Pole/Conductor replacement on 3 phase line 12kv

แชร์
ฝัง
  • เผยแพร่เมื่อ 20 ม.ค. 2025

ความคิดเห็น • 133

  • @Bobsdecline
    @Bobsdecline  3 ปีที่แล้ว +49

    Merry er... ahh.... guess I was a bit late with the editing on this one!🎄🤔😂
    Just ignore that part! 😇. Things have been hectic, what else is new!?

    • @GlenBixley
      @GlenBixley 3 ปีที่แล้ว +1

      Never late,
      Im sure most understand that time is limited and editing footage like this takes some time.
      Happy New Year and thank you for the informative content.

    • @jimturtle6223
      @jimturtle6223 3 ปีที่แล้ว +3

      Yeah but you definitely gotta tell us what you did the night of the blizzard after you ended the live chat. The suspense....lol

    • @Blackwolfster
      @Blackwolfster 3 ปีที่แล้ว

      Happy Easter! Oh wait to soon?!

  • @johnblair8146
    @johnblair8146 3 ปีที่แล้ว +15

    A few years ago I watched a crew replace several towers on a 115 kv line. NO OUTAGES!!!!! Those guys were at the top of their game!!!!!

  • @Kini_the_Fox
    @Kini_the_Fox 3 ปีที่แล้ว +1

    love the bit at the end. "just be happy guys" 😊

  • @jeffreykornspan9053
    @jeffreykornspan9053 3 ปีที่แล้ว +2

    Thanks for the tour Aaron,

  • @justanotherguy8791
    @justanotherguy8791 3 ปีที่แล้ว +2

    sounds like half million dollar upgrade. thanks for the video.

  • @jcraigshelton
    @jcraigshelton 3 ปีที่แล้ว +2

    RN from Texas. Enjoy your channel man! Be safe!

  • @danielnigra1922
    @danielnigra1922 2 ปีที่แล้ว +2

    Great video Aaron.

  • @alecthenice8115
    @alecthenice8115 3 ปีที่แล้ว +2

    I love outtage work with a ton of crews

  • @Samanthareneeheart1
    @Samanthareneeheart1 3 ปีที่แล้ว +16

    Your Chanel is always informative & educational in the aspect your telling us how things are done with what you CAN tell.

  • @michaelgagne1911
    @michaelgagne1911 3 ปีที่แล้ว +2

    Ah think I deleted my own comment this was really one of your better videos very educational thank too all u lineworkers out there God bless all of u men and women please keep your videos coming u did a great job with this one Mike from iron river m.i.

  • @Renville80
    @Renville80 ปีที่แล้ว +2

    In my area my power company has been rebuilding the distribution system so the voltage can be upgraded from 4160 volts to 13.8kV. It is interesting to see how they proceed, from simply changing out insulators on poles that are still usable all the way to complete pole replacements. As in the video, when the circuits were ready for cutover, they took an outage and sent out an army of linemen to change the transformers or the tap switch on the primary side (the company has begun using cans that can be set for 2400, 7200, or 7970 volt primary). The pace of conversions have slowed down since a goof in a neighboring town where they forgot to reset the transformers on one branch line before switching over to the higher voltage.

  • @VariacManiac
    @VariacManiac 3 ปีที่แล้ว +5

    3rd! When I was a kid, I always asked for insulators when I saw a rebuild. Interesting to see how companies do the same tasks differently. Thanks for showing man! 🤙

  • @avsrule247
    @avsrule247 3 ปีที่แล้ว +9

    I love that understanding of relatively simple physics keeps everyone safe while working live. One of the first things I do when I have an apprentice with me (residential/commercial electrician) is teach them the basics of protecting yourself and working safe, how to check for 120/240V etc.

    • @twothreebravo
      @twothreebravo 3 ปีที่แล้ว +1

      Ohm's Law! Physics is your friend.

    • @alecthenice8115
      @alecthenice8115 3 ปีที่แล้ว

      You teach them to path it through their fingers right??

    • @avsrule247
      @avsrule247 3 ปีที่แล้ว +1

      @@alecthenice8115 Lol. I teach them to not path it thru any part of their body. Any path means you failed to follow instructions. When you work live you need 100% focus so you can be perfect at your work.

