How to Take an Open Tray Implant Impression

แชร์
ฝัง
  • เผยแพร่เมื่อ 26 พ.ค. 2022
  • In this video we give you some useful information for taking an open tray implant impression.
    Open tray impressions are the type that require a hole in the impression tray which gives access to unscrew the coping. This allows the impression coping to stay in the tray when the impression is pulled from the mouth.
    In order to take the impression you will need an open tray impression coping which is also known as a direct transfer or pick-up coping. It's important that you only use an impression coping that is designed for the open tray technique to avoid an inaccurate impression.
    The other thing you'll need is a tray with a hole in it at the site of the implant. Your lab can make you a custom tray with the hole already in place or you can take a stock tray and create the hole with a grinding bur. If you're going to create the hole in a stock tray, it may be easiest to determine the correct location of the hole after you have placed the impression coping.
    Once you remove the healing abutment, you'll attach the transfer coping to the implant. This can be done by inserting the coping in to the tissue until you hit resistance from the implant interface. Then, slowly rotate the coping while applying very slight pressure so that when rotational alignment is achieved, the transfer coping will seat completely to the implant.
    The impression coping screw can be hand torqued and a torque driver isn't necessary. When you're torqueing in the screw you shouldn't feel any resistance. If you do feel resistance, there is good chance that the impression coping is not completely seated on one side and therefore the threads of the screw aren’t completely lined up with the internal threads of the implant.
    Once you have verified that the impression coping is fully seated, you're ready to prepare the tray. If you're using a stock tray, place the tray in the mouth to see where the impression coping is in relation to the tray. Then, remove the tray from the mouth and grind out the hole in that location. After you have created the hole, place the tray back in the mouth to make sure the hole was created in the correct location. Depending on the length of the impression coping, it may not actually stick through the tray. The important thing is that the screw can be easily accessed and removed through that hole. If needed, make some additional adjustments to the tray to ensure the impression coping or the impression coping screw will fit passively through the hole.
    This information is applicable to most implant systems including Nobel Biocare, Straumann, ZimVie (Zimmer Biomet), Dentsply Astra, BioHorizons, and Implant Direct.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 28

  • @tamibear7598
    @tamibear7598 10 หลายเดือนก่อน +1

    Thank you doctor.

  • @Drloisessien
    @Drloisessien ปีที่แล้ว

    Yes. I find this video helpful indeed. Thanks

  • @emmac687
    @emmac687 ปีที่แล้ว

    Great video! Am a current D2 and have an exam tomorrow and you helped me understand a concept. Thank you!

    • @OBrienDentalLab
      @OBrienDentalLab  ปีที่แล้ว

      That's great! We wish you the best on your exam!

  • @commanderkeen3787
    @commanderkeen3787 2 ปีที่แล้ว +3

    Excellent informative video

  • @rossannedoce9285
    @rossannedoce9285 7 หลายเดือนก่อน

    Excellent explanation thank youu doctor

    • @OBrienDentalLab
      @OBrienDentalLab  7 หลายเดือนก่อน

      Thank you! We appreciate the feedback.

  • @sharongreenfeld21
    @sharongreenfeld21 ปีที่แล้ว

    Thank you extremely hopeful !!!

  • @sandyloo5328
    @sandyloo5328 6 หลายเดือนก่อน

    Great video, excellent explanation, if the tray is removable implant impression tray. Will it be more efficient and convenient?

  • @chhayatakvani9206
    @chhayatakvani9206 ปีที่แล้ว

    Super

  • @zerlishzz6765
    @zerlishzz6765 11 หลายเดือนก่อน

    Thanku Sir❤

  • @StephenLaHart
    @StephenLaHart 8 วันที่ผ่านมา

    Great video thank you. How should someone choose a proper impression coping width for an implant?

    • @OBrienDentalLab
      @OBrienDentalLab  5 วันที่ผ่านมา +1

      The impression coping emergence size should correspond to the healing abutment diameter.

    • @StephenLaHart
      @StephenLaHart 4 วันที่ผ่านมา

      @@OBrienDentalLab Thank you

  • @pratimambekar1587
    @pratimambekar1587 ปีที่แล้ว

    Great video.
    If a implant pre-mounted, can the mount be utilised fr open tray impression

    • @OBrienDentalLab
      @OBrienDentalLab  ปีที่แล้ว

      That depends on the implant system. Some systems do have a mount that can also be used as an impression coping, but most do not.

  • @dr.conradg355
    @dr.conradg355 3 หลายเดือนก่อน

    Hi do you have a video for a All on 4 open tray impression?

    • @OBrienDentalLab
      @OBrienDentalLab  3 หลายเดือนก่อน

      We have not made a video for that yet

  • @Ms14Th12
    @Ms14Th12 ปีที่แล้ว

    What the difference between open tray technique and closed ?

    • @OBrienDentalLab
      @OBrienDentalLab  ปีที่แล้ว

      This video may help answer your question: th-cam.com/video/XHpRklRCIg8/w-d-xo.html

  • @nehagaikwad100
    @nehagaikwad100 ปีที่แล้ว

    Wht is choice of impression coping in limited mouth opening

    • @OBrienDentalLab
      @OBrienDentalLab  ปีที่แล้ว

      A closed tray impression coping will typically be easier to use in that situation since they are usually shorter. If you have an intra-oral scanner, a scanbody would be the best option.

  • @ghaytho.dabbagh1311
    @ghaytho.dabbagh1311 2 ปีที่แล้ว

    Hopefully one day this method would be obsolete, and everyone would use scan abutments.
    But for the meantime, thanks a lot for the wounderful vedio