  • Dear engineers
    Welcome to Electrical stuff ,this is a flat form to share electrical knowledge in building sector
    Abu Dhabi distribution company (ADDC ) ,Dubai electricity and water authority are two major electricity companies in United Arab emirates.
    In this video I like to give you few difference between these two distribution companies
    1-In this video you will know voltage, Power factor, frequency etc of two distribution boards
    2-What type of earthing system implemented
    3-What type of switchgear & incomers are preferred
    4-How distribution boards classified in ADDC and DEWA
    So watch the video till the end to know these differences
    If you want to me to make video on detailed regulation of DEWA and ADDC please let me know in the comment section
    Amazon link to purchases :Electronics
    amzn.to/3wepgbg

ความคิดเห็น • 31

  • @electricalconcept32
    @electricalconcept32 2 ปีที่แล้ว +2

    Thanks to guide me today i pass DM/DEWA exam

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      Congratulations and Glad to hear .keep progressing

  • @SanthoshBabuDuraisamy
    @SanthoshBabuDuraisamy 3 หลายเดือนก่อน

    Great Work!

  • @gamalabdelnaser8401
    @gamalabdelnaser8401 2 ปีที่แล้ว +1

    ADDC distribution panel 14 ways not 12 , thank you for your effort

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      Yes it's by mistake
      14 x 3 = 42 ways 3 phase and 14 single phase
      Thanks

  • @sinanmahmood0
    @sinanmahmood0 2 ปีที่แล้ว +1

    Aprecaite your hard working

  • @harikrishnan2404
    @harikrishnan2404 2 ปีที่แล้ว +1

    Thanks a lot engineer,pls upload short circuit calculation

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      Responded earlier comment please check

  • @ABDULSAMAD-888
    @ABDULSAMAD-888 2 ปีที่แล้ว +1

    Thank you for information kindly make a video on cable and breaker sizing according to load..

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      Already I cover this topic in electrical design as well distribution board size calculation in detail.
      So watch this video to know more

  • @harikrishnan2404
    @harikrishnan2404 2 ปีที่แล้ว +1

    Thanks a lot engineer, pls upload short circuit culculation

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว +1

      Thanks
      Short circuit study is a big subject to understand this concept need to know basic such as how circuit breaker characteristics etc..
      More over we can know the short circuit two basic one is software study and real time load.so we start one by one will explain to complete this chapter .
      Currently I am on vacations and I make few videos during vacation.
      Definitely I will start this series.

  • @udayraut2113
    @udayraut2113 ปีที่แล้ว +1

    Nice video

    • @ElectricalStuff
      @ElectricalStuff  ปีที่แล้ว

      Thanks

    • @udayraut2113
      @udayraut2113 ปีที่แล้ว

      @@ElectricalStuff I am Electrical Graduate, worked in UAE for 10 years, looking for Job. Age 61 years. At present in India.

  • @arfatstech
    @arfatstech 2 ปีที่แล้ว +1

    Thanks for great video but how to submit electrical drawing in ADDC video .We wanna submit video.

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      You are welcome .
      You want to submit drawings to addc for that you want to know procedure . You want to make me a video . This is your question crt ?

  • @johnjoseph1789
    @johnjoseph1789 2 ปีที่แล้ว +1

    Sir how to calculate normal villa main panel earthing condecter size

    • @ElectricalStuff
      @ElectricalStuff  2 ปีที่แล้ว

      Send email to electricalstuff.mep@gmail.com
      I will guide you

  • @hariranormal5584
    @hariranormal5584 ปีที่แล้ว +1

    PV tied grid difference from ADDC and DEWA?

  • @sabaaziz5926
    @sabaaziz5926 ปีที่แล้ว +1

    In ADDC you can provide 13A twin sockets only. But in DEWA you can provide both single & twin socket.

    • @ElectricalStuff
      @ElectricalStuff  ปีที่แล้ว

      Thanks for sharing
      Do you mean Addc they won't accept single sockets ?

    • @BassamShaaban91
      @BassamShaaban91 ปีที่แล้ว

      Are you sure? I don’t think so !

    • @ElectricalStuff
      @ElectricalStuff  ปีที่แล้ว

      @@BassamShaaban91 yes you can provide i work many projects with DEWA approval

  • @samehmohamed6754
    @samehmohamed6754 8 หลายเดือนก่อน

    mechanical maintenance