @user-st6mo7xj2d 2 ปีที่แล้ว

      @@Oleg-bl2wy ну как же без откачки , раз в год без вариантов.

    • @Oleg-bl2wy
      @Oleg-bl2wy 2 ปีที่แล้ว +1

      @@user-st6mo7xj2d без откачки.гугл в помощь...там выброс очищенной воды .очистка до 98 проц..мама дренажную трубу вывела в цветник на лето.соседи вывели на газон...раз в год внутри моешь керхером.и все..и порошки стиральные подбираешь малопенные..септиков подобных-много..лет 20 уж как..яма глубиной 2.5 метра.и квадратом 1.5 на 1.5 места...и все..у нас коттеджный поселок 400 дворов.никто не жаловался.в соседнем поселке тоже.по 2 штуки ставят.на дом и баню.дома по 500 метров..по 5-7 человек одновременно живут..

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      Here in the US, you would get in big trouble with the environmental health agencies. Essentially it's still going into the ground with these systems, but it has to be 100' away from a well, etc.

    • @Oleg-bl2wy
      @Oleg-bl2wy 2 ปีที่แล้ว

      @@ConstructionVideos in Russia, these septic tanks are certified. no problems .. why does a private house need a well? a well of 80 meters solves all issues.

  • @franciscowashington2155
    @franciscowashington2155 2 ปีที่แล้ว +2

    Beleza muito bom 👍👍😎

  • @TheIggypop1
    @TheIggypop1 2 ปีที่แล้ว

    Hole with a bucket nice

  • @domingodelarosa485
    @domingodelarosa485 8 หลายเดือนก่อน

    very good your septik tangk leak water

    • @ConstructionVideos
      @ConstructionVideos  8 หลายเดือนก่อน

      It does not leak water. The solids are separated from liquid into the 2nd compartment, and the effluent goes into the 3rd compartment where it is dosed all at once to the leach field where you can see it sprays evenly into all of the infiltrators and is filtered through the sand bed and into the ground.

  • @jhayward1940
    @jhayward1940 2 ปีที่แล้ว +6

    Pretty good system there. Better than dumping it off the hill somewhere.

  • @777interesting
    @777interesting 2 ปีที่แล้ว +2

    Ever seen such overkill and destruction for septic water ……….good luck, cheers from Australia

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      We are required in most cases to do some reclamation. We bring in top soil with organics, or will recover it with the organics we scraped off so that it quickly grows back over the new system.

  • @williambryant5946
    @williambryant5946 2 ปีที่แล้ว

    First time seeing one of your videos. I have a few questions. I'm somewhat familiar with the chamber system for the leach field but not with the small PVC pipe down the middle. I assume it has holes in it for the water to drip from but why is it needed instead of just stopping the pipe where it enters the chambers? I put in a single line of chamber system to extending my septic system leach field but I stopped the pipe just inside the chamber so the water could just fill the chamber how it wanted to. Wasn't told about a pipe down the middle. I'm in NC if that makes any difference. Did I do it wrong? It hasn't caused any problems that I'm aware of and it's been 2 years now. System is working better than before. Ok now what I'm wonder is where y'all are located because the ground looks like your digging in a gravel pile? Is it gravel that I'm seeing? Will grass grow in that type of soil/material? The septic system looks very professionally done. Guessing y'all have done it a couple times before this one. The little bit of grading y'all had to do made the yard look a lot better too. Very nice job. Great video. Stay well. -Wil 👍

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      Thanks for the comment! To answer your questions, this is a pressurized dosing system. The laterals running through the infiltrators have holes every x-amount of inches and when the septic tank fills up enough, it doses 180-gallons all at once, unlike the drip systems of yesteryears. When it doses all at once like that, the head pressure allows for the effluent to spray through the holes evenly all down the line and throughout each row of infiltrators at the same rate. This is different from the non-engineered trench systems that simply pour into the leach field chambers. From what I understand from the Engineer, the native soils perk too well, which is why we have to bring in the sand filter to slow the absorption and allow the necessary treatment to happen evenly throughout the entire length of the field all at the same time. I am not sure if it is a state or county regulatory deal, but here in Colorado, and more specifically in Teller County, probably 90% of the systems are engineered in this way. Many of the older systems are the usual trench with maybe 1 or 2 serial connections to additional trenches. Here where we work, a septic system has to be inspected prior to the sale of a home, so we are often called in when the inspection shows a failing leach field. In order to replace, an Engineer has to come to a soil test and ultimately design a new leach field, so we've seen a lot of these older type of systems replaced with the newer Engineered designs.

