Master Metal Stud Framing & Drywall All Types Of Corners Lesson

แชร์
ฝัง

ความคิดเห็น • 260

  • @ConstructionKronies
    @ConstructionKronies  4 ปีที่แล้ว +5

    Keep Learning Metal Stud Framing HERE: bit.ly/ExpertFramingLessons

    • @johnlee4014
      @johnlee4014 3 ปีที่แล้ว +1

      Hey man hope your doing well. I usually put the relief cut on the longer piece of track so that the piece attached to the frame goes into the wall and gets locked in making it stronger. It does screw up the flow of the installation of.board depending on which way you start your drywall. What's your opinion on that. Awesome channel👍

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      @@johnlee4014 yes, I know it's easier that way but I also screw my door clips in without the tabs. This way is the proper way to do it. Cheers man, I know your comment is over a year old just saw it! Thanks for watching 👍

    • @ndaworld07
      @ndaworld07 ปีที่แล้ว

      Quick question, how do you run electrical around corners with this method of locking in the drywall? Do you leave a little slack in the electrical so that you can push in the drywall, or do you just cut the drywall so that it stops before the wire?

  • @jonw6376
    @jonw6376 2 วันที่ผ่านมา +1

    Whewee! I'll definitely have to watch this 7-13 more times to learn inside vs. outside corners. You're saying "outside" when we're looking at the inside. I'll figure it out if I decide to do metal framing. Thanx so much!

    • @ConstructionKronies
      @ConstructionKronies  2 วันที่ผ่านมา

      Yes, my apologies, I am really trying hard to improve how I deliver information and your comments are super helpful. The past 7 years I have made a lot of changes. If you do ever need help you can always send me an email and we can do a call!

    • @jonw6376
      @jonw6376 2 วันที่ผ่านมา

      ​@@ConstructionKronies You caught a couple times when you misspoke, but that wasn't a problem. It's all great info, & it's fast (so some can easily be missed), BUT that's what is for. No worries! I just found your videos & channel today, but you're doing great, IMO! I REALLY hope I can build sooner than later, but we'll see. Thanx SO much for your reply, & your offer for more support.

  • @TR-rn3pd
    @TR-rn3pd 3 ปีที่แล้ว +19

    Production wood framer and form setter for 20 years. Never touched a steel stud in my life. Starting a new commercial job on Monday. All steel , no wood anywhere. Binge watching your videos so I don’t get caught in a lie “YEAH STEEL, NO PROBLEM” wish me luck.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +2

      Haha that's awesome man, I have the exact same story. Was a wood framer before I started in steel. Here is the link to my framing playlist th-cam.com/play/PLRtmYu3z-FENOxNCqdjW0ey47mSNc5Klm.html If you have any questions be sure to ask and keep me posted! You got this no prob!

    • @wastedShaman
      @wastedShaman ปีที่แล้ว +2

      The only problem is you will fall in love with steel. Strait stud every time. No sorting out the hockey sticks at home depot. Boxing in duct work with steel is so much better as well, lol.

    • @RedHeatedStepChild
      @RedHeatedStepChild 7 หลายเดือนก่อน +1

      How did it go? Hope it went well.😂 Furniture guy here for 20 years, no joke. Starting a “yeah steel np” job next week. Wish me luck. And yes i am binging here.

    • @innando
      @innando 4 หลายเดือนก่อน

      @@RedHeatedStepChildhow was that?

  • @outman6207
    @outman6207 ปีที่แล้ว +2

    hi I have question, why did you leave 5/8 space between door stud and floater? Thank you muchly

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      Sure yes, just so we have room to move the stud and get the drywall in.

  • @ddhgerlb
    @ddhgerlb 2 ปีที่แล้ว +7

    Thanks for the super informative video. As a carpenter using wood, metal is a different world but you explain it clearly. Also really appreciate someone who shows pride and quality in their work as i do with mine. 👍👍

  • @coreBsp8002
    @coreBsp8002 22 วันที่ผ่านมา +1

    Thx for the lessons. It helps , i am starting at my old job with framing and drywall. This has helped me remember

    • @ConstructionKronies
      @ConstructionKronies  22 วันที่ผ่านมา

      Right on!! Always leave me a comment if you have any questions!

  • @BichNguyen-bd6ht
    @BichNguyen-bd6ht 11 หลายเดือนก่อน +1

    Thanks for the video, it's supper helpful. How do you install 2 layers of 5/8 Fire Codecore drywall to Conder Blocks? Can I just glue it or use Wood first? Or any other best practice I should follow?

    • @ConstructionKronies
      @ConstructionKronies  11 หลายเดือนก่อน +1

      We have done it a few different ways. 1. is to glue and pinbolt the first layer to the block then glue the second layer to the first - very expensive
      2. we frame a furring wall in front with 1-5/8" 25 gauge stud or 3-5/8" so electrical can go in or 6" for plumbing and electrical (this is the best way) 3. we shoot and drill 7/8" furring bar to the block then drywall. (a pain to do)

    • @BichNguyen-bd6ht
      @BichNguyen-bd6ht 11 หลายเดือนก่อน +1

      @@ConstructionKronies Thank you again! I think I will go with the second option you have mentioned. Keep making all the great videos, super helpful.

  • @AMindInOverdrive
    @AMindInOverdrive 2 ปีที่แล้ว +6

    I really appreciate these videos. I'm a steel stud and drywall estimator for the past 10years and my only site work was working with an ignoramus; He was supposed to show me how to frame but all he did was wreak of stale alcohol and grunt at me. It's nice to have someone explain what's being done and why ;-)

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Nice!! I love you guys who watch to learn what's going on in the field. Wish more of you guys did. I have some architect and engineer viewers too who come to see what we do.

  • @Handstandpussup
    @Handstandpussup ปีที่แล้ว +1

    Thank you for teaching me how to do corners. I really appreciate the door corner.

  • @bayanez9859
    @bayanez9859 3 หลายเดือนก่อน +1

    These videos are amazing please make another

    • @bayanez9859
      @bayanez9859 3 หลายเดือนก่อน +1

      Nvm Im idiot there’s a playlist 😂

  • @GarwoodNick
    @GarwoodNick 4 ปีที่แล้ว +8

    You're doing the Lord's work with these videos. There are very few videos on steel framing and the need for instruction will only grow with the ridiculous price of lumber.

