Let's Fix This DC-AC Power Inverter

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ธ.ค. 2024

ความคิดเห็น • 54

  • @paulcastillo30
    @paulcastillo30 ปีที่แล้ว +2

    Very thorough and clearly explained. Nice catch on the thermal sensor!

  • @joelstienlet1641
    @joelstienlet1641 ปีที่แล้ว +1

    Congratulations for this repair! I think it is also important to mention that, when replacing an electrolytic capacitor, the case may also be at an high potential. For example, TDK says, I cite: " Single-ended, SMD, snap-in, and screw terminal capacitors have an undefined electrical contact through electrolyte or other parts inside the case". So when replacing the cap with another cap of another diameter, the insulation clearance will vary, and it is important to respect the minimum clearance according to the local regulation.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว +1

      Correct about the capacitor case being at a voltage potential. In this case both terminals of the cap are floating above ground potential. It is good practice to make sure nothing comes in close contact with the side of the capacitor and especially the top of the capacitor which is tied to the negative lead and the top of the capacitor is not insulated.

  • @surgingcircuits6955
    @surgingcircuits6955 ปีที่แล้ว +3

    Extremely well done. New Subscriber. Quality work - refreshing. Everything clean and organized. No ram/cram/jam ... took your time to do a great job. Looking forward to watching more of your vids, and appreciate the share.

  • @simontay4851
    @simontay4851 ปีที่แล้ว +3

    The capacitor you took out is correct and perfectly fine. The 450V cap is for the european 240V AC version, which would see about 370V DC. In your US version, the cap will have about 180V DC on it. The DC voltage will be a bit higher than the peak of the AC output to account for the MOSFET on resistance.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว

      Yes after taking actual voltage measurements I realized the original cap's rating was ok. I show this in the video. My replacement is a high quality Nichicon with the same 220uF rating, just a higher voltage rating which is perfectly fine to use.

  • @eliasbourozrrrs8585
    @eliasbourozrrrs8585 ปีที่แล้ว +1

    I liked your video dear,very nice video ,nice prescription

  • @robbo6460
    @robbo6460 ปีที่แล้ว +1

    Another excellent video. Thanks

  • @vianacode
    @vianacode ปีที่แล้ว +2

    Great info. Nice and clean job!

  • @nikospar3624
    @nikospar3624 ปีที่แล้ว +1

    Very nice, thank you.

  • @mikesam4951
    @mikesam4951 6 หลายเดือนก่อน +1

    Great work and video, thank you!

  • @sebastian_harnisch
    @sebastian_harnisch ปีที่แล้ว

    Nice job. One thing to mention for someone not that experienced: Measuring MOSFETs with a DMM can be somewhat missleading sometimes. The voltage applied to the gate by measuring continuity between gate and source can be enough to make the drain-source Path (partialy) conducting. Touching the gate and source can be enough to discharge the gate again making the MOSFET non-conducting again. In this case it certainly looks like a dead short though. (A good component tester makes it a bit easier to avoid such problems.)

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว

      Hi, thanks, and yes I would normally use a component tester to carefully and accurately check a MOSFET but these were completely destroyed. I could tell that something was defective from the short circuit reading as I worked back through the circuit.

  • @BjornV78
    @BjornV78 ปีที่แล้ว +2

    Nice repair 👍👍👍

    • @AlejandroLopez-qd3xm
      @AlejandroLopez-qd3xm ปีที่แล้ว +1

      You always want to check the gate resistores of any failed mosfet, they often blow open and next time you put a healthy device, it will be destroyed

    • @ovalwingnut
      @ovalwingnut ปีที่แล้ว +1

      Yes, BJ. I agree. It was actually a quality ɹǝʇɹǝʌuᴉ to boot... who would have thunk.

  • @rosschizzoniti906
    @rosschizzoniti906 ปีที่แล้ว +1

    That thermistor is very important as it will activate the fan for cooling the mosfets it should be mounted on the heat sink with a clamp . A common problem with mosfets and dud capacitors in inverters

  • @bobbybiggs4348
    @bobbybiggs4348 8 วันที่ผ่านมา

    27:06 I wonder if they've chosen the components to suit the target output voltage? If it were to output 240-250v then 450v would make sense.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  7 วันที่ผ่านมา

      Yes correct that is what was done.

    • @bobbybiggs4348
      @bobbybiggs4348 7 วันที่ผ่านมา

      @EriksElectronicsWorkbench my apologies, lol, I only saw how many other people made that same comment after I had published mine. You must be very patient.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  7 วันที่ผ่านมา

      ​@@bobbybiggs4348 no worries, it's a valid point about the voltage. Thanks for taking time to watch.

  • @CharlesVanNoland
    @CharlesVanNoland ปีที่แล้ว

    Are there other options for scoping the AC wave of an inverter besides an isolated battery-powered scope? Is there any alternative, or any way to take a wall-plugged scope and isolate at least the current from the inverter to make it safe(er)?

