Ilang Outlet Sa 30A Circuit Breaker

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 พ.ย. 2024

ความคิดเห็น • 395

  • @pauledwinariba3585
    @pauledwinariba3585 4 ปีที่แล้ว

    Nice master. Klarong klaro ang explanation. Sana. Mag upload kpa ng marami topic tungkol sa electrical. Marami ka natutulungan. Kudos sau. Master.

  • @geronimoisla1606
    @geronimoisla1606 3 ปีที่แล้ว

    Galing idol thank u sa pag share Ng iyung kalaaman na binahagi bilang isang electrician.

  • @jonasmorilla5370
    @jonasmorilla5370 4 ปีที่แล้ว +3

    Boss, ayos yun explaination mo pero ang napansin ko lang hindi kailangan 30amp na breaker ang gagamitin mo depende yan sa outlet na install mo bilangin mo outlet na install mo para yan ang reference mo kung ilan ampere breaker ggamitin mo separate jan ang motorized na appliances kagaya ng ACU or electric range. Nag dedepende kc yan din sa wattage na ma consume dun ka mag base sa PEC standard kc yan din ang point of reference ntin. Pasensya kana kung kailangan kong sabihin sayo na wag kang mag depende sa ampere sa kailangan na wattage ka magdepend base dun sa PEC standard bago mo compute. Pansin mo yun mga appliances may specification dun mo mkikta na kung ilan wattage ang capacity nya isa din yan sa reference ntin para sa computation ng loads. Kya nga gaya ng sabi mo may safety factor tyo tinatawag base sa PEC standard. Salamat sa pang unawa.

  • @scyther0194
    @scyther0194 4 ปีที่แล้ว

    Going to watch your lectures everyday.
    Date:

  • @jaysiapno659
    @jaysiapno659 4 ปีที่แล้ว

    Ser. Dag dag kaalaman.salamat for sharing ur knowledge

  • @ajcailian3226
    @ajcailian3226 4 ปีที่แล้ว +1

    FYR lang po Sir. According to NEC, ibig sabihin po ng 180VA per outlet does'nt mean per single outlet only. Ibig sabihin po sa NEC ay 180VA per yoke mapa simplex man duplex o triplex receptacle. And magbabago lang sya kung multiple device consisting of 4 or more receptacles per yoke equivalent to 90VA per receptacle na sya. 😊

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว +2

      yan din ang alam ko sir dati na per yoke(metal/plastic holder ng outlet) ang bilang hindi per outlet but mas safer kung gagamitin natin is per outlet may nakausap din akong engr. same we both agreed

    • @ajcailian3226
      @ajcailian3226 4 ปีที่แล้ว +1

      @@junauxtv I was just telling the real value of dupex, triplex, and single receptacle outlet which is 180VA. :) , if yan po yung pagkakaalam mo dati, yan pa din po un ngayon. :)

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Kaya hindi yan ang sinunod ko sir kasi may nabasa ako sa PEC, hanapin ko lng sir... nakalimutan ko lang paano pagkasabi doon...

    • @JeffreyManalo-h6s
      @JeffreyManalo-h6s ปีที่แล้ว

      Yan na nga Po matagal ko na iniisip. Cguro kung sa 180VA mo lang I compute Yun 3 or two gang wala naman kaso. Basta Tama Ang sukat ng wire at breaker. Kc Nung umatend Ako ng seminar. Sa 20A 13 PCs at sa 15A 10pcs na outlet Ang maximum kahit Ilan Gang, per pcs Ang basihan base sa itinuro sa Amin sa seminar. D nman sabay sabAy Gagamitin at iTrip safe nman Basta Tama Ang wire at breaker.

  • @rogerdefiesta3551
    @rogerdefiesta3551 4 ปีที่แล้ว

    Ayos na ayos bossing,maraming salamat👍👍👍❤❤❤

  • @azzungoth6731
    @azzungoth6731 4 ปีที่แล้ว +1

    30pcs outlet devide into two is 15 pcs. at devide mupa un into two, dahil ang two gang ay may dawalang peraso na oultet ang laman nun,
    so soma-total ay 7.5 pcs. lang dapat un, at nasa 3 outlets lang po un using two gang... loaded na po masyado un kung gagawin mung 10 to 12 pcs. outlet using two gang...

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      30 pcs po divide two kasi 2 gang kaya 15 2 gang outlet..hindi mo na dapat idivide ng two....

