slam sb ya sary folt ka bad bi yahi problem heating compriser sr we r shwoing to lotof tacntaion butt note solve so last repalac masheen like that so problem is diry filters chowq and also capri bolq mein problem start from use ceep gass and also lotof liqved charge thanks sr for yuor video my ny ap sy bohat kam siqa hy Allah kareem ap ki har mushkil ko asan farmy
Azam bhai ek sawal hay mera... 1.5 ton AC hay R22 wala....usme ek problem aya hay... Outdoor Fan lagta hay or compressor kabhe lagta hay or kabhe nahe....
Sir aaj kam pe gay the us mai kiya siplt ac hitachi ki hai us mai comprser bhi chal raha mangar cooling nahi kr raha us quarter ka bal bhi child chal raha hai howf ka baal norml chal raha kiya piroblm ho skti
Bhai har din noon me trip ho jata h aur 7 bje ke kareeb fir chalna lgta h Preshan ho gya hu, technician b Kuch nhi kr pa rhe, outdoor unit all day dhoop me rhta h, jis din barish ka mousam hota h us din bilkul sahi chlta h, please koi solution batao yrr
But sir mera split lg ac 4 ampiyar se kabhi uper leta hi nahi and cooling bhi km h baki usme sab kuch proper h tabhi problem ho raha hai Please reply jarur kijiyega
Bhai new AC liya hai Mene 13x16 room hai 1.5ton Ka inverter lgaya hai 4 person soty hai room me bahr Ka 31 hota hai night me 4 ghanty chalny ke baad 26 pe ata hai ? Is this normal please reply pehly non-inverter tha wo 20 tak bh jata tha lekn ye aisa lgta hai 24 tak hi jayga lekn Mene try Nahi Kiya 4 ya 5 ghanty Dekha hai tou 25 26 tak jata hai.....one more thing ajkal humidity 70-80% rehti hai jiski waja se feel like temp night me 35-36 show hota hai
Sir mera haier ka 1.5ton window ac h yei cooling to krta h but kbhi kbhi cut ho jata h compressor jhatke sei aur fir ac band krke backside paani dalke ac cooling achi krta h isme kya problem h iski service krva kei sahi hojaega ya koi aur issue h
@@fully4world mene usko chek kiya jab fan ki taraf se band karte he to speed fan ki slow ho jati he or jab compressor ki taraf se dhakte he to speed fast hi rehti he
Azam bhai ik split ac ka outdoor silver me hai mene silver rod se bhi tanka lagaya par laga nai.apkia kehte hai copeer k muqable me silver condenser ki kia life hai.kindly reply.its better or no
Azam bhai aap ki video dekh k apne 1 ton ac me gas refill ki he lakin liquid zyada chala gya he or compressor trip ho raha he koi hal bata do... please
Comoressor bhi sai hai or har cjez sahi phr bhi fault triping ka araha hai to ik fault aesa hai jo mere exp me aya or success experience howa ALLHUMDULILLAH.
Bhai is falt ka kya solution h mere bi samj nhi aa rha h kya key Compressor 2.5 se 6-7 Amper aate hi trip ho jata h Bhai mere mobile number 8619889723 plz bhai
azam bhai salam walekum...azam ji... hitachi ke 1.5 ton ke split ac se jabardast jhatka lagta hai aur ac cooling bhi nahi kar raha compressor bhi bahut awaz karta hai aur ye fault service karne ke baad aaua hai....please batayein kya fault ho sakta hai...
You should cover cabinet properly to pass air throughout all over the condenser while charging refrigerant, opening will effect discharge temp and compressor amps..
Sir jab compressor chal rha hai continue aur hum ac ko high nhi medium nhi low par chalayenge to kya ye electricity kam consume krega ya compressor on hai to high medium low kro electricity same consume krega ?🙏
Ac capacitor bhe change karwa liya aur ac gas bhe theek hai compressor dupahar mai trip krta hai raat aur subha theek chalta hai kya reason ho sakta hai?
Sir mere pass same compressor hai maine ise install kiya or ache se vaccum krke gas refill kiya to ye baar baar common chod deta hai or ek sound creat karta hai jaise safety release karta hai discharge line hot hoti hai but only two pipe of condenser get hot filter bhi cool ho jata hai capillary bhi or compressor fir common chod deta hai
Bhaiya g hum punjab se he Humne new split ac lena he Lekin shop wale bol rahe he ke Hum app ko scratch wala ac Kam rate ne dege jaise naye Wala total 35500ka he or scratch Wala 25500 ka he uska indoor New brand he compressor Me scratch he kya kare lele Ya nahi zarror batana
Agar 1.5 ton ac ka ampere 6.4 amps leta he aur cooling barabar he to useme aur gas topping karna chahiye kya? Rated current 7.3amps nameplate ke uper likha he.Ampere cum leta he to ho to gas cum he aisa mañana chahiye kya?
