What is Scaling in PLC?- Analog Input/Output - PLC Training in Tamil - Part 02

แชร์
ฝัง
  • เผยแพร่เมื่อ 10 ก.ย. 2024
  • Scaling is explained here..How we get input from Analog input devices & how it takes to PLC, How we process the value & how we show that value in HMI..
    Part 1 scaling - • What is Scaling in PLC...
    DI,DO,AI,AO In PLC - • What is PLC I/O? - Dig...
    Analog Input,Output - • What is PLC I/O? - Ana...
    Scaling - • What is Scaling in PLC...
    2 wire,3wire,4wire sensor - wiring in PLC - • 2 wire, 3 Wire, 4 wire...
    RTD - • What is Sensor? - RTD ...
    Limit switch - • Limit Switch working -... .
    watch next videos to understand fully..
    Any doubts please comment below..
    Whatsapp - 9940988811
    Mail - unikerztechnologies@gmail.com
    Share to your friends ,..
    Subscribe our channel to get more videos
    Thanks for watching
    #ScalinginPLC #Scaling #PLCTraining
    LIKE-SHARE-SUBSCRIBE our channel. Follow us on other social medias for latest updates..
    Fb - / unikerz
    Quara - www.quora.com/....

ความคิดเห็น • 27

  • @monishkumar1911
    @monishkumar1911 5 ปีที่แล้ว +6

    * For temp. Range 0 to 100 , the count value for 35 degree celusis is 11468. Current is 9.6 mA
    * For temp. Range -50 to +50 , the count value for 35 deg. Celusis is 27851. Current is 17.6 mA

  • @kalaivanipadmanaban6568
    @kalaivanipadmanaban6568 10 หลายเดือนก่อน +1

    tank u for giving this vedio sir.

  • @thansheer7493
    @thansheer7493 5 ปีที่แล้ว +3

    5:40 grt info..thanks for uploading

  • @sinnasamy3681
    @sinnasamy3681 5 ปีที่แล้ว +3

    நன்றி

  • @anandraj1419
    @anandraj1419 5 ปีที่แล้ว +5

    The decimal value of 35 deg. Celsius for 0-100 deg range rtd(0-32767 range) is 11468.45 and the current range is 9.6mA

    • @stararun1996
      @stararun1996 5 ปีที่แล้ว +1

      Correct

    • @stararun1996
      @stararun1996 5 ปีที่แล้ว +1

      11468.45 epdi

    • @anandraj1419
      @anandraj1419 5 ปีที่แล้ว +2

      @@stararun1996 (35/100)*32767=11468.45

  • @sinnasamy3681
    @sinnasamy3681 5 ปีที่แล้ว +3

    (0-100) (0-37268) 37268÷100=372.68×30=11,180.4

  • @mohamedabdulla6483
    @mohamedabdulla6483 5 ปีที่แล้ว +2

    Brother
    Can you please make a video on VFD Parameter settings with examples and also it's PID controller
    What is two pole, three-pole, four pole in VFD

  • @sivanandanmohankumar5284
    @sivanandanmohankumar5284 3 ปีที่แล้ว +1

    9.6 mA

  • @santhoshavsk7701
    @santhoshavsk7701 3 ปีที่แล้ว

    Hai sir why this range start from 4 ,4to 20ma?

  • @samuelsolomon2028
    @samuelsolomon2028 5 ปีที่แล้ว +3

    First we calculate how much count taken for 1°C = 32768/100 = 327.68 count....then easily we can calculate 35°C = 327.68*35 = 11468.8 counts...

  • @berlinelectrical5721
    @berlinelectrical5721 3 ปีที่แล้ว

    what is the different between 0 to 10v and 4 to 20ma

  • @GopiNath-ob4vb
    @GopiNath-ob4vb 5 หลายเดือนก่อน

    10.5 mA

  • @salimyousuf8848
    @salimyousuf8848 5 ปีที่แล้ว +1

    17.6mA

  • @MrSahaya97
    @MrSahaya97 ปีที่แล้ว

    11468.45

  • @MrSai27
    @MrSai27 5 ปีที่แล้ว

    Pls make in english or hindi la guage

  • @gv1035
    @gv1035 4 ปีที่แล้ว

    For 35% is 9.6mA

  • @ajaymarswin4480
    @ajaymarswin4480 4 ปีที่แล้ว

    4.017

  • @gv1035
    @gv1035 4 ปีที่แล้ว

    For 80% is 16.8mA

  • @gv1035
    @gv1035 4 ปีที่แล้ว

    U r saying wrong.. From 2 only u are calculated in that scale.. So, answer is 8.5... But u are saying 7.5.. Could u explain clearly

    • @UNIKERZTECHNOLOGIES
      @UNIKERZTECHNOLOGIES  4 ปีที่แล้ว

      He says from 3 to 10.5, not from 2!.. please watch 2.56 sec

  • @vigneshchandrasekaran5219
    @vigneshchandrasekaran5219 4 ปีที่แล้ว

    11468

  • @dhayaland1340
    @dhayaland1340 11 หลายเดือนก่อน

    21298.55

  • @sabaris686
    @sabaris686 3 ปีที่แล้ว

    11468.45