How to install Type 2 Surge Arrestors without Integral HRC Fuse

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ธ.ค. 2024

ความคิดเห็น • 55

  • @atifradwan8169
    @atifradwan8169 3 ปีที่แล้ว +2

    I have to thank you so very much for the fantastic presentation.
    It is so easy to understand. Well done and keep it up

  • @JasperJanssen
    @JasperJanssen 2 ปีที่แล้ว +7

    By simply wiring the input/output of the fuses “in reverse”, you’d be able to save something like twice 20 cm in length, without reducing safety device function. Which for a total max of 60 seems huge. Would that not be allowed in whichever country this is? (You could also mount them upside down, given that din rail is symmetric, if you think input and output clamps are somehow holy.)
    The way it is here I’m not convinced the total length is in fact less than 60 cm.

    • @mfr58
      @mfr58 ปีที่แล้ว +1

      In UK 50cm is recommended max. The shorter the better....

  • @cyrilnhlanhlashabangu6546
    @cyrilnhlanhlashabangu6546 4 ปีที่แล้ว +2

    It is easy to understand the way you presented it...

  • @pradyb646
    @pradyb646 4 ปีที่แล้ว +2

    Could you provide the link from where you got the Electrical Crimps? Thanks

  • @nipunshyamal1173
    @nipunshyamal1173 4 ปีที่แล้ว +3

    Thank You very much and 100% clear

  • @musabkanani2873
    @musabkanani2873 4 ปีที่แล้ว +1

    Fuse in heigh voltage or heigh current will be cut the continuity the current
    So what the benefit it

  • @syedhaider7121
    @syedhaider7121 7 ปีที่แล้ว +1

    Thank you for excellent presentation. It was very helpful.

  • @meseretgirma6489
    @meseretgirma6489 2 ปีที่แล้ว

    God bless you I sow agood presentation

  • @startekgregory4257
    @startekgregory4257 5 ปีที่แล้ว +1

    What kind of electrical code is that, with Blue = Phase and Black for permanent neutral?

    • @TheChipmunk2008
      @TheChipmunk2008 5 ปีที่แล้ว +2

      Indian likely... the old UK phase colours were red/yellow/blue, or originally red/white/blue with a black N
      The UK's since harmonized to brown/blk/grey phases and blue N, but many countries still use our old colours.
      Personally I always still think of black as N... which could be dangerous these days :(

    • @marlondaniels3114
      @marlondaniels3114 4 ปีที่แล้ว +3

      Not silly american

  • @ferdinandmeriales2722
    @ferdinandmeriales2722 5 ปีที่แล้ว +2

    I thought the cable is also connect to earth rod.

  • @flow5718
    @flow5718 5 ปีที่แล้ว

    Thanks for the video, I have a few suggestions. Use an appropriate current-rated MCB instead of fuse (I believe you're using the maximum manufacturer allowed fuse rating here at 125 A). Also in your comment to Frederico Cunanan
    you mention how an SPD might create a fault as it ages. I think while it may have been prudent advice in the past, type 2 SPDs based on MOVs nowadays have an end of life indicator _and_ an internal disconnector to prevent diverting surge through a failed module/MOV. And if for some reason, the internal disconnector did fail and the SPD creates a fault in the circuit, simply remove the failed or faulty SPD module. Most SPDs today are modular like the Dehn SPD you use here. Dehn is a solid choice btw, +1 for that, bit expensive in India but we have really good standards compliant alternatives like Havells at a third of the price.

  • @franzkronhofer782
    @franzkronhofer782 2 ปีที่แล้ว

    Why rotate you the Surge-Arrestor about 90 Degrees? Then you have shorter wires to them.

  • @talalalrahbi9430
    @talalalrahbi9430 5 ปีที่แล้ว +1

    thank you for this video, i want help ,I want to connect advices called LDI (LARGE DECODER INTERFACE) which input voltage 240VAC+-10%,50HZ and the output 24VAC@3.15A,50 HZ.how do I connect voltage surge protector to this advice?

  • @manojbaruah9149
    @manojbaruah9149 3 ปีที่แล้ว

    Why the fuse there is a MCCB pls explain

  • @marlondaniels3114
    @marlondaniels3114 4 ปีที่แล้ว

    Why are you recording upside down?

  • @Niravpatel001
    @Niravpatel001 7 ปีที่แล้ว +1

    how to calculate Fuse size [ampere] for surge protector?

    • @sankalanchakraborty2176
      @sankalanchakraborty2176 6 ปีที่แล้ว

      simple formula if your device watt is 1000 and you power supply voltage is 220 V your ampere is watt/volt that means 1000/220 =4.5(ampere).. so you can add fuse 10 ampere

    • @flow5718
      @flow5718 5 ปีที่แล้ว

      What
      Sankalan Chakraborty said, but also check the manufacturer recommendation (from their datasheet) for maximum fuse (MCB) rating.

    • @indranilbal
      @indranilbal 5 ปีที่แล้ว +1

      @@sankalanchakraborty2176 the HRC fuse is not carrying the load current but rather the surge current to ground through the SPD.