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว +1

      180va per outlet

    • @jbm9307
      @jbm9307 4 ปีที่แล้ว

      @@junauxtv sir anong article po kayo nagbase dito sa 180VA?
      Kasi sabi sa 2.20.2.5 (k), Receptacle outlets shall be calculated at not less than 180VA for each single or " FOR EACH MULTIPLE RECEPTACLE ON ONE YOKE.
      Dwelling unit po to. paclear po sir.
      thank u

  • @robertodomingo1264
    @robertodomingo1264 3 ปีที่แล้ว

    sir pag 30 amps breaker ang ginamit sa 3.5 thhn wire para sa mga outlet. Pag nag short circuit sunog lahat ang mga outlet hindi.pa mag ti-trip ang breaker. pero ung wire hindi masusunog maliban sa jumper ng outlet.

  • @AREM-w1h
    @AREM-w1h 2 ปีที่แล้ว

    Sir ang 180VA po na for each outlet is kahit 1gang, 2 gang sya or 3gang, 180va pa din po yung total va nya.

  • @johannaleiosita4725
    @johannaleiosita4725 5 ปีที่แล้ว +1

    Nice po sir mi natutunan naman po ako..tnx sa tutorial po.. sir ask ko lng mi nakapag sabi po kasi sakin yung mi bagong rules na daw po yung mga electrical company na bawal na daw po mag instal kahit sa bahay lng yung mga nc2 at vocational sa electrical pag walang lisensya. dpat daw rme. tutuo po ba yun sir? kakalungkot naman.

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว

      Pwd sir kailangan lang supervise kayo ng may license kaso hindi nasusunod yan sir..

  • @warrdudez25
    @warrdudez25 2 ปีที่แล้ว +1

    Boss pwd po ba size 14 at 12 thhn para 30amps breaker?

  • @johnjoebitangkol7649
    @johnjoebitangkol7649 4 ปีที่แล้ว

    So informative..thanks

  • @jovannipabia2738
    @jovannipabia2738 5 ปีที่แล้ว +1

    Unang,una,,present,,Good job sir Jun,,

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว

      Yown....tnx sir...

  • @gepalado6163
    @gepalado6163 3 ปีที่แล้ว

    Thanks for the info..☺️
    San po b puedeng bumili ng mounting screw for circuit breaker d2 s Pinas?

  • @gienav0992
    @gienav0992 2 ปีที่แล้ว

    Sir pa explain naman po nung for further expansion? Bakit ganyan??

  • @bennaraoarao5471
    @bennaraoarao5471 5 ปีที่แล้ว +1

    Thanks very educational sir more videos to come

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว

      Maraming salamat po sir

  • @opecons
    @opecons 3 ปีที่แล้ว +1

    Boss ano ba ang rating ng mga outlet na ilagay mo dyan. Kasi sa PEC table 2.10.2.4 (B) kun 30A ang CB rating, ang outlet din ay 30A rating. Kilangan match ang rating. Kun regular outlet ilagay mo mababa ang rating nun tapos lagyan mo ng 5.5 mm2 .

  • @soroanjonnel9484
    @soroanjonnel9484 7 หลายเดือนก่อน

    Good day po master, salamat po,if masasagot.master tanong kulang po kung dapat pobang lang yang ng tag iisang cb .ang mga ref,.12pong piraso ang kakabit kupo,. salamat po

  • @wilsonpadon
    @wilsonpadon 6 หลายเดือนก่อน

    2:34 Doon sa Chart po ninyo na sizing wire and circuit breaker, yung 30A 5.5 po nakalagay don ngayon 3.5 na?

  • @pit3835
    @pit3835 4 ปีที่แล้ว +1

    sir salamat sa mga ganitong enlightment marami kami natutunan. pero minsan di na ako nkakasunod
    bakit po maderate ang amp capacity ng 3.5 pag madami na ang wire sa isang race way dahil magreact ang kurente na wire pag madami na sila magkagulo?

    • @pit3835
      @pit3835 4 ปีที่แล้ว +1

      para solusyunan yan pedi nalang ihiwalay ang conduit ng 3.5 sa ibang wire para ma maximize mo. bali hindi ko nalang sila pagsamahin na conduit mula sa panel board?

