Jacuzzi Sundance Hot Tub FL-2 Error Code | FLOW ERROR CLOSED

แชร์
ฝัง

ความคิดเห็น • 14

  • @VIPPoolsandSpas
    @VIPPoolsandSpas  ปีที่แล้ว +1

    If you have any questions about this video, please comment below or join our membership group.

  • @uncledad7128
    @uncledad7128 ปีที่แล้ว +1

    Thanks for sharing. I see you flipped the breaker off and it was still registering 220 volts. Is that expected?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      lol. thanks for seeing that. lol Editing mistake. Its gone now.

  • @douggibson7875
    @douggibson7875 ปีที่แล้ว +1

    Quick question I have a sundance peyton 680 with fl2 error but I can find the flow switch inside I've replaced the pumps and motors on my own so I know my way around but I can't find anything that looks like a flow switch just hoping u might be able to point me in the right direction

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      Is there a J3 on the circuit board top right?

    • @douggibson7875
      @douggibson7875 ปีที่แล้ว +1

      @VIP Pools and Spas no in top right I see zone 1 if you have an email I would gladly send u a picture of the circuit board

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      @@douggibson7875 info@vippools.ca

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      Change your pressure switch. Here is a video on the pressure switch. Because you have a FL2 error code, it is closed and not open (FL1). Also. Followed wire that connects to the pressure switch to the board and make sure its plugged in all the way.

    • @douggibson7875
      @douggibson7875 ปีที่แล้ว +1

      ​@VIP Pools and Spas
      Not sure where the video link is could you please email me or re attach it to your reply