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว +1

      Thanks man!! I appreciate that. This is why I do it, not a lot of help out there for commercial construction. I am glad to help!!

    • @emanuelquinones2534
      @emanuelquinones2534 2 ปีที่แล้ว +1

      @@ConstructionKronies I'm retired from construction work after 42 years and you be making a school soon. Like your videos and yes. We don't have many framers in metal studs drywallers are a rare breed too. Residential and commercial work differs a lot

  • @Leebob27672
    @Leebob27672 3 ปีที่แล้ว +2

    Thanyou.You are an inspiration,Bro

  • @maldoso76
    @maldoso76 2 ปีที่แล้ว +3

    I appreciate this videos so much. I’m a first year apprentice framer and rocker, and I’m more rocker than framer at the moment but these videos help so much to become for of a framer.

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      Excellent stuff, being a rocker first is the best way. I learned framing first so when I started drywall and got good at it I learned how to really frame. It's all about the drywall and finish. Taping teaches you how to be a better boarder as well. If you ever have questions you know how to find me👍

  • @leolizardo
    @leolizardo ปีที่แล้ว +1

    SO BEAUTIFUL EXPLANATIONS. THANK YOU.

  • @apt3503
    @apt3503 2 ปีที่แล้ว +2

    Thanks for the very detailed description of the work process. I've learned a lot watching this.

  • @Wanderer777jk
    @Wanderer777jk 3 ปีที่แล้ว +1

    This is such a gem....After seeing this, official Knauf instruction on cornering looks like a child's play. I red it all and never did they mention anything like this, this is a real deal.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Thanks man! Super appreciate that! Learning in the field is totally different from the books!

    • @Wanderer777jk
      @Wanderer777jk 3 ปีที่แล้ว +1

      @@ConstructionKronies Damn right it is :D They should copy this and make it official, this structure is superior in every way possible! Thx for sharing. Btw could You make some "T" shape joint construction video if You already haven't, at least I havent seen it jet even if its out there, I havent checked all the videos so far

  • @seantaylornation21RIP4evr
    @seantaylornation21RIP4evr 4 หลายเดือนก่อน +1

    Appreciate the videos and time man! Brand new to the construction industry overall got a job as a project manager for a drywall contractor doing metal stud framing in Florida just last week straight outta college. Trying to learn as much as I can and currently binge watching this series. Any tips please let me know everything is brand new so wish me luck!

    • @ConstructionKronies
      @ConstructionKronies  4 หลายเดือนก่อน

      You're in the right place! Absorb as much as possible and relate it to what you see in the field. If you ever have questions leave me a comment! We can always do other things like email and zoom calls if your stuck on something!

  • @sameersameer-rx1eg
    @sameersameer-rx1eg 3 ปีที่แล้ว +1

    Bro you are the king! God bless you for sharing your knowledge!

  • @Hockeykid1515
    @Hockeykid1515 2 ปีที่แล้ว +1

    Best video. U have ever done u should do all videos like this I’m taking a metal stud test tommorow and I hope I pass been watching your videos

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Thanks man, I really do appreciate the feedback. I have great success with this format, I will start doing it more!

  • @GrahamKilby-pe8qu
    @GrahamKilby-pe8qu 9 หลายเดือนก่อน +1

    What gauge should be used for external load bearing walls millimetres

    • @ConstructionKronies
      @ConstructionKronies  9 หลายเดือนก่อน +1

      We use 16 to 18 gauge wind load studs, 6" or 8"

  • @alfaresamine5331
    @alfaresamine5331 2 ปีที่แล้ว +1

    Thank you man, شكرا يا رجل
    ✌️

  • @dillathekilla3110
    @dillathekilla3110 11 หลายเดือนก่อน +2

    Do you need dpc for bottom of your tracks since metal is in contact with concrete??

    • @ConstructionKronies
      @ConstructionKronies  10 หลายเดือนก่อน

      Yes I like to use chemtron on everything interior and foam gasket on exterior.

  • @lealoctavio18
    @lealoctavio18 4 ปีที่แล้ว +4

    This are the kind of videos that will get you 100k subscribers Chris, keep it up very well explain too

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Dude!! Thanks man!! I'm so sorry I missed this when you posted!!

  • @frankgenner782
    @frankgenner782 3 ปีที่แล้ว +1

    Would be nice to see a video of you framing an outdoor kitchen using steel studs

  • @smokintee117
    @smokintee117 ปีที่แล้ว +2

    I am 65 years old and this is how I make a living most of the time. My dad was the forman and I was his assistant. He taught me to do things by myself that were hard for two men to do. I dream of him and work all the time.

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว +1

      I was taught by old school journeymen myself. Your right about them teaching us how to do it on our own. It's amazing actually. Respect to you bro! My dad is more of the business type, 75 years old and still working though, he will never retire says what am I going to do? Watch TV? Haha. Awwh man thanks for sharing bro!

  • @mikedsjr
    @mikedsjr 3 ปีที่แล้ว +1

    Thanks for this lesson. In my 20+ years I I haven’t gone out to many jobs sites for my commercial projects so this helps greatly.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +2

      that's great! If you ever want me to go over anything just ask!

  • @georgeomalley6066
    @georgeomalley6066 3 ปีที่แล้ว +1

    Brilliant detailed video, Thank You 👍

    • @georgeomalley6066
      @georgeomalley6066 3 ปีที่แล้ว +1

      Can you explain the Staggered joint's, is it for 🔥 ?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      Yes stagger joints are for proper fire rating and strength. Why we also stagger where the bevels land from side to side of a wall with single layer both sides. Cheers man!!

  • @roberthornsby9328
    @roberthornsby9328 3 ปีที่แล้ว +1

    Great video and tips keep up the great work

  • @ElrikvanMeerveld
    @ElrikvanMeerveld 3 ปีที่แล้ว +1

    This is great info, thanks for the effort!

  • @hh4545
    @hh4545 ปีที่แล้ว +1

    Hi, what type of caulking did you used?