  • @ffc100977
    @ffc100977 8 ปีที่แล้ว +2

    Can it be installed without fuse? Am I correct in saying that, since you are installing fuses means you are protecting the Surge arrestors from getting damage due to over current? Once fuses broke will this not back fire to the Circuit breakers?

    • @IPDgroup
      @IPDgroup  8 ปีที่แล้ว +4

      Hi Frederico
      Thank you very much for your contact and interest. The purpose of the backup fuse is to remove the surge arrestor from the circuit when it reaches the end of life. All MOV based surge arrestors begin their life as a high impedance connection to earth except during high voltage spikes at which point they switch to a low impedance connection to earth. As the surge arrestor performs its job over time it becomes more stressed and becomes a low impedance connection to earth. This is a permanent change, therefore to stop the surge arrestor from creating a fault condition the fuses will eliminate it from the circuit.

    • @AfaqSaleemChannel
      @AfaqSaleemChannel 7 ปีที่แล้ว

      I thought the purpose of the fuses was to isolate surge protector in case there is a surge and surge protector grounds the mains but for some reason the breaker does not trip which could lead to burning of wiring. I recently started to look into installing one for home therefore looking at its working etc. Can you please guide me which type of surge protector to use in case the phases short with neutral (happened last week with a friend during rain which blew a lot of electronics). Also I thought they would last life time until they face surges, isn't that the case? How long will it last in years ?

    • @openmind2161
      @openmind2161 7 ปีที่แล้ว

      Considering breaker is more pricey than Fuse ,so maybe Fuse should be on the front line considering it cost nothing to put new wire inside fuse

    • @walkbaby
      @walkbaby 7 ปีที่แล้ว

      Frederico Cunanan
      H

    • @lakshmandalpadado9066
      @lakshmandalpadado9066 5 ปีที่แล้ว +1

      NO fuses!!. These are MCBs. No one uses fuses anymore.

  • @mybb9200
    @mybb9200 7 ปีที่แล้ว

    125A HRC Fuse for backup prorction only for surge arrestors?
    I understand if 125A fuse installed on main feed for protecting the entire panel, but installing 125A fuse backup only for surge arrestors isn't it way way to big for the purpose?
    I mean isn't enogh using 6A HRC fuse for backup prorction of surge arrestors?

    • @romandemidov2659
      @romandemidov2659 5 ปีที่แล้ว +1

      6A not enogh! U must use 125A. this fuse use for backup LINE - not for backup prorction of surge arrestors!

    • @startekgregory4257
      @startekgregory4257 5 ปีที่แล้ว +2

      You do not have to use any fuse (s2=not to use) when main installation breaker is lower or equal 125A.
      it is intended to protect installation, than should be installed with good direct ground connection.
      All of those main breakers will melt and fuse together during lightening strike
      (most of them are no more than 10kA).
      Sure protector is your only hope, not to have most of equipment burned in your home.

  • @ajayvaidya6538
    @ajayvaidya6538 4 ปีที่แล้ว +1

    Explained well thanks.

  • @arulmurugan9554
    @arulmurugan9554 4 ปีที่แล้ว +1

    Thank you good presentation

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs ปีที่แล้ว

    Great video tutorial ❤ thanks for sharing your knowledge and experience 🫡🇵🇭♥️

  • @jasonkuy7100
    @jasonkuy7100 7 ปีที่แล้ว

    What is a surge arrestor

  • @larryramirez2172
    @larryramirez2172 4 ปีที่แล้ว

    Hello , can you please send me the schematics on how to connect this Siemens - TPS3A1220VX02-1 Phase Surge Protection Device, 120/240VAC. please I am lost

  • @rajeshsatavan
    @rajeshsatavan 6 ปีที่แล้ว +1

    Need those tools.

  • @Blondyn_SK
    @Blondyn_SK ปีที่แล้ว +1

    This is whole wrong. Wires are very long. Correct is bottom swich to bottom fuse holder and top fuse holder to top SPD.

  • @dhadumia
    @dhadumia 5 ปีที่แล้ว

    Awesome video.

  • @othonielgarcia2393
    @othonielgarcia2393 4 ปีที่แล้ว

    Great video

  • @hiteshsingh6534
    @hiteshsingh6534 6 ปีที่แล้ว

    Typ of surge protecter dital plz

  • @SachinPatil-yg8ep
    @SachinPatil-yg8ep 2 ปีที่แล้ว

    S2 kya hai

  • @pradippathak41
    @pradippathak41 5 ปีที่แล้ว

    Good demo

  • @belkhir2055
    @belkhir2055 5 ปีที่แล้ว

    شكرا

  • @henrynwosu9870
    @henrynwosu9870 2 ปีที่แล้ว

    Yea

  • @Rajan-ur8ip
    @Rajan-ur8ip 5 ปีที่แล้ว +1

    Nonsense where the supply main and load will be connected?

  • @PANKAJSHARMA-zi5bd
    @PANKAJSHARMA-zi5bd 5 ปีที่แล้ว

    Aap Ka number dejiye sir

  • @hsnch1113
    @hsnch1113 3 ปีที่แล้ว

    Rong