  • @sparky178
    @sparky178 3 ปีที่แล้ว +11

    Hi! I’m an electrical contractor from Green Bay, WI. I play with the small voltages! I enjoy watching your videos to give me a better understanding as to where and how the electricity is delivered to homes and businesses.

  • @S.S.H.OCT.18-08
    @S.S.H.OCT.18-08 2 ปีที่แล้ว +1

    I was on a reconductor crew for several years. We used those small ropes on a trailer, called a spider rig. On the day of the conductor pull we used the small ropes to pull a larger rope in called a bull rope. Then the bull rope was attached to the new conductor. Then we pulled the conductor in under tension as you said. If we hung the small ropes it was usually only done to prevent someone from cutting the rope at night and stealing it. We had this happen on one job. Theives stole so much of the spider rope we had to get new reels and restring them. I enjoyed reconductor work. It really makes you think every step.

  • @TheJmich2001
    @TheJmich2001 3 ปีที่แล้ว +1

    Thanks for letting us look over your shoulder! Be safe Brother...NJ

  • @akshonclip
    @akshonclip 3 ปีที่แล้ว +2

    Some BobsDecline with my lunch. Awesome 👏

  • @thomasschoenleber1519
    @thomasschoenleber1519 3 ปีที่แล้ว +2

    That rope system is called a spider reel, made by Sherman Reilly. Used them for the first time last Thursday to pull in two new spans of our systems sub transmission line of 34.5kv. Love this channel!

    • @yobi765
      @yobi765 3 ปีที่แล้ว

      Very cool.

  • @jaydauro7539
    @jaydauro7539 3 ปีที่แล้ว +8

    An amazing amount of pre-planning and preparation to make the changeover happen safely and smoothly. Thanks for going over this, we have a couple mile stretch being prepared for a changeover, now I have to go look closer at what they are doing.

  • @12voltvids
    @12voltvids 2 ปีที่แล้ว

    Wow NB Power has a Chevy Volt. Cool

  • @longviewstud26
    @longviewstud26 3 ปีที่แล้ว +2

    Excellent video

  • @baconmcbacon62
    @baconmcbacon62 3 ปีที่แล้ว +1

    Fist bump from Dallas. I love your videos. They’re fascinating as hell and I love learning about your trade. Hope you had a great holiday as well!

  • @Jimmy-wy8jp
    @Jimmy-wy8jp 3 ปีที่แล้ว +1

    The size of yalls trucks blow my mind. Love your content

  • @cdnaudioguy
    @cdnaudioguy 3 ปีที่แล้ว +2

    I'm not an electrician, but I have watched all your videos. I got more anxious thinking about having to move all those wires, pull all the ground bonding and double check everything than anything else I've seen. Those guys rock! Well, you rock too, but you know what I mean.

  • @mikeznel6048
    @mikeznel6048 3 ปีที่แล้ว +1

    Errr ahhh Merry Christmas Aaron and family lol. Happiest new year too! Awesome video. Thanks for sharing with us!

  • @twothreebravo
    @twothreebravo 3 ปีที่แล้ว +1

    They just did a big job like exactly this up the highway from where I live, great to have it explained in such great detail.

  • @Straycurrent
    @Straycurrent 3 ปีที่แล้ว +7

    So much planning and work. You guys do an amazing job.

  • @spud7378
    @spud7378 3 ปีที่แล้ว +1

    Great explanation and video Aaron!!!
    Hope you got some time off!

  • @ismaelabregana1493
    @ismaelabregana1493 3 ปีที่แล้ว

    Great job replacing conductor..stay safe always sir!! Wathching from Philippines!😊

  • @johnwalker890
    @johnwalker890 3 ปีที่แล้ว +1

    Good job Aaron.

  • @alan.macrae
    @alan.macrae 3 ปีที่แล้ว +3

    Always worth waiting for! Thanks Aaron and stay safe! 👊👊

  • @Quickstrike1981
    @Quickstrike1981 3 ปีที่แล้ว +1

    Epic, stay safe out there

  • @automotiveguru21
    @automotiveguru21 3 ปีที่แล้ว +1

    Hi Aaron, Another excellent video as always! Never too late for Merry Christmas wishes!

  • @TechOne7671
    @TechOne7671 3 ปีที่แล้ว +2

    Very good. As an electrician I find this interesting to see done and explained by someone who knows what their talking about.

