Where PVC Conduit Cannot be installed 352.12 Uses not permitted.

แชร์
ฝัง
  • เผยแพร่เมื่อ 16 ต.ค. 2022
  • We offer the #1 Electrical Exam Prep Program
    FREE VERSION
    electricalcodecoach.com/free-...
    PRO VERSION
    www.electricalexamcoach.com/m...
    USB OR DVD PROGRAM FREE SHIPPING!!
    electricalcodecoach.com/shop/...
    400x Practice Exam PDF Download for only 14.99 electricalcodecoach.com/shop/...
    2017 Tabs with FREE SHIPPING
    electricalcodecoach.com/shop/...
    2020 NEC TABS with FREE Shipping
    electricalcodecoach.com/shop/...
    2023 NEC TABS with FREE SHIPPING
    electricalcodecoach.com/shop/...

ความคิดเห็น • 19

  • @dubsonzapata9739
    @dubsonzapata9739 ปีที่แล้ว

    Awesome quick lesson...thank you for always encouraging, and willing to add value to people!!🙌🙏

  • @Gruntled2001
    @Gruntled2001 ปีที่แล้ว

    Thank you, Coach 💪🏼🙏🏼

  • @jrpritchard1622
    @jrpritchard1622 ปีที่แล้ว

    thanks coach for the tips today

  • @andrewhylton4780
    @andrewhylton4780 ปีที่แล้ว

    I appreciate this lesson.

  • @jamiebrock7157
    @jamiebrock7157 ปีที่แล้ว +1

    thanks again

  • @MrKen59
    @MrKen59 ปีที่แล้ว +7

    Wow / was looking at the “ambient temp” section of 50 degrees C (122 f) and that would make it off limits to many attics. Before I replaced shingles with metal, I measured my attic at 135 degrees in the summer. It’s easy to look at 60-c or 90-c and blow it off, but that’s not unreachable in some areas of a home. Thanks for todays lesson.

  • @johnwalker890
    @johnwalker890 ปีที่แล้ว +1

    PVC is the best for underground and outside use. Didn't get the new Handbook 2023 code book yet, working on it.

  • @babounce100
    @babounce100 ปีที่แล้ว +2

    Passed my test
    Thanks coach

  • @jerseyjoe9393
    @jerseyjoe9393 ปีที่แล้ว +1

    Hi there Coach- I ran across this the other day.
    Can you enlighten us about the newer ProPress plumbing fittings and their bonding properties?
    I had a water heater replacement situation and was wondering about the bonding effectiveness of those copper ProPress fittings. Thanks!

  • @samash1704
    @samash1704 ปีที่แล้ว +7

    What's special about a "theater"?

  • @joseverges1955
    @joseverges1955 ปีที่แล้ว

    Do you have a educational video of PVC conduit shrinkage calculations. There's a table on the PVC chapter but I'm having a hard time understanding.

  • @ronaldnaeyaert3653
    @ronaldnaeyaert3653 10 หลายเดือนก่อน +2

    What does "subject to physical damaage" imply. I am runnong a generator inlet thourgh 3/4" PVC. Some of the conduitwill be on the outside all of a brick house and some of it will be on the basement wall running into side the panel. Both of those locations, in theory could be subject to physical damage.

    • @ElectricalCodeCoach
      @ElectricalCodeCoach  10 หลายเดือนก่อน +1

      When you figure out what it means you tell me lol jk it's very subjective

  • @scovillesadventures7141
    @scovillesadventures7141 ปีที่แล้ว +2

    Why not in a theatre?

  • @1sgsmith1
    @1sgsmith1 8 หลายเดือนก่อน

    Does the PVC have to be secured within 12 inches of a box? I think I've heard that non metallic cables have this requirement.

  • @ronaldnaeyaert3653
    @ronaldnaeyaert3653 9 หลายเดือนก่อน

    For a generator inlet box, I ran schedule 40 PVC gray conduit from the lower left side of the main panel up the basement wall and out though the foundation into a PVC LB. then up the outside wall into the inlet box. #6 THWN cable is in the conduit. Total length about 12 with 8' in the house and 4' outside. There are a couple of sweep 90s in the hosue. Do I need to redo it with EMT?

  • @dan9372
    @dan9372 ปีที่แล้ว

    What does your logo say on your jacket? Is it Mc Carty?

  • @safetythirdified
    @safetythirdified ปีที่แล้ว +1

    Not sure where it is in the code, but PVC is not allowed in plenum space due to lack of fire and fume retardation. The fumes are toxic, in fact if burned/melted.