    • @williambryant5946
      @williambryant5946 2 ปีที่แล้ว

      @@ConstructionVideos Thanks!

  • @joe7842
    @joe7842 2 ปีที่แล้ว +2

    I like where it reduces from the main line, guessing 110mm straight down to 65mm? Instant blockage point, then another at the t intersection.
    One way to push shit back up hill 👍

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      This is treated effluent with no solids, so it's no issue at all. It is a dosing pressurized system.

    • @joe7842
      @joe7842 2 ปีที่แล้ว

      @@ConstructionVideos 👍

  • @hmstjohn6236
    @hmstjohn6236 2 ปีที่แล้ว +1

    Will you work out near Antero Reservoir off hwy 24 to install a septic system?

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      Hey there! We do work in Park County. Feel free to email us to discuss- info@peakdirtworks.com

  • @user-yh5mj6ih5l
    @user-yh5mj6ih5l 2 ปีที่แล้ว +3

    Ничего не понятно,но оооочень интересно!

  • @Flapswgm
    @Flapswgm 2 ปีที่แล้ว +1

    This looks like an infiltrator system and to my knowledge, the inlet pipe only goes into the FIRST arch about 8 inches. The rest of the field has NO pipes running through them.
    The risers at each end are supposed to by cut into the riser portion of the arch. Check it out.

    • @cab3910
      @cab3910 2 ปีที่แล้ว

      Yeah I'm with you. I don't understand this system either

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      This is an Engineered pressurized dosing system with a sand bed. The laterals within the infiltrators have a series of holes drilled in the pipe. When the 2-compartment tank fills up into the 3rd compartment high enough, a dosing siphon in the 3rd compartment is triggered and the system doses (approx. 180-gallons at a time). It is like a fountain inside the infiltrator, spraying evenly throughout the bed. Our non-engineered systems work as you describe. For those, the effluent drains from the tank into a distribution box that evenly distributes the effluent into trenches that have the infiltrators but no laterals. 95% of the systems here in the region are Engineered due to the soil conditions. We have very rocky, decomposed granite soils that actually absorb too well, thus not allowing the effluent to be treated effectively before going into the ground. Because of this, for Engineered systems, we have to over dig the leach field and fill it with 2-3' of special (read expensive) sand, then build the laterals overtop of the sand bed as seen in the video. We don't Engineer the systems, we simply install per the Engineer's design. The determination of whether or not an Engineered system is required is made by the Engineer upon inspection of the test holes that we dig. It all depends on the LTAR (Long-Term Acceptance Rate) of the soil.

    • @cbr1krr371
      @cbr1krr371 2 ปีที่แล้ว

      It’s kind like a LPP but it’s cool I’ve never seen chambers so close but that a cool way

  • @squeekhobby4571
    @squeekhobby4571 2 ปีที่แล้ว +1

    Excellent! What is the ballpark cost?

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      A system like this averages in the 18-22k range, depending on whether or not a pump is required. If there is not enough fall for a gravity-fed dosing siphon, like this one, then the pump adds approx. $2750 in additional materials.

    • @squeekhobby4571
      @squeekhobby4571 2 ปีที่แล้ว

      @@ConstructionVideos : thanks!

  • @Flapswgm
    @Flapswgm 2 ปีที่แล้ว +4

    Also, the TOP of the arch should be no more than 4' from the finished soil.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      Per the Engineer's design, the system has a minimum 1', maximum 3' coverage over the top of the infiltrator.