    • @pit3835
      @pit3835 4 ปีที่แล้ว +1

      sana po masagot sir .God bless

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Kasi sir pag madame na ang wire nag gegenerate na po ang init, kasi ang maximum na ampacity ng wire good for ambient temperature lang po sir na 30°C kaya po sya nadederate

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Pwd naman po sir ihiwalay ng conduit

    • @pit3835
      @pit3835 4 ปีที่แล้ว

      yes sir
      yea sir.
      salamat po talaga sa sagot po.
      madami kapo natutulungan na kagaya ko. Happy new year..

  • @CasterbalTV
    @CasterbalTV 5 ปีที่แล้ว +3

    *Sir, pwede magrequest? pwede po tutorial ng pano gumamit ng multi-tester.. Hehe =)*

  • @remarsbaldado5202
    @remarsbaldado5202 3 ปีที่แล้ว

    Sir, pwd magtanong kung ano ang Common n breaker n ikabit s bahay n maraming appliances thanks.

  • @shirwensanantonio5196
    @shirwensanantonio5196 3 ปีที่แล้ว

    Boss ilang ilaw at ilang saksakan ang pewedeng ikabit sa 30 amperes...

  • @romelpogilokano
    @romelpogilokano 4 ปีที่แล้ว

    Sir ang pagkakaintindi ko 30amps x 230vac=6900 watts divide by 180watts as per NEC=38 outlet. Sir ang 90 degree temperature ay para lang sa terminal temperature o mga ambient temperature o derating. Dapat sir make it simple huwag ng idagdag ang mga ibat ibang derating factor.

  • @willtech1759
    @willtech1759 3 ปีที่แล้ว

    Sir ano po ba advisable single breaker n 30A or 2 Branch panel sa maliit n bahay n my 2 rooms at isang maliit n kitchen at living room.

  • @eljensonon6484
    @eljensonon6484 4 ปีที่แล้ว

    Pwedi bang gawing homerun ung flatcord

  • @walterdula3347
    @walterdula3347 3 ปีที่แล้ว

    Good morning ser pwede dw po ba pagsabyin ang wire na no.12 at 10 sa 30amps breaker

  • @NorbaiA.Patamama
    @NorbaiA.Patamama 9 หลายเดือนก่อน

    sir,sa apat na brances a20A at dalawang 15A ano ang pweding main breaker na gagamitin.

  • @chrislertv3613
    @chrislertv3613 ปีที่แล้ว

    Sa 30amp Po ba kaya ba ang 1 ref for cold drinks at 2 na cheller for frozen food. Isang breaker lang Po gagamitin ko 30amp? Thanks

  • @shechinahcomiso217
    @shechinahcomiso217 4 หลายเดือนก่อน

    hello po, pag sa refrigerator po ba dapat may circuit breaker rin?

  • @samuelreyes7032
    @samuelreyes7032 4 ปีที่แล้ว

    Good day boss ask ko lang ung isang outlet with 2 gang each socket ilan appliance pede I connect .usually ginagawa.ntin isang outlet connect ntin extension wire with 6 socket then connect tv.home theater subwoofer and DVD player ?? Ok lang ba yun .or mas safe isang outlet connect ko automatic voltage regulator then connect extension wire with 6 socket jan ko connect ung tv home theater subwoofer etch.

  • @mixtv6236
    @mixtv6236 4 ปีที่แล้ว

    matanumg lang sir.. 2 co 1 Lo pinagsama. 3.5 feeder 3.5 co 2.0 LO 15 AMP CB OK lang ba

  • @shawnrenz9610
    @shawnrenz9610 3 ปีที่แล้ว

    sir pwede po ba gamitin 2.0mm2 na THHN 90 degree para sa 20/25 Amp breaker

  • @jessiebutcon9805
    @jessiebutcon9805 2 ปีที่แล้ว

    Boss Yong para SA outlet na breaker ang ginamit Namin at 30 amp pwidi ko ba saksakan ng ref Bali rated power input 140 watts rated current 1.0 A

  • @albertrubian2971
    @albertrubian2971 4 ปีที่แล้ว +1

    Sir june my tutorial n po b kyo ng MCB connection?

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Wala pa po sir....pag meron na po sir...gawa po tayo ng video

    • @albertrubian2971
      @albertrubian2971 4 ปีที่แล้ว

      Ok po sir abangan po namin...naghanap nga po aq sa mga upload nyo cnigurado ko lng baka kako di ko lng napansin...god bless to all

  • @anythingaboutlife7827
    @anythingaboutlife7827 3 ปีที่แล้ว

    kung mag dagdag ba para sa tv.ref.electrifan..ilang amp ang dapat jan?