  • @jamestobon3941
    @jamestobon3941 ปีที่แล้ว +1

    Excellent!

  • @jonathangarrett312
    @jonathangarrett312 ปีที่แล้ว +1

    When you have walls taller than 10 ft do you have to add purlins to prevent twisting?

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว +1

      Negative, no. Two things, 1 we always square the stud in the top and bottom track and 2 we use carrying channel every 4' (bar that goes through the stud knockouts).

  • @LouisLinggandtheBombs
    @LouisLinggandtheBombs 2 ปีที่แล้ว

    Fantastic video. I’ll be doing this today!

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      How'd it go?

    • @LouisLinggandtheBombs
      @LouisLinggandtheBombs 2 ปีที่แล้ว

      @@ConstructionKronies I didn’t do it the end, we have to work out how wide the doors are. They’re heavy studio doors so maybe I should add 3/4 inch extra so I can add an extra wood frame?

  • @stephanebelanger2448
    @stephanebelanger2448 8 หลายเดือนก่อน +1

    Hi There. Love the videos. I am building my first steel structure this summer and wondering how much time I should allow for a team of 4 guys to closed off ext. walls from corrugated metal siding to drywall (2 X 5 /8 type X), wool insulation. I figured 2 hours per section of 10 linear feet. Walls are 12' high. Does that make sense?

    • @ConstructionKronies
      @ConstructionKronies  8 หลายเดือนก่อน

      If your taping the inside of the building and using membrane I would allow 38 hours per 10 linear foot ready for paint if your not taping or using membrane allow at least 19 hours per 10 linear ft.

    • @stephanebelanger2448
      @stephanebelanger2448 8 หลายเดือนก่อน +1

      @@ConstructionKronies thanks for the reply...do you mean 4 guys @ 19 hours each so total of 76 man hours for 10 linear foot section no taping. ?

    • @ConstructionKronies
      @ConstructionKronies  8 หลายเดือนก่อน

      No that is based on 4 guys, 19 hours for 4 guys. And your very welcome

  • @stephenfermoyle4578
    @stephenfermoyle4578 3 ปีที่แล้ว +1

    Great way of explaining things

  • @kneewall49
    @kneewall49 2 ปีที่แล้ว +1

    Mate, have you a suggestion on stud positioning and track cutting on a 45 deg corner? Not 90.

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      sure yes, that happens. You don't need to end the studs tight against each other just stop them so they can be squared close as possible to the end of your track, usually 1 to 3 inches apart. Let the drywall form the corner. Does that make sense?

    • @kneewall49
      @kneewall49 2 ปีที่แล้ว

      @@ConstructionKronies yes thank you.

  • @TalkingWithBob
    @TalkingWithBob 3 ปีที่แล้ว +1

    Your building videos are so interesting

  • @shanehecker4925
    @shanehecker4925 3 ปีที่แล้ว +1

    What type of cualking do you suggest for the floor tracks?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      We use the Chemtron acoustical caulking, it's black and messy.

  • @MerlinConstruction
    @MerlinConstruction 3 ปีที่แล้ว +2

    Got a commercial TI coming up with steel stud. Vids are awesome! Thanks for sharing.
    Could you go over other intersections, T intersections? Partitions (10’) intersecting full height (16’) corners and T intersections? Bracing?
    Thanks.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Yes for sure! I have a full metal stud framing playlist. The 2 videos I put out before this one go into more detail. I cover everything but the t intersection. For that I can easily draw you a diagram if you catch me live. All you need to know for that is to leave your track back so the drywall can pass through the wall and then you tie in the floater. You can also stop the drywall in the middle of the floater to bring out into the rooms.

    • @MerlinConstruction
      @MerlinConstruction 3 ปีที่แล้ว +1

      Thanks I’ll look for live, most interested in tieing top plates together with different wall heights, or do you brace and rely on drywall for fastening?
      You’re killin it, keep on making content!

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      @@MerlinConstruction Okay so what i do when tying in different wall heights is this; find where the new wall runs into the existing and put a brace across the 2 studs in that area. I actually laser the top of the brace to be the top of the wall I need. You can either add a 4 to 6" pc of stud to catch the track or cut a tab out of the track. I use a stud for the brace and lay it flat side out toward the new wall.

  • @johnhulbertyahoocomc
    @johnhulbertyahoocomc ปีที่แล้ว +1

    Great videos keep them coming. Question, double drywall , should i add to formula or not ?

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      Yes, you bet, for double 5/8 go 1-1/2" and if it's double half inch for some reason go 1-1/4" for the tab plus the steel width.

  • @djxxxplicit
    @djxxxplicit 3 ปีที่แล้ว +1

    Should you use caulk for the bottom side of the track or a thin sheet of foam? If caulk, what kind of caulk do you recommend?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      Yes we use the Chemtron acoustical caulking under the bottom track for interior partitions and foam gasket for exterior walls.

  • @alex46801
    @alex46801 ปีที่แล้ว

    11:52 opposite what you said, it's actually stronger because you have 7" drywall vs 3" and it's also easier to hang since you can slide it through the other wall if hollow metal doors is already attached.

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      Yeah, that's a common misconception many people think.

  • @adventurouspeach9043
    @adventurouspeach9043 2 ปีที่แล้ว

    Thanks bro..this was very informative and will teach me how to properly install my corners..Good looking out..

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Thanks for the comment, appreciate you!!

    • @admcalister
      @admcalister 2 ปีที่แล้ว

      The overlap is soo unnecessary, can place some adjacent and works the same, waster

  • @ddhgerlb
    @ddhgerlb 2 ปีที่แล้ว +1

    If i may make a video suggestion although admittedly i haven't looked at every video of yours.
    How about a short video speaking only about the various types of screws used and why, what, when.
    Great work you do, highly appreciated.

  • @robertbenton4687
    @robertbenton4687 10 หลายเดือนก่อน +1

    Many thanks for the vidio. Please could you explain how to make a corner where the angle is not 90° but 115°?

    • @ConstructionKronies
      @ConstructionKronies  10 หลายเดือนก่อน

      If you can imagine, overlap and run the top and bottom track ad tight as possible then put the studs in to ad close to the corner as you can get. The studs will be a few inches or more away from the actual corner, just float and 45 the drywall.