  • @Jefleopard
    @Jefleopard 2 ปีที่แล้ว +4

    It looked like 2” pipe in the leach field. Why not 3”? 2” seems too small.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +6

      The more modern dosing systems use 1.5-2" laterals in order to pressurize the system and spray the effluent evenly across the leach field. This has a 3-compartment tank with a dosing siphon. When that 3rd compartment fills up, the system dumps the contents. Each dose is approx. 180-gallons and it is literally like the Bellagio fountain inside spraying within the chambers and evenly distributing the effluent. Very different than the older "drip" systems, which are uncommon here in our County with the decomposed granite soils. Great question!

  • @jeffreyboarman4032
    @jeffreyboarman4032 2 ปีที่แล้ว

    Sing Melody songs while you work

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      Did you watch to the very very end? =) Snuck one in there! I wonder what others would be acceptable for public use?

  • @vincebarton5118
    @vincebarton5118 2 ปีที่แล้ว

    Yea good luck with that hole system

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      This is how the majority of septic systems are designed in this region. We simply install the Engineer’s design.

  • @jonurton7826
    @jonurton7826 2 ปีที่แล้ว +2

    I live in northern Canada and this system does not work unfortunately

  • @nobleroofinggeneralcontrac7961
    @nobleroofinggeneralcontrac7961 2 ปีที่แล้ว +2

    All of that for a 3 bedroom ranch home? In good soil. Looks like over kill and I use to install them in Taxachusetts a very heavily regulated state where the cities and towns have their own Boards of health. In the town of Littleton MA for example they subbed out their BOH but the regulations are written by the board members at the time and they were not Civil engineers but rather folks that resisted new building in town. They made things very difficult. They would require.... 4 passing perk test 2 in the primary area and two in the reserve area... They required a 10ft deep hole to determine high ground water. That determination set the bottom of the leaching pipe 5ft above that. There are some homes that had systems in the front yard and from the street you could only see the roof of the home. Ridiculous. To boot you could only use approved sand. What state is this in? Nice work.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      1-bedroom 😬
      It is pretty crazy out here. I am sure someone lobbied someone. Here, we have to dig 8' test holes and then the Engineer determines the soil type which determines whether or not it needs an Engineered system. 99% of the time here, with the crushed granite and/or clay soils, it has to be Engineered like this with the sand filter and pressurized dosing system. When the soil it optimal and does not require an Engineered system, we create the design based on the LTAR and design flow. When it's a non-Engineered system, it is just a trench system with a distribution box and the effluent pours into the chambers with no laterals. It's the Engineered systems like this one that are so involved.

  • @dirttdude
    @dirttdude 2 ปีที่แล้ว +5

    i have never seen a drain field like that in my life

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      Pretty involved huh? This is how the majority of systems are Engineered in this region. A lot different than 10 years ago!

    • @cab3910
      @cab3910 2 ปีที่แล้ว

      @@ConstructionVideos so why does the pvc run all the way through your chambers. I've never installed one like yall did but have recently installed several. Also whats up with the water spewing out for the end ball valves. That would be sewage spewing when time. This system is different than all the ones I have installed

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      @@cab3910 The water spewing is just a way for the Engineer to verify that there is the correct amount of fall from the tank to the leach field. The water had to spray a certain height to show that the head pressure was acceptable. It is also a way to flush the system after everything is connected and glued to ensure the laterals will be cleared of debris/plastic shavings, etc and ready to function as designed. After the test is performed, the valves are turned off and covered with a Sprinkler-type valve box cover so it can be accessed later, if necessary.

    • @jpmonin7429
      @jpmonin7429 2 ปีที่แล้ว

      @@ConstructionVideos that doesn't make any sense. How would the water spewing out show how much pitch the pipe has? And Ur dwv system shouldnt be under head pressure after testing. Unless a stoppage occurs. We test with a 5' riser topped off with water but that only shows no leaks and that the system can handle maximum capacity and pressure. Looks good tho. Just a bit funny to me.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      @@jpmonin7429 This is pressure dosing system, not a drip system, so the head pressure needs to be enough to push the effluent to the leach field and spray out of the holes in the laterals. Each dose is 180-gallons and the laterals have holes drilled throughout so that the water sprays up and around the infiltrators to cover the entire field evenly.

