How to calculate the equivalent circuit for an ultrasonic transducer from impedance

แชร์
ฝัง
  • เผยแพร่เมื่อ 12 ก.ย. 2024

ความคิดเห็น • 10

  • @ultrasonicadvisors
    @ultrasonicadvisors  ปีที่แล้ว

    Sign up for my next webinar here: www.ultrasonicadvisors.com/monthly-ultrasonic-webinar

  • @ricksampson6780
    @ricksampson6780 ปีที่แล้ว +2

    Thanks Husain, all the best for Xmas and the New Year, cheers!

    • @ultrasonicadvisors
      @ultrasonicadvisors  ปีที่แล้ว +1

      Thanks so much! Happy holidays to you and your family!

  • @mavamQ
    @mavamQ 2 หลายเดือนก่อน

    Hi thanks for the video, I was a tech at a company that used 2" PZT-8 bonded to an aluminum plate. I measured to find an equivalent inductance to tune out the piezo capacitance and then could measure R. Now we could setup the amp with a conjugate matching circuit to match C and R of the transducer. We drove it with a 250 watts in a water bath. Our frequency was around 660kHz. My question, we always drove them at the low impedance point. I always wondered why. Is they pattern of the transducer any different between the low and high frequency point?

  • @scorpionbadshah
    @scorpionbadshah ปีที่แล้ว +1

    nice explanation

  • @johnkumar9680
    @johnkumar9680 10 หลายเดือนก่อน +1

    Thank you, sir! Great explanation. Could you tell me where should I study this ultrasonic 40 kHz transducer? Can you tell me any textbooks for driving circuits, equivalent models, and so on..,

    • @ultrasonicadvisors
      @ultrasonicadvisors  10 หลายเดือนก่อน

      Thanks for your interest! I don’t have a book recommendation. That’s actually one reason I started making these videos.

  • @fatiniismail8585
    @fatiniismail8585 ปีที่แล้ว +1

    Hi Dr...I'm Siti Huzaimah.
    Dr, does the value of C2 and R1 change during the vibration? Thank you Dr

    • @ultrasonicadvisors
      @ultrasonicadvisors  ปีที่แล้ว

      The value of R1 mostly changes. C1 and L1 have some change.