𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞𝙣𝙜 𝙋𝙧𝙤𝙘𝙚𝙙𝙪𝙧𝙚 | Procedure to Test the Thyristor with the help of Multimeter
ฝัง
- เผยแพร่เมื่อ 4 ก.พ. 2025
- 𝙋𝙤𝙬𝙚𝙧 𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧/Diode Module PK25FG series are designed for various rectifier circuits and power controls. For your circuit application, following internal connections and wide voltage ratings up to 1600V are available and electrically isolated mounting base make your mechanical design easy.
@FlowChart 👍
𝐏𝐥𝐞𝐚𝐬𝐞🙏 𝐒𝐮𝐛𝐬𝐜𝐫𝐢𝐛𝐞👆 𝐭𝐡𝐞 𝐜𝐡𝐚𝐧𝐧𝐞𝐥
• 𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞...
#electricvideo #powerelectronics #electrical #electronics #thyristor #IGBT #transistor #components #industry #scr #siliconcontrolledrectifier #DMM
🧰𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞𝙣𝙜 𝙋𝙧𝙤𝙘𝙚𝙙𝙪𝙧𝙚 | Procedure to Test the Thyristor with the help of Multimeter
𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞𝙣𝙜 𝙋𝙧𝙤𝙘𝙚𝙙𝙪𝙧𝙚 | How to check thyristor using multimeter? Thyristor testing
• 𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞...
🛠️𝙄𝙂𝘽𝙏 𝙏𝙀𝙎𝙏𝙄𝙉𝙂 | 𝙃𝙤𝙬 𝙩𝙤 𝙩𝙚𝙨𝙩 𝙖𝙣 𝙄𝙂𝘽𝙏?
• IGBT check with multim...
-
👨🔧𝙄𝙂𝘽𝙏 𝙋𝙤𝙬𝙚𝙧 𝙈𝙤𝙙𝙪𝙡𝙚, 𝙍𝙚𝙘𝙩𝙞𝙛𝙞𝙚𝙧, 𝘽𝙧𝙖𝙠𝙚 𝘾𝙝𝙤𝙥𝙥𝙚𝙧, 𝙏𝙝𝙚𝙧𝙢𝙞𝙨𝙩𝙤𝙧 𝙏𝙚𝙨𝙩𝙞𝙣𝙜. 𝙀𝙪𝙥𝙚𝙘, 𝙛𝙪𝙟𝙞, 𝙄𝙣𝙛𝙞𝙣𝙚𝙤𝙣, 𝙥𝙞𝙢, 7𝙈𝘽𝙍, 𝙨𝙚𝙢𝙞𝙠𝙧𝙤𝙣
• How to check IGBT usin...
🏭𝙄𝙂𝘽𝙏 𝙏𝙚𝙨𝙩𝙞𝙣𝙜 𝙒𝙞𝙩𝙝 𝘼𝙣𝙖𝙡𝙤𝙜 𝘼𝙑𝙊 𝙖𝙣𝙙 𝘿𝙞𝙜𝙞𝙩𝙖𝙡 𝙈𝙪𝙡𝙩𝙞𝙢𝙚𝙩𝙚𝙧 | 𝙂𝙖𝙩𝙚 𝙏𝙚𝙨𝙩 | 𝙍𝙚𝙘𝙩𝙞𝙛𝙞𝙚𝙧 | 𝙄𝙣𝙫𝙚𝙧𝙩𝙚𝙧
• IGBT testing with AV...
🌍Thyristor module/ 3 Phase Converter with Rush Current SCR testing
• How to check 𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧...
🕹️𝙋𝙧𝙤𝙘𝙚𝙙𝙪𝙧𝙚 𝙩𝙤 𝙏𝙚𝙨𝙩 𝙩𝙝𝙚 𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙬𝙞𝙩𝙝 𝙩𝙝𝙚 𝙝𝙚𝙡𝙥 𝙤𝙛 𝙈𝙪𝙡𝙩𝙞𝙢𝙚𝙩𝙚𝙧:
To test the THYRISTOR, keep the Multimeter into Ohm/Diode meter mode.
Connect the positive output lead of the multimeter to the anode and the negative lead to the cathode.
The multimeter should indicate no continuity.
Touch the gate of the THYRISTOR to the anode.
The multimeter should indicate continuity through the THYRISTOR.
When the gate lead is removed from the anode, conduction may stop or continue depending on whether the multimeter is supplying enough current to keep the device above its holding current level.
