Thanks for watching 😉 you can get it from shopee /lazada search under (voltage detector pen) Or electrical hardware shop will have as well. Hope you can get one for your DIY projects😁 its very convenient
Hi, do you have video on autogate controller board installation? I have a DNor autogate controller, but lately it seems like it's not working anymore. So can I know if I can just replace it with any type of autogate controller board? By the way, my autogate is folding gate type. Thanks.
Hi, if there is a chances i will films this content. Well all model is almost the same, the incoming sources 220v-240v + - pole is to connect at the bottom right . which the board will have written there. I will explain the sequence from bottom right to left. So after the incoming 220-240, it is the output to the transformer which is shape like a block. . So this transformer had 2 outputs, which means + and - poles each..9v and 12v.. The 9v we can ignore just use wire tape to tape it . we use the 12v + n - wire, connect to the board controller. Then there is the auto gate arm wire you have 2arms so + n -poles total is 4wire.connect to the arm connection. Then finally the last 1 which is the bottom left that is the switch from your living room to press 1 or 2, green or red for the door controller. I hope you get the ideas 😂 but i will find a chances to film this.
加油,专业。马来西亚缺少专业的UP主。
谢谢你的支持!! 😆
谢谢你的分享呢。真的很有兴趣。很期待你下个影片。加油
雖然電箱還是會交給專業人士做, 但看看也是很有趣
Very good video. Please tell The beeping test kits where to buy?
Thanks.
Thanks for watching 😉 you can get it from shopee /lazada search under (voltage detector pen)
Or electrical hardware shop will have as well. Hope you can get one for your DIY projects😁 its very convenient
@@Handyman2Uchannel thank you
谢 Maxiu,这集超实用!🤩
謝謝專業的教程
谢谢观看。。 。😆
请问mcb 20A breaker 可以安装几个13A 插座, 2.0hp 以上的就从总电箱拉过那要放多少A呢?
一般新屋子standard 一粒20a 两个 13a 插座。 可是你弄4个也是可以。 主要就是输出的电源 ,如果你拉的这码线总用量不超过4800watt 就没问题。
20a X 240v =4800watt.
所以2马力的冷气如果用16或20a 也是可以。 因为2 .5的 使用量也是 大约 2700watt 左右。
@@Handyman2Uchannel 谢谢你
很棒的教学,谢谢您的视频👍🏻
如果角头的屋子客厅extend出去,要从电线杆拉”大电”进家用电表,请问如何先断电?然后才连接到家用电表
你好,如果电表之前的工程需要TNB 的人才可以弄。
电表之后呢我们就能弄。拔掉63a 的cut out fuse 就可以移/弄DB
@@Handyman2Uchannel 是不是可以直接用手把三个cut off fuse拔掉就能完全断电?会危险吗?
是的那个壳是朔料的不导电。 手拔掉就可以了。
谢谢,期待你更多的精彩影片😊
可以请问如何在DB拉新的灯线和开关
你好我有拍过类似的影片。 可以看看我电工list 里的影片
您好 电工告知 要增加插座 首先需要加大 MCB 所以直接把 MCB 从 20A 换去了 32A 可是电线没重新拉过 可是电工也没检查 原本的电线是否支援 32A 请问这样符合安全? 是否存在安全隐忧 ?
一般插座都是最好用32A的。20A我们通常只用heater 1马力 之类的。32A插座只要你没有同时用在开冷气,开热水器,开oven ,开电子炉是没有问题的。普通冰柜,电视,风扇类,32A绝对足够用。1A=240w 你可以自己算算你自己用的电器w数
非常正确🙋👍
如果我的mcb c20 给water heater 一推上去,全屋子跳电是mcb坏了吗?
我已经把waterheater 的电源拆了还是一样
有一条黑和青色touch 到了。 跳的是 elcb 对吗? 先把全部MCB 推下来。 然后把main MCB 63a 推上去,接着就 elcb, 然后一个个 MCB 推上去。 推到看是哪一个导致跳电推不上就skip 掉, 把有问题的MCB 排除。
@@Handyman2Uchannel是我已经知道是那个waterheater的mcb问题,早上跳电,我把全部退下来,慢慢推上去,一推到那个waterheater的mcb就跳,现在那个mcb我就不推上去,就没问题了。我以为heater坏,就把heater的电拆掉,然后再推那个mcb,但是还会跳电哦
@khortongsengelvis3152 heater switch 呢试下拆出来看看有电线touch 到吗。
因为 MCB 少有这个问题
老板,请问家里热水器要装几号的MCB?因为旧的热水MCB一直跳电,搬回去又可以用,不久过后又掉下来跳电,谢谢
20a 。
目前,你的MCB 是那款? 如果开回可以用,但是不久又跳。那你更换新的MCB吧。
这个用了大概多久?
hi....想问问。。。mch fuse会坏的吗?比如说,不通电的问题。。。。用试灯去试可以的吗?