  • @jordanbalinquit1487
    @jordanbalinquit1487 4 ปีที่แล้ว

    Sir ask LNG po if pwd ikabit ang single MCB direkta sa pader?

  • @jrsalarda9380
    @jrsalarda9380 4 ปีที่แล้ว

    Sir new. Subs. Po ako.. Ask ko lng pwd ba isaksak jan ang inverter welding machine?

  • @alvinlimjuico2219
    @alvinlimjuico2219 4 ปีที่แล้ว

    Idol ask ko lang ilang amp ng circuit breaker sa 1.5hp spit type inverter? Tnx more power po

    • @Pocholo910
      @Pocholo910 3 ปีที่แล้ว

      Pwde na 15amps sir sa 230ac volts

  • @sonnytv9683
    @sonnytv9683 3 ปีที่แล้ว

    Bro ask lang Yung nabili Kong RCCB 40 amps 50 Hz puede ba syang magamit ?

  • @jomarcalleja6494
    @jomarcalleja6494 3 ปีที่แล้ว

    Sir, nka RCBO po Yung breaker ko, 32amp. Pwde po sa 3.5mm² #12 , at Kya po Kya nya Ang ref ska washing...

  • @juniorcajes4210
    @juniorcajes4210 4 ปีที่แล้ว

    sir ano tamang outlet para sa saksakan ng motor or ref para sa kitchen outlet, sabi mo di yan pede sa ganun?

  • @bensanchez313
    @bensanchez313 3 ปีที่แล้ว

    Thanks papz

  • @mhaicasugbo3135
    @mhaicasugbo3135 4 ปีที่แล้ว +2

    Sir tanong ko lang,pag gumamit ng ref ,washing machine,or ac,kailang ba malaki rin yung wire?or okey na ang 3.5mm?at yung cb nya pwd 20amps lang?

    • @AREM-w1h
      @AREM-w1h 2 ปีที่แล้ว

      As per PEC po motor loads is minimum 30A na CB, if 30A 5.5 sq. mm. Pero po sa pagkakaalam ko REF and washing machine pwede sa 20A na CB and ACU minimum 30A

  • @zippelah5779
    @zippelah5779 4 ปีที่แล้ว

    Brad paano ba malaman natin na nag karuon Ng voltage drop @ anung tools Ang gamitin para sa check ? Kung nag karuon Ng voltage drop.

  • @PangasinanVlog
    @PangasinanVlog 3 ปีที่แล้ว

    Ano po bang kinalaman ng bilang ng power outlet sa load na gagamitin sa cb?parang ang sagot sa tanong mo,nka dependi sa load or appliance na isasaksak mo sa outlet..pwd pa ung ilang ilaw dahil load mismo ung ilaw...pero sa outlet🤔..depende tlga

  • @ReynaldoDempo
    @ReynaldoDempo 4 หลายเดือนก่อน

    ang ibig sabihin po ba ng 180va ay 180watts? So kung ganun mali ba na isaksak ang electric drill na 850watts? Or Plantsa na 1000watts?

  • @pauljohndevera1989
    @pauljohndevera1989 7 หลายเดือนก่อน

    Boss dba 20 amp. Ung breaker ng outlet. Tpos halimbawa 10 outlet ung kinabiy mo.. tpos ung sinaksak mo sa isang outlet. 6 amp na appliances. Tpos sinakskan mo ung tatlo outlet na mag kakahiwalay .bali 18 amp na laht. So panu ung dlawang outlet na baknte? D n ba pede skskan? I mean mg ttrip na?

  • @fharnizaasbi9080
    @fharnizaasbi9080 3 ปีที่แล้ว

    Sir sa 20 amps breaker na may 8 gangs pwede po vha i direct ang aircon na 0.5 HP sa Gang oh gagawa pa ng single breaker para sa aircon?

  • @marknorial8221
    @marknorial8221 4 ปีที่แล้ว

    Sir may tnong ako. Meron pong existing 30amp CB sa panel board mmin intended pra sa .5hp na aircon. Ang tnong po is, kung pwde po ba kmuha din ng supply don sa 30amp CB pra sa isang 2gang outlet at isang lightbulb lng po??

  • @moonsun815
    @moonsun815 3 ปีที่แล้ว

    hi sir baguhan lang po ako sa electrical system design. tanong ko lang po how come na pwede tayo magplug ng 400 W na appliance like rice cooker kung ang max per outlet natin ay 180VA lang po

  • @markdonardmanalo6912
    @markdonardmanalo6912 4 ปีที่แล้ว

    Sir anu dapat po gamitin 20A o 30A na CB may 1hp aircon at 4 convenience outlet tnx po..