Sir agr compressor over hetting ho rha ho tb agr compressor oil nikal k new oil agr dal dy to kya compressor thek work krny lag jaye ga....plz inform me
Me ajj super general ac check kia pistan compressor he lekin bohat jada hit hota he or compressor bandh hota he lekin out door unit ka fan chalta he or tripping nehi hota, fer compressor automatically thanda hone ki bad 1 ya 2 minit chalke fer only compressor bandh hota he Lekin kia karne se sehi hoga (urgent ans)
@@ACS489 thanks for replying, ac power on karne ke baad jaise non inverter ka compressor uske ser temp pe aane ke baad off ho jata or baad me temp down jaane par vapis automatically on hota hai, vese hi inverter AC me ye process kaise hota, hai??
Sir woh toh meney bana diya lekin abhi jab paani lagaatey hain outdoor ko tab compressor uthha leta hai wesy nahi uthhata iska koi hal bataao please sir
Assalamualaikum Aazam bhai kaise ho ek problem ho rhi h ampier minus ho rhe h or compressor trip ho rha h 5 minute ke andar ampier 7.6 tak pahuch rha h fir minus hote hue ampier 5.1 aakar back pressure bhad rha h or fir ek minute bad ampier 3.2 akar compress band ho rha h kiya fault ho sakta h
Azam bhai ek carrier ka ductable ac h 5 ton ka uska compressor trip ho rha h 30 second chalne ke bad 22 23 amp leta h fir trip ho jata h fir 1 minute ke bad start ho jata plz batao azam bhai
AOA bhai mera a.c cooling to sahi kar rha hai per liquid pipe per nami nh aa rahi or pani walay pipe se pani nh gir rha suction pipe per nami aa rahi hai or thanda b hai per liquid pipe dry hai bilkul kia problem hai zara bata dain
aaj kal k ye AC kisi kaam k he nhi hain.. Purane wale AC jisme mota compressor aata tha wo ekdum badhiya they.
G ha bilkul
Thank you sir Allah ap ko jzai kher dey. Is video ki waja way bohot sa kharcha bacha
Share krdo video
slam sb ya sary folt ka bad bi yahi problem heating compriser sr we r shwoing to lotof tacntaion butt note solve so last repalac masheen like that
so problem is diry filters chowq and also capri bolq
mein problem start from
use ceep gass and also lotof liqved charge
thanks sr for yuor video my ny ap sy bohat kam siqa hy Allah kareem ap ki har mushkil ko asan farmy
Bro thanks very much
Really I'm trying hard to understand please help us subtitle it also in English so I can fully grasp all you are teaching
بہترین infomation
Share my video
Good yar 💗 thanks much needed info
Share krdo video
Good tiching karte hai 👍👌👌👌👌👌👍👍👍👍👍👍👍
Very informative channel. May Allah bless u
Bhot kuch naya janne ko mila
Azam bai me naya naya kam sekta ho ap boht ache tareky se batate ho
Gud video..evrything is true...nice job bro
Thanks sir bhut presan thi mai
Very nice video 👍 bhai
Share krdo video
Azam Bhai Kya aap Pakistan se ho ....
Very nice video sir 🇧🇩🇧🇩
Nice well done azam bhai
Azam bhai ek sawal hay mera...
1.5 ton AC hay R22 wala....usme ek problem aya hay... Outdoor Fan lagta hay or compressor kabhe lagta hay or kabhe nahe....
Capacitor khrab ho skta hai
@@fully4world fan wala??
Ya compressor wala?