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว +2

      If you want to use an AC line powered oscilloscope with traditional grounding on the AC line you need to use a differential scope probe. This will allow you to probe a circuit with reference to a point that is not at ground potential. Don't float the oscilloscope with an isolation transformer as this is dangerous and will put high voltage on the scope chassis.

    • @mcac-youtube
      @mcac-youtube ปีที่แล้ว

      @@EriksElectronicsWorkbench a isolated transformer in the scope will not put high voltage in the chassis, it will do only if there is leakage in the scope circuit. And if use another isolated tranformer to power the AC equipament under test the risk not exist.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว

      Isolating the scope from ground creates a hazard when your probe's "ground" connection is at a voltage potential (above or below ground reference) which then raises the oscilloscope chassis above (or below) ground and poses a dangerous shock hazard. Users try to do this when testing switchmode power supplies for example.
      Isolating the scope from the AC line should only be done if you are actually servicing the scope.
      I'm currently working on a Tek 2247A and the power supply board has a factory inscribed note to use an isolation transformer when servicing. @@mcac-youtube

  • @davidknightaudio934
    @davidknightaudio934 ปีที่แล้ว +1

    the capacitor is right they halv its value/double voltage foe 240 v models the one you put is for 240 not 110 version

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว

      Yes the capacitor chosen by the manufacture was ok. The capacitor I put in has a higher voltage rating which is also ok to use.

  • @gorak9000
    @gorak9000 2 หลายเดือนก่อน +1

    KME is a united chemi-con (or nippon chemi-con - same company) series, and that's the United logo - they're just as good as nichicon. Caps I'd trust are (united/nippon) chemi-con, rubycon, nichicon, and panasonic. They're all top-tier brands (some particular bad series in all of them excluded - even the good companies have had notoriously bad series of caps in the past)

    • @gorak9000
      @gorak9000 2 หลายเดือนก่อน +1

      47:08 you can also use HV/isolated probes on a regular scope. They used to be stupidly expensive, but micsig has some reasonably priced options these days - essential for working on the primary sides of switching power supplies, or vector motor drives!

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  2 หลายเดือนก่อน

      Thanks for the info. Yes true some bad series were produced here and there but the names you mention are trusted companies.

    • @AnnaVannieuwenhuyse
      @AnnaVannieuwenhuyse หลายเดือนก่อน +1

      @@EriksElectronicsWorkbench I also trust Elna, Epcos (TDK nowadays) Yageo's brands (Yageo and Jamicon) and a few others for certain purposes. NKK are another accepted one in my bin. Cornell Dubilier make a lot of specialty caps used in old gear and I trust those too -- expect no less at that kind of price.
      I trust a fair few "cheap brands" for a fair few purposes as well. It's just a matter of picking the right capacitor for the job. I'm very happy with a lot of my Samwha capacitors.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  หลายเดือนก่อน

      @@AnnaVannieuwenhuyse I have had good luck with Vishay, Epcos, Yageo, Cornell Dubilier. For many repairs Nichicon and Panasonic are go-to for high quality and cost effective but other brands are always worth considering.

  • @marks5816
    @marks5816 ปีที่แล้ว +1

    put a piece of scotch tape on it to bring out the letters

  • @andymouse
    @andymouse ปีที่แล้ว

    Cheers.

  • @NikolajSchelepa
    @NikolajSchelepa ปีที่แล้ว

    What's the tool called 15:30?

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  ปีที่แล้ว

      Hakko FR-301 Desoldering Tool, hakkousa.com/fr-301-portable-desoldering-tool.html

  • @FireballXL55
    @FireballXL55 3 หลายเดือนก่อน

    I am guessing the 450V rating is when it is a 220VAC version. LOL just got to 40min in the vid.

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  3 หลายเดือนก่อน

      yes it would have the higher voltage rating for the 220 volt AC version

  • @paul.alarner6410
    @paul.alarner6410 17 วันที่ผ่านมา

    lucky repair ,normaly takes out the fet drivers when they go chernobyle!.

  • @CharlesVanNoland
    @CharlesVanNoland ปีที่แล้ว

    P.S.: Subbed ;)

  • @tanaseav
    @tanaseav 11 วันที่ผ่านมา

    There is no way in hell that you can damage a mosfet made after 1990 by handling it. Maybe if you charge on a Van de Graaf machine and discharge directly on the gate... and even so i don't think it would brake a sweat....
    It's more likely to fry a BC509 or other puny fuckers, than a big ass mosfet...

    • @EriksElectronicsWorkbench
      @EriksElectronicsWorkbench  11 วันที่ผ่านมา

      Sure you can. All it takes is a static charge on the gate terminal. You can easily build up 100's or 1000's of volts if you are not ESD protected. toshiba.semicon-storage.com/ap-en/semiconductor/knowledge/faq/mosfet/mos-is-sensitive-to-static-electricityhow-do-you-protect-mosfets.html

  • @ovalwingnut
    @ovalwingnut ปีที่แล้ว +2

    I rate this video a "4C" For CLEAR, CONCISE and COMPLETE CONTENT :O) I really enjoyed this last hour. Points for "post editing, staging and follow up tips". You R the "Circuit Whisperer". ʞɔoɹ noʎ