  • @OldePhart
    @OldePhart 3 ปีที่แล้ว

    That was quite interesting. Big project. Thanks for sharing.

  • @TwistedxGamer101
    @TwistedxGamer101 3 ปีที่แล้ว +3

    Just found your channel and this is pretty cool. I work as a design engineer in FL and we are doing a job of hardening all distribution poles that are Florida Power and Light owned. A lot of work is done with miles of pole replacement and reconductoring either 13KV or 23KV lines. Pretty interesting stuff. I'm also interested in trying to become a line man myself and your channel has been super cool to find.

  • @johncharnley4451
    @johncharnley4451 3 ปีที่แล้ว

    I directed traffic for a couple crews doing this and it's pretty cool to watch

  • @three-phase562
    @three-phase562 3 ปีที่แล้ว +2

    Awesome job, hope all you guys stay safe out there!

  • @davevernon6315
    @davevernon6315 2 ปีที่แล้ว

    Fascinating video. Thanks for making it. The info about using rope as a pull cord for the lines really surprised me.

  • @jensonbeaver2678
    @jensonbeaver2678 3 ปีที่แล้ว

    great explaining and another great video!

  • @freethinkingamerican80
    @freethinkingamerican80 2 ปีที่แล้ว

    Good video! As a fellow JL I can appreciate how yall do things differently around the world. Never seen the reels of wire on the pole like that. Usually we just spread and set and run the new upgraded wire in between on the same arms. More than 1 way to skin a cat and appreciate new ways of doing things. Stay safe and see you on the ROW.

  • @eddieslittlestack7919
    @eddieslittlestack7919 3 ปีที่แล้ว

    Happy Wednesday the 12th my friend.
    Cool video, you’re obviously a professional.

  • @patmcnally6
    @patmcnally6 3 ปีที่แล้ว +1

    Happy New Year to you Aaron and your Family

  • @gordonreeder3451
    @gordonreeder3451 3 ปีที่แล้ว +3

    I've been watching this happen IRL. PGE, our local power company is a couple of years into a massive system upgrade. Substations are being expanded and new ones built, new transmission lines are being run, existing lines are being upgraded. Over the summer they replaced 3 miles of transmission line in one big pull. It was amazing to see. Then, almost right outside my window, they are relocating a mile of line to make way for a road widening project. They are pretty much done. Right now they are tearing down the last of the old line. Then they need to get to work on the new transmission they are building a mile away.

    • @ArtStoneUS
      @ArtStoneUS 2 ปีที่แล้ว

      All those millions of electric vehicles are going to need substantial infrastructure upgrades!

    • @gordonreeder3451
      @gordonreeder3451 2 ปีที่แล้ว

      @@ArtStoneUS That may very well be. But, in this case it's all the data centers that are being built in the area. The power needed to charge 100 electric cars pales in comparison to the power needed by one massive server farm.

    • @ArtStoneUS
      @ArtStoneUS 2 ปีที่แล้ว

      @@gordonreeder3451 According to energy.gov, data centers consume about 2% of total electricity in the United States. I'll let you do the math of what 10 million electric vehicles will need.

  • @davidca96
    @davidca96 3 ปีที่แล้ว

    great video thanks for sharing how its done

  • @allskillnoluck1053
    @allskillnoluck1053 3 ปีที่แล้ว +1

    It is crazy to see how other utilities go about there business I’m a east coast lineman working for a utility in alberta. Crazy how many ways there is to skin a cat

  • @DracoXul
    @DracoXul 2 ปีที่แล้ว

    Merry Christmas to you as well

  • @chrism9017
    @chrism9017 3 ปีที่แล้ว +1

    So cool!

  • @scottfeatherstone7156
    @scottfeatherstone7156 3 ปีที่แล้ว +1

    Very interesting

  • @paigebevier5124
    @paigebevier5124 3 ปีที่แล้ว +1

    Cool video

  • @keything8487
    @keything8487 3 ปีที่แล้ว +1

    great work !!...thank you for doing it !!...my limit is 480.