Sir aaj kam pe gay the us mai kiya siplt ac hitachi ki hai us mai comprser bhi chal raha mangar cooling nahi kr raha us quarter ka bal bhi child chal raha hai howf ka baal norml chal raha kiya piroblm ho skti
Mashallah khuda Hafiz nice distribute in knowledge
Bhai har din noon me trip ho jata h aur 7 bje ke kareeb fir chalna lgta h
Preshan ho gya hu, technician b Kuch nhi kr pa rhe, outdoor unit all day dhoop me rhta h, jis din barish ka mousam hota h us din bilkul sahi chlta h, please koi solution batao yrr
But sir mera split lg ac 4 ampiyar se kabhi uper leta hi nahi and cooling bhi km h baki usme sab kuch proper h tabhi problem ho raha hai
Please reply jarur kijiyega
Bhai new AC liya hai Mene 13x16 room hai 1.5ton Ka inverter lgaya hai 4 person soty hai room me bahr Ka 31 hota hai night me 4 ghanty chalny ke baad 26 pe ata hai ? Is this normal please reply pehly non-inverter tha wo 20 tak bh jata tha lekn ye aisa lgta hai 24 tak hi jayga lekn Mene try Nahi Kiya 4 ya 5 ghanty Dekha hai tou 25 26 tak jata hai.....one more thing ajkal humidity 70-80% rehti hai jiski waja se feel like temp night me 35-36 show hota hai
Nice Sir aap se puchan tha aur aap video aplod kar deya very very much
Ager gas, fan and capicitor sab theek hun mager phr b trip ho tau kya masla ho sakta.?
Voltage Problem ki waja se bhi ye Problem hoti hai
Good information
Thanks
Sir mera haier ka 1.5ton window ac h yei cooling to krta h but kbhi kbhi cut ho jata h compressor jhatke sei aur fir ac band krke backside paani dalke ac cooling achi krta h isme kya problem h iski service krva kei sahi hojaega ya koi aur issue h
Capacitor Khrab ho sakty ha
Mera ac whirlpool ka he uska outdoor ka dhakkan utarte he to fan fast chalta he or band karte he to slow ho jata he pls help
Outdoor ka fan capacitor khrab ho sakta hai lemin dhakan sy fan speed ka koi talak ni hota
@@fully4world mene usko chek kiya jab fan ki taraf se band karte he to speed fan ki slow ho jati he or jab compressor ki taraf se dhakte he to speed fast hi rehti he
Zabardast ❤❤❤❤❤
Jazak Allah
Very good Bhai
Thanks
Thanx bro meri ac me ay problem hey abhi thik karke delta hu
Thanxx brother
Share krdo video
Aslamo alaikum bhai
voltige kam ho tu phr b asy ho sakta hy kaya
Asslam o alaikum
Sir aik issue ha plz us k liye puchna apsy
Thank you sir
Welcome
Azam bhai compressor se condenser coil ki setting kese hoti he ek video
Azam bhai ik split ac ka outdoor silver me hai mene silver rod se bhi tanka lagaya par laga nai.apkia kehte hai copeer k muqable me silver condenser ki kia life hai.kindly reply.its better or no
So nice 👍
Thanks share my video
Azam bhai aap ki video dekh k apne 1 ton ac me gas refill ki he lakin liquid zyada chala gya he or compressor trip ho raha he koi hal bata do... please
Comoressor bhi sai hai or har cjez sahi phr bhi fault triping ka araha hai to ik fault aesa hai jo mere exp me aya or success experience howa ALLHUMDULILLAH.
Bhai is falt ka kya solution h mere bi samj nhi aa rha h kya key
Compressor 2.5 se 6-7 Amper aate hi trip ho jata h
Bhai mere mobile number 8619889723 plz bhai
Low speed p trip ho raha hai . Full speed ya 500 watt se oper ok chal raha hai. Kia waja ho sakti hai?
Still no solution
azam bhai salam walekum...azam ji... hitachi ke 1.5 ton ke split ac se jabardast jhatka lagta hai aur ac cooling bhi nahi kar raha compressor bhi bahut awaz karta hai aur ye fault service karne ke baad aaua hai....please batayein kya fault ho sakta hai...
You should cover cabinet properly to pass air throughout all over the condenser while charging refrigerant, opening will effect discharge temp and compressor amps..
Sir apna whtsap number send koro
@@haseebhaseebqadeer8996 +97430882548
Yes top cover lagane ke bad pressure correct hoga
Any first amper checking good confriomed
@@ACS489s
Sir jab compressor chal rha hai continue aur hum ac ko high nhi medium nhi low par chalayenge to kya ye electricity kam consume krega ya compressor on hai to high medium low kro electricity same consume krega ?🙏
Nhi indoor fan speed low krrke nhi chalana chahea qq compresser over heat hoga or kuch na kuch problems create hoga
Agr electricity kam Karna hah to AC ko 24 degree me chalana hoga
@@rajtechnicaltech8046 28° aur high speed chalau to kesa rhega bhai ?
