Colour Fastness to Water test ISO 105-E01

แชร์
ฝัง
  • เผยแพร่เมื่อ 30 ก.ย. 2024
  • I explain about this test :---
    1. Specimen size(40 ± 2) mm × (100 ± 2) and Multifiber size (40 ± 2) mm × (100 ± 2)
    2. Stitch the specimen with multifiber on face side
    3. Specimen Immerse in water for 30 min.
    4. Take water 50:1 times (in original weight of the specimen )
    5. Mount the specimen perspiration tester and weight apply (12,5 ± 0,9) kPa With acrylic plate (No. of Acrylic plate11)
    6. Heat the loaded specimen in oven at (37 ± 2) °C. for 4 h.
    7. Remove the specimen in perspiration tester and drying separate specimen and multifiber for over night after that assessment.
    Note :--- I am explaining this test
    I have explained as much as I know if there is any error please comment.
    you have any question regarding this test plz comment.
    BELOW LINK PROVIDED FOR TEST
    Please Subscribe and Share my channel
    My Email: -- mauryarohit108@gmail.com
    ASTM D3512 RTP PILLING TEST
    • PILLING TEST ASTM D3512
    FABRIC WEIGHT ASTM D3776 Option -C (GSM)
    • FABRIC WEIGHT ASTM D37...
    Tensile Strength ASTM D5034
    • Tensile Strength ASTM ...

ความคิดเห็น • 6

  • @gauravdhar5482
    @gauravdhar5482 2 ปีที่แล้ว

    Is it distilled to be immersed or any clear water like tap water..?

  • @AjayakumarNair-q6u
    @AjayakumarNair-q6u 5 หลายเดือนก่อน

    Voice is not clear sir

    • @rrmtextile2318
      @rrmtextile2318  5 หลายเดือนก่อน

      I will try better in the next time

  • @Joabsb
    @Joabsb 2 ปีที่แล้ว

    Iso 105 E11?

  • @Deepaksharma-tu8op
    @Deepaksharma-tu8op 3 ปีที่แล้ว

    Voice nahi hai