  • @aymanabantas2309
    @aymanabantas2309 3 ปีที่แล้ว

    sir sakto po ba yang 30amp sa apat na two gang outlet tapos 3 ilaw( 2 bulb light isang fluorescent light) isang 3 gang switch. mga appliances po ay 2 computer isang 1.5hp na aircon isang maliit na ref tapos electric fan tapos tv.

  • @gilboy4205
    @gilboy4205 4 ปีที่แล้ว +1

    Salamat bro

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Maraming salamat din po sir

    • @gilboy4205
      @gilboy4205 4 ปีที่แล้ว

      Idol jun.. Saan ho ba natin mabibili ang libro ng PEC guidelines?

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Sa IIEE office po sir

    • @gilboy4205
      @gilboy4205 4 ปีที่แล้ว

      Ano ho ba sabihin IIEE idol jun? Nandto ba yan sa manila? Naghanap kc ako sa national bookstore pero wala ehh

  • @jestoniortiz1419
    @jestoniortiz1419 5 ปีที่แล้ว +1

    Sir yung ngang 3 phase installation ang next tutorial mo...salamat

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว +1

      Soon sir...

  • @shechinahcomiso217
    @shechinahcomiso217 4 หลายเดือนก่อน

    sir okay lang po ba na ang refrigerator at washing machine namin ay isang outlet lang pero may dedicated na circuit breaker at ilang amperes po kaya ang need?

  • @catherineaysoncasiano9683
    @catherineaysoncasiano9683 4 ปีที่แล้ว +1

    Sir ilang cb po ba kailangan kapag mayron ref, frezzer,washing machine, flat screen na tv,rice cooker,electric fan.7 lights.salamat poh

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว +1

      Pwd na po 6 branches jan mam..

  • @jessmetalworks6439
    @jessmetalworks6439 5 ปีที่แล้ว +4

    Sir pwede ba yan sa saksakan ng ref,, at heater

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว

      Pwd sir...wag lang masyadong malaking ref

  • @crissclaud570
    @crissclaud570 3 ปีที่แล้ว

    Sir pwede na.po ba 30ampers ang circuit breaker tapos dalawang 1.5 hp na aircon at isang 1.5 hp na water pump .tapos ang wire na gagamitin ko duplex number10 ang main at..at galing sa mga motor na wire ang gagamitin ko duplex number12 na wire un ang idugtong ko sa main na duplex number10

  • @wilsonnatividad8932
    @wilsonnatividad8932 4 ปีที่แล้ว

    Sir pwd bng gumamit ng 12 size n wire sa metro patungo sa panel box ung kc ang gamit q .

  • @aemon16
    @aemon16 4 ปีที่แล้ว +2

    sir tanong ko lang po. diba 6 hole lang sa 150sqm na bahay? pano po un sir
    3 aircon 1.5hp
    1 range
    2 ref
    1 microwave
    3 3000watts powered amplifiers..
    sana sir makagawa kayo video or masagor tanong ko. salamat

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      May computation din po sir for more than 6 branches na 150sqm na floor area

  • @ryanmijares4357
    @ryanmijares4357 4 ปีที่แล้ว

    good day sir. pwde bang mag connect ng 30amp. na breaker sa refrigerator at may t.v pwde bah..!!

  • @flordelima8896
    @flordelima8896 4 ปีที่แล้ว

    sir tungkol naman sa high in low ang koryente paano magawaan nang paraan para permis ang koryente

  • @krisnansanchez1282
    @krisnansanchez1282 4 ปีที่แล้ว +1

    Sir good evening po. Bago lang po ako sa channel mo. May tatanong lang po ako kung ok po ba yung #12 wire tapos main is 30amp may 9 na ilaw at may 6C.O at may ref ok po ba na i plug yung reff sa co? Single CB lang po siya

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      kaya yan sir kahit 20a lang para mas safe po

  • @ninotv3735
    @ninotv3735 4 ปีที่แล้ว

    Boss ilang amp, ang kaylangan kung meron ako repidjarator at tatlong outlet,

  • @dennsmotovlog2376
    @dennsmotovlog2376 2 ปีที่แล้ว

    Kaya b 30ampers pag maglagay ng 3,outlet tas washing machine tv electricpan

  • @junfabros9950
    @junfabros9950 3 ปีที่แล้ว

    Sir jun tanong ko lng po,itong bahay po namin ang gamit po namin ay ref,computer,tv at mga electric fan,ilang amper po ba ng breaker ang dapat kong gamitin?at anong wire gamitin?