  • @kylemorgan7140
    @kylemorgan7140 9 หลายเดือนก่อน +1

    Are you always going on 16” centers? I’m new.

    • @ConstructionKronies
      @ConstructionKronies  9 หลายเดือนก่อน

      Yes most of the time. Its always 16" if not noted. Sometimes its 2' and even more rare it's 1'. The drawings and specs will tell you. In your case the foreman will tell you. If no one says anything always put them on 16"

  • @stevenhozjan7719
    @stevenhozjan7719 ปีที่แล้ว +1

    What type of caulking under the track?

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      Acoustical, brand name Mono or Chemtron. It's black.

    • @stevenhozjan7719
      @stevenhozjan7719 ปีที่แล้ว

      Cheers. We’ve been using blueskin wp200 and it’s expensive. Keep up the good work man 👍🏻

  • @yojuanjose1
    @yojuanjose1 2 ปีที่แล้ว +1

    Do you use different type of screws for metal studs?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Yes we use black phosphate screws for light gauge and zinc coated self drillers for heavy gauge.

  • @GoatZilla
    @GoatZilla ปีที่แล้ว +1

    instead of a floating stud can you do a California corner? Or does that not work with metal?

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว +1

      You can do hard corners yes, always just check on fire rating requirements. Sometimes the floaters are specified and sometimes the hard corner. In a non fire rated wall you can do it however you want.

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว +1

      You can do hard corners yes, always just check on fire rating requirements. Sometimes the floaters are specified and sometimes the hard corner. In a non fire rated wall you can do it however you want.

  • @jumpship88
    @jumpship88 3 หลายเดือนก่อน +1

    We do commercial steel framing in Canada. I started last year. Ive never seen anyone caulk the bottom track. Some of the guys I work with seem like real pros, everything the do comes out perfectly square and straight everywhere and the finished product is beautiful. Those guys also never use caulk. So Im wondering what is the poiny of using caulk?

    • @ConstructionKronies
      @ConstructionKronies  3 หลายเดือนก่อน

      It should almost always be used, for water, sound and thermal bridging. On any walls that are dividing or fire rated always use it, on exterior walls we use foam gasket. I'd use it in kitchen, bathroom, all basement walls for sure.

    • @jumpship88
      @jumpship88 3 หลายเดือนก่อน

      Thanks for the reply. I guess I work for a company that cuts a lotta corners then. We do fire rated walls all the time, but we have never used caulk.

  • @lenmcdonald1407
    @lenmcdonald1407 4 หลายเดือนก่อน +1

    How do you know which direction to put the studs?

    • @ConstructionKronies
      @ConstructionKronies  4 หลายเดือนก่อน

      We face them hard side the same way we draw our tape measure from. It's instruction to the drywaller on which way to start from as well. Think of them like an arrow pointing in the direction you want the drywall to go. Hard side is the flat side and soft side is the open side. We also always screw the soft side then hard side in the bevels so the studs don't twist. Hope that helps!

  • @ndaworld07
    @ndaworld07 2 ปีที่แล้ว +1

    I’m using metal studs in my basement and so I’ll be putting a base plate of PT lumber under the track. How do you do this if using PT under your track?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      You sure you want the wood under? I would just use a foam gasket or acoustical caulking like the chemtron. But if you want it, you will need to hammer drill in smack pins!

    • @ndaworld07
      @ndaworld07 2 ปีที่แล้ว

      Interesting! I’m not tied to using the lumber, although I do already have it. I’ve just always been told that you have to use PT under it when framing out a basement. But just using foam gasket makes sense. I think the only question I have is, do I just put the edge of the foam on my chalk line so that the edge of the foam and the metal track all sit flush with the chalk line, or does the foam need to overlap either side of the track? If it does need to overlap, how do I make sure I’m on my line?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      no overlap needed, the foam will just go on the bottom of the track centered. sorry I missed your reply TH-cam doesn't notify me properly when someone replies, I need to go in an check for them and I didn't have time till now.

  • @RaymondGettler723
    @RaymondGettler723 2 ปีที่แล้ว +1

    The floater stud is a wonderful method. But what is the concept of it,if you don't mind me asking?. Reason?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      It has a few purposes that I know of, 1 - Specific Fire Rating, 2- Easily pass drywall through to lock in walls tight and 3- It gives your corners more strength, especially when there is a door it really gives that small leg more meat and potatoes if you know what I mean at the same time it makes it easier to get that little sucka in!

    • @RaymondGettler723
      @RaymondGettler723 2 ปีที่แล้ว +1

      @@ConstructionKronies that's amazing brother thank you for your help

  • @joshuadibari2957
    @joshuadibari2957 3 ปีที่แล้ว

    Can you use tapcons if you don't have a nailer

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      I wouldn't recommend it in the concrete but hex head self drillers 1/4" or 3/8" will work for any steel. Use the smack pins (pinbolts) in the concrete, hammer drill first.

  • @wastedShaman
    @wastedShaman ปีที่แล้ว +1

    You guys don't have to use a sil gasket in Alberta?

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว +1

      Yes we use it on all Exterior walls and use the acoustic caulking like Mono or Chemtron for the interior partitions if it is specified. I like to use it always on fire rated walls for sure and always on Exterior walls.

  • @izzyc.4746
    @izzyc.4746 2 ปีที่แล้ว

    Love the video

  • @randygeyer3336
    @randygeyer3336 3 ปีที่แล้ว +1

    Nice!

  • @bryanniahunter1147
    @bryanniahunter1147 3 ปีที่แล้ว +1

    Amazing video!! Do you not need to put pressure treated base plates down on the floor?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      Nope, not with steel. But you do need a foam gasket for exterior walls and chemtron black acoustical caulking for interior walls.

  • @anteroom5089
    @anteroom5089 3 ปีที่แล้ว +1

    On corners, How do you pick which track gets the cut for the floater and which runs the whole way thru?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      I am trying to word this right for you. So, the direction you pull your centers from is the flow of drywall so I put the floater stud in the first wall that gets drywall. Just think about the order you want the drywall to go on. Imagine a hallway with rooms, you want to drywall the inside of the wall with all the doors first and then tie in the floaters from the dividing walls. I hope that helps! I will try to remember and do a follow up video for you!