  • @russberger8981
    @russberger8981 2 ปีที่แล้ว

    How come they never put fabric over the drain field infiltraters, most installers do . I do it on every one that I install

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      The infiltrators themselves are a hard plastic covering over the laterals. They have breathable baffles on the sides that allow air to get out without allowing dirt to get in.

  • @FBAExapt
    @FBAExapt 2 ปีที่แล้ว

    How much does this cost?

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      An average 2-3 bedroom engineered system is in the 22-25K range, depending on whether or not it needs a pump and how big the leach field/sand filter needs to be.

  • @eresmividaango3
    @eresmividaango3 2 ปีที่แล้ว

    Hi my name is Cesar I need help about the ingenier septic system I live in Reno nevada Washoe county

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      Hello, Cesar. We can answer generic info about this system, but for you'll want to contact an Engineer in your local area to help with any specific questions. Every area is different as far as ground conditions, local code, requirements, etc.

  • @billkea7224
    @billkea7224 2 ปีที่แล้ว +2

    The base under the leach field sure doesn't look permeable.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      It is decomposed granite with a sand filter- a common system in this region that seems to perk well.

  • @robgriffin4716
    @robgriffin4716 2 ปีที่แล้ว +2

    Where are all the ROCKS

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      This was mostly decomposed granite. We got lucky this time, but often times we have to hammer through some pretty hard veins! (In the VERY end of the video, we did hit a rock vein while digging the service line from the house to the tank. Thankfully, it wasn't that bad.

  • @OSHomestead
    @OSHomestead 2 ปีที่แล้ว +1

    How to video? More like a look what we did video. Oh well

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      We appreciate your feedback. We will be working on a more detailed video in the future to explain the process.

  • @bday55
    @bday55 2 ปีที่แล้ว

    whats the cost of something like that and it's for how many people? Thanks

    • @e.torreslohacemossinoloinv2416
      @e.torreslohacemossinoloinv2416 2 ปีที่แล้ว

      Im asking the price is $11k dollars
      Other which sprinkle outside $7k dollars
      Im needed install one is expensive.

    • @bday55
      @bday55 2 ปีที่แล้ว +2

      @@e.torreslohacemossinoloinv2416 How many people would that serve? Looks like a hotel's worth?

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      @@bday55 This was actually a very small home- 1 bed/1 bath. We simply build to the Engineer's design. This area has a lot of decomposed granite and often requires a sand filter.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      Average cost of a 2-3 bedroom Engineered system is 18-22k. If it needs a pump, you can expect about $2750 more in materials.

    • @bday55
      @bday55 2 ปีที่แล้ว +1

      @@ConstructionVideos Thanks! Great Job! Have a great weekend!

  • @zvondushi
    @zvondushi 2 ปีที่แล้ว

    👏👏👏😁😁😁👍👍👍

  • @edwinwise6751
    @edwinwise6751 2 ปีที่แล้ว +1

    The bobcat would easily outdig that backhoe 2 to 1 … wasted time

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      We never know what kind of ground conditions we will encounter. The bobcat was simply a demo we were testing out that day. It did work well, but we ultimately ended up purchasing a CAT miniex.

    • @jpmonin7429
      @jpmonin7429 2 ปีที่แล้ว

      No way in hell. Bobcats don't even dig.

  • @janvanruth3485
    @janvanruth3485 2 ปีที่แล้ว

    talking about overkill...

  • @drj9174
    @drj9174 2 ปีที่แล้ว +1

    We live in Northern NJ and we had a system like this installed and it didn’t last 3 years. Total piece of cr*p. Pun intended.

  • @keyworksales6241
    @keyworksales6241 2 ปีที่แล้ว

    From the pic alone I can tell you that the lateral lines are not code

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      This system is built to code, and as per engineered design specs. It has also been inspected/approved by both Engineer and Environmental Health Inspector.

  • @ibrahimkurt859
    @ibrahimkurt859 2 ปีที่แล้ว +1

    wtf ?