  • @lesterdolpina3590
    @lesterdolpina3590 4 ปีที่แล้ว +1

    good morning sir jun. sa 30amps pwede nba pag smahin ang c.o at lighting outlet? and with separate wire na sa c.o 12duplexwire at 14duplex sa lighting? Single circuitbreaker lng po ggamitin q.

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      sir ganto po ang purpose ng cb natin protection po sa wire kaya hindi tayo pwdng bumaba pa ng size ng wire sa 3.5mm yan lng po ang may allowable na ampacity na pasok sa 30a

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      ang #12 duplexwire sir is hanggang 20a lang po yan...

  • @rbh0483
    @rbh0483 4 ปีที่แล้ว

    Sir tanong ko lang ilang amp.puede ko gamitin sa main breaker papunta sa breaker ng switch at outlet.tnx po God bless

  • @jonijaiddin5049
    @jonijaiddin5049 3 ปีที่แล้ว

    Tanung ko lng po , pwd ba ang 30 amp's sa 8 malaking frezer sa 3 co gamit na wire e 3.5

  • @kaboboypalaboy6218
    @kaboboypalaboy6218 4 ปีที่แล้ว +3

    Boss ask ko Lang pwede ba by pass,30amps main breaker
    No.14 wire tas nandun na lahat ilaw at outlet
    Sabi nila kung itotal mo Yung load Kya naman tsaka yun Lang Kya Ng budget pansamantagal, please reply thanks

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว +1

      Sabi nila sir...but may sinusunod kasi tayo na Philippine electrical code sir...kung mag #14 po kayo sir...15 amps lang ang gagamitin nyong breaker...hindi rin po sya pwdng kabitan ng outlet kasi ang standard size para sa outlet is 20amps #12 na wire...sir sa Electrical safety po lage unahin natin...unsafe po ung sinasabi nyo sir

    • @kaboboypalaboy6218
      @kaboboypalaboy6218 4 ปีที่แล้ว

      @@junauxtv sir ask ko lang po
      Yung water pump po every time na aandar, Yung ilaw kumukurap po
      Anu po Kya Ang problema? thanks...

  • @anamaepanilag4802
    @anamaepanilag4802 4 ปีที่แล้ว +1

    washing machine sir pwede ba isaksak dyan...or need talaga bukod na breaker at wire ang washing machine...t

  • @regaladodeleon1866
    @regaladodeleon1866 5 ปีที่แล้ว +1

    Sir ask ko lang po uli..ilang ampers na breaker dpat gamitin sa 1h.power na aircon at .5 h.power..dpat din po ba magkaiba sila ng breaker..ty po s riply

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Same mo na sir na 20amps

    • @arnelnaing1001
      @arnelnaing1001 4 ปีที่แล้ว

      kahit 5hp AC sir pede 20 amp..? 🤔..
      kala ko 3 phase na un..
      experience lng kasi aq natuto sir..
      sa vid mo lng aq kumukuha theory😄

  • @francisgarcia2086
    @francisgarcia2086 4 ปีที่แล้ว +1

    Tol minsan magulo ka mag paliwanag😅 minsa Lang naman.😊

  • @jhunnabacahin1605
    @jhunnabacahin1605 4 ปีที่แล้ว

    Boss ang main breaker ko ay 30 ampere ang size ng wire na ginamit sa bahay ay 12(stranded) hindi naman po umiinit yong wire at yong breaker eto po yong mga ginagamit ko sa bahay may ref na 2 door 3 tv n lcd (32 inches) 5 electric fan 1 water dispenser(hot/warm) 1 rice cooker 1 washing machine 10 LED bulb ( 15 watts ) 1 PC 1 component minsan gumagamit ng plantsa at kung sakali mag dadagdag pa ako n room type 1HP n aircon tama po ba yong breaker ko at size ng wire

  • @jrbros6276
    @jrbros6276 4 ปีที่แล้ว

    Sir puede bang mag install ng combinition line to line at saka line to neuatral tapos mag install ng 110v sa outlet

  • @dodoicoh7288
    @dodoicoh7288 5 ปีที่แล้ว +1

    Sir saan kinuha ni PEC yung 180VA at pano kinompute yun?

