Pro-Flex CSST and Product Overview

แชร์
ฝัง
  • เผยแพร่เมื่อ 8 ก.ย. 2024
  • This video is a quick look at how to assemble the Pro-Flex CSST system and a quick look into the rest of the product line.
    To certify, please click the following link: installers.pro...

ความคิดเห็น • 71

  • @PJBeee
    @PJBeee 2 ปีที่แล้ว +7

    Stuff works great. My experience with the 1" (Flak-Jacket), however is that the split ring (first washer in) does not go easily into the collet. You just might need to force the collet over it with a screwdriver, and it's OK to do this without the 2nd washer or O-ring being installed. You can then test that the collet screws at least loosely onto the fitting, and then unscrew from the fitting and install the solid washer and O-ring. And of course, the split washer has nothing to do with the gas seal itself - the O-ring mate-to-fitting does that - so go ahead and force the split ring in. I've not had any leaks of any kind. But the 1" Flak-jacket stuff is pretty stiff, so be prepared to spend some time putting the fittings on, which includes the time to remove some of the jacket, as the instructions say. Otherwise, real happy with the stuff. The Flak-Jacket is reassuringly tough, so it should work well for many years. For my uses, it eliminated the need for some elbows, which reduce the effective pipe length, for specific nipple lengths, and for unions, which can leak.

    • @eusebiobatan
      @eusebiobatan หลายเดือนก่อน

      Cslofdbyoul

    • @eusebiobatan
      @eusebiobatan หลายเดือนก่อน

      Carlos yulo

  • @isaacmoffett5799
    @isaacmoffett5799 2 ปีที่แล้ว +5

    I love this stuff. So easy to work with.

  • @guanoApe
    @guanoApe ปีที่แล้ว +1

    Thanks Buck

  • @matthewedwardsnyder
    @matthewedwardsnyder 4 หลายเดือนก่อน +1

    Thanks

  • @raylongoria7178
    @raylongoria7178 3 ปีที่แล้ว +2

    Coooolllll! Thank you!

  • @greganderson1681
    @greganderson1681 2 ปีที่แล้ว +2

    Getting some tomorrow. Never using homeflex again.

  • @thebigroy
    @thebigroy ปีที่แล้ว

    For Flak Jacket do you need to bond it to the panel? I really like that you have to worry less about electric issues with this black version.

  • @robertbrown6311
    @robertbrown6311 ปีที่แล้ว

    I bought the kit.......why doesn't the slide ring fit over the supplied hose?

  • @edbouhl3100
    @edbouhl3100 ปีที่แล้ว

    If for some reason you needed to put 2 runs of CSST in the same trench, is there a required or suggested separation distance?

  • @gabaknegocios
    @gabaknegocios 5 หลายเดือนก่อน

    your URL you left in the video description does not work

  • @garrysingh9038
    @garrysingh9038 ปีที่แล้ว

    Hi can we use grey quick connect natural gas barbecue hose to natural gas cooktop?

  • @mikegomez5796
    @mikegomez5796 ปีที่แล้ว +1

    The stuff that Lowe's carry says 5 psi max? Is this true? How can u test it with 15 psi if this true?

    • @YouTubeUserNumber1
      @YouTubeUserNumber1 ปีที่แล้ว

      That's just what it's been certified for. He cranked it up for this demo to show how good the fittings are with hand tighten only.

  • @tophatt5706
    @tophatt5706 4 หลายเดือนก่อน

    My kits come with 4 pieces, not 3. There's an additional washer the jagged end makes contact with.

    • @PJBeee
      @PJBeee 20 วันที่ผ่านมา

      Just checked with the Pro-Flex people. The fourth piece is a "high-temperature gasket." It was pre-installed in my fittings when I received them new. In the replacement ring/gasket kit, there is a new gasket included. Maybe newer fittings come with it separately.

  • @f.j.g.j.6563
    @f.j.g.j.6563 3 ปีที่แล้ว +2

    No hablo mucho inglés pero te entendí! 👍

  • @augustreigns9716
    @augustreigns9716 2 ปีที่แล้ว

    thank you

  • @knoxflyer101
    @knoxflyer101 3 ปีที่แล้ว +1

    Where can in get that strut pump that connects to my test gage??

    • @pro-flex7142
      @pro-flex7142  3 ปีที่แล้ว +1

      Reach out to your regional and they can get you taken care of.

  • @joshuamoore24_7
    @joshuamoore24_7 ปีที่แล้ว +2

    I would stick to using wrought iron or gas tite. That o ring on pro flex seems like a weak point that could leak.

  • @victorcontreras348
    @victorcontreras348 2 ปีที่แล้ว +1

    What do I use to cut the flex pipe?

    • @pro-flex7142
      @pro-flex7142  2 ปีที่แล้ว +1

      Pro-Flex offers a stainless steel tubing cutter, however, any tubing cutter you have would work just fine.