会啊,会坏的啊。 可以用test pen 试电。
😮谢谢你!😮
Hi, do you have video on autogate controller board installation? I have a DNor autogate controller, but lately it seems like it's not working anymore. So can I know if I can just replace it with any type of autogate controller board? By the way, my autogate is folding gate type. Thanks.
Hi, if there is a chances i will films this content. Well all model is almost the same, the incoming sources 220v-240v + - pole is to connect at the bottom right . which the board will have written there.
I will explain the sequence from bottom right to left. So after the incoming 220-240, it is the output to the transformer which is shape like a block. .
So this transformer had 2 outputs, which means + and - poles each..9v and 12v.. The 9v we can ignore just use wire tape to tape it . we use the 12v + n - wire, connect to the board controller.
Then there is the auto gate arm wire you have 2arms so + n -poles total is 4wire.connect to the arm connection.
Then finally the last 1 which is the bottom left that is the switch from your living room to press 1 or 2, green or red for the door controller.
I hope you get the ideas 😂 but i will find a chances to film this.
@@Handyman2Uchannel Thanks for very clear explaination! I hope to see a video of it when you get a chance. Thanks!
可以问一下,我开关电风扇有时跳闸,有时又不会怎么回事。谢谢
你家里那把风扇是楼上的吗?可能电线给老鼠咬,我有遇过这情况。
其实有很多因素导致跳电
另一个可能就是风扇的电线过热融了皮,有少许的走电情况。
不然就是那个MCB太敏感了,把它换掉
想请教关于RCCB, 是不是只需要安装在main DB? 因为我家有一个Main DB, 三个sub dB. 目前只有Main DB 安装RCCB 而已,想问说我需要安装RCCB 在其他的sub DB 吗? 一个Sub dB 上面有一个ELCB, (应该是坏了,因为按了那个T button 没反应,我需要更换吗?)
最好每个sub DB 都弄一个 因为sub db 的作用就是来分区域。 一般上 楼上 一个, 楼下一个, 或者房间 1粒,厨房一粒那样。
如果的插座有问题shot ,就不会整间家都没电。
Rccb 还有一个作用就是 可以分轻负担。 普通一粒rccb 63a 可以分给 18-24个 mcb.
如果只有一粒rccb来出给很多的mcb 那么他的负担会很大,很容易overload跳电, 甚至fuse 跳电的功效会失灵。 就好像你的T button 没反映。 安全起见换掉它吧。 还有那些sub db 放 rccb 给它。
你sub db 的电线是用着16mm 对吗?
@@Handyman2Uchannel 我不会看sub dB 的电线是多少mm. 我的Main dB 用着RCCB 40A (正常操作,按T 有反应),另一个sub DB 是ELCB 63A (按T没反应),那么我要买一个更换的话需要买回ELCB 吗? rccb 和ELCB 有什么差别? 通常都是用哪一种多? 哪一个牌子比较耐用?
可以直接加大的吗?我之前想把 6A 换到 20A 的,电技工说直接换怕原本的电线 support 不到会溶掉就不敢换了。也看不到原本的电线是怎样的?
6A 是给灯用的。要换可以换10a.
如果是插座一般都是用16a或20a.
对,也是要看电线。
电灯用1.5..