    • @anteroom5089
      @anteroom5089 3 ปีที่แล้ว

      @@ConstructionKronies nice thank you! The first part made sense, got lost on the last part lol

  • @OakMerchantSolutions
    @OakMerchantSolutions 4 ปีที่แล้ว +2

    Awesome explanation. Best so far. Keep going!!! Question - I’m going to put one of my tracks in a steel beam. Don’t want to shoot it. Recommendations on screws and drill bits (size of each and type please).

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว +2

      Use the self drilling 1/4" or 3/8" super (hex) screws!! I'll link you a product in the morning when I. Back on my computer!!

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว +1

      Okay my man we call these the super screw and are the best ones you can get bit.ly/SuperScrews and these next 2 are your other options; bit.ly/HexWasherHead10 & bit.ly/HexWasherHead8

    • @OakMerchantSolutions
      @OakMerchantSolutions 4 ปีที่แล้ว +1

      @@ConstructionKronies Really appreciate it!!!
      !

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว

      @@OakMerchantSolutions Anytime!!!

  • @minterrrrrr
    @minterrrrrr 2 ปีที่แล้ว +1

    I've been told to make the door hinge side of the wall the longer side. So that the floater is on the wall coming perpendicular. Was told this because after a while that small piece of drywall will start to crack if only 3 1/2" or so. having it slide through makes it longer and less susceptible to that. Is this true? Because ive seen both on job sites but told that the way shown is wrong. Thanks

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      This is actually a long time debate. At the end of the day I don't think it really matters. What really matters here is the fire rating and details around that. We are seeing a new trend in codes requiring hard corners and floaters are being limited. Just know your local code and do what the guy paying you wants. As for the piece cracking that will not happen. Its a taped inside corner and either covered by trim or slipped inside a welded frame.

    • @alex46801
      @alex46801 ปีที่แล้ว

      You are correct, floater goes on the other perpendicular wall. Easier to hang drywall too.

  • @christophercoy972
    @christophercoy972 4 ปีที่แล้ว +2

    Very informative video i usually do wood framing but im finishing a basement and would rather do metal plus metal framing is actually cheaper than wood but one question which shots do i use for the ramset for the metal tracks if you know

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว

      Yeah the Ramset should have steel to concrete and steel to steel. If you ask a clerk they should be able to tell you. I'll try to look them up and link them too!!

  • @arpitswadia3340
    @arpitswadia3340 2 ปีที่แล้ว +1

    How to calculate no of screws needed for 16" o/c? If we have room dimensions 14'*12 and wall ht on all 4 sides 10'? The total area would be 520 SF, right? Can you please confirm the quantities which I have calculated are correct or not? If not can you please share a link to your video or a detailed explanation about the calculation of materials for drywall installation on metal studs?
    Total Area= 520 SF
    Total track= 52LF/1.33= 39 plus corners= 2*1.5=3 so total= 39+3= 42*2=84 including top & bottom
    Drywall area= 1040 SF on both sides.
    No of sheets= 520/32=17 sheets*2= 34 sheets (4'*8')
    No of screws= total area*12/16= 520*12/16=390 screws will need it right?
    All of these are correct or did I make mistake? If you have any video figuring out all the materials as far as estimating drywall materials for commercial construction is concerned then it would be great.

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Hey there, thanks for the question. It's important not to complicate it. First tip is to round up to even numbers of standard material sizes. For a 14x12 you will need 12 pieces of track (10' lengths) and you need 1 stud for every foot of wall when its 16" o.c. so 52 l.f you need 52 studs. Drywall get 10' sheets and you will need 26 sheets minimum and I would always get and extra sheet or two. Screws come in boxes so grab a 5lbs pack of 1-1/4" drywall and a 5lbs box of framing wafers. For the mud, count your corner beads, get 1 500' roll of 2" tape, 2 boxes yellow and 2 boxes greeen! That'll get er done!

    • @arpitswadia3340
      @arpitswadia3340 2 ปีที่แล้ว

      @@ConstructionKronies thanks for the reply, I didn’t get it. I have some doubts. Would it possible for you to connect over zoom or any other platform so I can ask some questions back & forth?if you don’t mind??

    • @arpitswadia3340
      @arpitswadia3340 2 ปีที่แล้ว

      @@ConstructionKronies Thanks a lot for your response. I understood, as far as track & studs are concerned but how did you end up with 26 sheets of drywall? have you used 4'*12' of drywall? How many screws come per LB per 1 box if I want to calculate skews in numbers?

    • @arpitswadia3340
      @arpitswadia3340 2 ปีที่แล้ว

      @@ConstructionKronies I haven't received a response from you?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Use 4'x10' sheets (40sf) instead 8' sheets. You will save on taping joints and not have to cut the sheets tomdit.on 10' studs. Screws go every 8" in the bevels, 16" in the field studs and 4 on top and 4 on bottom.

  • @kojoenu1402
    @kojoenu1402 หลายเดือนก่อน +1

    Wood framer trying to learn metal. What’s the main reason or reasons that the drywall always gets “passed thru”. Is it for strength, air sealing etc?? With wood we always just add studs at all inside corners to catch the drywall so that part is confusing me. I understand the execution but my brain wants to know why it’s needed lol.

    • @ConstructionKronies
      @ConstructionKronies  หลายเดือนก่อน

      I think it's simply to use less material. Over a large office building that's a lot of studs that don't need to be added.

    • @kojoenu1402
      @kojoenu1402 หลายเดือนก่อน

      Got it, makes sense. One additional question …when you have a wall intersecting another wall (forms a tee). Don’t you still need a stud at the intersection to screw the flapper/slammer into? Or does it just get screwed to the top and bottom tracks and call it a day? Thanks for the replies I appreciate it!

    • @ConstructionKronies
      @ConstructionKronies  27 วันที่ผ่านมา

      Awwh man I hate when I miss replies, sorry mate. What we do is attach the 2 top tracks together, cut a flap about a 1/4" smaller than the adjoining track size and put 4 screws in it. Leave the bottom track back 3/4" to let the boards slip through easy. Use the floater and when the board passes through screw through the brown side into into it with 1-1/4's every 2', 1 in the top and bottom through the other tracks from the white side its really strong.