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว +1

      Standard yan sir for small load appliance...no provided computation sir sa PEC

    • @dodoicoh7288
      @dodoicoh7288 5 ปีที่แล้ว

      @@junauxtv ahh salamat sa info sir.

  • @ernestdavis6336
    @ernestdavis6336 4 ปีที่แล้ว

    Sir ask ko lng po kung tama set up ng circuit breaker ko.
    Main 60A
    Outlet 30A #12 with additional extention cord.
    Heater 30A #10
    Switch 30A #14
    Aircon 1.5 hp 30A #10
    Thanks po. Stay safe. GOD Bless 🙏

  • @balljack1983
    @balljack1983 4 ปีที่แล้ว

    Pero ung thhn na 90'c na wire... Ok lng din na gamitin sa 20amp para sa aircon o kya sa mga outlet?

  • @ronronromo5776
    @ronronromo5776 4 ปีที่แล้ว +1

    may limitation po pag dating sa haba ng wires and outlet? if meron gaano lang po kahaba ang recommended? thanks in advance po

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      pang residential lang po ba sir?

    • @ronronromo5776
      @ronronromo5776 4 ปีที่แล้ว

      @@junauxtv anu po ba advisable sa residential at mga building or warehouse na? Thanks in advance po uli.

  • @garydabu1287
    @garydabu1287 4 ปีที่แล้ว

    sir ask ko pwede bang gamitin yun dc breaker sa haus .tnx

  • @surasura6333
    @surasura6333 2 ปีที่แล้ว

    How about sa switch not included ba sa for 30A circuit breaker?

  • @ianrosal1235
    @ianrosal1235 4 ปีที่แล้ว +1

    sir tanung ko lang pwd ba ang 20amps na circuit breakes sa aircon na 0.5hp na may 580watts? salamat sa sagot idol

    • @12Novelist
      @12Novelist 3 ปีที่แล้ว

      580 watts lng po yan eh pwedeng pwede po yan. :) 20amp x 80% = 16amp. 16amp multiply nyo po sa 230v para mkuha nyo ung watts total. which is 3680watts total capacity ng 20amp na breaker.

  • @jehylquinonestv9940
    @jehylquinonestv9940 4 ปีที่แล้ว +1

    sir tanong q lang po,, ilan ang sub breacker na gamitin sa 60amps na main breacker? tnx po...

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Depende po sa load ng bwat branches

    • @merjunatim9121
      @merjunatim9121 4 ปีที่แล้ว

      "9" 3 x 30A, 4 x 20A, 2 x 15A

    • @merjunatim9121
      @merjunatim9121 4 ปีที่แล้ว

      Main [60A] [30A] ACU Rm 1
      ACU Rm 2 [30A] [30A] ACU Master
      CO 2nd Flr [20A] [20A] CO Grnd Flr
      L 2nd Flr [20A] [20A] L Grnd Flr
      Ref [15A] [15A] Heater 2nd Flr

  • @arnellgalliano5366
    @arnellgalliano5366 5 ปีที่แล้ว +2

    master ok lng ung l.o pd b 3.5 wire na gagamitin ko pati na din sa swich..at kung ok lng ba ung main ko 60amp at l.o 30 amp at c.o 30 amp....

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว

      Mas maganda sir if nasa standard tayo 15A lo 20A co

    • @arnellgalliano5366
      @arnellgalliano5366 5 ปีที่แล้ว

      Jun Aux TV tapos ung main ko is 40.pero pd ko na po b gamitin ung 3.5 sa l.o at swich

  • @ashleysfoodstravel4747
    @ashleysfoodstravel4747 4 ปีที่แล้ว +1

    Sir pano yung 2freezer 1 chiller at isang ref pwede ba sa isang 30 amp na breaker yun

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      May wattage po ba mam na nakalagay?

  • @pilardolarroza9250
    @pilardolarroza9250 5 ปีที่แล้ว +1

    Sir singit ko lang tanong ng manugang ko. Ngpalit xa from 2 gang to 3 gang na switch walang mapagkuhanan ng neutral pero duon dw xa kukuha ng neutral sa ilaw mismo na malapit sa ikatlong ilaw. Gagana ba yong ikatlong ilaw nia. Ano sa tingin mo sir? Thanks a lot and more power!

    • @junauxtv
      @junauxtv  5 ปีที่แล้ว +1

      Yes po sir...gagana po iyon kasi ang dadaan ng switch is hot wire lang talaga dapat...