  • @TomStorey96
    @TomStorey96 3 ปีที่แล้ว +3

    I remember once when I was very young a new high voltage line was being built across our property (a farm). One day they were stringing up the conductors which started very low down to the ground. So I grabbed on to one or two and got hauled up into the air at a rate of knots.
    As a kid it was pretty fun. 😁

  • @robertlane6675
    @robertlane6675 3 ปีที่แล้ว +1

    I listen to my local power company on the scanner. One of the most frequent things I hear are techs calling dispatch asking for reclose control.

  • @danhall141
    @danhall141 3 ปีที่แล้ว +1

    Where is this filmed? The locations are absolutely beautiful

  • @ronblack7870
    @ronblack7870 2 ปีที่แล้ว

    they spent last summer replacing poles on a semi major street in my neighborhood. did it a couple at a time right next to the old pole . new pole is taller. then they cut the old pole lower which has cable and phone lines on it. so now they are doing the next parrallel road.

  • @trickytrav88
    @trickytrav88 3 ปีที่แล้ว

    Thanks for the vid. You always keep it interesting

  • @MORTAL-SKY
    @MORTAL-SKY 3 ปีที่แล้ว +1

    Do a video on a transformer banks, let’s get complicated!!! Go all out with it, rotation and all!

  • @EBTROUBLE
    @EBTROUBLE ปีที่แล้ว

    Single circuit….accessible … clean poles…. I love a gravy job

  • @timjorden8329
    @timjorden8329 3 ปีที่แล้ว

    They put several wind turbines up my road years ago. We use to just have 2 wires on each pole, they put a T on the top of each pole and put 4 lines. Bigger cable too..
    I remember them first running those different colered ropes.
    It was a big project

  • @jovetj
    @jovetj 2 ปีที่แล้ว

    I was hoping you'd demonstrate the tracking ground connections that sit on the new conductors as they're pulled to keep them grounded.

  • @thomaskane8137
    @thomaskane8137 3 ปีที่แล้ว +1

    Mental what yous do live. We have teams who at most move live HV on an inter pole and the other stuff of putting switches up etc😅😅

  • @grabasandwich
    @grabasandwich 3 ปีที่แล้ว +4

    Hey, I have a question. There's been widespread intermittent flickering on my side of the city for the past few days. Like 1 second outages, a couple times a day. Manitoba Hydro found the cause, but I'm curious if you could explain 1) what is actually happening (recloser?) And 2) Why does it take days sometimes to find? Thanks!

    • @joshbrown1806
      @joshbrown1806 3 ปีที่แล้ว +3

      It is the recloser that causes these “one second outages.” Sometimes the faults can be really hard to find such as a branch sitting on the arm. We have even seen trees in swampy areas blowing way over during wind gusts, laying on the line for a second, and then standing back upright. Extremely hard to find especially if it’s on a line that travels a long ways.

    • @grabasandwich
      @grabasandwich 3 ปีที่แล้ว

      @@joshbrown1806 They posted this after "update: crews figured out what’s causing the flickering (equipment issues) and we’re working to fix it. Thanks again for your patience." 🤔

    • @JCWren
      @JCWren 3 ปีที่แล้ว +1

      We had a similar issue for a couple weeks. I didn't hear what the resolution was, but the crew said it can be lines slapping together, tree branches, squirrels (seems like that one would only happen once for any given squirrel), failing switch gear, transformers (affected a couple streets, so it wasn't that), etc.

    • @joshbrown1806
      @joshbrown1806 3 ปีที่แล้ว +3

      @@JCWren squirrels can stay on the line after they die and just keep tripping the line or causing recloser action.

    • @JCWren
      @JCWren 3 ปีที่แล้ว +1

      @@joshbrown1806 True, now that I think about it. I've always seen the bodies of the squirrels that have been blown clear. Hadn't really considered they may stay up there, arcing away. Damn tree rats.

  • @jeffclark5268
    @jeffclark5268 2 ปีที่แล้ว

    You do a spectacular job of hiding any smidgen of NB Power markings! Was only finally able to confirm by locations. 😀

  • @kctyphoon
    @kctyphoon ปีที่แล้ว

    I’m a lineman for the telephone company. Been placing poles for years and still have no idea how to “properly” place pole guards on the poles without just taping them on. Lol.. we started using black duct tape over thin electrical tape since we wait years for the power co to move their stuff onto the new poles.