  • @ndaworld07
    @ndaworld07 2 ปีที่แล้ว +1

    Sorry for the back to back questions, but which layout do I use for corners of a room where foundation walls are forming the corner? Is that considered an inside corner or outside corner? If it’s an outside corner, and I have foundation wall up against it, would I just screw from the corner stud INTO the track as opposed to going from the track into the corner stud?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      Yes exactly. I use crimpers for light gauge as well for the backsides you can't get a drill in, just do a small half crimp and toss a screw in.

    • @ndaworld07
      @ndaworld07 2 ปีที่แล้ว +1

      @@ConstructionKronies ok awesome, so that’s considered an “outside” corner, correct?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      every corner will have an inside and outside. Sometimes we only drywall one side.

  • @nelsonros4221
    @nelsonros4221 3 ปีที่แล้ว +1

    Good tutorial. I am planning to create some partitions for classrooms, but the top track does not go to the roof. It means that there is a space about 20 inches in between them. Do you think it will be strong or weak?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      It depends. You can use stronger steel, can add sections that do go all the way up, tie into structural columns, I would need to know more. Sometimes we do offices and the walls are weak but tighten up with drywall. You can add structural type half columns into walls as well to strengthen them. I'd go 20 gauge steel with 5/8" type x drywall.

  • @filmmakerdude
    @filmmakerdude 3 ปีที่แล้ว +1

    Thanks for your videos. Im outfitting my basement and first time using metal studs, Im installing a small kitchen, so my question is... to support the upper kitchen cupboards, should I use 25 gauge or 20 gauge studs?

    • @filmmakerdude
      @filmmakerdude 3 ปีที่แล้ว +1

      actually I've been looking for a video explaining the structural differences between these two gauges and if I really need to use 20 if 25 would do the trick (being skimpy on an unemployed budget)

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      OMG man I am so sorry I missed your comment. I hope this finds you in time. You can use any gauge of steel stud just install 3/4" backing in between them wherever you need structure to hang stuff.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Yes sorry you can totally use the 25 gauge. You won't need 20 gauge anywhere in the basement.

    • @filmmakerdude
      @filmmakerdude 3 ปีที่แล้ว +1

      @@ConstructionKronies Thanks man, I appreciate you. One other question...hanging drywall ceiling is ok too for 25 gauge?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      @@filmmakerdude yes 100%, the only thing you need for your ceiling is furring bar and angle. I can teach you exactly how to install it. You can use studs and track as well. It all depends on bulk pricing and if it's worth it to just use the stud and track for everything or buy the 7/8" furring bar 25 gauge and 25 gauge 1-1/4" angle.

  • @OffTheClockNow
    @OffTheClockNow 3 ปีที่แล้ว +1

    Great drawings information, the words are less clear without the drawings! But that's my inexperience confusion in sure. What's the purpose of the caulking - sealer, glue, what?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      The caulking is for moisture and separation between substrates. Every wall either has either caulking (interior walls) or foam gasket (exterior walls). It is also an acoustical treatment. Cheers for the feedback I am always wanting to improve so thank you!!!

  • @simpilotguy
    @simpilotguy 3 ปีที่แล้ว +1

    Given the price of wood, I am considering using metal framing for my basement. Plan on using pressure treated plate on bottom. My question is how to do the ceilings? Should I just drywall my entire ceiling first? Or can I still do it as normal and frame the walls first, then drywall the ceiling, and finally drywall the walls. With the floater not being connected, the order doesn't really matter?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      Don't use the pressure treated plate for the bottom just use steel stud track and caulk it with chemtron. Frame the exterior walls first. You can drywall your ceiling and then frame your interior partitions. After that frame and board your bulkheads and drop ceilings. If you have any questions at all let me know. You can send me pics and I can help you even more!!

    • @simpilotguy
      @simpilotguy 3 ปีที่แล้ว +1

      @@ConstructionKronies My thought for using pressure treated lumber, was to leave gaps so that if a wall leaks, I will be able to find it, instead of trapping it behind the wall. But I would only do this on the exterior and not the interior partitions. Do you have a video on how to frame bulkheads with metal? I need to span 8' from side to side. How would you recommend doing that? I assume using 1-1/2" corner angle and track? Thanks for the quick reply!

  • @RONNIEJNZN
    @RONNIEJNZN 2 ปีที่แล้ว +1

    Knowing nothing about framing or drywall, why put the drywall into the stud and tie it in ? Would it not complicate replacing the drywall in the future ? Thanks for the video, very informative.

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      Some regions are taking the floater stud away and making you put in hard corners everywhere. The floater is great, it saves you a stud on corners and gives a great amount of strength. Replacing it does suck because you have to cut it down at the corner and add a stud but that is rare and usually will be years down the road. At the end of the day you can do whatever you want here as long as your following the job specs.

    • @RONNIEJNZN
      @RONNIEJNZN 2 ปีที่แล้ว +1

      @@ConstructionKronies thank you for the reply

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      @@RONNIEJNZN you bet, I hope that makes sense bro!

  • @jorgecruz4357
    @jorgecruz4357 3 ปีที่แล้ว +1

    I like to run the Track on the door at ather way , when are welding door is easy to run the drywall in side the frame , all framers need to think as are they hanging the drywall!

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Yes, the drywall is the final step in setting.a.door frame it's good when the framer considers the drywall and the boarder knows to get the hinge side locked in first with a laser level.

  • @christophercoy972
    @christophercoy972 3 ปีที่แล้ว +1

    Just curious but when you put the 2 studs on each side of the framing for the doors why do you space them out the size of the sheet rock rather than have them butting up to each other like to understand things

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Hello Christopher. My apologies for the late reply I was out at the lake for 4 days and had no reception. I am not sure if I understand your question but what I think your saying is: The doors come in different widths for drywall. We level our walls and plumb up the studs so we can use the drywall to space the frames. Fire code demands the drywall to slip in behind the casing of the steal frames. We add a second door stud in after the door clips are screwed in. We don't put drywall in between those studs. I hope this helps clarify.