电气用2.5
如果6a 换了20a,但是电线是用着1.5 就会溶掉。 因为还没来得及跳闸电线就融化了
所以fuse 也是要看是什么电线
请问一下第一个mcb c40够用吗?我看到很多家都是装c63的
如果是旧式单层排屋,小间的政府组屋,电器不多c40够用的。 但是可以换c63,就比较好。
最好不要加太大,overload elcb 不能trip
想请问一下冷气通常是总电箱拉多一条电线,还是可以使用插头分多一条电线出来。
都有, 如果可以的话当然从总电箱拉过。 1hp,1.5hp 可以插座拿电。 很多冷气佬都这样做。 但是 2.0hp. 以上的就从总电箱拉过吧
@@Handyman2Uchannel插座拿电会危险吗?插座的mcb要多大的? 谢谢
👍
我试过把总电关了,为什么还有电的?那次差点sot死我,幸好楼梯是rubber底,2个手触电就重重的跌下来,这经历让我非常害怕这东西了
你关了总电闸后要拿testpen 检查。 如果关了还有电就是那个总电闸坏了
迟点我会cover 一集弄电必备工具和步骤。 记得留守😲
理论上来说 如果我要全部fuse换取20a的fuse可以的吗?为什么没有人这么做呢
电插座一般都是16a 或20a.
灯,风扇6a 或 10a.
fuse有分电源供应的极限,但是要和电线的大小来配合回。 一般灯,风扇都用1.5mm 电线,所以这电线的承受度是10a fuse,
如果把电灯的fuse改到20a的话就会很危险,因为电线承受不到这个能量,会发热融化。 电线烧毁了但mcb fuse 没跳电。
所以假设现在原有的mcb fuse 是16a 电线在这个fuse 用着2.5mm 就可以换去20a. limit 可以多1000watt.
至于20a fuse 换去32a 的话就需要看电线了,一般如果是4mm 就可以这样做。
我这个视频里的刚好有个空fuse,但是不适合用,拉的电线是2.5mm 的,打算给插座用,所以如果我直接插入连接的话,我的maximum load 是 240X10a , 所以如果电器使用的电源超过2400watt ,fuse就跳电。
所以这个fuse 是需要与电线配合,不可以随意放。 当然会跳电是好事,安全。 不会跳的话烧起来才知道,就很危险了。
希望我的解说能够让你明白fuse 的疑问
看到你的影片不讚都不行。
谢谢支持😆
@@Handyman2Uchannel 將來如果有機會回到馬來西亞。我想和你喝咖啡。
你现在在新国吗?
@@Handyman2Uchannel 對!好想念我的媽媽。
一馬力冷氣應該用什麼號?
20a
请问旧的MCB 是16A, 如果换成20A,可以吗?有什么好处和坏处?
其实16或20a的mcb 相差不大。
至于好处和坏处你可以换句话这样说,
16的limit 大约3800-4000watt 就跳电。
20的limit 大约4800-5000 watt 就跳电。
如果现在你是用着16, 电线是2.5mm 可以换去20a。
多1000watt可以用,就好像银行开大那个 credit limit 那样。
要换32就最好用4mm电线。 如果电线太幼(example..1.5mm),还没跳电但电线会融化烧掉。
@@Handyman2Uchannel 想要在现有的插座旁加多一个插座,如果原有的插座是4mm,那么新加的插座可以用2.5mm吗?(因为也不懂原有的插座是4mm还是2.5mm)
@@casiotiger7872 可以用2.5电线
@@Handyman2Uchannel 好的,谢谢你
请问怎样check inspection 的电箱
这个要有基本电的知识才碰吧, 我之后会分几集来讲解。 不然40分钟也讲不玩😪
记得留守频道的影片吧😉
请问你是工程师吗?
不是, 我只是一届水电工, 我本身下手做的,是一位独行侠。 一个人顶三个那种😂
elcb 63a 0.1a 和0.01a 有什么分别
0.1a=100mA
0.001a=10mA
你好 0.1a 和 0.01a 就如这位网友说的那样。 他们的分别就是敏感度。个有个的用处。
10mA 的通常用在热水器如果电压不稳定,有走电,点点就会跳电。 来预防我们触电。
100mA 的通常我们会把它装在main fuse 过后,mcb 之前。
如果这个10mA 的装在mcb 之前就不合适,下雨稍微打下雷就跳闸。
mcb 不是上面进电下面出电吗?
其实没规定。 都可以,但要有规律, 一排过上面进就上面。 不要有些上有些下。 不然检查电源时会很困扰🥹
@@Handyman2Uchannel 我比较喜欢上面进电下面出电,不过马来西亚几乎是下进上出
真的是MCB
😂
请问2.0hp 冷气 以上要安装多少a呢?谢谢你
20 a 就够了。
666
🙇🏻💓💓🤩