If the multimeter indicates continuity through the THYRISTOR before the gate is touched to the anode, it indicates that the THYRISTOR is shorted.
If the multimeter will not indicate continuity through the THYRISTOR after the gate has been touched to the anode, it indicates that the THYRISTOR is open.
𝙀𝙡𝙚𝙘𝙩𝙧𝙞𝙘𝙖𝙡/𝙀𝙡𝙚𝙘𝙩𝙧𝙤𝙣𝙞𝙘𝙨: • Electrical/Electronics
👍
𝙄𝙣𝙫𝙚𝙧𝙩𝙚𝙧/ 𝙑𝙁𝘿/ 𝘿𝙍𝙄𝙑𝙀: • Inverter/ VFD/ DRIVE
👍
𝐔𝐭𝐢𝐥𝐢𝐭𝐲: 𝐆𝐞𝐧𝐞𝐫𝐚𝐭𝐨𝐫, 𝐁𝐨𝐢𝐥𝐞𝐫, 𝐀𝐢𝐫 𝐂𝐨𝐦𝐩𝐫𝐞𝐬𝐬𝐨𝐫: • Utility: Generator, Bo...
👍
Career: • Career
👍
On-Tech: • On-Tech
#Electrical
#Electronics
#technology
#repairing
#Services
#engineering
#tech
#howto
#testing
#machine
#industry
#maintenances
electrical learning
electronic learning
electric circuits,
beginner electronics,
#ElectricalLearning, #Electronics, #EngineeringTips #DIY
#howtofix #learningelectronics
#ElectricalEngineering
#ElectronicsTutorials
#ElectricalLearning
#CircuitDesign
#ElectronicsForBeginners
#DIYElectronics
#ElectricCircuits
#ElectronicsProjects
#EngineeringTips
#LearnElectronics
#PowerElectronics
#ArduinoProjects
#PCBDesign
#Microcontrollers
#RenewableEnergy
#ElectricalWiring
#IoTProjects
#SmartHomeSystems
#MotorControl
#Electromagnetism
#BeginnersGuideToElectronics
#ElectricalBasics
#StudentsLearningElectronics
#EngineeringStudents
#TechEducation
#SustainableEnergy
#ElectricVehicles
#Robotics
#HomeAutomation
#SolarEnergySystems
#EnergyEfficiency
#SubscribeAndLearn
#DIYProjects
#HandsOnLearning
#StepByStepTutorial
excellent. thanks for easy procedure
Welcome
Good
Thanks
This is extremely helpful. Thank you so much. I don’t know how you determined the gate pin though.
Welcome
A very good demonstration.
Thank you sir
Pls upload some more videos about thyristor rectifier
Ok
Ol
Thanks ❤ 👍🏽
Welcome
Of course it will connect, because you connected the gate (which has only few ohm to cathode) to anode
It’s just a testing way. Youbcan test in another way also.
The connection between the two probes are closed via the gate, doesn't proof anything
Indeed, I believe it should remain conducting after the gate is disconnected from anode, right? That is not happening here.
So if I get a resistance of 0.0001 ohm on continuity test (your first test) does it mean the thyristor is faulty?
Oo
❤
Thanks
Kindly reduce that background music so that we can hear clearly
Thanks
Is it for convert AC to DC right?
Yes
@FlowChart how to wiring AC input and DC output? I see only one AC input
@@FlowChart ??????
This type 3 pcs used for making 3 phase SCR or converter. Please check drawing.
@@FlowChart we output DC- and AC neutral together?
Thank you very much
Welcome, share the video and stay with Flow Chart
How will I determine the bad scr
Follow
hi! I have scr but there no datasheet. How I can find which one is the gate terminal?
Measure as per diagram
What does happen when we check in reverse bias ..
Watch the Video
Where can i buy this thyrister?
Electronic market
Sanrex rex product upload some more videos
Ok
🙏🙏🙏🙏🙏
Thank you
Be multimeter!
Ok
This is not correct. You can’t use the multimeter diode voltage the power tue gate. All you’re doing is testing the gate to cathode. If the gate was closed you’d still get the same reading.
Thanks
Wrong! but after trigger gate pin continuously go A to K path
Thanks
👍, sorry your voice not clear
Thanks for your comment
Irritating sound
Thanks for feedback
Not gud
Thanks
How will I determine the bad scr
Watch video, you will got the point