Paano magcalculate ng wire size at circuit breaker size ng bahay na may sukat hanggang 50 sq.m

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ต.ค. 2024

ความคิดเห็น • 32

  • @TagalogElectricaltips
    @TagalogElectricaltips  4 ปีที่แล้ว +3

    Tandaan po natin na yung total current ay 15.93 Amperes, kaya sapat lng po yung 20 amperes na circuit breaker at 3.5 sq.mm na wire

    • @marlonmendoza6250
      @marlonmendoza6250 4 ปีที่แล้ว +1

      Multi dwelling units nman sir sa susunod with pec 2917

    • @TagalogElectricaltips
      @TagalogElectricaltips  4 ปีที่แล้ว +4

      @@marlonmendoza6250 ok, ipila ko yung sa multi family dwelling. Salamat

  • @faustoclemente6046
    @faustoclemente6046 4 ปีที่แล้ว +3

    Isa akong pulpol na electrician na natuto lamang dahil sa experience at turo ng mga master electrician . Alam kong marami pa po akong kakulangan at hindi sapat ang kaalaman . Natuwa ako at nakita ko ang blog site mo at nagkaroon na naman ako ng pagkakataon na matutong muli. Napakahusay mong magturo, you are a real master and professional. God bless you always.

    • @TagalogElectricaltips
      @TagalogElectricaltips  4 ปีที่แล้ว +1

      hi austo slamat sa comment mo, pero hindi nman ako master, gusto ko lng ibahagi ang aking nalalaman. godbles din s u

  • @r.salvadorofficialvlog7380
    @r.salvadorofficialvlog7380 3 ปีที่แล้ว

    Sir salamat po info.ang galing mo magpaliwanag!!!

  • @papadigz5800
    @papadigz5800 3 ปีที่แล้ว +1

    Paano po kung magkaroon ng isang refrigerator sir

  • @gegiecebuano9299
    @gegiecebuano9299 26 วันที่ผ่านมา

    Pwedi po maka hingi ng PEC copy. Thanks much

  • @mr.yhuztv5886
    @mr.yhuztv5886 2 ปีที่แล้ว +1

    Sir paano malaman ang VA Ng isang appliances?

    • @TagalogElectricaltips
      @TagalogElectricaltips  2 ปีที่แล้ว +1

      sa nmaplate ng appliances nkagay ang power rating in watts at power factor. Idivide mo ng power factor yung power in watts, ung sagot ay VA. kung wala nmang nklagay ng power factor yung appliances, kung ano ang value sa watts yun n ang gamitin mo sa VA, konti lng nman ang difference.

  • @albertacosta3803
    @albertacosta3803 2 ปีที่แล้ว

    Sir meron po bang formula sa pagcompute ng ampere frame?

  • @larrysanchez2766
    @larrysanchez2766 4 ปีที่แล้ว +1

    Sir,abangan ko naman ang next video mo sa mas higit pa sa 50 square meter.

  • @julieanngudes6431
    @julieanngudes6431 4 ปีที่แล้ว +1

    God bless po

  • @boybravo689
    @boybravo689 4 ปีที่แล้ว +1

    Sir maiba lng tayo ng topic halimbawa gagawan ng service entrance o entrada yang bhay na yan ano ho ang height requirement ng meter base ayon sa pec required ho bang maglagay ng equipment circuit breaker at ano naman ang height required at sa loob naman ng bhay ano naman ang height ng co switch at panel board mula finish floor tnx sir

    • @TagalogElectricaltips
      @TagalogElectricaltips  4 ปีที่แล้ว

      Hindi maselan sa meter base as long as mabasa ang metro pero the usual is at eyesight level. Isang circuit breaker lng ilagay sa loob ng bahay 30 Amps. Approx 1.8 mtrs above finish floor level

    • @boybravo689
      @boybravo689 4 ปีที่แล้ว

      @@TagalogElectricaltips ang height ng switch at ang co walang specific ang pec Sir

  • @roelalintv1421
    @roelalintv1421 3 ปีที่แล้ว

    iyong 20 ampers na breaker Ang wire na gamitin natin sa service entrance cap number 12 din? iyong sa lighting Naman at outlet number 12 ba din at number 14?

  • @roelalintv1421
    @roelalintv1421 3 ปีที่แล้ว +1

    Ask po Lang ako sir, iyong article Ng P.E.C po ba ay nagbabago po ba kada taon?

  • @bloomberg4865
    @bloomberg4865 4 ปีที่แล้ว +1

    Sir ung general lighting loads po ba ay para lang sa mga lighting circuits ? Then 2nd question q po ung 1200 va po idedevide ko para mabilang q ung no of max circuits for lightngs ?

    • @TagalogElectricaltips
      @TagalogElectricaltips  4 ปีที่แล้ว +1

      Ang general lighting load ay para sa lighting at convenience outlet. Hahawa ako tutorial nito na ang basehan ay philippine electrical code

  • @melaniocomaling6928
    @melaniocomaling6928 3 ปีที่แล้ว

    Salamat sa sapag share ng kaalaman sir. Pero sa lugar namin sir single breaker 30 ampere ang karamihan pati bahay namin 30 ampere single breaker bakit pinayagan sa service provider sir na Wala paka yun sa PEC? Follow up question sir anong Po ang gamitin na wire pang entrada sa single breaker?

  • @danilolegaspi1819
    @danilolegaspi1819 ปีที่แล้ว

    Wala pong reff

  • @bloomberg4865
    @bloomberg4865 4 ปีที่แล้ว +1

    Sir bakit po ung total load na 3540va na mai 15.39 Amp bakit po hindi minultiply sa 1.25 ? Kc po db sa feeder ang rule is non cont 100% +125% cont.nalilito po kc aq minsan sa mga computation ginagamit demand factor tables sa pec minsan naman jn sila sa rule na yan nag bbased . Salamat po 😀

    • @TagalogElectricaltips
      @TagalogElectricaltips  4 ปีที่แล้ว

      Di n kailangan. As long ad less than 50 sq m at mot more than 3680 VA yung load as per PEC

  • @melaniocomaling6928
    @melaniocomaling6928 3 ปีที่แล้ว +1

    New subscriber Po ako sir ask lang po ako pinapanuod ko po yong ibang yutube tuturial tungkol sa single circuit sir hindi na nila sinali ang 50sq x 24. Total load lang ng bahay doutb lng po ako sir Kung ano po talaga ang Tama?

  • @vincemirate1610
    @vincemirate1610 4 ปีที่แล้ว

    May shout out po ba kyo

  • @zaldyroxas2062
    @zaldyroxas2062 3 ปีที่แล้ว

    Idol pa compute nman 60amp per meter 10 units po ilan size ng wire ang entrance..salamat po

  • @roelalintv1421
    @roelalintv1421 3 ปีที่แล้ว

    Electrical engineer ba kayo sir?