  • @deptg33k
    @deptg33k ปีที่แล้ว

    Long time watcher here, we had a car run up a guy wire on the pole behind our house. Driver is okay, but it snapped the pole just above the top guy.
    What's replacement look like when it's the end pole on a span?

  • @pete9415
    @pete9415 3 ปีที่แล้ว +1

    ARCdoes all that in my state Been at it for years changing poles an new lines.

  • @jaspersonnyoner
    @jaspersonnyoner ปีที่แล้ว

    Do you use concrete forms for the poles to sit in or just sand?

    • @Bobsdecline
      @Bobsdecline  ปีที่แล้ว +1

      Not typically unless it's extremely soft ground or in water.
      We usually backfill with compacted soil or tailings.

  • @lucidmoses
    @lucidmoses 3 ปีที่แล้ว

    Don't Worry Be Happy - Bobby McFerrin

  • @dannynormile3550
    @dannynormile3550 3 ปีที่แล้ว +2

    Great video Aaron. Are all of your oil reclosers operated by a stick on the yellow ring/handle? In the states, we have control cabinets that can be operated at ground level, and disable reclosing.

    • @blakeslack
      @blakeslack 3 ปีที่แล้ว +1

      Probably depends on the equipment. I know with my company we have a mix of Hydraulic Reclosers that we manually block with the Handle on the device but we also have several SCADA controlled devices that we can block remotely or from the control box at the pole..

    • @Bobsdecline
      @Bobsdecline  3 ปีที่แล้ว +2

      Yes exactly, most of our have the control box. We've also moved to intellirupters, vacuum reclosers, EOR's etc..

  • @erikbrickman4461
    @erikbrickman4461 ปีที่แล้ว

    When my town replaces an entire row of poles like what is shown in this video, before installing the old pole they usually chop off part of the cross arm and remove 1 insulator so that one wire is not too close to the new pole. Has the company you work for ever tried this?

  • @Mrfreez713
    @Mrfreez713 3 ปีที่แล้ว +2

    Why are you guy’s rehab with wooden cross arms instead of steel arms?

    • @Bobsdecline
      @Bobsdecline  3 ปีที่แล้ว +3

      We've actually just switched over to fiberglass, using up what's left of our stock now

  • @redsquirrelftw
    @redsquirrelftw 3 ปีที่แล้ว

    Wow looks quite involved compared to if you could do it dead. I don't mind an outage myself but guess lot of people really can't go long without power.

  • @texasproud3332
    @texasproud3332 3 ปีที่แล้ว +2

    You say y’all schedule an interruption of service does include contacting the customers to let them know when they do it where Iam ONCOR utilities generally text or call us

  • @alasdairmunro1953
    @alasdairmunro1953 3 ปีที่แล้ว +1

    Appreate the detailed explanation !👍🏼😀

  • @charliec9291
    @charliec9291 2 ปีที่แล้ว

    Just subscribed to your channel, you have tons of great content! In the video you mentioned reclosing is disabled for any fault interrupting devices upstream of the planned energized work. In your experience, is Hot Line Tag (HLT) used as well if reclosers are equipped with it? Thank you for your time sir!

    • @Bobsdecline
      @Bobsdecline  2 ปีที่แล้ว

      Hey thanks Charlie!
      Yes most of our equipment have a light or flag that automatically pop up now. We also manually install a tag on the pole or switch gear at all times when reclosing is removed

  • @nouhishak3541
    @nouhishak3541 2 ปีที่แล้ว

    What is the monthly wage for this job

  • @dclawnmaintenanceandsnowre4099
    @dclawnmaintenanceandsnowre4099 3 ปีที่แล้ว +1

    I was wondering is it normal for a breaker and a Transformer to spark a bit wild raining

    • @rupe53
      @rupe53 3 ปีที่แล้ว +3

      I would say no, there should be no sparks or arcs. You can call your utility company with the pole number and let the experts make the judgement on what to do about it.

    • @dclawnmaintenanceandsnowre4099
      @dclawnmaintenanceandsnowre4099 3 ปีที่แล้ว +2

      @@rupe53 thank you very much

    • @Bobsdecline
      @Bobsdecline  3 ปีที่แล้ว +3

      💯

  • @BroCoby
    @BroCoby 3 ปีที่แล้ว +2

    You guys make this a little more difficult than need be

  • @ajaykc482
    @ajaykc482 9 หลายเดือนก่อน

    Can you show us construction notes

  • @JCWren
    @JCWren 3 ปีที่แล้ว +2

    Do they cut the old poles at ground level, or actually pull them out completely?