  • @noegadea2670
    @noegadea2670 4 ปีที่แล้ว +1

    Videos asi me gustan. Do it more. Thanks

  • @randyjonscher5381
    @randyjonscher5381 4 ปีที่แล้ว +1

    Do you not have to put 2 studs on each side of the door?

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว

      Yes sometimes. Some designers will specify double studs. I always reccomend using 20 gauge studs for your doors in light gauge walls instead of 2 light gauge studs.

  • @shaneperry3968
    @shaneperry3968 2 ปีที่แล้ว

    Do you fasten the floater studs at the top and just leave the bottom loose? Or is the whole stud loose?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว +1

      It's best to leave the whole stud loose. But 2 things, sometimes you need to put 1 screw in at the top for safety. If it's a high wall or light gauge something that could fall out and hit someone and 2 the general contractor may have it in the rules to put 1 in. They will tell you if there have that rule don't ask cause they will always say yes 👍

    • @shaneperry3968
      @shaneperry3968 2 ปีที่แล้ว

      @@ConstructionKronies Fully noted. Thank you so much for the solid advice as well as the rapid response. Much appreciated!!

    • @admcalister
      @admcalister 2 ปีที่แล้ว

      @@ConstructionKronies why go to the effort of 1 at the top, when 1 at the bottom is enough, and can work your way upwards? Not sure about some of your practises

  • @danialmirzaimatin7194
    @danialmirzaimatin7194 3 ปีที่แล้ว +1

    Hi, I've been watching your videos for last 2 days, and I need some expert help on my project. I want to build a 80 ft long drywall with 18ft height and another 26ft long wall next to it, so basically an L shape. I was wondering do I need some sort of support behind the wall? because it's too long. any suggestions on this would be great, thank you.

    • @danialmirzaimatin7194
      @danialmirzaimatin7194 3 ปีที่แล้ว +1

      oh, and we are planning to build it in a warehouse

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +1

      Sure I have lots of pointers for you. It may be best to jump on a zoom call so I can more info and draw it out for you. Or I could do a livestream and leave it up on TH-cam for you. Busy days but I do have some evening time to spare.

    • @danialmirzaimatin7194
      @danialmirzaimatin7194 3 ปีที่แล้ว +1

      @@ConstructionKronies both ways are perfect thank you, any way which is easier for you. I really need some help on this project, and I really like your work, you make everything seems easy 😃

  • @simpilotguy
    @simpilotguy 3 ปีที่แล้ว

    So, one thing I don't think you explained was how to mark off the studs after a floater. Do I just add the drywall thickness to the 16" oc?

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      yes thats right. We plan the drywall layout and then transfer that to our centers by adding the thickness of the board.

  • @1mandrywallarmytv144
    @1mandrywallarmytv144 2 ปีที่แล้ว

    personally I run my slammer stud on the other wall. To me a 81/2 inch wall is stronger than the 4 1/4 wall. Regardless the way you did it will work but my way is better. Good video !

  • @hollosym
    @hollosym 3 ปีที่แล้ว +2

    Why are you caulking the bottom of the track? Seems useless if you're driving a nail through it to secure it to the cement.
    What length nails do you recommend for the bottom track?
    What's your stance on using a crimping tool vs. pan head screws to secure the metal studs in the track? My inspector said to use a $20 crimper as it's much faster, easier, and leaves your stud flush (no pan head).

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      The reason why we caulk the bottom track is to achieve proper thermal and moisture bridging between the change in materials. It is usually code to use 1-1/4" pin bolts and the 3/4" direct fastening pins for say a Hilti or Ramset. Crimpers are $100 here but they are the standard ones we use in the trade so maybe better quality. I think crimping the top track ONLY on the far side is perfectly fine so out of the 4 possible screws you are only using 3 plus a crimp. I use the crimpers for studs I can't get my gun into the space to screw off. However a lot of guys use them for the the backsides completely both top and bottom and only screw in the front side. I am a heavy gauge steel guy, rarely do I do light gauge so I like to make everything super strong and use screws everywhere possible. That is just me though.

  • @misterbowers
    @misterbowers 3 ปีที่แล้ว +1

    Readying myself for an apprenticeship for metal studs and Sheetrock, this video is awesome and I learned a lot Thankyou! 🙌🙌

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      That's awesome man! Please let me know if you have any questions!

  • @JuanitoGT502
    @JuanitoGT502 2 ปีที่แล้ว +1

    Good, the way I do is cut the drywall 1-1/4" and slide in then screw it together

  • @nickandnicksconstructionti9508
    @nickandnicksconstructionti9508 3 ปีที่แล้ว +2

    I personally use one wood stud on the corners for doors bc I like my stuff to be build likes brick wall . I looked this up bc I haven’t done steal studs in over 20 years so I need a refresher course n this is great to help someone’s memory come back . I think it may be confusing for someone new though I’m 35 years in this field 👍

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Hey thanks for stopping in! Very good to know an experienced guys opinion for real 👍

  • @jldonosobarrera
    @jldonosobarrera 3 ปีที่แล้ว

    Thanks for the video mate but there are two things that I am still doubtful about: 1) I don't think that screwing on gyprock is compliant to any code. Plasterboards are not for structural use and since you are screwing the backface of the boards onto the stud on the opposite side that leaves me a bit confused, although I understand that what you are trying to do is to ultimately join two metal studs together, but that piece of plaster shouldn't be sandwiched in there. 2) Plasterboards should be screwed sideways to provide cross-bracing to the wall.

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว +2

      Hey my man! Thanks for the comment. We lock the corners in like that to provide more stability in the wall. Locking in the floaters is a standard practice for all drywallers. 2) Steel stud requires you to "stand-up" your sheets to achieve fire rating and it provides a nicer finish with less taping joints. We only "lay-down" drywall on wood studs. On steel stud you stagger your joints on the opposite side of the wall. The only circumstance you can "laydown" drywall on steel stud is when you can't land the bevels on a center (of stud) for example; a plumbing wall. Hope that makes sense to ya!