,sir empier batane ke liye thanks
sir rotry outdor chillar k lea estemal karsakte hai kya plz ans
Sir fan speed ka kaise pata chalega ki sahi hai ya kam hai ya jyda hai plz rply
Non inverter AC agar voltage kam ho to Kia aik yeh wajah Bhai kam cooling ki ho sakti hi ?
Nai voltage Kam Hai to cooling Ki upper effect nahe pada Ga Lakin unit start Hona ma problem hoga aur off hojaya ga
@@noormohammed5234
میرا نان انورٹر اے سی ٹرپ کر جاتا تھا
Ac capacitor bhe change karwa liya aur ac gas bhe theek hai compressor dupahar mai trip krta hai raat aur subha theek chalta hai kya reason ho sakta hai?
Fan capacitor ka bi masla ho sakta hai ya compressor k oil ka ya compressor ka
My fan start at full speed but after that it slows down changed all capacitor but no difference
Maybe its fam motor problem but after check we can sy any thing about it
Sir mere pass same compressor hai maine ise install kiya or ache se vaccum krke gas refill kiya to ye baar baar common chod deta hai or ek sound creat karta hai jaise safety release karta hai discharge line hot hoti hai but only two pipe of condenser get hot filter bhi cool ho jata hai capillary bhi or compressor fir common chod deta hai
Sir g kya hum ac or fridge compresser mai koi v gans daal sakte hai
Masaallah very good
Bhaiya g hum punjab se he
Humne new split ac lena he
Lekin shop wale bol rahe he ke
Hum app ko scratch wala ac
Kam rate ne dege jaise naye
Wala total 35500ka he or scratch
Wala 25500 ka he uska indoor
New brand he compressor
Me scratch he kya kare lele
Ya nahi zarror batana
Marine air condition ki puri maloomat bhi den please.
Mere ac ki condenser coil ka pipe tur gya hai to kya complete gas nikal gyi hogi... Puri gas padegi kya? Ac chalate hi coil bhut garm padh jaati h.
Ha g gas nikal gai hogi
Full gas daly gi
Thank you
Agar 1.5 ton ac ka ampere 6.4 amps leta he aur cooling barabar he to useme aur gas topping karna chahiye kya? Rated current 7.3amps nameplate ke uper likha he.Ampere cum leta he to ho to gas cum he aisa mañana chahiye kya?
Gash dalo
Aur sath main ice bhi aa rhi ho patli pipe par toh kya same reason hoga ya kuch aur problem h ?
bhai app ki tool kit bag ki video bhi bna do
Camlery ki wja se b ho skta hai jnab heet compressor
Sir machine bhi to chock ho sakti h jis wajha se amp badh sakte h
Or ek problem ho skti hai jo muze aayi thi..
Wo ye thi k capillary tube / drier filter choke jiske wajh se compressor heat ho raha tha
Hmm
Azam bhaijan suniye window AC ki circuit wiring ki koi video zrur banaiye plz bhaijan
Mghse pooch le kya prblm h
Haii
Sir indoor senior kharab ho to bhi a problem ata hai kaya compresar jadi cautap ho jata hai kaya
Sir agr compressor over hetting ho rha ho tb agr compressor oil nikal k new oil agr dal dy to kya compressor thek work krny lag jaye ga....plz inform me
السلام عليكم جمعہ مبارک
Azam bhai hamara outdoor chalte - 2 zor zor se hilne lagta h. Kya problem ho sakti h?
Useful video thanks
Sar spileet AC me 220 bolt kebil kyu di jati hai auot fuht se 220 Bolt diye jate hai spileet ac me 220 bolt kebel Di jatee hai ya nhi
Bhajan indoor outdoor unit ki assembly k liye body or parts kahan se purchase karte ho, Delhi ya gujrat
@@fully4world to kya hua, pak se h to, bhai to bhai h Saat samander paar kyon na ho
Sir 1.5ton ka ac hay SADA wala us may 70psi gas install hay btay normally gas install ketne hote hay
65 normal
Bhai Me apne ac ko heat pe chlata hon nai chal ta please video bnaye
Bro window ac ki pcb wiring ke bare me batao kaise kare
Ok
Aslam o Alikum Azam bhai mera Ac haeir ka out dor 1 mint main hi hitup hojata or trip hojata hai kabhi khud kai ghante chalta plz solve matter
Thanks Azam bhai
Always share sir
@@fully4world 4. Azm Bhai app ka no chayi
Agr 210 se 220 ho voltage fir bhi overhit hoga keya sir
बिल्कुल भी नहीं dusara प्रॉब्लम hoga
Me ajj super general ac check kia pistan compressor he lekin bohat jada hit hota he or compressor bandh hota he lekin out door unit ka fan chalta he or tripping nehi hota, fer compressor automatically thanda hone ki bad 1 ya 2 minit chalke fer only compressor bandh hota he
Lekin kia karne se sehi hoga (urgent ans)
Outdoor dhoop ma hoga
Azam bhai frg pe zang ka hal bten
A.c. onn karne par bahut thandie Hawaii aur halki rimjhim barish jaisa Hua.....kya danger sign hai ya normal....A.C. inn karun ya nahi...