    • @tsheejkoo
      @tsheejkoo 3 ปีที่แล้ว +2

      If telephone and /or cable are attached to the pole. The utility company will cut approximately 5'-10' off the top and "abandon" the pole for the telecommunications company to come at a later date and remove completely out the ground, PTD (pull, transport, dispose).

    • @blakeslack
      @blakeslack 3 ปีที่แล้ว +1

      @@tsheejkoo yeah when phone/cable maybe get around to transferring their stuff in the next 4 or 5 years :D. haha

    • @lalarobert
      @lalarobert 3 ปีที่แล้ว

      @@blakeslack Truth.

    • @blakeslack
      @blakeslack 3 ปีที่แล้ว +1

      @@lalarobert a constant battle for us...especially as the old pole starts to lean more and more and people keep calling it in to us thinking its going to fall over

  • @tonybradford1719
    @tonybradford1719 3 ปีที่แล้ว +1

    I FOUND TRIPLEX AT MY COUSIN TRAILER JUST ROLLED UP SITTING AGAINST THE TRAILER THERE HASN'T BEEN ANY POWER WORK SINCE IT WAS PUT IN ABOUT 5 YEARS AGO

  • @gfy2979
    @gfy2979 3 หลายเดือนก่อน

    Where you sped up the footage it looks like you are speeding thru a workzone

  • @SeekingTheLoveThatGodMeans7648
    @SeekingTheLoveThatGodMeans7648 3 ปีที่แล้ว +1

    Survive till next Christmas...

  • @wesmarks5
    @wesmarks5 3 ปีที่แล้ว

    I have seen several houses that are just covered in Christmas lights. Do the power companies get involved or is the power already provided meet the needs of the house?

    • @ShainAndrews
      @ShainAndrews 3 ปีที่แล้ว +2

      Why would it be any concern of the power provider? What side of the demarcation are the lights?

  • @kevini001
    @kevini001 2 ปีที่แล้ว

    Every single pole should have been changed to at least a 45 foot class 2. With that Guage wire, using an old pole is asking for trouble.

  • @TheKdizzle1971
    @TheKdizzle1971 3 ปีที่แล้ว

    Dude, you said 'out' and not 'ooooooot???'

  • @cvetomircvetkov5670
    @cvetomircvetkov5670 3 ปีที่แล้ว

    If you guys in North America start using concrete poles you wouldnt need to change them :)

    • @ShainAndrews
      @ShainAndrews 3 ปีที่แล้ว +1

      Right...

    • @pete9415
      @pete9415 3 ปีที่แล้ว

      They’re changing concrete to steel in my area. Must be the new thing.

    • @yobi765
      @yobi765 3 ปีที่แล้ว

      A lot of states are putting power lines underground nowadays.

    • @redsquirrelftw
      @redsquirrelftw 3 ปีที่แล้ว +1

      Funny enough we do have some concrete poles in my area, typically they are only lamp posts though but I've seen the odd hydro ones too. I've also seem them where the rebar is all rusty and they are chipping apart... so guess they don't last forever either.

    • @ShainAndrews
      @ShainAndrews 3 ปีที่แล้ว +1

      @@redsquirrelftw Exactly.

  • @mikaeljiskovkristensen7861
    @mikaeljiskovkristensen7861 2 ปีที่แล้ว

    why not use underground cables instead. no ice, or trees can short the lines, if ug is used.
    i live in denmark, and we only have 380 and 150 kv overhead lines and som small parts of the 60 kv grid in the air. 12 kv and 72 kv xlpe cables is more cheap and durable, than overhead lines. and no climbing in poles, the transformers also are in a small building on the earth surface.

  • @armandoniebla
    @armandoniebla 2 หลายเดือนก่อน +1

    Armando.nieblapasswordpasswordpasswordpasswordpassword Po assword

  • @Mrfreez713
    @Mrfreez713 3 ปีที่แล้ว +1

    Why are you guy’s rehab with wooden cross arms instead of steel arms?