    • @pilardolarroza9250
      @pilardolarroza9250 5 ปีที่แล้ว

      @@junauxtv MAraming salamat sir

  • @bagwischannel3073
    @bagwischannel3073 3 ปีที่แล้ว

    Sir, 30amp po gamit ko na breaker pra sa c.o ko.. ok lng po ba ung size 12 na wire? May 2 aircon po aq tas 10 na c.o

  • @kinnit2460
    @kinnit2460 3 ปีที่แล้ว

    Sir pwede po ba 30amp ang main CB, tapos kabitan ko ng 30 amp ulit para sa 2 outlet ng power tools, at 20 amp para sa 4 na ilaw at 3 convenience outlet?

  • @rogercada7741
    @rogercada7741 4 ปีที่แล้ว +1

    Magandang araw boss, magtatanung lng po. Balak ko kc palitan ang lumang planka namin ng main breaker, ilang amp. Po ang pwede na ipapalit

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      depende po sir sa size ng wire nyo sa service entrance sir...kung gusto mo taasan sir..need mo din palitan ang wire mo sa service entrance

    • @rogercada7741
      @rogercada7741 4 ปีที่แล้ว +1

      @@junauxtv salamat sa reply boss,

  • @denispaulino2107
    @denispaulino2107 4 ปีที่แล้ว +1

    Sir ,on off using single push button wiring

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      noted po sir..ganyan gamit sa pinagtrbahoan ko sir..soon po sir.

    • @denispaulino2107
      @denispaulino2107 4 ปีที่แล้ว

      @@junauxtv thank you sir

  • @giminivlogofficial
    @giminivlogofficial 11 หลายเดือนก่อน

    Sakaling isama ang ilaw Jan sir Ilan nman ang pwd kng nagsama ang outlet at ilaw Jan sa 30ampere

  • @bonz23100
    @bonz23100 4 ปีที่แล้ว +1

    Sir tanong ko lng po kung ok na sa 30ampers, ang gmit kung wire ay 5.5mm2, mayron pong 5 outlet na 3gang, tpos 4 na switch pra sa ilaw. At pwde na po ba ito ng appliance gaya ng ref at washin machine..slmt po sa sagot

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Single circuit breaker lang po ba sir?

    • @c.eassassin5546
      @c.eassassin5546 4 ปีที่แล้ว

      ganyan din sakin sir.. yun na po main breaker q sir sa bahay isa lg po sya sir.. ok na po ba yun sir? 30amp din sir...

    • @bonz23100
      @bonz23100 4 ปีที่แล้ว

      @@junauxtv yes sir, single crcuit breaker lng po

  • @julcalabio
    @julcalabio 4 ปีที่แล้ว

    Maiba lng ako sir...kng 30amp ang circuit Breaker ko mga ilang watts ba kaya niyang supplayan ...mga amplifiers lng nmn gagamitan ko

  • @diaganjerome2390
    @diaganjerome2390 4 ปีที่แล้ว

    Sir tanong ko po ilang amperes po ng main breaker ang puedeng ilagay sa 5 na 20 amperes branches breaker? salamat po

  • @Yurinabuch88
    @Yurinabuch88 4 ปีที่แล้ว

    Dito sa bahay Naman 40 A Kaya mas Mura ang binabayaran naming kuryente but I’m talking about my house dito sa Japan

  • @recommendedforyou794
    @recommendedforyou794 4 ปีที่แล้ว +1

    Sir tanong kulang po, pwd ba gamitin 30amp main breaker tas gamit sa 12L.O 10watts,5C.O?

    • @junauxtv
      @junauxtv  4 ปีที่แล้ว

      Single circuit breaker lang po ba to sir...if yes.....20 amps nlng gamitin mo sir

    • @recommendedforyou794
      @recommendedforyou794 4 ปีที่แล้ว

      @@junauxtv yes sir

    • @recommendedforyou794
      @recommendedforyou794 4 ปีที่แล้ว

      Yes sir pero 12lights, 5C.O.may ref at computer kasi sir

  • @rodolfomangalino
    @rodolfomangalino 3 ปีที่แล้ว

    Hiwalay ba saksakan ng aircon at plantsa

  • @johnaaroncustodio9238
    @johnaaroncustodio9238 4 ปีที่แล้ว

    Sir new sub here. Ask ko lang po based sa video niyo po. Gamit po sa bahay namin is 30 Amp - 12awg for 13 C.O. Ayos lang po ba ito sir? Thank you!