Very nice
Mast
Kya gas kam hone per bhi aisa hoga
Thanks for your information, please help
Voltas ac ka compressor kitne me auto ON or Off hota hai?
1.5 ton 5 star
Please sir quetion समझ में नहीं आया। वोल्टेज या temperatur
@@ACS489 thanks for replying, ac power on karne ke baad jaise non inverter ka compressor uske ser temp pe aane ke baad off ho jata or baad me temp down jaane par vapis automatically on hota hai, vese hi inverter AC me ye process kaise hota, hai??
Dear azam brother, humara out door trip kerha hai gas kam ki hai aur ampere 7 1/2 hain aur volt meter per 220 volt arahy hai phir bhi trip kerha hai
@@fully4world exactly yeahi issue tha solve hogya capacitor change kiya hai
Bai iska cover laga k sb chk krein asy apko k6 b clear pta ni chly ga . Q k jb tk cover lgy ga phr pta chly ga gas kam ya zayada etc.
Sir agar compressor grm hokar kam nehi kartahe to kia karna cahiye?
Change kr dena chahiye
Sir compressor current maarta hai or tripp bhi hota hai paani daaltey hain toh dhua nikaLta hai
Compressor short ho gya ho ga
Sir woh toh meney bana diya lekin abhi jab paani lagaatey hain outdoor ko tab compressor uthha leta hai wesy nahi uthhata iska koi hal bataao please sir
Sir inverter ac ke compreshar ki speed slow q hoti h uske kuch reson bataiye plz
Bro
Because inverter ac compressor start 0 -1 Amper
Non - inverter ac star trek load 4 -5 Amper
Assalamualaikum Aazam bhai kaise ho ek problem ho rhi h ampier minus ho rhe h or compressor trip ho rha h 5 minute ke andar ampier 7.6 tak pahuch rha h fir minus hote hue ampier 5.1 aakar back pressure bhad rha h or fir ek minute bad ampier 3.2 akar compress band ho rha h kiya fault ho sakta h
اسلام علیکم
بھائی tropical compressor والا کونسا انورٹر اےسی اچھا ہے۔
Sir up ka phone number mil Sakta ha
Bhai humne split ac ki gas fill karwai last month bas uske bad se outer mai problem aa rahi hai
3bar fan blad tutt chuka hai
Compressor ko wash kr skty ha
Ha g lekin koi wire k uper pani na pary
Azam bhai ek carrier ka ductable ac h 5 ton ka uska compressor trip ho rha h 30 second chalne ke bad 22 23 amp leta h fir trip ho jata h fir 1 minute ke bad start ho jata plz batao azam bhai
Bhai muje batayo mera vi asay hi kar raha hai
Compressor konsa laga hai bata sakte hain? Konsi company ka?
Bhai 1.5 ka panasonic ka ac hai ac ka compressor chal raha hai lekin ges nahi ghomara hai kya problem hogi sir ji
Compressor ka msla
Out door stand ka megerment karna , use set karna, outdoor lagana, step by step ek video banayiye
AOA bhai mera a.c cooling to sahi kar rha hai per liquid pipe per nami nh aa rahi or pani walay pipe se pani nh gir rha suction pipe per nami aa rahi hai or thanda b hai per liquid pipe dry hai bilkul kia problem hai zara bata dain
Sir kahn pe hote hn ap shop he kia ap ki
Lahore
Nice video
Sir jis outdoor me rupay laga hota h us outdor me trip hota h 2 minute chalta h and band hojata hota problem honge
Capecitl check kro nhi to compresor gaya
Outdoor wash karen.condenser block hoga