  • @travman2863
    @travman2863 2 ปีที่แล้ว

    Why not just put bacteria from the bottom of the ocean or the bacteria from our salty boggy marshes that breakdown and consume organic matter and convert it into electrical current as long as you use a non-conductive septic tank and then put a superconductive coating on a conductive Rod or strip of metal on each end of the septic tank to receive electrical current discharge from bacteria to power your house or charge an EV vehicle.

  • @paulbetka6477
    @paulbetka6477 2 ปีที่แล้ว

    😠😠😠

  • @danielsmart7368
    @danielsmart7368 2 ปีที่แล้ว

    You really wasted a lot of money by putting the chamber's so close together. They should be 6ft apart

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      This is a bed system, not a trench system and is installed and functions as Engineered. We do both, but this is what the Engineer called for in the tight space on this lot and based on the soils report.

    • @danielsmart7368
      @danielsmart7368 2 ปีที่แล้ว +1

      @@ConstructionVideos I'm from Louisiana everything you dig is clay or iron ore. So I guess that's why we don't do it that way. It causes over saturation in one spot so we have to spread it out.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      @@danielsmart7368 For us, it's mostly DG (decomposed granite) so we actually have to slow it down. That's why we have to bring in the sand filter. There is a 3' deep bed of sand under the chambers. It unfortunately makes it very expensive to install Engineered systems around here. When houses sell now, they are required to have a septic inspection partly because of how costly the replacement/repairs are! Pretty crazy, huh?

  • @snakeeyes3059
    @snakeeyes3059 2 ปีที่แล้ว

    Selling stuff just for profits
    The customer really don't need all of this crap
    Over kill
    An a conventional system would work fine.

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว

      We don't design/upsell the system. The Engineer designs the systems based on local and state requirements/code, so our hands are tied. Part of what makes the systems so costly are the county requirements of a concrete tank (vs a poly/plastic tank), as well as the need for a sand filter to slow the effluent for proper treatment. It is much more complex than the regular systems that are used in other areas, but we don't have any control over what is required, unfortunately.

    • @snakeeyes3059
      @snakeeyes3059 2 ปีที่แล้ว

      @@ConstructionVideos Time for compost law's in that state,
      People are really getting tired of being swindle by greed, and schemes, and manipulation just for profits !
      Not only that we own 14 acres and we are allowed to do what we want on our land as far as septic design
      Just because we own over 10 acre's
      Seems the more wealthy you are the more you are allowed to do what you want !

  • @douglasharris2050
    @douglasharris2050 2 ปีที่แล้ว

    Garbage install and system IMO, too many possible components to fail

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +1

      We simply install what the Engineer designs. This is how 99% of them are designed in our region.

  • @siriosstar4789
    @siriosstar4789 2 ปีที่แล้ว +2

    i've never seen this type of system before .very interesting .
    i use to live on sixty acres in northern California
    where numerous mound systems were tried for years but failed . fortunately i had excellent soil and was able to do the old style drain field while the county was arguing amongst themselves on how to come up with something that worked .
    Mine worked perfect for ten years before i sold the property .

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      Yes, these newer engineered systems are what we have to install about 95% of the time of here. It is expensive, unfortunately. The concrete sand they require us to use to build the sand bed under the leach field is about $37.50/ton. Average 2-3 bedroom system is about 18K-22K, not including a pump, if needed.

    • @siriosstar4789
      @siriosstar4789 2 ปีที่แล้ว +1

      @@ConstructionVideos 20K ?? Wow that's almost triple what i paid ! Yikes .

    • @ConstructionVideos
      @ConstructionVideos  2 ปีที่แล้ว +2

      @@siriosstar4789 I know! materials alone are upwards of 12-15K.

    • @DannyWalker247
      @DannyWalker247 2 ปีที่แล้ว +1

      @@ConstructionVideos Oh my goodness. I knew I loved being on city services but I did not know how much until I saw those numbers.

    • @kovalenkoihor4325
      @kovalenkoihor4325 2 ปีที่แล้ว

      @@ConstructionVideos What is that special about that "concrete sand"? I have no idea what is it but very interested. Is it about granules? Are they "super huge"?