HVAC 055 Superheat will move with a fixed orifice.

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 ก.ย. 2024
  • www.love2hvac....

ความคิดเห็น • 29

  • @seanchao6218
    @seanchao6218 11 หลายเดือนก่อน +1

    I have to say you rock, you made the reasoning behind each scenario so clear !!!!! fantastic job, really appreciate it

  • @world1768
    @world1768 3 ปีที่แล้ว +3

    Great video, I’ve seen good teachers on TH-cam but none I could understand better than you. I really like the examples you give with the syringe and the pot that made it a whole lot easier to understand the concepts 👍

  • @jericosha2842
    @jericosha2842 3 ปีที่แล้ว +2

    The way you explain things really helps bring a better understanding of what I'm doing. Thanks man.

  • @resurgensix
    @resurgensix 3 ปีที่แล้ว +2

    Great explanation of how heat effects caps. It is like you were reading my mind because I am currently examining a window unit. Thanks Mr Ty!

    • @love2hvac
      @love2hvac  3 ปีที่แล้ว

      How did the window unit turn out?

  • @charlestrom6508
    @charlestrom6508 2 ปีที่แล้ว +2

    I've been watching your videos for a few weeks now and love them! I often refer people from my FB HVAC groups to your channel! I had already been watching HVAC Know it all, HVAC School, and AC Service tech. All great sources, but your content is my favorite. I love this play list. It feels like a HVAC curriculum. Only thing I would love to see is a type of test between X number of videos. I'd love to be able to test my knowledge as I go so I can go back and re watch videos depending on my test score. Please keep up the good work Ty!!

    • @love2hvac
      @love2hvac  2 ปีที่แล้ว

      Thank you Charles!
      There is a lot of great sources out there. Many of us work together, as everyone learns and connects differently. I'm glad to know this is helping you.
      The test really great idea!
      It will take a little time but I think I can put something together. I appreciate the suggestion, thank you!

  • @DavyDiag
    @DavyDiag 3 หลายเดือนก่อน +1

    great explanation!!

  • @honestman276
    @honestman276 9 หลายเดือนก่อน

    Thanks from Bangladesh.

  • @samsmith854
    @samsmith854 3 ปีที่แล้ว +1

    Sucha in-depth look.! Thanks Ty.!

  • @AngelRodriguez-qg5zq
    @AngelRodriguez-qg5zq 6 หลายเดือนก่อน

    7:52 twelve seconds of pure tension 😂 Thanks Ty.
    I was wondering if you could explain in more detail how the saturation pressure and temperature in the condenser increases due to the temperature of the air at the condenser inlet?

  • @Rodzilla408
    @Rodzilla408 3 ปีที่แล้ว +1

    Great video TY at times/all the time 😆. I for get to do wet bulb and dry bulb and just set my Superheat to 10-15/18°. And look at my temp split. Great video can't wait for the next one.

    • @love2hvac
      @love2hvac  3 ปีที่แล้ว

      Lots of variables. The next video I will show with the chart how changing conditions will look.

  • @kskrawler
    @kskrawler 3 ปีที่แล้ว +1

    This is great and easy to understand.

  • @kentuckyhillbilly455
    @kentuckyhillbilly455 2 ปีที่แล้ว +1

    Love it, keep up the good work.

  • @biblebloopers946
    @biblebloopers946 2 ปีที่แล้ว +1

    At the end of the video when you say we should be able to determine what are super heat should be at, in regards to a split system do you check your superheat at the compressor or at the outlet of the evaporator?

    • @love2hvac
      @love2hvac  2 ปีที่แล้ว

      True superheat is at the evaporator but we early get a pressure port to test there. total superheat is most commonly used at the condensor.
      (Commercial use superheat at the evaporator, resedental typically at the condensor)

  • @imranshaik675
    @imranshaik675 3 ปีที่แล้ว +2

    Sir can u share video with taking examples electronic expansion valve instead fixed orifices mettering devices

    • @love2hvac
      @love2hvac  3 ปีที่แล้ว +1

      Charging a thermostatic expansion valve (TXV/TEV) will be the same method as a (EEV/EXV).
      The TXV/TEV videos will be up in the next few days and the EEV/EXV videos will be up in a few weeks.
      I always start out with fixed office metering devices
      Once a student understands that, it give greater appreciation to the TXV/TEV

  • @moonlightacmaintenance3232
    @moonlightacmaintenance3232 3 ปีที่แล้ว +2

    If your outdoor condenser is in direct sunlight how do you approach taking outdoor dry-bulb temp with the thermocouple? Do you try to create artificial shade or leave probe in the direct sunlight?

    • @love2hvac
      @love2hvac  3 ปีที่แล้ว +2

      Yes, a clip board, paper, anything to block the direct sunlight

    • @moonlightacmaintenance3232
      @moonlightacmaintenance3232 3 ปีที่แล้ว +2

      Thank you sir, as a 40 something year old guy restarting a new career along with going to a two year college I’m learning so much real quick. I may be learning more from you then from my actual school 🤫

    • @inothing7370
      @inothing7370 3 ปีที่แล้ว +1

      @@moonlightacmaintenance3232 I'm 39 just about to take 608, would love to talk to someone likes me getting into the feild... Discord?

    • @moonlightacmaintenance3232
      @moonlightacmaintenance3232 3 ปีที่แล้ว +1

      @@inothing7370 it’s never to late to learn something new

  • @samersarah957
    @samersarah957 2 ปีที่แล้ว +1

    Hello Mr.Ty. system charged correctly and every thing in it work ok so is possible to overfill evaporator and cause damage to vapor pump? Thank you.💐

    • @love2hvac
      @love2hvac  2 ปีที่แล้ว

      If everything is working correctly no chance of overfilling the evaporator and damaging the compressor.
      Running under low bient conditions,
      Things that will:
      Over charged,
      Bad or low air flow, (duct, filter, coil dirty)
      Missing or oversized metering device,
      Evap coil too small/not matched to the condensor.
      TXV oversized, it damaged
      Contactor welds shut keeping the compressor running when unit shuts off.
      There's probay something else...

  • @WallaceRoseVincent
    @WallaceRoseVincent ปีที่แล้ว +1

    Is it possible to replace a piston with a txv? Is it possible and is thete any benefit to making the change? Is there a drop in replacement?

    • @love2hvac
      @love2hvac  ปีที่แล้ว +1

      Absolutely. In this video series I talk about replacing a fixed orifice with a TXV.
      The TXV will control superheat, extend compressor life and perform better.
      However to do it without other work being performed is cost prohibitive.

  • @realestateservicessaleshea99