  • @imnotfeelingit207
    @imnotfeelingit207 หลายเดือนก่อน +1

    Im 28 got a contract job to build new office said i can never did metal studs before lol ill let yall know if this video works or not start my job the 16th of December 😅

    • @ConstructionKronies
      @ConstructionKronies  29 วันที่ผ่านมา

      If you need help email me, chris@constructionkronies.com and I'll do what I can.

  • @amoscardoza5253
    @amoscardoza5253 4 ปีที่แล้ว +1

    Yo kronie!

  • @teamimprex1023
    @teamimprex1023 2 ปีที่แล้ว +1

    Can you overlap either way?

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Sure you can, just not where doors are. I saw your other comment about zooming in, I send the pdfs to guys who email me at chris@constructionkronies.com!

    • @admcalister
      @admcalister 2 ปีที่แล้ว

      Been doing this trade for 10 years, wondering why the overlap of metel? No point unless serious soft screed to fix to? Just nail the metal down and place adjacent metal separate, only make other peoples work harder

    • @millidonmusic1147
      @millidonmusic1147 2 ปีที่แล้ว

      I would love to work with you what does it take.??
      I love the trade

  • @jhonyrodriguez9002
    @jhonyrodriguez9002 3 ปีที่แล้ว +1

    No insolation needed inside the walls??🤔

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      No, not all walls have insulation. The client did not want it on this job.

  • @emanuelquinones2534
    @emanuelquinones2534 2 ปีที่แล้ว +1

    show how you fasten it

  • @merzflex519
    @merzflex519 4 ปีที่แล้ว +1

    👍

  • @SafetyFooT
    @SafetyFooT 3 ปีที่แล้ว +1

    steel studs no gloves :O straight up gangsta sh*t son :O

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      yes man, gloves are important. When I am doing light gauge I don't always wear gloves but as soon as i go to 20 gauge or lower i will for sure. My hands are like wooden paddles man haha!

  • @RobertMoriarty
    @RobertMoriarty 4 หลายเดือนก่อน +1

    “I’d use an angle grinder.”
    -My boss, 2024

  • @ryandauphin5429
    @ryandauphin5429 2 ปีที่แล้ว +1

    Not sure why you lap your bottom track

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      Hey my guy! It's to give you strength and accuracy for sure. It also acts as a full system with the floater studs and locking the drywall in. Gives you both fire rating and strength. Also, we copy the same on the top track and that gives you many benefits when most walls don't go all the way up to the deck.

  • @noegadea2670
    @noegadea2670 3 ปีที่แล้ว +1

    More framing body

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      You got it!! Wait until my studio is finished being built I will be doing a lot of tutorials on framing from it!! Thanks for commenting!

    • @ConstructionKronies
      @ConstructionKronies  3 ปีที่แล้ว

      Here is the link to my framing playlist th-cam.com/play/PLRtmYu3z-FENOxNCqdjW0ey47mSNc5Klm.html

  • @konamanstudio2447
    @konamanstudio2447 4 ปีที่แล้ว +1

    👍🏽🍻🍺👍🏼

    • @ConstructionKronies
      @ConstructionKronies  4 ปีที่แล้ว

      Cheers with beers bro!! Thanks for the idea about doing my videos like this. They are performing better than all my other videos!!!!

  • @tonybudetti
    @tonybudetti 2 ปีที่แล้ว +1

    WEAR FREAKING GLOVES PEOPLE!!!!!!!!

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      That's good advice, I don't always wear gloves when framing light gauge but always with heavy gauge. My hands are leather bro, but you are right we should always have them.

  • @shaneash1598
    @shaneash1598 ปีที่แล้ว +1

    I'd advise anyone who finds this interesting to go trade school as a "lather" ISM carpenter get certified

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      That's great advice! We just lost our ISM program at the local trade school here, very sad.

  • @AMindInOverdrive
    @AMindInOverdrive 2 ปีที่แล้ว +1

    If you want to know if a guy is a good boarder, ask the taper who comes after him ;-)

  • @alex46801
    @alex46801 ปีที่แล้ว

    Drywall should be one piece around the door frame, that little 3" cut leg on hinge side is weak and should've ran through to the other wall.

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      Again, another misconception. You do you bro all good, we utilize drywall to minimize scrap and joints, the standard door frame is drywalled in 3 pieces, your full piece, buck piece and leg like I show you in the video.

    • @alex46801
      @alex46801 ปีที่แล้ว

      @@ConstructionKronies you do drywall to minimizing scraps and JOINTS but you decided to 3 piece it lol?
      No misconceptions whatsoever as a couple other guys who knows what they're doing also called you out on it.
      The most important part is putting drywall around a door that constantly twist the king stud leading to cracks.
      You're supposed to 1 piece it by notching the sheet of drywall and break on a cripple and the fact that you had to 2 piece it tells me you're mediocre at best.
      We appreciate the videos though and you mean well but you're perpetuating a new generation of hacks.

    • @ConstructionKronies
      @ConstructionKronies  ปีที่แล้ว

      @@alex46801 I whole heartedly disagree with you. It will not ever twist or crack. The secret is to tie in the floater stud first. Your way is only good when doing the outside first, we try to always do the inside first. At the end of the day its going to be the same strength. Trust me bro, been doing this for 30 years and I haven't seen your way since my early days. I have never 1 time been called back to a job (I offer a 5 year warranty) to fix anything. This is something we have debated in the past on this channel. Respect bro, what we do is not easy, its a tough job. I appreciate your insight!

    • @alex46801
      @alex46801 ปีที่แล้ว

      @@ConstructionKronies "trust me bro" for a 5 year warranty, no thanks 😂😂😂

  • @jenderarevalo
    @jenderarevalo 2 ปีที่แล้ว +1

    Why dont you show how to cut a conner thats at a 45 degree angle like a ferdown you dont know how to do it do you lol

    • @ConstructionKronies
      @ConstructionKronies  2 ปีที่แล้ว

      I dunno man, thats very very tricky.... haha! I have shown them in past vids and I have 2 of them in this new job! I will show ya!

  • @tomeck3902
    @tomeck3902 ปีที่แล้ว

    That’s not leaving up to 4-1:4 that’s Leung 5/8 now 4-1/2 leaves a 1/4 oG play