  • The PROOVE´it system is used to evaluate the resistance of concrete to the ingress of chloride ions in three ways:
    - By determining the total electrical charge that passes through
    a saturated concrete specimen by applying an electrical
    potential across the specimen in accordance with AASHTO T
    277 or ASTM C1202. This is known as the “Coulomb Test” or
    the “Rapid Chloride Permeability Test (RCPT).”
    - By measuring the penetration depth of chloride ions, after an
    electric potential has been applied to the specimen in
    accordance with Nordtest Build 492 to determine the “Chloride
    Migration Coefficient,” which can be used to estimate the
    chloride diffusion coefficient for service life calculations.
    - By measuring the current passing through a saturated
    concrete specimen and determining the bulk conductivity in
    accordance with ASTM C1760.

ความคิดเห็น • 11

  • @omark2776
    @omark2776 2 ปีที่แล้ว +1

    What kind of silicon is used between the sample and the ribber exactly?

  • @TahmasbKhazaeni-mw3ii
    @TahmasbKhazaeni-mw3ii 6 หลายเดือนก่อน

    Hello,
    We have recently purchased a unit of equipment with 3 cells. I am currently working on running our first test, but I have encountered two issues. Firstly, I did not find the Silicon that was supposed to come with the equipment. Secondly, I am also unsure about the location of the software. Can you kindly advise me on these two concerns?
    Thank you.

  • @user-tx8jg6ob2c
    @user-tx8jg6ob2c ปีที่แล้ว

    Hello, How much minimum vacuum pressure to be maintained in desiccator?

  • @mithilaevent
    @mithilaevent 5 ปีที่แล้ว

    This machine is for both rcpt & cm test???

  • @markcruz2614
    @markcruz2614 8 ปีที่แล้ว

    hi...may I ask, what is the reason why we shouldn't fill it up to the bottom of the fill hole? normally in our lab i saw them, they filling it up to that level. thanks,.

    • @GermannInstrumentsASKbenhavn
      @GermannInstrumentsASKbenhavn  6 ปีที่แล้ว +1

      Hello Mark, it is because we don't want the reservoir to spill liquid out once the temperature probe is introduced.

  • @sidbharat
    @sidbharat 4 ปีที่แล้ว

    Can this be used for NT Build 443?

  • @shubhendrakumar9862
    @shubhendrakumar9862 ปีที่แล้ว

    How ro download Proove it PC software, Please Help

  • @yuvrajpatil6644
    @yuvrajpatil6644 5 ปีที่แล้ว

    Hello iam last year civil engineering student can i get your email id for more details regarding this test

  • @hughm1383
    @hughm1383 8 ปีที่แล้ว

    The background music is unnecessary and gave me a headache.