  • @sandwichfiend686
    @sandwichfiend686 3 ปีที่แล้ว +2

    I purchased 1/2 flak jacket from Menards but none of the 1/2" fittings slide on the way you showed it. The tubing is too thick. Should I remove 10 valleys instead of 4 so it'll fit on?

    • @anthonystella1819
      @anthonystella1819 2 ปีที่แล้ว

      It's been 9 months since your post... what did you end up doing? I am having the same issue.

    • @sandwichfiend686
      @sandwichfiend686 2 ปีที่แล้ว +1

      @@anthonystella1819 I called the hotline number and apparently they changed their design (even though they say they have never changed the design) but inventory doesn't turn over quickly and many stores still have the old stock. Yes, you just cut away the extra valleys and it does the trick.

  • @nickdeliso7026
    @nickdeliso7026 ปีที่แล้ว

    So I’m running this thru the attic, and down an outside wall, connecting to galvanized pipe. Do I need the stub out to go thru the wall to stove?

    • @YouTubeUserNumber1
      @YouTubeUserNumber1 ปีที่แล้ว

      Galvanized pipe should not be used for fuel gas systems.

    • @nickdeliso7026
      @nickdeliso7026 ปีที่แล้ว

      @@TH-camUserNumber1 Down in Florida black pipe will rust quickly. Galvanized is code here. Go figure.

    • @YouTubeUserNumber1
      @YouTubeUserNumber1 ปีที่แล้ว

      @nickdeliso7026 interesting, I thought code prohibited galvanized everywhere in the US since it can flake. We just paint the black pipe on the west coast and it holds up. Cheers

    • @nickdeliso7026
      @nickdeliso7026 ปีที่แล้ว

      @@TH-camUserNumber1 That was my plan, but I called the county and was told that was how it had to be. Had to return all the black pipe and buy galvanized. The rain and constant humidity down here is brutal. Thanks!

  • @المهني
    @المهني 3 ปีที่แล้ว +1

    Hi, how to buy this tube from any site

    • @PJBeee
      @PJBeee 2 ปีที่แล้ว

      It is hard to find, and even harder to find by the foot. But do some searches.

  • @martinauley
    @martinauley 2 ปีที่แล้ว

    I can't find the product anywhere; particularly the 1" dia size. Anyone know where there is a source in Olympia Wa?

    • @njhannan
      @njhannan ปีที่แล้ว

      Thermal, Geary Pacific, Airefco

  • @dastick66
    @dastick66 2 ปีที่แล้ว

    I need help. Will be running Proflex thru attic, and come out the eaves. What do I need and how do I connect to black pipe so I can come down to wall to propane tank? Thanks in advance.
    NAD

    • @pro-flex7142
      @pro-flex7142  2 ปีที่แล้ว

      There are several ways to transition to black pipe. Given your scenario I might suggest using a stub out to transition past the eaves and tie into black pipe at that point. Feel free to give us a call should you have any questions during the process.

    • @dastick66
      @dastick66 2 ปีที่แล้ว

      @@pro-flex7142 Thank you. Can you let me know exactly what parts I need to order? Much appreciated.

    • @pro-flex7142
      @pro-flex7142  2 ปีที่แล้ว

      @@dastick66 Might be easiest to give us a call.

    • @dastick66
      @dastick66 2 ปีที่แล้ว

      @@pro-flex7142 what number do I call and who do I speak with? Thank you!

  • @AlexGicharu
    @AlexGicharu 8 หลายเดือนก่อน

    I am in Kenya and I want to learn more abt this and I have a shop I am gas vendor so I want to advance in the business

  • @micahfrd
    @micahfrd 3 ปีที่แล้ว +1

    Is this the same as homeflex?

    • @PJBeee
      @PJBeee 2 ปีที่แล้ว

      It is a different brand than homeflex. Note that the fittings are NOT compatible between brands.

  • @daniel.messick
    @daniel.messick 4 ปีที่แล้ว +1

    Can Pro Flex be used in RV's?

    • @JoseMunoz-df8xg
      @JoseMunoz-df8xg 4 ปีที่แล้ว

      VIKA2010

    • @pro-flex7142
      @pro-flex7142  4 ปีที่แล้ว +2

      Pro-Flex CSST is not approved for use in RV's or other mobile applications. The listing for CSST states: This standard applies to fuel gas piping systems using corrugated stainless steel tubing (CSST), intended for installation in residential, commercial, or industrial buildings...

    • @daniel.messick
      @daniel.messick 4 ปีที่แล้ว +1

      @@pro-flex7142 thanks for the reply, it's good to get that information from multiple resources. I emailed in and they responded same answer. Thanks again for the reply! Dan

  • @moevice8933
    @moevice8933 ปีที่แล้ว

    Where do you purchase the o-ring loader?

    • @PJBeee
      @PJBeee 13 วันที่ผ่านมา

      @@moevice8933 completely unnecessary. Use gloves if you think you'll get cut.

  • @pughbear9145
    @pughbear9145 3 ปีที่แล้ว +1

    Will I still have to use dope or does this eliminates that step?

    • @PJBeee
      @PJBeee 2 ปีที่แล้ว

      No dope or tape of any kind is needed, nor should it EVER be used on the CSST itself. Only on the NPT fittings should you use dope, tape, or whatever you usually use. For me, Pro-Dope works like a charm all by itself. (I don't get anything from anyone for mentioning it by name, and I have used it for years on gas pipe).

  • @leomerlovaz
    @leomerlovaz 2 ปีที่แล้ว +2

    2:47

  • @tracker1ify
    @tracker1ify 2 ปีที่แล้ว

    If another trade bumping it is going to make it leak then it ain't very good to start with

    • @PJBeee
      @PJBeee 21 วันที่ผ่านมา

      "Bumping it" is not going to make it leak. Nor is "bumping" the corrugated hose between your stove or dryer and the gas supply. But you should not be surprised that it's not as tough as black pipe.

  • @Rico-Suave_
    @Rico-Suave_ 2 ปีที่แล้ว

    Watched

  • @iamdavid420
    @iamdavid420 3 ปีที่แล้ว

    Is this what trac pipe used to be?

    • @pro-flex7142
      @pro-flex7142  3 ปีที่แล้ว

      No sir, Pro-Flex is a completely different line of CSST from the Tracpipe line.

  • @davidacosta4923
    @davidacosta4923 4 ปีที่แล้ว

    Can p r o flx be used under ground?

    • @pro-flex7142
      @pro-flex7142  4 ปีที่แล้ว +2

      Pro-Flex CSST is not approved for direct burial. It can, however, be run underground when sleeved by an approved conduit. Perhaps looking at our Pro-Poly underground offering would be a better fit for your application.

  • @swamplandoutdoors
    @swamplandoutdoors ปีที่แล้ว

    You talk to much we just wanna see how to do it, no history lessons or abc school scenarios. Less talking more walking

  • @marcusaurelius9631
    @marcusaurelius9631 2 หลายเดือนก่อน

    I do not recommend this product. If you are not a licensed Master Gas fitter you should NOT be doing gas work. Everything he says about metal to metal fittings is a crock of malarkey. They are by far a far superior product to proflex. I cant count the number of times I have found this crap with leaks all over it. Do not do gas work yourself!!! You are going to blow something up or burn it down and God forbid maime or kill somebody. Use and expert who is licensed and insured to install gas lines and I wouldnt give two cents for proflex gas line. Ask them to provide or show you their license too. I cant count the number of times of found leaks or incorrect fittings not apporved for pressurized gas that were installed by plumbers or homeowners that had no business doing gas work. Never let a plumber or electrician do gas work unless they are certified and licensed and insured!!! And I am a licensed Master Gas Fitter with 23 years of experience. Ive seen damn near eveything but still find ridiculous and dangerous stuff that people had no business doing all the time.

    • @PJBeee
      @PJBeee หลายเดือนก่อน +1

      I beg to differ. Pro-Flex CSST is not crap. I read the instructions carefully, got the card (I know, it's not hard to get that card), but my pipe and fittings all passed the town inspector's pressure test with flying colors (no drop in pressure at all). But I do agree that you had better know what you're doing with this stuff! Gas is dangerous. BTW when doing the work, which also included running 50 feet of 1" black pipe, I found a tiny gas leak on the utility side of the meter that had probably been there for years. The gas company tech thanked me for finding it and fixed it in a jif. And I had full permits for both the electrical and gas work that I did (installing a standby generator).
      It's now over 2 years later and no leaks of any kind.
      Also, to repeat what I've said before, Flak-Jacket insulation is pretty tough stuff. Obviously not as tough as black pipe, but neither are the flexible dryer and range hoses, which aren't as tough as Flak-Jacket. Just sayin'.

    • @marcusaurelius9631
      @marcusaurelius9631 21 วันที่ผ่านมา

      @PJBeee and your credentials are what exactly?? That you installed it one time?

    • @PJBeee
      @PJBeee 21 วันที่ผ่านมา +1

      @@marcusaurelius9631 No. I've installed it two times. And I would have the same comments if I'd installed it 100 times.

  • @siahmanjoe
    @siahmanjoe 2 ปีที่แล้ว

    It's not a bad product but it is a one time use so please stop using this as unions, sincerely plumbers everywhere 👍🏻

    • @jimmyjams5
      @jimmyjams5 ปีที่แล้ว +1

      I've zero issues disconnecting and reconnecting when working on the unit? Deff not a 1 time use. Lighter leak tested and all.

    • @PJBeee
      @PJBeee 21 วันที่ผ่านมา

      I don't get your point. Unions are probably more likely to leak than Flak-Jacket, when properly installed. The point of CSST, of course, is that it's flexible. It certainly ain't cheap.